Multiparameter Monitor For Screening And Nursing Stations With Mobile Support (Vital Signs Monitor For Screening And Evolution Of Adult, Pediatric And Neonatal Patients, For Use In Inpatient Units That Allows Monitoring Of Adult, Pediatric And Neonatal Patients. Minimum Technical Specifications: Screen With Color Display, Flat Screen, Touch-Sensitive Backlit Lcd/Tft Minimum 10” And Minimum Resolution Of 1024X798 Pixels. It Must Be Capable Of Measuring The Following Physiological Parameters: Pulse Rate; Non-Invasive Pressure; Pulse Oximetry And Axillary Temperature; 300 Bpm, Resolution Of 1 Bpm, And With Accuracy Of At Least ± 3 Bpm. Measurement Of O2 Saturation, With A Measurement Range Of At Least 1 To 100%, Resolution Of 1%, And With An Accuracy Of At Least ± 3% In The Range Of 70 To 100% With Any Of The Spo2 Technologies. Nellcor, Masimo, Fast Philips, Mindray Or Blupro Mandatory Temporal Temperature Measurement With Measuring Range Minimum 35°C–40°C, Resolution 0.1°C. Oscillometric Technology Monitoring Of Blood Pressure; Systolic Blood Pressure, With A Measurement Range Of At Least 30 To 270 Mmhg, A Resolution Of 1 Mmhg, And With An Accuracy Of At Least ± 5 Mmhg; Diastolic Blood Pressure, With A Measurement Range Of At Least 10 To 240 Mmhg, And With An Accuracy Of At Least ± 5 Mmhg; Average Blood Pressure, With A Measurement Range Of A Minimum Of 20 To 250 Mmhg, And With An Accuracy Of A Minimum ± 5 Mmhg With A Measurement Range Of 40 To 300Bpm; The Monitor Must Support Defibrillator Discharge And Provide Rapid Recovery; Have Audiovisual Alarms, With Adjustable Limits; Alarms For High And Low Oxygen Saturation, And High And Low Heart Rate; Visual Alarm For Low Battery Charge; Must Have Audiovisual Alarm For Sensor Disconnection Or Failure And Weak Pulse. Have Monitoring And Diagnostic/Screening Modes To Display Parameters; Simultaneous Display On The Screen Of Digital X-Ray Device - Command And X-Ray Generator; High Frequency - Multipulse; Minimum Power: 50Kw; Microprocessed Control System; Membrane Panel With Single Touch Keys; Minimum Kv Adjustment Range: 40 To 150Kv - With 1Kv Steps; Minimum Ma Range 20, 50, 100, 200, 400, 500, 630Ma; Automatic Fine/Coarse Focus Selection; Minimum Exposure Time: 0.001 To 5 Seconds; Minimum Mas Range: 0.25 To 630 Mas; Indication Of Parameters/Functions On The Digital Display Of At Least Kv, Ma And Mas; Electrical Supply – Three-Phase 220V/380V – 60Hz (Both) Without The Need For A High Transformer For Better Use Of The Room. Fixed Table With Floating Top; Radio Transparent Homogeneous Top With Minimum Load Capacity Of 250 Kg; Minimum Size Of 90 X 200 Cm; Minimum Longitudinal Displacement Of The Top Of +/- 66 Cm And Transverse: Minimum Of +/- 22 Cm; Electromagnetic Brakes For Transverse And Longitudinal Movements; Centering Indication System. Anti-Diffusion Grid Ratio 103 Lines / Inch; Focal Distance 100 To 180 Cm; Electromagnetic Brakes; Tray Enabling Self-Centering Of Chassis From 13X18 Cm To 35X43 Cm; Electrostatic Painting Finish. Tube Holder Stand: Floor/Table Type: Minimum Horizontal (Longitudinal) Displacement Of 190 Cm On Rails; Column Rotation -180°/+180° - Activated By Pedal; Tube Holding Arm: Minimum Vertical Displacement Of 124 Cm (Between Focal Points); Rotation
Contact Information
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 90749726
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.