Tender For Fire Hydrants Scheme In Nagar Nigam Jhansi Under Avasthapna Nidhi From Jda - Civil Works - Design & Supply of all materials, T&P etc required for construction of specified capacity of 200 kl OHT with specified stagingas per following requirements:-Grading of OHT- M-35 Stair case- Seperate two column basedRCC staircase and 1 m wide balcony with box type RCC structure at the entrance of the staircase to protect the entry of unwanted persons & locking arrangement with MS door.Railings- 20 mm dia G.I. Pipe (medium quality steel tubes as per IS 1239) railing consisting of 3 rows of with posts height (50x50x6 mm MS angle) (1.0 m) of same pipe around stair case (both sides), balcony & at the top dome periphery, including epoxy 3mm thick coating above base coat, 65mm dia GI pipe (medium quality steel tubes as per IS 1239) ladder with FRP coating from opening of top dome to inside the tank and top of bottom dome. Supply and fixing of CI man hole cover with locking device at opening on the top dome to go inside the tank. Ventilator and Water level indicator - RCC ventilator with SS grill (10 sqm at the spacing of 30 mm) with steel mosquito mesh,electronic digitalwater level indicator with ultrasonic sensor including supply & fixing of solar energy arrangements. Vertical pipes- Inlet Pipe - 200 mm, outlet pipe - 250 mm, overflow - 200 mm & washout pipe - 100 mm C.I. D/F pipe as per design criteria upto 1 m beyond the apron, IVC/Kirloskar sluice valve on inlet, out let & at wash out pipe, duck foot bend, puddle collers and bell mouths. 10 mm thick & 150 mm wide S S plate clamp for fixing of verticle pipes with RCC columns (minimum 2 clamps between ends of each pipe). It also includes bye pass arrangement of OHT. The velocity in the pipes shall not exceed 1.5 m/s.Flooring, Apron & Drain- 100 mm thick PCC of 1:2:4 & 100 mm thick CC of 1:1:2 with 6 mm thick glass strips not more than 1 sqm area upto 2 m from outer edge of the columns of OHT, drain of size 200 mm x 200 mm with 150 mm thick CC of 1:1:2 including necessary sluice valve chambers and pipe line required for proper drainage of rain water from the campus.Sluice valve chambers- 3 nos. of sluice valve chamber (minimum size 1.5 x 1.5 x 1.5 m or larger size as per requirements of site) of brick work with 200 mm thick RCC slab. Two coat apex painting over one coat primer of approved colour of asian / berger paints after fixing of RCC surface with grinder, repair of minor holes, unevenness etc. Soil bearing capacity- Structure shall be design on the basis of maximum bearing capacity of 8 tonne/sqm or minimum as per actual on the basis of test report of soil bearing capacity.proper completion of work.( Including Cost of Testing for bearing capacity of soil for various sites of proposed OHT ) 2 Sub Zone of Proposed OHT 3 Proposed OHT in behind of Kotvali manikchauk 200 KL/ 22 m staging 4 COST OF RISING MAIN & BYE-PASS ARRANGEMENT COST OF FIREHYDRANTS IN JHANSI NAGAR NIGAM 5 Supply of the following sizes of D.I K-7 pipes ( red colour) with all jointing materails confirming to latest relevant I.S.8329/2000 & IS:4984:1995 or its latestamendment with couplers including complete in all respect F.O.R. destination including all taxes and insurance. 6 250 mm dia D.I.K-7 7 200 mm dia D.I.K-7 8 150 mm dia D.I.K-7 9 100 mm dia D.I.K-7 10 200 mm DI K-9 CWR to OHT including Bye Pass 11 Supply of following type of valves as per specifications F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection charges, packing and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete.Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 12 350 mm dia 13 250 mm dia 14 200 mm dia 15 100 mm dia 16 80 mm dia 17 Supply of the following sizes of C.I. Double flanged scour valves as per I.S. 780 class-1 working pressure 10 kg/Sqcm F.O.R Destination including all taxes and insurance. 18 80 mm dia 19 Supply ofsluice valves type fire hydrant post type consisting of 80 mm dia tail pieces, 80 mm dia duck foot band S.V. painting the hydrant fixing the saddle piece molten lead incluiding caulking and standard make iron coupling with cap and chain including female coupling etc. complete to IS.369/1995 at site including all taxes. 20 Excavation for pipe line in all type of rock by chieselling /blastingincluding supply ofblasting materials and stacking properly useful materials with lift up to 1.5 m and lead up to 50 m and including filling back, watering and ramming of excavated earth into the trenches and removal and disposal of surplus earth within 10 KM ( 50 % ) 21 In Kankar / Morum Shingle 22 In all type of rock 23 Dismantling and reinstatement of following type of surface including sorting out and staking of serviceablematerials of disposal of unserviceable materials up to a distance of 50 m. 24 INTERLOCKING ROAD 25 BITUMINOUS ROAD 26 C.C. ROAD 27 Carting from the store (up to 8 Km.) the following sizes of DI pipe and HDPE pipes specials to the site of work lowering them in to trenches and laying true to alignment and gradient including jointing, testing of pipeline and including supply of jointing material such as nut & bolts, rubber insertion, white lead etc. com- plate but excluding cost of trenching and cutting of pipes etc. For making of lengths but including making joints. 