Tender For Provision Of Single Living Accommodation For Nco/Or At Fatehgarh Cantt. ; 1 Sch "A" Part-I (Building Work)Note :This schedule is pre-priced by MES and the pre-priced rate indicated are under Col. 5. 2 Total amount of Sch "A" Part II (Site clearance, Excavation and Earth work) 3 Total amount of Sch "A" Part III (Internal Water Supply) 4 Total amount of Sch "A" Part IV (Internal Electrification) 5 Total amount of Sch "A" Part V (Road, Path and Hard Standing) 6 Total amount of Sch "A" Part VI (Area Drainage) 7 Total amount of Sch "A" Part VII (Sewage Disposal) 8 Total amount of Sch "A" Part VIII (Security Wall, Fencing & Gate) 9 Total amount of Sch "A" Part IX (External Water Supply) 10 Total amount of Sch "A" Part X (External Electrification) 11 Total amount of Sch "A" Part XI (Hot Water Supply) 12 Total amount of Sch "A" Part XII (Dismantling/Demolition) 13 Sch "A" Part - XIII(Miscellaneous Items)Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as "Rs 0.00 under col.5 siginifies this fact only. 14 INTERNAL WATER SUPPLYS&F for two way Angle cock/ angle valve, fancy type, chromium plated, ISI marked with crutch or butterfly handle, screwed down, screwed for iron pipe and fixed to 15mm bore pipeand fixed complete all as specified and as directed. 15 S&F for 3 in 1 , CP wall mixture for mixing hot and cold water with overhead shower arrangement screwed down for iron pipe and and fixed for 15mm bore pipecomplete all as specified and as directed. 16 S&F for health faucet with 1.50 m long cord,chromium plated suitable for 15mm dia pipe including fixing of brackets complete all as specified and as directed. 17 INTERNAL ELECTRIFICATIONM&L for point wiring complete forOne light/Fan/Exhaust fan/Bell pointcontrolled by one switch with PVC insulated and unsheathed FRLSH cable 1.5 sqmm (nominal area), ISI marked,multi stranded copperconductor cable including ISI marked not less than 20mm dia medium grade PVC conduit concealed in wall , MS conduit in roof/floors, factory made pressed steelconcealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete,including 1.5 Sqmm PVC ,FRLSH cableinsulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories and complete all as specified and directed.Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost. 18 M&L for point wiring complete for One light pointcontrolled by two2-way switches with PVC insulated and unsheathed FRLSH cable1.5 sqmm (nominal area), ISI marked,multi stranded copperconductor cable including ISI marked not less than 20mm dia medium grade PVC conduit concealed in wall , MS conduit in roof/floors, factory made pressed steelconcealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete,including 1.5 Sqmm PVC ,FRLSH cableinsulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories and all as specified and directed.complete .Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost. 19 M&L for point wiring complete for One 5 pin 5 Amp switch socket out let point on an independent board with PVC insulated and unsheathed FRLSH cable2.5 sqmm (nominal area), ISI marked,multi stranded copperconductor cable including ISI marked not less than 20mm dia medium grade PVC conduit concealed in wall , MS conduit in roof/floors, factory made pressed steelconcealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete,including 2.5 Sqmm PVC ,FRLSH cableinsulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories complete for max four nos socket outlets all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost. 20 M&L for point wiring complete with PVC insulated and unsheathed, FRLScable 2.5 sqmm (nominal area), ISI marked, stranded copperconductor single core including ISI marked 20mm dia PVC conduit concealed in wall and MS conduit in roof/floor slab & ceiling, pressed GI concealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete, including 2.5 Sqmm, FRLS cablePVC insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all for max two nos socket outlets all as specified and directed. Note :- In case of roof/ceiling, heavy duty pipe shall be used without any extra cost. 21 S&F switch flush type 5/6 Amps single pole two way complete all as specified and dierected. 22 S&F LED batten Tube light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (4 FT20 W), luminaire lumen >2000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSIBin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification.complete all as specified and directed. 