Tender For Provision Of Deficient Smqs At Aste Bangalore; 2 GENERAL SUMMARY NOTE: Schedule ‘A’ Part II to XIV are prepriced by MES under Ser No. 1 to 13. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. 3 Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’Part–II 4 Lumpsum price worked out by the contractor for “Internal Electric Supply as listed in Schedule ‘A’Part–III 5 Lumpsum price worked out by the contractor for “Site Clearance and Development as listed in Schedule ‘A’ Part - IV . 6 Lumpsum price worked out by the contractor for “Road / Path / Culvert as listed in Schedule ‘A’ Part - V . 7 Lumpsum price worked out by the contractor for Area Drainage as listed in Schedule ‘A’ Part - VI . 8 Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part – VII. 9 Lumpsum price worked out by the contractor for “Rain water harvesting” as listed in Schedule ‘A’ Part – VIII. 10 Lumpsum price worked out by the contractor for “External water supply” as listed in Schedule ‘A’ Part – IX. 11 Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part – X. 12 Lumpsum price worked out by the contractor for “Lift” as listed in Schedule ‘A’ Part – XI. 13 Lumpsum price worked out by the contractor for “Lightning protection” as listed in Schedule ‘A’ Part – XII. 14 Lumpsum price worked out by the contractor for “Fire fighting” as listed in Schedule ‘A’ Part – XIII. 15 Lumpsum price worked out by the contractor for “Demolition of P-45 & 46 Building (B & R portion)” as listed in Schedule ‘A’ Part – XIV. 16 Sch A Part - I : BUILDINGS OR WORKSDesign and Construction of Married Accommodation building in 7 storey (Ground+6 storey), stilt parkingframed construction with permanent specifications in RCC of grade as per structural drawings with AAC solid block masonry walls, ATT, PU based WPT, earthquake resistance as per latest IS, GRIHA 3 star rating certification etc complete all as specified and as shown on drawings. 17 Sch A Part - XV : Fittings / Fixtures & Misc items. INTERNAL WATER SUPPLYSupply and fix 15mm bore Kitchen sink tap, brass chrome finish dual flow patters with silicon black flexible hose swivel type complete all as specified and as directed. 18 Supply and fix 15mm bore washing machine tap, brass chromefor galvanised iron pipe, complete all as specified and as directed. 19 INTERNAL ELECTRIC SUPPLY Supply and fix surface mounted square panel light fitting 1ft x 1ft, 18W, 220Volts, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size and connected accessories etc complete all as specified and as directed. 20 Supply and fix Modular TV Socket, one module etc complete in all respect all as specified and as directed by engineer in charge . 21 Supply and fix Modular Telephone socket, RJ-11, one module etc complete in all respect all as specified and as directed by engineer in charge. 22 Material and labour for Telephone Wiring with unarmoured Solid annealed bare copper industrial cablein concealed of size 0.5 mm ,3 pair with PVC Conduit 25 mm diaetc complete in all respect all as specified and as directed by engineer in charge . 23 Material and labour for TV Wiring with unarmoured coaxial cable,RG-11in concealedwith PVC Conduit 25 mm diaetc complete in all respect all as specified and as directed by engineer in charge. 24 Material and labour for Mild steel Box for Telephone wiring including blocks , Suitable for 35 Pair etc complete in all respect all as specified and as directed by engineer in charge. 25 RAIN WATER HARVESTINGBoring holes 200mm dia in complete by mechanical in any type of soil / rocks complete all as specified and as directed. 26 Supply and fix 200mm dia HDPE PVC pipe in easing with PVC fitting cloth complete all as specified and as directed. 27 Supply and fix PVC vent cowl of size 200mm dia complete all as specified and as directed. 