28 250 mm dia D.I.K-7 29 200 mm dia D.I.K-7 30 150 mm dia D.I.K-7 31 100 mm dia D.I.K-7 32 Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 33 350 mm dia 34 250 mm dia 35 200 mm dia 36 100 mm dia 37 80 mm dia 38 Carting of scour valves to the site of workslowering them into already Prepared trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete with Excluding values and specials Required but including the testing etc. complete Excluding values and specials required but including the testing etc. complete. 39 80 mm dia 40 Carting of 80 mm dia flanges fire hydrant of the site of workslowering them into already prepared trenches and fixing them In position including supply of Jointing materials such as bolt nut, Rubber insertion white lead complete with Excluding values and specials Required but including the testing etc. complete Excluding values and specials required but including the testing etc. complete. 41 Supply of all materials, labour T&P etc. required and construct surface box/masonry type sluice / scour valve chamber as per type design including supply and materials labour, T&P etc. complete. 42 Masonry type 43 Supply of all materials, labour T&P Etc. required and construct 750 x 750 x 1000 mm size fire hydrant chamber as per type design including supply and fixing the 500 mm dia CI manhole cover including fixing proprer MSbox with 30 m Lead of fire Hose for Fire fighting purpose with interconnect aregment As per required site condition & as per Direction ofengineer incharge. 44 Construction of thurst block in RCC 1:2:4 at bends & Tee in feeder main to DMA"sincluding supply of all labour, material, T&P etc. complete as per the details given below :-No. of DMAs - 4Total no. of bends & Tee - 12 (considering 3 no. bends & Tee in each DMA)Qty. of concrete - 12 x 0.5 cum = 6 cum. (considering 0.5 cum concrete at each bend) 45 Repairing of drain/ public ramp/other miscellaneous structures which are coming in alignment of pipe line and damaged during the laying of pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work. 46 Brick masonry in cement mortar 1:4 47 12mm thick plaster in cement mortar 1:4 48 RCC M-20 (including MS work) 49 Provision for crossing of Nalas (0.5mto 2.0 m width) for laying of pipe line including necessary specials, T&P and arrangement of diversion of water, baricatings etc required, with dismantelling of drains and reconstruction of same as per type design of the existing drain. 50 0.3 - 0.5 m 51 0.5 - 1.0 m 52 1.0 - 1.5 m 53 1.5 - 2.0 m 54 Barricading of pipe line trenches by using 2 m high hard MS barricading board 2.5x2.0 M, with red flags, Glow-caution boards, diversion boards & red lights. 55 Interconnection of rising main in existing water work campus with pipe 200 mm including fixing at top of the CWR slab Khanderao gatezone 56 Interconnection of pipe line to fire hydrentwith 80mm GI pipe 8m including all material required for work 57 Construction of two coloumn piller set for gurder including all labour material t&p etc complet with gurder installation. Etc comlete 58 Provision of shifting House Connection in Distribution main including Dismantling of Road, Supply, carting of Specials lowering them into trenches, fixing them including bailing out of water necessary labour, T&P etc. required for proper completion of works 110 mm to 250 mm pipe 59 Repairing of existing Fire hydrantincluding Supply and fixing of thematerials such as pipe , valve , bend and all specialas per site requirement including Replacement of fire Hydrant as per required site condition & as per Direction Engineer In Charge. 60 Lumpsump provision for repairing of leakage at different locationin differentdia and different type ofof pipelinein the water supply system located in the pipe line alignment(including tee , bend , special , pipe ( Tail Piece ) and socket ) 61 COST OF BOUNDARY WALL, GATE SITE DEVELOPMENT & APPROACH ROAD 62 Provide all materials, labour T&P etc. required for proper completion of work and construct Boundary wall. At OHT Campus 63 Provide all materials, labour T&P etc. required for proper completion of work and construct pillars as per type design and fixing of gate 3.6 m wide gate with 1.2 m wide wicket gate. 64 3.60 m wide gate with 1 m wide wicket gate 65 Provide all materials, labour T&P etc. required for proper completion of work and construction of interlocking approach road in water works campous. 