Tender For Extension Of Apron At Kangra Airport-2024; 1 Carriage of material by mechanical transport (lead upto 4km): Lime, moorum, building rubbish 2 Carriage of material by mechanical transport (lead upto 3km): Earth 3 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift , as directed by Engineer-incharge.All kinds of soil 4 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. 5 Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc.in layersnot exceeding20cm indepth,consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 6 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation, trenches, plinth, sides of foundation etc. complete for all lift. 7 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size derived from natural sources) 9 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8(1 Cement : 4 coarse sand (zone-III): 8 graded stone aggregate 40 mm nominal size derived from natural sources) 10 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 11 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) 12 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 13 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc for mass concrete 14 Centering and shuttering including strutting, propping etc. and removal of form for : Walls any thickness including attached pilasters, buttresses, plinth and string courses etc 15 Centering and shuttering including strutting, propping etc. and removal of form work for :Lintels, beams, plinth beams, girders, bressumers and cantilevers 16 Centering and shuttering including strutting, propping etc. and removal of form work for :Columns, Pillars, Piers, Abutments, Posts and Struts 17 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 18 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 19 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 20 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) 21 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) 22 Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.Cement mortar 1:6 (1 cement : 6 coarse sand) 23 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 24 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) 25 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) 26 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) 27 Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 ltr/10 sqm) 28 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work 29 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work 30 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - In -Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 31 Demolishing brick work manually/ by mechanical means including stacking ofserviceablematerialanddisposalofunserviceablematerialwithin50 metres lead as per direction of Engineer-in-charge.In cement mortar 32 Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: Channels, angles, tees and flats 33 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 34 Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilometre, as per direction of Engineer-in-charge. 35 Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). 36 Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete.New work (Two or more coats) 37 Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete.Old work (One or more coats) 38 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 39 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. 40 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. 41 Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete450 mm dia RCC pipes. 42 Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete600 mm dia RCC pipes. 43 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating, dressing to camber and consolidating with road roller including making good the undulations etc. and and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 44 Preparation of granular sub-base by providing close graded material, conforming to specifications mixing in a mechanical mix plant at OMC, carriage of mixed material by mechanical transport to work site, for all leads and lifts, spreading in uniform layers of specified thickness with mechanical means including neatly leveling & dressing on prepared surface and compacting with vibratory power roller to achieve the desired density, complete and as per direction of Engineer-in-charge.With material conforming to grading II of Table I of Particular Specifications. 45 Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by mechanical transport to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base /base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 46 Providing and laying dry lean cement concrete with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 26.5 mm, aggregate cement ratio not exceed 15:1, aggregate gradation after blending to be as per specification, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant as per mix design, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonne vibratory roller, finishing and curing etc complete as per specification and direction of the Engineer-in-Charge. 