28 EXTERNAL WATER SUPPLYSupply install testing and commissioning of three phase12.5 HPcentrifugual pump sethaving maximum head 45 mtr withall as per manufacturer specification with suction size 80 mmx delivery size 65 mm fixed on common base plate with suitable foundation bolts and nuts grouted in and including PCC platform 1:2:4 type B2 using 40mm graded stone aggregate medium gradeand jointed with gaskets and nuts bolts etc inclusive of startercomplete all as specified and directed 29 Supply, fix, test and commissioning of Ductile iron pipes 100mm dia/bore with spigot and socket ends, centrifugally cast, class K-7, bearing ISI mark,in any length laid in trenches complete all as specified and directed 30 Material and labour for DI specials i.e bends, (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch, Y junction, double branch, tail piece, mechanical joints, flange specials, cross ( all socket and spigot) collars, caps and plugs. Upto 100 mm dia complete all as specified and as directed. 31 Material and labour for construction of brick masonry valve pit of size 60 cm x 60 cm x 60 cm (internal dimension) one brick thick wall in CM 1:4 on 100mm thick PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation, 15mm thick rendering in cement mortar (1:4) internally, externally up to 15cm below GL, providing valve pit cover made out of 3mm thick MS sheet duly welded with provision of hinges, handle and locking arrangement including 40 x 40 x 5mm angle iron frame fixed on top of valve pit by means of hold fast 150mm long, embedded in PCC block 1:2:4 type B-1 (20mm graded aggregate) of size 230 X 200 X 100mm, applying two coats of anti-corrosive paint over a coat of red oxide, zinc chrome primer after preparation of steel & iron surfaces including necessary excavation &earth work in hard/dense soil complete as specified and directed. 32 Material and labour for construction of brick masonry valve pit of size 90 cm x 90 cm x 90 cm (internal dimension) one brick thick wall in CM 1:4 on 100mm thick PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation, 15mm thick rendering in cement mortar (1:4) internally, externally up to 15cm below GL, providing valve pit cover made out of 3mm thick MS sheet duly welded with provision of hinges, handle and locking arrangement including 40 x 40 x 5mm angle iron frame fixed on top of valve pit by means of hold fast 150mm long, embedded in PCC block 1:2:4 type B-1 (20mm graded aggregate) of size 230 X 200 X 100mm, applying two coats of anti-corrosive paint over a coat of red oxide, zinc chrome primer after preparation of steel & iron surfaces including necessary excavation &earth work in hard/dense soil complete as specified and directed. 33 Supply and fix Cast Iron Air Valves with two air Outlets, 50 mm dia bore and fixing Up in cast iron water supply mains complete all as directed by EIC 34 EXTERNAL ELECTRIC SUPPLYDesign, fabricating, supply, installation, testing & commissioning of LT outdoor panel board 3 phase 4 wire system outdoor double door front and back opening type slopped canopy (hood ) on top extended 100 mm al around separate compartment for each control gear cable alley , provn of knock out type plates for various sizes of cable up to 120 sqmm 3.5 core in and out incoming and outgoing feeders duly marked, CPRI type tested fabricated out of 3.0mm thick CRCA sheetpainted with epoxy powder coated mat finish pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PV sleeved mounted on angle ironframe of 50x50x6 mm thick embedded in pack 1:3:6, 45 cm below ground level & 15 cm above ground levelconsisting of following and complete all as directed by Engineer in charge .- (TRANSFORMER LT PANEL) 35 Aluminium bus bar of 400 Amps capacity duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of class “F” class insulator4 Pole MCCB250 Amp 50 Hz 415 V with rupturing capacity 36 KA. (Incoming)4 Pole MCCB100 Amp 50 Hz 415 V with rupturing capacity 25 KA- 03 Nos(O/G to Bldg VTPN - 01 & Spare - 01 )4 Pole MCCB63 Amp 50 Hz 415 V with rupturing capacity 25 KA.-02 Nos (O/G for DG AMF Panel & APFC Panel)Volt meter & Ammeter each oneSelector switch-1No Indication lamps-3 Nos Multi functional Meter (LED display ) to read KWH ,Amps, Volts and frequency etc of each phase (3 PH,4W IPM 240 V(L-N)5A Class 1 FM 36 Design, fabricating, supply, installation ,testing & commissioning of LT outdoor panel board 3 phase 4 wire system outdoor double door front and back opening type slopped canopy (hood ) on top extended 100 mm al around separate compartment for each control gear cable alley , provn of knock out type plates for various sizes of cable up to 120 sqmm 3.5 core in and out incoming and outgoing feeders duly marked, CPRI type tested fabricated out of 3.0mm thick CRCA sheetpainted with epoxy powder coated mat finish pre wired with PVC insulated multi stranded copper conductor for controls and monitors , PV sleeved mounted on angle ironframe of 50x50x6 mm thick embedded in PCC 1:3:6, 45 cm below ground level & 15 cm above ground levelconsisting of following and complete all as directed by Engineer in charge .