66 At OHT Campus 67 Provide all materials, labour T&P etc. required for proper completion of work including levelling, dressing excavation and filling of earth where necessary for develop of water works site including carriage of earth. 68 At OHT Campus 69 Construction of 250X250 mm size drain at W/W sites 70 At OHT Campus 71 E and M Items 72 PUMPING PLANT AND ACCESSORIES FOR EXISTING CWR 73 SITC of Radial / mixed flow ISI marked water filled submersible motor pump sets suitable for CWR. The size of adopter fixed on top of the motor should exceed the top of coupler , for safegaurd the coupler. The construction material of motor and pump should match IS: 8034:2018 and IS 9283 guideline. The radial flow pumpset should perate at 5 star energy efficiency level of BEE and mixed flow pump set should operate at 3 star energy level of BEE, accompained by valid BEE certificate. Motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011 with required accessories including making connection suitable for CWR. The job includes labour part of lowering of riser pipe M.S. with rope, cables & pump, installation of complete fitting and accessories, jointing of electrical cables up to switch board. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect as per following specifications :- 74 840 LPM / 42 Mtr. HEAD / 15 HP MOTOR (2w+1s) 75 MAIN PIPING AND VALVES :-SITC of DI/DF 100mm Main piping complete of suitable size and quantity required for delivery side, bye pass arrangement and 150mm common Header upto 1 m. outsidethe pump house along with 150 x 100 x 150 mmDI/AF Tee (3 Nos), 150 mmDI/DF bend (03 Nos), 150 mm blind flange (01 Nos), DI/DF Pipes suitable sizeall necessary nuts, bolts, rubber packing, M.S Support for pipe, DI mechanical joints (04 Nos)etc. complete in all respect as per site conditions. 76 Motor operated actuator with sluice valve :- SITC of DI/DF sluice valve withElectrically integrated actuater (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 77 Actuator with Sluice Valve of size :- 100mm for pumps 78 Actuator with Sluice Valve of size :- 150mm for common header 79 Non return valve :- SITC of DI/DF Single Door/ Multi Door Non return/reflux valve conforming to IS:5312/2003(partI & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 80 100 mm Dia 81 150 mm Dia 82 CE/UL Certified Electromagnetic flow meter :- SITCofCE/ULFullBorecElectromagneticFlowMeterofapproved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable. 83 Size 150mm for common header 84 ELECTRICAL ITEMS:- 85 Supply& laying of 1.1KV grade XLPE insulated unarmured multi strand copper conductor cable of 3C x 10 sq.mmfrom control Panel to respective Motors with lugs etc. (copperconductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I / IS :7098 P I) 86 SITC OF MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitableto SCADA operation with RS485 Port consisting ofINCOMMING SECTION160A,50KA,TPN,ACB microprocessorbaseed (O/C,S/C)release-1 No , Spreader Links & Extended ROH for - 1 No, 3 Phase Digital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A- 1 Nos, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No. OUTGOING SECTION50 A, 50KA, TPN, MCCBmicroprocessorbased (O/C,S/C) RELEASE - 6 No, SpreaderLinks &Extended ROH for MCCB- 6 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 87 SITC of Air Cooled Digital soft starter suitable for the LT motor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including linecontactorssuitablefornextstandardhigherKWrating,Over& Underloadprotection,shortcircuit&singlephasingprotectionwith frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFF type and Start /Stop push button and Instrument Fuses, suitable to SCADA operation with RS485 Port rating capacity 15 HP / 11 KW 88 SITC of microprocessor based three phase sensing power factor correctionrelaypanel,IEC/EN61000-6-(2&4)having3CTsensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k settingaccordingtotargetedpowerfactorsetting,therelayshallhave digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have overloadprotection,novoltrelease,havingmultiparameterlikeKW, KVA, KVAR rating capacity of21 KVAR 89 SITC of Auto Phase reversal unit with inbuilt time delay & enclousare ( confirm to IEC:60947-1 & IEC:-60947-b-1) 90 100 Amp Rating 91 CE/UL Certified level transmitter for CWR :- SITCofCE/ULcirtifiedof RadarleveltransmitterCEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4" LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 92 CE/UL Certified Pressure transmitter for pumps and common header:- SITC ofCE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4" LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 93 Earthingwithcopperearthplate600mmX600mmX3mmthick including accessories, and providing masonry enclosure with cover plate havinglockingarrangementandwateringpipeof2.7metrelongetc. with charcoal/ coke and salt as required according to latest IS:3043 Supplyingandlaying50mmX6mmG.I. stripat0.50metrebelow groundas stripearth electrode, including connection/ terminatingwith nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 94 SITC of 1Ton capacity hand operated over head Travelling trolleycrane suitable fortravel length upto 6 Mtrs. with clear lift upto 3 M including gear type chain pulley block and geared Travelling trolley complete with all accessories . 