Tender For Provision Of Multipurpose Hall (4000 Trainees) At Ats Belgavi; 2 GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to X are prepriced by MES under Ser No. 1 to 10. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. 3 Lumpsum price worked out by the contractor for “Building or works” as listed in Schedule ‘A’Part–I 4 Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’Part–II 5 Lumpsum price worked out by the contractor for “Internal Electric Supply as listed in Schedule ‘A’Part–III 6 Lumpsum price worked out by the contractor for “Site Clearance” as listed in Schedule ‘A’ Part – IV. 7 Lumpsum price worked out by the contractor for “Road / Path / Culvert / Hardstanding ” as listed in Schedule ‘A’ Part – V. 8 Lumpsum price worked out by the contractor for “Area Drainage as listed in Schedule ‘A’ Part VI. 9 Lumpsum price worked out by the contractor for Sewage Disposal as listed in Schedule ‘A’ Part VII . 10 Lumpsum price worked out by the contractor for “External Water Supply” as listed in Schedule ‘A’ Part – VIII. 11 Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part – IX. 12 Lumpsum price worked out by the contractor for “Lightning Protection” as listed in Schedule ‘A’ Part – X. 13 Sch A Part - XI : Fittings, Fixtures & Misc items : INTERNAL WATER SUPPLYSupply and fix 15mm bore two way bib tap cast copper alloychromium plated with crutch or butterfly handle, screwed down, screwed to PPR / galvanised iron pipe providing aerated flow of water complete all as specified and as directed. 14 Supply and fix 15mm bore angle cock cast copper alloy fancy type chromium plated fancy type, screwed down, screwed for PPR pipe complete all as specified and as directed. 15 INTERNAL ELECTRIC SUPPLYSupply and fix 150 watt LED surround high efficiency round highbay light in PDC housing suitable for industrial application. The luminaire has efficacy 110 Im/w reduce quantity/wattage thereby reducing operational cost. It has 10 KV SPD & ingress protection of IP66 with additional safety chain complete all as specified and as directed. Make : Crompton Cat Part N LHB11-150-CDL/60-M or equivalent in approved make 16 Supply and fix PVC junction box of size 8x10 inch including provision of cutting board for housing P/T Switch/socket etc complete all as specified and directed.Note: P/T switch/socket will be measured & paid separately under relevant item of this schedule. 17 Supply and fix BLDC Powerful HVLS (High Volume Low Speed) Fan of 16 feet diameter, with blades, mounting assemblies and accessories 3 phase 440v Min air delivery 23500CFM with service value 6.00 BEE incl DOL starter,series 10 large industrial ceiling fan wield outstanding motor control to generate even and gentle winds, gearless direct drive motor, no need for regular lubrication maintenance including all fixing arrangementsetc complete all as specified and as directed. 18 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type MLTP (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3 phase, 4 wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. Complete as specified and directed by engineer-in-charge. 19 The MLTP shall comprise of the following(A) BUSBAR CHAMBER(i) 01 set (3L+N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc, with complete connection.(B) INCOMING(i) 250A, 415 V, Ics = 100% Icu = 25 KA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip , adjustable overload setting (0.7 - 1xIn), adjustable short-cicuit setting (5-10 x Ir) adjustable neutral protection (N, N/2, OFF) front indication LEDs (ready overload and pre-alarm & overload)-01 Nos(ii) CI 1.0 multi-function meter capable of measuring V,A,F,PF, W/VA. Wh/VAh, Runhrs, Onhrs & interupts - 01 Nos.(iii) LED phase indicators (Red, Yellow, Blue)-01 set(C) OUTGOING(i) 40A, 415 V, Ics = 100% Icu = 16 KA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip , adjustable overload setting (0.7 - 1xIn), adjustable short-cicuit setting (5-10 x Ir) adjustable neutral protection (N, N/2, OFF) front indication LEDs (ready overload and pre-alarm & overload)-02 Nos. (For PDB#01 & PDB#02)(ii) 32A, 415 V, Ics = 100% Icu = 16 KA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip , adjustable overload setting (0.7 - 1xIn), adjustable short-cicuit setting (5-10 x Ir) adjustable neutral protection (N, N/2, OFF) front indication LEDs (ready overload and pre-alarm & overload)-06 Nos. (For PDB#03 & PDB#04 & PDB#05 & PDB#06 & UTILITY PANEL & SPARE)(iii) CI 1.0 multi-function meter capcble of measuring V,A,F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts-08 Nos.(iv) LED phase indicators (Red,Yellow,Blue)-01 set 20 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type UTILITY PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3 phase, 4 wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. Complete as specified and directed by engineer-in-charge. 21 The MLTP shall comprise of the following(A) BUSBAR CHAMBER(i) 01 set (3L+N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc, with complete connection.