-:- (DG LT PANEL) 37 Aluminium bus bar of 200 Amps capacity duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of class “F” class insulator4 Pole MCCB125 Amp 50 Hz 415 V with rupturing capacity 25 KA0.-01 Nos (Incoming from main panel)4 Pole MCCB 100Amp 50 Hz 415 V with rupturingcapacity 25 KA.-02 Nos4 Pole MCCB 63Amp 50 Hz 415 V with rupturingcapacity 25 KA.-02 NosMCB SPN 16 Amps with rupturing capacity 10 KA-02 Nos (for local points)Supply and fix time switches 415 V three Phase of 20 Amp rating with contactor fitted inside steel enclosure -01 NoVolt meter & Ammeter each oneSelector switch-1No Indication lamps-3 Nos Multi functional Meter (LED display ) to read KWH ,Amps, Volts and frequency etc of each phase (3 PH,4W IPM 240 V(L-N)5A Class 1 FM 38 Supply and fix cable route indicator for HT cable made out PCC pole (0.2 x 0.3 x 1) MTRs (LXWXH) on HT cable 0.5 mtr depth grouted in the ground with suitable PCC work with writing HT cable/joint including earth work, PCC block ( 1:3:6) type C1 complete all as directed by EIC 39 Supply install testing 100 KVAR Automatic power factor correction panel in 4 steps (30 KVAR *2+ 2O KVAR*2 ) consisting of following :-(i)Manual Fixed Type Moulded Case Circuit Breaker (MCCB) with Thermal magnetic based release for over current and magnetic short circuit as incomer to APFC Panel01 No(ii)APFC RVC Relay for 6 steps- 01 No(iii)(30 KVAR *2+ 2O KVAR*2 )metallized polypropylene capacitor bank (iv) Capacitor duty contactor for switching on & switching offbank- 04 Nos(V) FAN for heat dissipation & cooling of capacitor bank - 01 No 40 Material and labourfor street light bracket made out of 25mm dia GI tubing medium grade upto 1.5 mtr long including bending, welding, drilling holes as required and fixing with flat iron clamps 32 x 6 mm thick (02 Nos) with suitable nut, bolts and washers to steel tubular/concrete poles/wall complete all as specified and as directed. 41 Supply and fix LT junction box for street light, sheet moulding compound (SMC) type with hinged type door and locking arrangement, off white colour, of size 300 x 200 x 105mm(internal)comprising of suitable size TPN Aluminium busbarwith 200 Amps Phase and Neutral terminals, and 01 No earthing terminal bolt and nut and connecting up cables with aluminium terminal lugs incl suitable size MS clamp2 Nos fabricated from 25x3mm MS flat iron and bolts, nuts and washers all as specified and as directed. 42 Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed. 43 Supply and fixaviation obstruction luminaries ,die cast aluminium housing with red polycarbonate dome ,integral driver of super flux 5 mm/IP-65 protection including fixing arrangement like GI pipe .clamp and saddles ,connectingup testing and commissioning complete all as specified and as directed 44 DG SETSupply, install and commissioning of Factory assembled Silent DG set with AMF panel of capacity 50 KVA , 40 KW , 1500 RPM , Turbo Charged, water cooled comprising ofsuitable Engine with microprocessor based Genset controller with silencer and canopy for soundless mode (sound level not exc level specified by central pollution control board) and alternator both mounted on a common base frame conforming to ISO-3046/BS-5514 andIS-10002 rated for 415 volts 50 cycles , 0.8 Power factor (PF) complete withresidential silencer, AVM pads , battery with its leads, first fill of lub oil and all engine accessories such as self starter, alternator/dynamo with suitable coupling and base frame on foundation as recommended by the manufacturers and consisting of other electrical component and maintenance free battey including suitable size of copper cable lead with terminal, all mounting accessory complete all as specified comprising with the following. 45 A. Engine (a) Vertical inline multicylinder, cold starting in accordance with BS-5514/IS-10002 at 1500 RPM including the following accessories.