95 Providing & fixing ofrubbermatsforelectricalpurposeasperIS:5424-1969, plain/chequered (1mX2m) - 10mm thickness 96 Providing & fixing of cable trench chequerred plate 97 SITC of Fire fighting equipments 4.5 Kg such as four nos. fire extinguishers ABC type, one set sand bucket with stand and grouting at site and one set Al strong plate and board. 98 Internal & External electrification of pumping station :- 99 Indoor Lighting 100 Surface Mounting 101 Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non - yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85%, with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt, THD < 10 % , p. f.≥ 0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K / 16000° / 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard 102 Suspended Mounting / Surface Mounting 103 36W LED light fixture 2"×2" with acrylic / prismatic front cover. 104 Fans 105 Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, Conform to all the performance requirements laid down in IS:374-2019 including all amendments, as applicable; & Carry BIS licensing (i.e. ISI marking) or Quality Certification such as ISO - 9001 or above. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc.) as required. 106 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) 107 Providing & Fixing of Heavy duty capacitor start, copper wind Double ball bearing 900/1400 RPM single phase Exhaust fan as per PWD specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. 108 450mm sweep (900/1400 RPM) 109 Outdoor Lighting 110 Supply and fixing of all in one solar LED light fixturewith integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate Battary wih BIS approved make. Luminaire should be secondary optic lences for better distribution with delivered efficacy of > 100 lumen per watt. Bidder shall have in house R & D Laboratory which is recognised by Ministry of Science & Technology Department , Govt of India/NABL.Bidder shall in house pole and luminaire manufacturing facility.Luminaire can be supplied with hybrid switch along with indicator to understand the source of power ( either from solar or AC supply).All the above should be integrated and should 1 system.. 111 Compact Solar LED Street Light- 60W(MONO)18V / 12.8V27Ah /40W 112 Complete wiring of Pump house, HT & LT room with 1.5 sqmm and 2.5 sqmm with multistarned copper conductor 1.1 KV with required 6A,16A switches,sockets,MCCB etc. 113 AUTOMATION FOR EXISTING CWR 114 CE & UL Certified PLC/RTU with redudant CPU & Power supply in IP 54 enclosure suitable to Communicate with GSM based modem unit with redudant CPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 115 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 116 CE/UL Certified Intelligent energy meters 117 CE/UL Certified Surge protector for control panel 118 CE/UL Certified 3 KVA UPS with batteries as per technical bid documents 119 CE/UL Certified 7" touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 120 Control Panel with IP-54 Protection, industrial grade for all equipment. Separate for control (24V) and power equipments 121 Cable 122 (i) Complete cabling upto 3 Pumps 123 Security Survelliance IP Camera with recorder (optional) 124 Installation, commissioning & testing 125 Local Control Station at Ex. CWR 126 CE/UL & BIS Certified industrial grade LED Monitor 65" with latest configuration as per specification 127 Desktop / PC with i5/i7 processor for as per technical bid documents 128 CE/UL Certified 3 KVA UPS with batteries as per technical bid documents 129 Full development version of required TAGS SCADA Software with customization of software for LCS as per requirement as per spec. mentioned in technical bid documents. 130 CE/UL certified local control room PLC with redundant CPU & power supply at LCS in IP 54 enclouseras per spec. mentioned in technical bid documents. 131 GSM based wireless/Broadband/Equivalent communication system for PLC capable to transfer & received data & gather from remote sites to control station, all accessories included signal enhancer anternna along with running expenses till DLP 132 CE/UL Certified firewall for network protection 133 Air conditioner 1.5 ton capacity 5 star rating with automatic voltage stabilizer 134 SURGE PROTECTOR FOR ETHERNET communication protection. 