Tender For Civil Construction And Repair Works In Div- Iii(B) Area, (Arc) - 1 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 2 Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. 3 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix 4 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix 5 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix 6 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 7 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : 8 Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 9 Columns, pillars, posts and struts etc. 10 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ("Original producers" who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786)Thermo-mechanically Treated bars (Conforming of relevent IS code) 11 Flyash Flyash Brick work with flyash Flyash Bricks of class designation 75 in superstructure above plinth level upto floor Three Level in all shapes and sizes in :Cement mortar 1 : 6 (1 cement : 6 coarse sand) 12 Half brick masonry in Superstructure , above plinth level upto floor Vlevelusing bricks of designation 75 Cement mortar 1 : 6 (1 cement : 6 coarse sand) 13 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 14 M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). 15 M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 16 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand). 17 Add extra for Random Rubble stone masonry with hard stone in 18 Square or Rectangular pillars 19 Re-fixing of old stone slab 20 (A) White Ashlar 21 Providing and fixing Marble stone flooring table rubbed, 15-18 mm thick over 20mm (Av.) thick base of CM 1:4 (1 cement : 4 coarse sand) jointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. 22 Makrana "Adanga". 23 Above 3601 Cm2 Slabs 24 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. 25 South (Red) 26 Above 3601 Cm2 Slabs 27 Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 28 Granite/Kota Stone Work 29 Full Edge moulding 30 Half Edge moulding 31 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 32 Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 33 Add extra if square, rectangular hollow tubular sections are used. 34 Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint 35 Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : 36 Windows side hung /Ventilators top or centre hung (openable) 37 Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. 38 Providing and fixing steel glazed window frame made out of 80x40 mm hollow sheet section of 16 gauge thickness, joint mitred weldedand grinded including hold fast of steel lugs 13mm x 3mm and 15 Cm long embedded in C Cblock 15 x 10 x 10 Cm of 1:3:6 nominal concrete and including fixing of pivoted hinges of superior quality, window shutters made out of 50 x 25.0 mm hollow steel section 15 mm paitam of 18 gauge thickness, joint mitred and grinded including 10mm x 10mm square bars welded to framefor paitam fixing float glass 4mm thickpanes with glazing clips and metal sash putty andfixing of shutters frames peg stay, U shape handle 100 mm long, tower bolts 100 mm long of steel powder coated superior quality including fixing and jointing with frame hinges priming coat with steel primer complete in all respect as per direction of Engineer-in –charge 39 Window fixed. 40 Supplying and fixing of chain link fencing with angle iron posts 50x50x6mm placed at every 3 Mtr. apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with (50 x 50 x 6cm) angle iron provided and fixed and fitted with posts including earth work in excavation etc. complete with chain link size. 41 50mm x 50mm x 3.15mm 42 Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size. 43 Welded mesh 50 mmx 50 mm x 2.1 mm 44 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces)excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required. 45 0.63 mm thick with zinc coating not less than 275 gm/m2 46 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 47 3.0mm thick (Wt. 5.0 Kg./Mtr. Sq.) 48 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 49 40mm wide and 4mm thick 50 Providing & laying Chequered terrazzo tiles of approved make 22mm thick with marble chips of size upto 6mm, in floors, jointed with neat cement slurry mixed wit pigment to match the shade of tiles including rubbing and polishing complete in all respect as per specification, on 28mm thick bed of C.M. 1:4 : 51 Light shade using shade cement. 52 Polished Blue Kota stone flooring skirting, laid over 20 mm thick base of C.M. 1 : 4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete :For area of each slab from 2001 to 5000 Sq.Cm : 25 mm thick slab. 53 Rough chisel dressed stone flooring over 20 mm (Av.) thick base in CM 1 : 6 including pointing with cement mortar 1 : 2 (1 cement : 2 stone dust) with and admixture of pigment to match the shade of stone with joint thickness upto 15 mm : 35 mm thick red sand stone. 54 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin- charge). 55 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20mm thick. 56 20mm thick. 57 12mm thick. 58 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete 59 Pointingonstonemasonryincementsandmortar 1:3 (1 cement : 3 sand) : 60 Raised and cut pointing. 61 Distempering with dry distemper of approved brand and shade (two or more coats) and of required shade on new work, over and including, priming coat of whiting to give an even shade including all scaffolding. 62 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. 63 Finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding: 64 New work (Two or more coats applied @ 3.84 kg/10 sqm). 65 Painting exterior surface ofWallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect including scaffolding and safety provision 66 New Work 67 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work 68 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : One or more coats on old work. 69 Demolishing brick work manually/ by mechanical means including stacking of serviceable MATERIAL and disposal of unserviceable MATERIAL within 50 metres lead as per direction of Engineer-in-charge. In cement mortar. 70 Dismantling stone slab/ terrazo chip flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. 