(i) Fuel tank(Suitable for capacity for minimum 12 Hrs run).(ii) Fuel filter(Ore & Micro).(iii) Fuel feed pump(Inline monoblock/PT type) with governor.(iv) Lub oil filter.(v) Lub oil cooler.(vi) Dry type/oil bathtype air cleaner.(vii) Exhaust Silencer(Industrial type).(viii) Radiator, Radiator fan & mounting.(ix) Fly wheel with starting ring.(x) Expansion bellows.(xi)Exhaust gas turbocharger.(xii) 12 Volt electric starter with 01 No maintenance free battery of suitable capacity.(xiii)Battery charging alternator(xiv)Engine control panel consisting with ON/OFF Start Key,Lub oil pressure guage, Battery charging ammeter,Coolant temp gauge, RPM Meter etc.(xv)Suitable flexible coupling 46 ALTERNATOR(i) Alternator, 3 phase, 415 Volts, 50 Hzs 0.8 PF 1500 RPM self excited, self regulated screen profected, drip proof alternator of capacity 50 KVA conforming to BSS 5000 (part 99) with insulation class H, single bearing and automatic voltage regulator accessoriesC. ACOUSTIC ENCLOSURE(i) Acoustic enclosure as per latest CPCB norms.(ii) Air inlet louvers specially designed to operate at rated load even at 50 deg C air inlet temp.(iii) Powder coated for long lasting service life and superior finish.(iv) Insulation material meets exacting IS 8183.D.ACCESSORIES(i) Baseframe fabricated from CRCA sheet of suitable thickness as per manufacturers design.(ii) Storage battery of suitable capacity as per manufacturers instruction mounted on angle iron frame of suitable size as directed. 47 CONTROL PANEL(a)The Genset controller as per manufacturers/ OEM design complete with internal wiring, bus bar etc and fitted with the following accessories :-(i) MCCB of suitable capacity as per OEM – 01 No(ii) Digital Ammeter – 01 No(iii) Digital Voltmeter 3 Ph 415 volts– 01 No(iv) Indicating lamps (LED type) (R-Y-B) – 01 setF. AMF PANEL(a)The AMF panel shall be separate panel outside of Acoustic enclosure and made of CRCA sheet duly fabricated, bus bar etc and fitted with the following accessories :-(i) MCCB of suitable capacity as per OEM - 02 Nos(ii) Contactor of suitable capacity as per OEM - 02 No(iii)Digital Ammeter with suitable CT of size as per OEM(iv) Digital Voltmeter 3 Ph 415 volts as per OEM(v) Indicating lamps (LED type) (R-Y-B) – 01 set(vi) Relay, timmer and other acessories as per manufacturer. 48 LIFTSupply and Fix MCCB DB VerticalTPN 12 WayA Frame, Including MCCB TPN as incomer,Double Door complete all as specified and as directed. 49 FIRE FIGHTING SYSTEMSupply and fix hose box for hose reel of 20 mm size of 30 meter length complete with coupling branch pipe and nozzle , MS sheet 2 mm thickness 50 Supply and fix branch pipe with nozzle of 20 mm dia for hose reel conforming to IS 8090 51 Supply and fix 63 mm dia 15 meter long hose conforming to IS 636 complete with male and female coupling conforming to IS 903 52 Supply and fix Automatic air release valve 50mm dia suitable for domestic water with 50mm gun metal stop valve complete 53 Supply and Fix Electric Motor Siren Conforming to IS 1941 suitable For three Phase 415 V Supply with motor not exceeding 3.75 KW Power and able to deliver 143 DB noise level. 54 Supply laying fixing and jointing by butt welding heavy duty class C MS ERW pipe of 100 mm bore confirming to IS 1239 including fitting i.e tees ,bends, elbows, union ,reducers, drain, flanges as required and fixing of pipe with MS clamps of suitable size on the walls and applying two coats of synthetic enamel of post office red colour paint over a coat of red oxide ,primer all as specified and as directed at site by engineer in charge 55 Supply & Laying of 2 Core, 1.5 Sqmm un armoured PVC insulated & sheathed copper flexible cablecomplete all specified and directed by Engr-in-Charge. 56 Supply, Installation, Testing & Commissioning of remote controlled terminal fault tolerant (Repeater Panel) complete all as specified and as directed by Engr-in-Charge. 57 Supply, installation, testing & commissioning of 6 zones System controller Panel with built-in DVR, having priority facility, music and Pre recorded fire evac message.Controller can be extended upto 100 zones complete all as specified and as directed by Engr-in-Charge. 