135 Furniture for LCS room as per requirement 136 CE/UL certified industrial grade Ethernet Swtich 137 Cannon/HP or equivalent Laser printer 1018 or equivalent 138 Security Survillance IP Camera with recorder (Optional) 139 Installation, Commissioning & testing including required furniture, A/C etc. 140 INSTRUMENTATION AND AUTOMATIONWORKS 141 Supply of Motor operated actuator with sluice valve at OHT outlet :- Supply of DI/DF Electrically integrated actuater with sluice valve (Totally enclosed,weather-proofanddustproofconstructionwithIP-67, protectionclass suitable for installationin any positionwithout lubrication,leakageorotheroperationaldifficultywithspecialgrease filledgearboxandsuitableformanualoperationforemergencywhich will automatically dis-engage on restoration of power to motor and with10wattsingle phase spaceheaterandcontinuouslocalmechanical positionindicatorandindividuallyreplaceablecountergearassembly and with two torque and four limit switches with S.S. flap and operated withgeardrivencamsandofrating250Volt,5Amp,AC/DC,torque switch dialand with TEFC squirrel cageinduction) operatedsuitable to SCADAoperationsluicevalvehavingbodydoorcoverof gradedincast irontoIS:210Gr.Fg.260bodyanddoorringsofSSASTMA743Gr.CF8 andbearingblockofleadedtinbronzetoIS:318Gr.LTB2hingepinof stainlesssteelAISI:431.ValvesgenerallyconformtoIS:5312.Flangesto bedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatictestpressureof10Kg./Cm2 forseatand15Kg./Cm2for body(PN-1.0)of following sizes 142 250 mm dia 143 Supply ofDI mechanical joint as per requirement and departments approved drawing and specifications, including machining and rubber ring and suitable for 16 kg/cm2 working pressure with required flanges of suitable side with nut and bolt etc. complete. The joint should have long bolts so that during normal working pressure there should be no sliding movement of sliding flanges LOF (length over flange) should not be less than 75% of dia at DMA inlet. 144 250 mm 145 Supply of CE/UL Certified level transmitter for OHT :- Supply of Radartype leveltransmitter with CEmarkedwith following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4" LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 146 Supply of CE/UL Certified Electromagnetic flow meter at OHT inlet :- SupplyofCE/ULFullBore ElectromagneticFlowMeterofapproved make for remote placesof following dia and specificationscomplete:Media: Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Processtemp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI316L/ HastelloyC276/ Tantalum, Lining Material : Hard Rubber/ Neoprene/ Poly-urethane(PU), Flange: SS /CS, FlangeStandard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Càst Aluminium,with anticorrosivepaint&providecompletely sealed (leak proof) constructionasperrequirement‘ofIEC 60529, Accuracy : + 0.5 % M.V. velocity0.3to10m/s,Transmitter/signaconvertor Enclosure :Die CastAluminium, Power Supply: 80-240 V AC-5OHz,Output1: 4-20 mA,Output2:Pulse,CommunicationOutput:RS485/Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable and also interfacing with PLC panel. 147 250 mm 148 Supply of CE/UL Certified Pressure transmitter at OHT inlet :- Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters and Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4" LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 149 10 KVA 3/1:1 Phase Rack Mountable Easy On_x005f_x0002_Line UPS HSN/SAC Code: -85049090 , SMF BATTERIES 12V-18 AH (EP Series) HSN/SAC Code: -85072000 Battery Rack for 20 Nos 12 V-17/18 AH Batteries HSN/SAC Code: -73269099 , interlink Connector for 10 KVA UPS - 240 V DC HSN/SAC Code: -85366990 150 Installation, cabling of OHT including all equipments with all power and control cable,testingand commissioning complete in all respect. 151 AUTOMATION OF OHT 152 CE & UL Certified PLC/RTUin IP 54 enclosure suitable to Communicate with GSM based modem unit withCPU & Power Supply with analog & digital parameter & features as specified for each ZPS/OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations with control panel as specified in tender technical specification. 153 GSM / GPRS based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories including with signal enhancer antanna made for pumping plant internet charges as specified in tender technical specification. 154 CE/UL Certified Intelligent energy meters 155 CE/UL Certified Surge protector for control panel 156 CE/UL Certified 1 KVA UPS with batteries as per technical bid documents 157 CE/UL Certified 7" touch screen suitable for communication with PLC/RTU for local display & control of process parameters. 158 Control Panel with IP-54 Protection, industrial grade for all equipment. Separate for control (24V) and power equipments 159 Cable 160 (i) Complete cabling 161 Security Survelliance IP Camera with recorder (optional) 162 Installation, commissioning & testing
|