23 S&F LED Building security light fitting with aluminum pressure die cast housing, high purity PC Fresnel diffuser with silicon gasket for IP-65 protection, power consumption <25 W (25/30W) & luminaire lumen >2500 lm and system efficiency > 120 lm/W, in built electronic driver prewired upto terminal block with driver efficiency >85% power factor >0.95 as light source with toughened glass including two core flexible copper wire of 1.5 sq mm from ceiling rose to the connector of fitting, connection wires not to be more than 2.5 in length and made out of GI tubing 25/32 mm dia /suitable dia light grade bend to shape security light fitting with necessary MS clamp 25 mm wide and 6 mm in thickness in suitable length not more than 30 CM and max length of pipe 1.5 Mtr long with one code of anti corrosive primer and two coats aluminum paint including nuts, bolts and washers complete all as specified and directed. 24 Supply and fixingBLDC type Ceiling fan 1200 mm sweep five star rated single phase 230V AC, Min 220 CFMwith fan remote , five star rating and ISI marked alongwith steel down rod and connecting up the fan to ceiling roseincluding PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to ceilingfan motor not less than 0.5 mtr long for connection complete all as specified.Note:- Necessary Fan hook deemed to be included in item rate. 25 Supply and fixingExhaust Fan high quality mettalic body, resistant to colour change 300 mm sweep five star rated, 900 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit pipefrom celling rose to exhaust fan motorcomplete all as specified and directed. 26 S&F MCCB 4 pole 415 V AC 50 Hz fixed type 125 -160 amps with breaking capacity 16 KA complete all as specified and directed. 27 S&F MCB TPN 63 amp 4 P 415 V AC 50 Hz fixed type with breaking capacity 10 KA complete complete all as specified and directed. 28 S&F MCCB VTPN DBdouble door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCCBand with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed. 29 S&F MCCB TPN DBdouble door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCCBand with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed.. 30 Supply and fixingMCB DB single pole with neutral sheet metal enclosure double door type, 240Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCBand with enclosure blank plates for unused way suitable for 12 wayall as specified and directed . 31 S&F MCB SPN 32/40 Amps "B" series,10 KA 240 Volts ,AC ISI marked all as specified and directed . 32 S&F MCB 6-32 Amps single pole,240V/415 V, "B" Series, 50 Hz ,ACwith breaking capacity 10 KA , complete all as specified and directed. 33 M&L submain wiring with two single core 6 sqmm FRLSH copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit concealed in wallsurface / ceiling for sub main connection including one 6 sqmm FRLSH one single core PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. Note:- Two single core 6 sqmm copper conductor for phase / neutral, one run PVC conduit and one run of 6 sqmm earth wire shall be considered & measured as one unit. 34 M&L submain wiring with four single core 6 sqmm FRLSH copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in PVC conduit not less than 32mm dia mediumgrade concealed in wallsurface / ceiling for sub main connection including one 6 sqmm single core FRLSH PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. Note:- four single core 6 sqmm copper conductor for phase / neutral, one run PVC conduit and one run of 6 sqmm earth wire shall be considered & measured as one unit. 35 M & L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground.(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr. belowground level connecting to galvanised earth lead wire 4.0 mm diaas earth lead upto 7.5 meters long connected by means of bolts, check nuts and washers of GI and earth wire protected by provision of GI pipe medium grade, 15 mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron 40 x 40 x 3mm fixingwith 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, with fixing arrangement, funnel, wire mesh and earth work in hard / dense soil, returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection all as specified and testing on completion. Note: The cost of excavation and earth work, PCC pit and pit covers, funnel and watering pipe, wire mesh, charcoal dust and common salt,20/ 40mm dia, medium grade, GI pipe as protection to GI wire 4.0 mm as main earthing lead from earth electrode to main TPN MCCBs DB/MCB DB/ test point length not less than 7.5mtrs) shall be deemed included in the unit rate for earthing and testing complete all as specified and directed . 36 Taking down old service connection/sub main wiring of any description of aluminium/copper conductor including batten/conduit/suspension wire etc and making good disturbed surface to match the existing surface. 37 Taking down old unservicable DB with MCBs/Main switches/MCB SP/SPN of any description and in any position. 