58 Supply installation, testing & commissioning of 6 zone Call Station keypad with for PA system Announcement with goose neck microphone and with LCD display to announce all the zones or individual zones complete all as specified and directed. 59 Supplying, installing, testing and commissioning of 6 zone selector Talkback console and with CRCA sheet housing and control desk( rack) as required. Console shall have all call / call back facility and it should also work on AC single phase power complete all as specified and as directed by Engr-in-Charge. 60 Supply and fixing in position various signage boards at different locations of any sixe as per site requirement. It should containing the letters on 5mm thick self illuminated opaque PVC foam board of computerized letters, PVC non reflective self adhesive vinyl painted foam board of different sizes including all fixing arrangement complete all as specified and as directed by Engr-in-Charge. Note : The board shall be fixed on wall with suitable chromium plated screws including washers, the letter size shall be not less than 40mm with approved colour. 61 Supply and fix cable route indicator made out of 3 mm thick MS sheet of suitable size (As approved by Engr-in-charge)duly painted with two coats black paint over a coat of red oxide primer and writing cable direction, Nature of cable (i.e Fire Alarm Cable), size of cable (in SQMM), type of cable (OFC/PVC)with white paint, mounted on angle iron 40x40x3 mm, angle height 45 cm, (30cm below ground level) with PCC 20cmx20cmx15cm all as specified and as directed by Engineer- in- charge. 62 Supply and fix Fire Extinguisher water based type of capacity 9 Ltrs as per IS-15683complete. 63 Supply and fix Fire Extinguisher Dry chemical powder (ABC) type of 09 kg capacityas per IS-15683complete. 64 Supply and fix Fire Extinguisher Dry chemical powder (ABC) type of 04 kg capacity complete. 65 Supply and fix Fire Extinguisher Co2 type of 3.0 kg Capacity ( squeeze Grip operated, light weight as per IS-15683 66 Supply and fix fire bucket on mounted stand complete all as directed by engineer in charge 67 Supply and fix Fire Extinguisher Mechanical Form type 9 Ltrsas per IS-15683 complete 68 Supply and fixLED Edge Lit Fire exit signagewith a man running and arrow symbol and stair acrylic ,wall mounted 26x16x2cm, 8MM clear tranparent acrylic with battery back up,all signs and symbols used as per norms color green complete all as specified and as directed. 69 DEMOLITION OF BUILDING NO. P-45 & 46 (E/M PORTION)Taking down carefully point wiring complete including fixture and fittings from boards/outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. and making good to disturbed area all as specified and as directed. 70 Taking down existinglight fittings sketch type/ box type/building security light fitings complete by unscrewing from boards/walls completeall as directed. 71 Taking down existingMCB DBs SPN/TPN any type complete all as directed. 72 Taking down existingMCBs SP/SPN/TP/TPN any type complete all as directed. 73 Taking down existingsub main wiring including conduit complete, all as directed. 74 Taking down LED fittingsexisting 4 feet & 2 feet complete all as speciified and as directed . Note :Fitting shallbehanded over to MES Store. 75 Taking down ceiling fan/exhaust fan complete all as specified and as directed . Note : Ceiling fan/Exhaust fanshall be handed over to MES store 76 Taking down old unsv LT cable of 16 sqmm 3.5 core complete all as specified and as directed . 77 Taking down old earthing complete all as specified and as directed . 78 Schedule A Part - XVI (Outsourcing of services for operation of Lifts)Outsourcing of services for operation of electric lifts of any description (Passenger / load carrying capacity) complete all as specified and directed by Engr -In Charge for following shifts during the Defects Liability Period i.e two years after the completion of Phase I on all the days, in 3 shifts(from0600 hrs to 1400 hrs and from1400hrs to 2200hrs 2200 hrs to 0600 hrs) per day by employing one semi skilled operator with minimum 04 year experience in the trade for each shift and reliever on duty on all days incl Sunday and holiday and to attend and complete all tasks as specified and directed. NOTE: Operator is responsible for maintaining cleanliness of all lifts and surrounding area of the installations.
|