(B) INCOMING(i) 32A, 415 V, Ics = 100% Icu = 16 KA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip , adjustable overload setting (0.7 - 1xIn), adjustable short-cicuit setting (5-10 x Ir) adjustable neutral protection (N, N/2, OFF) front indication LEDs (ready overload and pre-alarm & overload)-01 Nos(ii) CI 1.0 multi-function meter capable of measuring V,A,F,PF, W/VA. Wh/VAh, Runhrs, Onhrs & interupts - 01 Nos.(iii) LED phase indicators (Red, Yellow, Blue)-01 set(C) OUTGOING(i) 10A, 415 V, Ics = 100% Icu = 16 KA, 50 Hz 3P MCCB, conforming to IEC 60947-2, having microprocessor based trip , adjustable overload setting (0.7 - 1xIn), adjustable short-cicuit setting (5-10 x Ir) adjustable neutral protection (N, N/2, OFF) front indication LEDs (ready overload and pre-alarm & overload)-04 Nos. (For water.S & HVLS -1&2 & SPARE)(ii) 10A, 230 V, Ics = 100% Icu = 16 KA, 50 Hz 2P MCCB, conforming to IEC 60947-2, having microprocessor based trip , adjustable overload setting (0.7 - 1xIn), adjustable short-cicuit setting (5-10 x Ir) adjustable neutral protection (N, N/2, OFF) front indication LEDs (ready overload and pre-alarm & overload)-01Nos. (For OUTSIDE LIGHTING)(iii) CI 1.0 multi-function meter capcble of measuring V,A,F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts-05 Nos.(iv) LED phase indicators (Red,Yellow,Blue)-01 set 22 SEWAGE DISPOSAL Supply and fix SFRC heavy duty cover of dia 560mm (clear open) 600mm outer to outer for manholes for following specification as per IS 12592 (2002) make high tech concrete, FI 90x1.35mm thick outer cover, 4mm TMT wire mesh (core wire) with hook 4mm, 8mm TMT bar @100mm c/c at bottom, 10mm TMT bar @100mm c/c at top, 16mm TMT bar for flushed handles, RCC M35 design mix concrete, outer cover / collar of metal sheet 1.35mm and width 90mm all as specified and as directed. 23 EXTERNAL WATER SUPPLYMaterial and labour for Cutting and tapping of existing pipe line 150 mm dia DI Pipe & inserting the TEE fortaking branch including necessary fittings and accessories of connection complete all as specified and directed by Engr-in-Charge. 24 Construction of valve chamber of size 600x600x600mm internal size suitable for valves with PCC 1:4:8 type D2 foundation and brick wall in cement mortar 1:4 PCC 1:2:4 type B1 for coping rendering in CM (1:6) 15mm thick including provn of mild steel sheet cover 3.15mm thick on 40x40x6mm angle iron frame work with two coats of synthetic enamel black paint over a coat of red oxide primer and locking arrangement including necessary excavation earth work all as specified and directed by Engr-in-Charge. 25 Cutting the tar macadam road / hard standings for laying GI Pipe and excavating not exe. 1.5 wide and 1.5m indepth and getting out all as directed including filing back and finishing it with PCC to matching with the surroundings complete all as specified and as directed. 26 EXTERNAL ELECTRIC SUPPLYSupply, install, testing and commissioning of outdoor type step down transformer of capacity 160 KVA copper wound HT 11 KV, 3 Phase, LT 433 volts, 3 Phase 4 wire, 50 Hz, ONAN cooled with 7 position off load tap changer (tapping range +/- 7.5% in steps of 2.5% each) with vector group Dyn-11 all as per IS-1180 (Part-I) 2014 with energy efficiency level 2 complete with first filling of transformer oil and following accessories including necessary foundation and fencing with gate:- (a) LV cable box with cable glands (b) Name, Rating & Diagram Plate - 1 No(c) OFF circuit tap changing switch - 01 No(d) Earthing Terminals - 02 Nos(e) Lifting Lugs - 02 Nos(f) Oil level indicator (flush tube) - 01 No(g) Oil drain valve with plug - 01 No(h) Oil filter valve with plug - 01 No(j) Conservator with oil filling hole - 01 No(k) Thermometer pocket - 01 No(l) 4 dial type thermometer stem type - 01 No(m) Air release plug - 01 No(n) Silica gel breather - 01 No(o) Explosion vent - 01 No(p) Unidirectional rollers - 04 Nos 27 Note:- Any left out standard accessories which are not mentioned above for smooth functioning of the transformer shall be included in the quoted rate without any extra cost. 28 Supply, install, testing and commissioning of LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size to accommodating the following accessoriestotally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made out of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron frame work with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 7 - tank metal treatment process and duly powder coated with 300A electricalgrade aluminium bus bar for phases and neutral complete with suitable digital type meters resin cast CTs, CPRI approved type tested, internal wiring all includingthe following incoming complete all as specified and directed (LT Panel-1):-Note:- Connection from Main bus bar to OutgoingMCCB should be provided through bus bar of suitable rating instead of copper wires 29 (a) MCCB FP 250 Amps rating, 50 Hz, 415 V with rupturing capacity 36 KA, adjustable type - 01 No (Incoming)(b) MCCB FP 250 Amps rating, 50 Hz, 415 V with rupturing capacity 36 KA, adjustable type - 01 No (Outgoing)(c) Voltmeter 0-500 V digital type with selector switch - 1 No.