38 Taking down oldlight fitting of any type and size complete all as directed 39 Taking down old point wiring of any description and any position complete all as directed 40 ROAD, PATH AND HARD STANINGM&L for preparation of road surface and applying thermoplastic reflective paint for marking of minimum 1.5 mm thick single coat as a centre line or edge line etc, road marking of 150/100 mm width using “HOT MARK” thermoplastic paint (Hot application) white and yellow by indigenous modern propelled road marking machine as directed including all ingredients such as binder, glass beads, titanium dioxide, calcium carbonate, inter fillers etc, thermoplastic requirement for glassbeadsshallbeconforming to BS-6086 of MOST specification including spraying of glass beads etc complete all as per manufacturer instructions and as directed. 41 SEWAGEDISPOSAL Construction of RCC Septic tank designedfor 100 users designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole opening with cover connection etc complete with effective depth of 1.5 m and overall depth of 3 m complete all as specified and directed. 42 Construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.40 m dia x 3.00 m effective depth complete all as specified and directed. 43 EXTERNAL WATER SUPPLY Cutting existing DI pipe line 150 mm dia for insertion of tee of size 150 x 150 x 100 mmfor branch connection including excavation and earth work complete 44 Supply, laying and jointing of ductile iron pipes with spigot and socket ends suitable for push on rubber tightened joint centrifugally cast, class(K-7), Inner side cement lining and outer side metallic zinc/black bitumen coating and any length , laid in trenches of 100 mm bore pipe including push on rubber (EODM) ring with ISI marked including special complete all as specified and directed. Note : (i) Please note cost of rubber tightened joints to be included in the above quoted rate. (ii) Excavation and earth work shall be masured and paid under respective schedule 45 Supply and fix Sluice valve 100mm bore both ends flanged class PN 1.6 with stainless steel spindle and 01 No hand wheel including making new flanged joint with 3 mm thick rubber gasket (Packing ring) with necessary bolt, nuts and washer of suitable size necessary including testing complete all as specified and directed. 46 Construction of Sub-class "B" brick masonry valve pit chamber of size 1200 mm X 1200 mm X 1200 mm (internal dimensions) including necessary excavation & earth work,150cmx 150cmx100cm thick base for foundation with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, 230 mm thick brick work in cement mortar (1:6), 10 mm thick rendering in cement mortar (1:4)on internal & exposed surfaces including mild steel sheet cover ofsize 1m x 1m x 3mm thick and angle iron of size (40 x 40 x 5) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface including necessary earthwork & demolition of existing old valve pit complete all as specified and directed. 47 Construction of Sub-class "B" brick masonry valve pit chamber of size 600 mm X 600 mm X 600 mm (internal dimensions) including necessary excavation & earth work,750cm x 750cm x 100cm thick base for foundation with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, 230 mm thick brick work in cement mortar (1:6), 10 mm thick rendering in cement mortar (1:4)on internal & exposed surfaces including mild steel sheet cover of size 75cm x 75cm x 3 mm thick and angle iron of size (30 x 30 x 5) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface including necessary earthwork & demolition of existing old valve pit complete all as specified and directed. 48 EXTERNAL ELECTRIC SUPPLY :Supply installation, commissioning and testing of transformer ( Energy efficient, EEL-2, Level - 2 ) copper wound step down 200 KVA out door type 11/0.433 KV at no load 3 ph, 4 wire 50 HZ AC with oil immersed air naturally cooled (ONAN Type), with 1st filling of IS-335, external cooling tubes/radiators, Double wound core type copper wound having no load voltage ratio 11 KV/415 Volts corresponding to principal tapping, delta connected primary side (HV Side) and star connected on secondary side (LV Side) in accordance with vector symbol DYN 11 (Vector group-4) with neutral brought out on LV side and having tapping on HV side for constant out put so as to alter vary secondary voltage from ± 2 ½ %,± 5% and± 7 ½ % in step to be changed by mean of manual off load tap changing arrangements complete confirming to IS-1180 Pt-I 2014 with latest at the time of installation all as specified. The transformer shall be complete with following fittings and accessories:-(a) Oil conservator tank with filling hole and cap drain and oil level gauge.(b) Silica gel breather with oil seal and first fill of dehydrating agent.(c) Pressure relief valve with automatic resetting arrangement after release of pressure - 01 set.(d) Oil temperature gauge having range 0-120 C with max reading 100 mm dia with shut off valve between the conservator and main tank.(e) Adequate No of thermometer pocket including one number for accommodating bulb type thermometer.