47 Providing and laying Pavement Quality Concrete (PQC) produced in a batching and mixing plant having a Characteristic flexural strength i.e. flexural strength of 4.1 MPa at 28 days using Ordinary Portland cement of 43/53 grade or Portland Pozzolana Cement or Portland Slag cement conforming as per relevant IS codes, to be mixed at site, with 0.5% Super plasticizer by mass of cementitious material, fine aggregate, graded stone aggregates of 40 mm nominal size in appropriate proportion as per specification and job mix formula, laid in panels as per drawings/design as approved by the Engineer-In-Charge using Slip Form Paver or Fixed form paver including anti friction layer, joint filler board, making necessary provision for expansion, dummy and construction joint including filling with Polysulphide sealant of approved make, curing and making profile, complete as per direction of Engineer-in-Charge and specifications. The item for execution shall include all operations making pavement for intended use but not limited to following:(i) Polyethylene sheet (White in color) of thickness 400 micron conforming to IS: 2508 with 6mm thick fine sand layer.(ii) Providing and laying in position for expansion joint, 25mm thick pre-cut Synthetic joint filler board of approved make conforming to IS:1838(part 3)-2011, 45 mm from top (to be removed at the time of filling of Polysulphide sealant).(iii) Mechanically cutting dummy joints 3mm wide x 1/3rd thickness of slab which is subsequently widened to 10mm for the top 25mm depth and construction joints 10mm wide x 25mm deep as per specification.(iv) Providing and laying in position Polysulphide sealant of approved make conforming to BS-5212-1990 or IS: 11433-1995 in expansion/ construction / dummy joints including rounding off edges, applying 2 coats of approved primer compatible with the brand of Polysulphide and preparing the surface and applying masking tape along the edge of joint to prevent accidental spillage of sealant on top surface and to give neat finish to the sealant and removing the masking tape after application of sealant etc. as per the details below:(a) Expansion Joints of size 25 mm wide and 10 mm deep over 30mm dia expanded closed-cell Polyethylene foam back-up/backer rod of minimum density 22 Kg/Cum, as per manufacturer’s specifications and sketch at Appendix-‘A’.(b) Construction Joints of size 10 mm wide and 10 mm deep over 12mm dia expanded closed-cell Polyethylene foam back-up/backer rod of minimum density 22 Kg/Cum, as per manufacturer’s specifications and sketch at Appendix-‘A’.(c) Dummy Joints of size 10 mm wide and 10 mm deep over 12 mm dia expanded closed-cell Polyethylene foam back-up/backer rod of minimum density 22 Kg/Cum, as per manufacturer’s specifications and sketch at Appendix-‘A’.(v) Making profile as per DGCA CAR, panel drawing showing dummy, construction, expansion joints location.Note:(i) Areas inaccessible to paving equipment shall be constructed by manual/hand guided method. Areas in which manual/hand guided methods of construction become indispensable shall be got approved by the Engineer-in-Charge in writing in advance.(ii) The quantity of cement, type of cement and super plasticizer for one Cum. of finished concrete specified are for tendering purpose only. The contractor shall quote his rates assuming quantity of OPC cement as 360 Kg/Cum or 400 Kg of Portland Pozzolana Cement/ Portland Slag cement. In addition, if the actual quantity of cement & super plasticizer required as per laboratory mix design varies from the quantity assumed above, necessary cost adjustment for deviation in the quantity of cement and super plasticizer as per mix design, if any, shall be done as per the rate of cement and super plasticizer in actual supply voucher from manufacturer/authorized dealer at the time of execution. In the case of authorized distributor, the rate may be authenticated by the manufacturer. The rate of cement and super plasticizer exclusive of GST shall only be considered for payment. 48 Providing, Laying and Jointing of half cut hume pipe in saucer drain near boundary wall to channelize run-off during rains and enable the controlled movement of water away from boundary wall towards existing drains inside the operational area as per the directions and satisfaction of Engineer-in-Charge. 49 Construction of Embankment with available excavated earth at site with all lifts and leads in layers graded and compacted to meet the requirements as per MORTH latest specification etc., complete as directed by Engineer-in-charge. 50 Suppllying of stone dust and mixing the same with available soil uniformily at site as per the prescribed ratio to achieve CBR value of 15as per the direction of Engineer-in-charge. 