(d) Indicator lamp LED type - 3 Nos (R, Y & B)(e) Digital type meters ampere meter with suitable selector switch incl suitable resin cast CTs of 300/5 A - 01 No 30 Supply, install, testing and commissioning of LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size to accommodating the following accessoriestotally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, vermin proof outdoor type made out of 3.15 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron frame work with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 7 - tank metal treatment process and duly powder coated with 300A electricalgrade aluminium bus bar for phases and neutral complete with suitable digital type meters resin cast CTs, CPRI approved type tested, internal wiring all includingthe following incoming complete all as specified and directed (LT Panel-2):-Note:- Connection from Main bus bar to OutgoingMCCB should be provided through bus bar of suitable rating instead of copper wires 31 (a) MCCB FP 250 Amps rating, 50 Hz, 415 V with rupturing capacity 36 KA, adjustable type - 01 No (Incoming)(b) MCCB FP 63 Amps rating, 50 Hz, 415 V with rupturing capacity 16 KA, adjustable type - 04 Nos (outgoing) (c) MCB TPN 25 Amps rating, C Curve, 415 V with rupturing capacity 10 KA - 01 No (outgoing) (c) MCB SPN 32 Amps rating, C Curve, 240 V with rupturing capacity 10 KA - 09 Nos (outgoing) (c) MCB SPN 6 Amps rating, C Curve, 240 V with rupturing capacity 10 KA - 08 Nos (outgoing) (d) Voltmeter 0-500 V digital type with selector switch - 1 No.(e) Indicator lamp LED type - 3 Nos (R, Y & B)(f) Digital type meters ampere meter with suitable selector switch incl suitable resin cast CTs of 300/5 A - 01 No 32 Supply and fix DWC Pipe IS-16205, size inner dia 103 mm, outer dia 120 mm for cable protection in wall/under ground laying of UG cables including SNAP-FIT Coupler and all fittings as required at sitecomplete all as specified and as directed by Engr-in-Charge. 33 Supply and fix DWC Pipe IS-16205, size outer dia 40 mm for cable protection in wall/under ground laying of UG cables including SNAP-FIT Coupler and all fittings as required at sitecomplete all as specified and as directed by Engr-in-Charge. 34 Material and labour for Cutting the tar macadam road / hard standings for laying cable and excavating not exceeding 0.45m wide and 0.75m indepth including filing back, watering, well ramming and finishing it with 200mm thick PCC 1:4:8 type D-2 completeall as specified and as directed. 35 Material and labour for LT Cable route indicator with a welded/riveted disc of 4 inch dia and engraved with cable with cable route marker made out of angle iron 40 x 40 x4 mm thick dug in ground with in and incl PCC 1:3:6 type C1 using 20mm graded aggregate at approx distance 100 mtr including necessary earth work complete all as specified and directed by Engr-in-Charge. 36 LIGHTNING PROTECTIONSupply and fix Air termination, single pointed aluminium rod 12mm dia 300mm long extended with GIPipe 25mm medium grade 1.5 mtr with insulatorand PCC pit 1:2:4B1 for fixing purpose of Air termination rod including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engr-In-Charge. 37 AIR CONDITIONINGSupply and fix air cooled split unit air conditioner, electric driven, single phase of capacity of 2 TR, BEE 5 star rated complete all as specified and directed by Engr-in-Charge. 38 Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled wall mounted, copper wound with digital display indoor type for AC & designed for input variation between 140 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 3 % and of capacity 5 KVA complete all as specified and directed by Engr-In-Charge 39 WATER COOLERSupply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage 150 liters and nominal cooling of 150 litres per hour complete all as specified and directed by Engr-in-Charge. 40 Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volt to 250 Volts with output voltage stabilized at 230 V with accuracy of +-2.5% and of capacity 2.0 KVA complete all as specified and directed. 41 DG SETSupply, install, testing and commissioning of acoustic proof diesel engine driven generating set, fully wired, 415 Volts, AC, 3 phase 4 wire, 50Hz having capacity 112KW / 140 KVA with CPCB-IV+ continuous rating at power factor 0.8 (lagging) as per IS-4722 and connections as per IE rules complete with liquid cooled 4 stroke Diesel engine with electric start with 12V DC battery, developing minimum 175 BHP at 1500 RPM under NTP prevailing at Sambra area, Belgavi considering derating factor and shall conform to IS:10000 / 150 3026 / BS-5514 with provisions of 10% over loading for 1 hour for every 12 hours running with A1 class governing and all standard safety type, screen protected, revolving field, self excited, self regulated alternator conforming to BSEN-60034 with IP 23 protection complete with integrated AMF control panel with microprocessor based relays/ MCCB / MCBs / Contactors, multifunction meter showing KWH, KVA, PF, Amps, Volts, frequency, indicating lamps, 12 Volt battery charging unit including 12 Volts battery etc required as per latest standard engineering practices including sound proof canopy designed to meet MoEF / CPCB Norms of 75dBA 42 Note: (i) The cost of PCC foundation as per the recommendation of OEM shall be deemed to be included in the quoted rate.(ii) Cost of fuel and other expenses for carrying out acceptance test of the DG set shall deemed to be included with the quoted rate.
|