(f) Drain cum bottom valve. 49 (g) Top filter valve.(h) Prismatic oil level gauge.(j) Inspection cover.(k) Cover lifting lugs.(l) Jacking and lifting lugs.(m) Rating and diagram plate.(n) Separate neutral bushing brought out for earthing on LV side.(o) First filling of transformer oil confirming to IS-335-1972.(p) Earthing terminals -02 Nos located on diagonally opposite transformer tank base including lugs.(q) Transformer should have cable box on LT sideand brass bushings on HT side. 50 Notes- (i) Drawing should be approved by GE before placing order.(ii) Transformer shall be platformed mounted as per TD drawing No TD-669 sheet 1/1 complete and rates quoted against this items shall be deemed to include for this provision. (iii) The contractor shall arrange factory visit as detailed by accepting officer to check the above system.(iv) Transformer should be 5 star rated and internal losses not more than 1% allowed. 51 Supply and erecting Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 of 11 mtr long, all as specified and shown on drawings including the followings:-(a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work complete. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work complete. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base.(e)Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block.(f) Painting of coping shall be cement base paint complete all as directed.(g) Embeded portion shall be painted with two coat of black bituminous paint complete all as specified and directed.Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately. 52 Supply and fix cable jointing kit for 1.1 KV grade cable for end termination jointindoor/outdoor type complete with jointing material heat shrink type and accessories suitable for 3.5/4 core XLPE armoured, aluminium conductor cable of size 70 to 95 sqmm complete all as specified and directed. 53 Supply and fix cable jointing kit for 1.1 KV grade cable for end termination jointindoor/outdoor type complete with jointing material heat shrink type and accessories suitable for 3.5/4 core XLPE armoured, aluminium conductor cable of size 240 sqmm complete all as specified and directed. 54 Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as directed. 55 M & L for DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installationand including glands and with 4 terminals for terminating oneincoming and outgoingUG cable of size 10/6 sqmm 2 core and fixed to the PSC/Steel Poles by means of suitable size of clamps with nut and boltswith suitable busbarall as spcd and directed. 56 S & F pole mounted enclouser made of UV stabilized,FR grade special moulding compound having facility duriation base switching ON / OFF of capacity 5 KW, singlephase, with suitable size of FI clamps 02 Nos with the following accessories and all as directed. (i)Contactor 40 amps.= 01 No. (ii) MCB 40 Amps(SP),10 KA ,240 volts. = 02 Nos(iii)NATURESWITCH-01 57 Supply and erecting Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 of 9 mtr long, all as specified and shown on drawings including the followings:-(a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work complete. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work complete. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base.(e)Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block.(f) Painting of coping shall be cement base paint complete all as directed.(g) Embeded portion shall be painted with two coat of black bituminous paint complete all as specified and directed.Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately. 58 M & L for cable route indicaor showing "MES HT U/G 11 KV " and route of cable with arrow (Embossed or engraved) made RCC in suitable shape and fixed in PCC block 1 : 3 :6 type C-2 using 40 mm gaded aggregate 60 cm X 30 cm in ground , 30 cm below ground level and 30 cm above ground levelto show clear indication of cable including painting the complete slab wih red paint and marking the engraved/embosed letters/arrow with white paint complete all as directed.Note :-Quoted rate shall be deemed to included the cost of excavation, returning, filling and removal of excavated earth upto a distance of not exceeding 30 mtr complete. 59 Materials and labour for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel strip 32x6 mm as earth lead soldered and rivetedto earth plate by means of nuts, bolts, check nuts & washers, of galvanizediron or steelwith connected to test point and testing on completion including 40 mm pipemedium grade for earth leadprotection from earth point to earth plate, including provnadequate quantity of charcoal dust mixed with35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth platewith 20mm bore GI Pipe medium grade for watering,GI check nut, funnel and wire meshwith and includingall necessary excavation& earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor. 60 M&L for preparation of new steel surface and applying two coat of aluminium paint over a coat of red oxide primer on HT pole, cross arms ,MS channel, angle iron frame work, bracing etc including numbering of poles with black paintcomplete all as directed. 