51 Providing and fixing unplasticised rigid PVC pipe of 110mm dia (Working Pressure 4 kg/sq.cm) conforming to IS:13592 Type A,of requisite lengthin Brick wall / Stone Masonry/R.C.C. wall at the time of construction of wall, all complete including cutting, fixing, jointing, covering with cement mortar, etc as per direction of E.I.C. For weep holes in retaining walls. 52 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron "Y" shaped placed 2.4m or 3.00 m apart and with 4 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) 53 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)Note: Bricks to be supplied by department 54 Dismantling punched tape concertina coil in fencing including stacking within 50 metres lead. 55 Supplying and placing in position sand bags filled with fine sand in excavated area adjacent to Runway/ Apron/ Taxiway to cover full depth of excavation for safety of aircraft operations with red flag markings complete in all respect as per the directions of ATC safety team and EIC. 56 Shifting and Replacement of existing sand bags excavated area adjacent to Runway/ Apron/ Taxiway after completion of days work and before start of work the next day including cleaning of adjoining operational pavements for safety of flight operations complete as per the directions of ATC safety team and EIC. 57 Deduct for taking away of steel work on frames, shutters, trusses ,channels,beams,Tee,angles,bolts washers,barbed wires,concertina coils, bars in R.C.C. Standards post/ struts etc and other similar materials received from dismantling The material so received shall be the property of contractor after dismantling duly weighed/ measured before removing from the site in the presence of Engineer- in-charge. 58 Credit item for dismantling of old building and stores (Plan area of 485 Sqm) adjacent to Apron and Runway falling under proposed expansion of Apron and new Taxiway, disposal of all dismantled material/ malba beyond Airport premises, taking away all the salvage material clearing site neat & clean complete in all respect as per direction of Engineer In Charge.NOTE: 1. This is a credit item and quoted amount for this item shall be deducted from agency from BOQ amount for all other items.2. Agency is not allowed to quote less than Rs. 2,10,508 for this item. If any agency shall quote less than the this amount then the deduction from agency shall be Rs. 2,10,508 and L1 bidder shall be adjudged accordingly. 59 Supply of Elevated type Omni-directional Medium Intensity LED Taxiway Edge Light fitting suitable for Taxiway, Apron Edge Lights for use on a constant current series 6.6 A (Secondary rating), complete with Omni-directional Blue Lens with supporting mechanism, Lens clamping mechanism, breakable coupling, two pin secondary leads, base plate with neoprene gasket have 06 Nos bolt hole to receive M-10 stainless steel bolts alongwith other accessories including White LED with an integrated encapsulated electronic module as required and meeting the requirements of ICAO/FAA specifications. 60 Supply of 5 KV, 6.6 A/6.6 A, 50 Hz rubber encapsulated Isolating transformer suitable for individual series lamps airport lighting circuits. The transformer shall be designed to be water proof and suitable for direct burial in the earth or installation in a base, conforming to IS:12290 (latest edition) with up to amendments complete as per specifications attached.15 watts, 6.6A/6.6A 61 Supply of 6 Sqmm Plug and Receptacle of type I, class B connector & suitable field attachment with 5 KV grade XLPE insulated PE sheathed single core screened copper conductor cable as required. 62 Supply of CI transformer housing box, water tight round type metal container of outside dia 330 mm and of 450 mm height made of 10 mm thick all round except on top surface which is 15 mm thick cast iron moulding suitable to receive a light fitting-base plate on the top and having a clear opening of 220 mm dia hole centre and 6 nos tapped holes at hole centre of 260 mm to receive M-10 stainless steel bolts with light fitting base plate. The housing box shall have a clear hole at one side surface 75mm above bottom surface suitable to one no of 50mm dia, B class GI pipe, check nut, two numbers earth bolts of M 10 x 30 mm welded inside near the hole ( 4"" away from the hole centre), a drain hole at the bottom suitably tapped to receive 15mm dia "B" class GI pipe etc., complete as required. 63 Supply of 5kV single core, stranded copper conductor, XLPE insulated, PE sheathed, unshielded airfield lighting cable conforming to IS-7098 Part-2 as amended upto date. 1 core X 6 sq. mm. 64 Supply of 2X4 Sq.mm secondary lead EPR insulated, CPE sheathed, unshielded type secondary cable made out ofcopper conductor, upto 1 kV grade cable as specified suitable for AFL as required. 