71 Dismantling of cement concrete platform along with curtain walls and base concrete etc. including stacking of useful materials near the site and disposal of unserviceable materials within 50 metreslead : 72 Above 1.44 Sqm to 2.52 Sqm 73 Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 Itr/sq.mt. by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane.3 mm thick 74 Supply & fixing of one side polished black granite/white marble stone 14-20mm thick of size 3"x2" with engraved and gold colour painted letters (upto 500 letters)& borders including dismatalling plaster for fixing stone and finishing the surface including cost of stone and other material, carriage, loading, unloading with all leads & lifts as per direction of Engineer Inchagre. 75 Supply & Stacking good soil of earth at site complete including loading unloading & Transportation etc. Good soil of earth 76 Spreading of manure and good earth in required thickness (cost of manure and good earth to be paid separately). 77 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia 78 Carriage of materials Earth, Sand, Lime, Morrum manure or sludge including all lead and lift and loading & unloading. Up to 5 KM 79 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 80 Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) For fixed portion 81 For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) 82 Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge. Prelaminated particle board with decorative lamination on both sides. 83 Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.) With glass panes of 4.0 mm thickness ( weight not less than 10.0 kg/sqm) as per IS : 2835. 84 Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium sec (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge. Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) 85 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure "A":30 mm thick commercial Veneer Both side 86 Demolishing cement concrete manually/ by mechanical means including disposal of MATERIAL within 50 metres lead as per direction of Engineer-in-charge. 1: 3: 6 or richer mix. 87 Random rubble dry stone Kharanja under floor. 88 P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors: Exposed on wall 89 15 mm dia nominal bore "B" Class 90 25 mm dia nominal bore "A" Class 91 Dismantaling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled Material, disposal of unserviceable Material and stacking the serviceable Material with all lift and lead of 1000 metres. [MoRTH Specification: Clause 202]. Steel workSteel work in all type section upto a height of 5 meters above plinth level (Riveted work where rivets are required to be cut shall be measured and paid for separately). Including dismembering 92 Random Rubble stone masonry with hard stone in superstructure above plinth level and upto five level above 30cm. thick walls in : Cement Mortar 1:6( 1-Cement : 6-Sand). 93 Providing and laying damp-proof course with cement concrete grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification . 50mm thick. 94 sanetry 95 Providing and fixing 3-layer PP-R (Polypropylene random coplymer ) pipes SDR 7.4 UV stabilized and antimicrobial fusion welded, having thermal stability for hot & cold water supply including all PP- R plain & brass threaded Polypropylene randomfittingsandfixingthepipewith clamps at 1 metre spacing. This includes testing of joint complete as per direction of Engineer - in charge.( INTERNAL WORK- EXPOSED ON WALL) 96 PN-16Pipe, 16 mm OD 97 PN-16Pipe, 20 mm OD 98 PN-16Pipe, 40 mm OD 99 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) 100 20mm nominal outer dia pipes 101 32mm nominal outer dia pipes 102 P & F PVC Storage Tank ISI Marked (IS: 12701) indicating theBIS license No), of approved make with cover, 25mm dia 1MlongG.I.over-flowpipe&25Cm. longwashoutpipewithplug&socket, including making connection etc., complete of approved design: 1000 (-do-) 103 P & F Full-way Valve(IS:778Mark)or wheelvalveofapprovedmake:Gun-metal 32mm nominal bore. 104 P & F Inlet Connection(AngleValves) Superiorquality,ofapprovedmake,for Washbasin,Gyseretc.C.P.Inlet connection15mm.Brass(IS:8931marked) 105 P&FBallCock(IS:1703Mark)with Rod &P.V.C.Ballcomplete: (-do-)wt.Not less than 800 gm, 32mm. 106 P&F15mm.DiaConnectionPipeof approvedquality/make:PVCpipewithC.P. Brass nuts upto length, 600mm 107 P&FPilllarCocks(IS:8931:1993 Mark)ofsuperiorqualityandapproved make:C.P.Pillarcock,Swan-neckwith casted spout, 15mm nominal bore. 108 P & F Full-way Valve(IS:778Mark)orwheel valve of approved make : 109 Gun-metal 15mm nominal bore. 110 (-do-) 25mm nominal bore. 111 (-do-) 50mm nominal bore. 112 Providing and Fixing UnplasticizedPoly Vinyl Chloride (UPVC) SWR Pipes Type Bforscilandwastedischargesystem (IS:13592:1992Marked)ofapproved quality /make 110 mm dia 113 P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: 114 Coupler (socket) 115 110mm dia 116 160 mm dia 117 Plain Tee 118 110mm dia 119 160mm dia 120 Door Tee 121 110mm dia 122 Bend 45 123 110mm dia 124 Vent Cowel 125 110mm dia 126 Door Bend (Left & Right) 127 110mm dia 128 Pipe Clip 129 110mm dia 130 Plain floor trap 131 110mm dia 132 P- Trap 133 110mm dia 134 Socket plug 135 110mm dia 136 Door Cap 137 110mm dia 138 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 M-10 cmthickC.C.1:5:10infoundation, 20mmthickinsiderplasterinCm1:6, finished with floating neat cement, 50mm thickM-15gradeC.C.flooring, earthworketc.completeasperdesign including disposal of surplus earth within a lead of 50 mtr. 139 -do- size 450 x 450mm depth upto0.5M Cement cover with frame 140 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make:Brass 400 gm,15mm nominal bore. 141 P & F Ball Cock(IS:1703Mark)with Rod& P.V.C. Ball complete :Brass wt.Not less than 300 gm,15mm. 142 P & F Indian type whiteglazed vitreous china1stqualityW.C.orissapan(IS:2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: 143 Size 580x440mm. 144 P & F WVC (10 litres) low-level flushingcistern with cover. 145 P & F WVC Wash basin(Istquality IS:2556Mark)ofapprovedmakewithC.I. brackets duly painted 1 No.15 mmC.P. Pillar cock (IS:8934 Mark) & 32 mmC.P.brasswastecouplingofapproved make, P.V.C Waste pipe with PVC nut32 mm complete including cutting & making good the wall : 146 Size 510 mm x 400 mm 147 P & F lst quality WVC Urinal(IS:2556 mark)with25mmdiaG.I.wastepipe, domewastecouplings,concealediron brackets or screws etc complete. 148 Flat Back (small) size 456x355x265mm. 149 P & F W.V.C. Urinal Partition Plate of approved standard make ofsize 630x315mmincludingmakinggoodthewall.
|