61 Supply, installation, testing and commissioning of factory made powder coated (CPRI tested as per IS-8623) LT panel board cubical, outdoor type, degree of protection IP-51, weather, dust and vermin proof , cubical type made out of CRCA sheet 3 mm thick and doors and covers 2 mm thick, shrouds & partitionsshall be of minimum 1.6mm thickness. with base frame of angle iron 50x50x6mm suitable for 415 volts, 3 phase,50 Hz, 4 wire system with front and rear side openable with double shutters, hinged and locking arrangement and slanted roof. The size of panel boards shall be suitable for housing the accessories given here under. The switch gears in the panel shall be such arranged so as to facilitate their maintenance and ease of inspection at the same time a adequate degree of safety.Minimum clearance of25mm and 19mm respectively shall be maintained between phases/phase to neutral/phase to earth and between neutral to earth. When for some reason, these clearances are not available, suitable insulation shall be provided. All insulating materials used in the construction shall be non-hygroscopic type duly treated to withstand the effects of high humidity, high temperature tropical ambient service conditions. The switchgear panel shall be tested for the following-(a) Electrical and Mechanical operation test.(b) Insulation test at 2.5 KV for one minute.(c) Heat run test at rated current.(d) Megger test by 1000V megger The panel board shall comprise of following items with and including necessary connection complete all specified and directed. 62 (A) INCOMING:-(i) MCCB 320 Amp 4 pole 415 VoltsAC with thermal magnetc adjustable type 35 KA lcs = 100% lcu-01 Nos (ii) Aluminiumbus bar 600 Amps capacity of suitable length duly insulated with colour code- 04 Nos (iv) Digital voltmeter, square mouthed 96 mm square 0- 500 volts with selector switch-01 Nos(v) Digital Ammeter square mouthed 96mm square 0-500 Amps with CTs and selector switch-01 Nos (vi) Phase indicator lamp LED clustar type RYB (Set of Three) - 01 Set.(B) OUTGOING:- (i) MCCB 160 Amp 4 Pole 415 Volts AC with thermal magnetc adjustable type 35KA lcs = 100% lcu -04 Nos (ii) MCCB 63 Amp 4 Pole 415 Volts AC with thermal magnetc adjustable type 25KA lcs = 100% lcu -01 Nos(iii) Copper cable connection with lugs, aluminum cablegland for incoming & out going cables etc.Note:- Quoted rates are inclusive of following:-(i) Contractor will get approved the Drawing of panel from AGE(I). (ii) Plateform of suitable size in PCC 1:2:4 type B-1 minimum 40 cm below NGL and 45 cm above from NGL duly plastered in CM 1:3 , 5mm thick and painted with two coat of cement based paint. 63 WATER COOLER :Supply, installation, testing & commissioning of Water cooler fully Stainless steel(SS 304 grade), electric driven single phase 230 volt, BEE-5Star, 50 Hz having storage capacity 120 Ltrs & and nominal cooling capacity 60 Ltrs per hour, 100% copper cooling , as per latest versionincluding connection by means of water pipe line, inlet and outlet, PVC pipe connection with brass coupling, nuts at both ends and other necessary fittings including necessary electric connection with and including plug top 15 Amps from voltage stabilizer to water cooler complete all as specified and directed. 64 DESERT COOLER :Supply and fixing ofheavy duty desert cooler PVC body,3-side high efficiency honeycomb pads with dust filters for pure healthy air, powerful fan 15"" diameter with Robust weather resistant body for long life, Digital touchscreen & full function remote, Powerful 3 speed fan and empty water-tank alarm, Easily removable and cleanable cooling pads. Fully closable horizontal louvers, Float valve for auto water filling and lockable heavy-duty wheels, 4000 m³/hr air delivery low power consumption - 185 watts, storage capacity of tank should not be less than 50 litresand motor with thermal overload protection andincluding writing MES No. complete all as specified and directed.Note for WATER COOLER& DESERT COOLER Items:-(a)Minimum warranty 2 years on product, 10 years on compressor & 5 years condensor .(b)Item mfg date should not be older than 06 Months from installation date.(c)All items must have a permanent type vinyl sticker on outer body bearing following details and quoted rate are deemed to inclusive cost of sticker.(i)Machine Srl No._____________ (ii)MES No______________ (iii)Date set to work.____________(iv)PRB Page No ______________.(v) Location__________________(vi) CA No.________________________ 65 HOT WATER :Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed.
|