65 Supply of 5 KV, 6.6 A/6.6 A, 50 Hz rubber encapsulated Isolating transformer suitable for individual series lamps airport lighting circuits. The transformer shall be designed to be water proof and suitable for direct burial in the earth or installation in a base, conforming to IS:12290 (latest edition) with up to amendments complete as per specifications attached.45 watts, 6.6A/6.6A 66 Supply of 16 Sqmm Plug and Receptacle of type I, class B connector & suitable field attachment with 5 KV grade XLPE insulated PE sheathed single core screened copper conductor cable as required. 67 Supply of MS blanking/blind plate of outside dia 330 mm, 10 mm thick and having 6 nosholes tapped at hole centre of 260 mm to receive M-10 stainless steel bolts for use with CI Box including supplying of 6 nos M-10 stainless steel bolts. 68 Supply offollowing size of 1.1KV grade multicore stranded aluminium conductor XLPE insulated & PVC sheathed armoured cable as per IS: 7098 (Part-1) 1988 complete as required & as per enclosed specification.(4 core, 25 Sq.mm. ) 69 Supply offollowing size of 1.1KV grade multicore stranded aluminium conductor XLPE insulated & PVC sheathed armoured cable as per IS: 7098 (Part-1) 1988 complete as required & as per enclosed specification.(3.5 core, 35 Sq.mm. ) 70 Supply offollowing size of 1.1KV grade multicore stranded aluminium conductor XLPE insulated & PVC sheathed armoured cable as per IS: 7098 (Part-1) 1988 complete as required & as per enclosed specification.(3.5 core, 70 Sq.mm. ) 71 Supply offollowing size of 1.1KV grade multicore stranded aluminium conductor XLPE insulated & PVC sheathed armoured cable as per IS: 7098 (Part-1) 1988 complete as required & as per enclosed specification.(3.5 core, 120 Sq.mm. ) 72 Supply, installation, testing and commissioning of LED Guidance Sign Board of various sizes as per ICAO Annex.14 Vol.I (legends as approved by Engineer-in-Charge) made out of anodized 2mm thick Aluminum frame with suitable angle support and 1.5mm thick (minimum) Al. back cover, 4 mm thick polycarbonate sheet with glare free front face, the letter & symbol should be screen printed on inside of sign face made of self adhesive film of 3M applied on the inside face with required coloring, suitable arrangement shall be made for water tightness & locking arrangement,including supporting frangible legs & frame etc. signboard shall be uniformly internally illuminated with required number of LED lights with 24 V DC converter to achieve illumination level operated on input source 2.5A to 6.6A constant current without flickering complete as required and as specified 73 Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of nominal size 150 mm all round the frame with depth of 400 mm and total base of 150 mm thick cement concrete, 1500 mm from all edges of the board as per attached drawing including excavation, finishing and leveling of ground, etc. complete as required. 74 Dismantling of elevated type MIRL/HIRL fitting from the existing transformer housing box i/c removal ofisolating transformer, connectors kit, breakable coupling, base plate, lens, filters, lamps & other accessories and stacking the same carefully as required. 75 Installation, testing & commissioning of elevated MIRL/HIRL fitting on the existing transformer housing box i/c installation of breakable coupling, base plate, lens, filters, lamps, & other accessories including isolating transformer, alignment, levelling & earth connection etc. as required. 76 Making field connections of 5kV grade 6 sq.mm / 16 sq. mm XLPE insulated, PVC sheathed copper conductor single core cable with 5kV grade plug and receptacle of 6 sq.mm / 16 Sq. mm including filling the gap with water sealant material and HT tape suitable for field connections complete as required. 77 Installation of Transformer housing boxes by excavation of earth upto depth of 525 mm with a base concrete of 1:3:6 of size 630mm all round with 100 mm thick base and 150 mm thick concrete of 1:2:4 shall be filled all round CI Box, the top of concrete sloped awayincluding providing and fixing 250 mm long 15mm dia "B" class GI pipe with check nut for drainage of water complete as required as per the technical specification. (wherever the transformers boxes are to be installed in a line, the same has to be aligned in such a way that the centre fall in a straight line) etc. complete as required. 78 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as requiredUpto 35 sq. mm 79 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as requiredAbove 35 sqmm and upto 95 sqmm 80 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as requiredAbove 95 sqmm and upto 185 sqmm 81 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as requiredUpto 35 sq. mm 82 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in existing RCC / HUME /METAL/ HDPE pipe as requiredUpto 35 sq. mm 83 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in existing RCC / HUME /METAL/ HDPE pipe as requiredAbove 35 sqmm and upto 95 sqmm 84 Laying of 40 mm dia HDPE pipe alongwith all accessories like socket, bend, couplers etc. complete with fitting, cutting, jointing etc, direct in ground (90 cm below ground level) including excavation and refilling the trench but excluding ssand cushioning and protective covering etc., complete as required. 85 Laying of one no. PVC insulated & PVC sheathed AFL cable of 5 KV grade size upto 25 sqmm in the existing RCC/ METAL/HDPE/Open Trench pipe as required. 86 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4c x 25 sq. mm (28 mm) 87 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3.5c x 120 sq. mm (45 mm) 88 Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.4c x 25 sq. mm 89 Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.3.5c x 35 sq. mm 90 Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.3.5c x 70 sq. mm 91 Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.3.5c x 120 sq. mm 92 Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required. 93 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 94 Providing and fixing 25mm x 5mm G.I. strip in 40mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring washer excavation and re-filling etc. as required. 95 Providing and Laying of 6 SWG GI wire in existing Metal/ HDPE / Duct etc. as required. 96 Dismantling and shifting of existing 0.5 mtr long decorative light post including removal of top luminaire, base plate, fixing bolts, junction box etc. complete as required. 97 Dismantling and shifting of existing 3 Mtr. Long single arm decorative street light pole & bracket with all accessories including removal oflight fixture, cement concrete foundation, anchor plate, foundation bolts, etc. complete as required. 98 Dismantling, Shifting and Re-installation of existing Frangible LED illuminated Landing H with all accessories including installation of Aluminium frame, frangible legs, LED fittings, Control Box, internal & control wiring and bird deterrent dome, etc. complete as required. 99 Dismantling,Shifting and Re-installation of various sizes existing LED illuminated guidance sign board with all accessories including installation of polycarbonate sheet, Aluminium frame, frangible legs, angle support, base plate, foundation bolts, plug & receptacle, isolating transformer & other accessories, etc. complete as required. 100 Design, Manufacture , Supply, installation, testing& commissioning (D/M/S/I/T/C) of 16 mtr high mast with all accessories. Mast shaft shall be in 02 sections, hot dip galvanised and suitable for wind velocity as per IS 875 part 3. The system shall also include accessories in all respects i/c electrically operated raising and lowering gears double drum winch, head frame, steel wire rope 6mm dia(minimum), counter weights, top pulley arrangement, Lighting Arrestor, civil RCC foundation with excavation in soil, foundation bolts, anchor plates, nuts, washers, multicore copper conductor cable (Trailing Cable) of suitable current carrying capacity between top carriage and base terminal (inside Mast), Torque limiter,connector, manual handle,junction box, galvanised Lantern carriage arrangement suitable to install 06 nos of luminaires in asymmetrical arrangement, its controlgear boxes and counter weights as per detailed design and lightning finial. The mast shall have an out door type feeder pillar made out of 14 SWG, CRCA sheet with powder coated paint comprising of suitable rating one number incomer 32 AMP, single dial time switch, 16 amp TP contractor for the automatic switching of luminaries, power tool control with 2 no. 9 amp contractor and raise lower push button, interconnecting copper wiring, etc. as required suitable for operation on 415 V, 3 phase, 50 Hz, AC power supply for its operation, complete as required. 01 Job Includes-a) Construction of suitable foundationwith re-inforced cement concretefor the high mast as per site requirement with all materials and labour as required (Design of the foundation shall be vetted from Govt Engineering colleges / NIT / IIT"s)b) Supply of foundation bolts manufactured from steel along with nuts, washers, anchor plates and templatesc) Erection of the high mast with the help of suitable equipments and installation of lighting arrestor, luminaires and aviation obstruction light (supply of luminaires and obstruction light included in this item scope) with all wiring materials, wiring with suitable size three core flexible weather proof copper cable in PVC flexible conduits from Junction Box at lantern carriage to the individual fittings, as per specifications and labour as required.d) Testing and commissioning of the high mast lighting system.Note- Each High Mastto be provided with min 06 nos.LED flood light luminaries200 Watt LED light, 01 no of Single Dome LED Obstruction Light switch gears etc. as required. 101 Shifting and Re-installation of existing outdoor type feeder pillar of approx size (LxBxH=1.1m x 0.7m x 1m)
|