Tender For Mhis 2024- 25 Procurement Of Meteorological Equipments- Srg Fcs Equipments In Manual Gauging Stat ... in India
Tender Notice
TenderID
90647880
Tender Brief
Tender For Mhis 2024- 25 Procurement Of Meteorological Equipments- Srg Fcs Equipments In Manual Gauging Stations For Replacing The Obsolete Equipments Under Hydrology Sub Division, Kozhikode
Mhis 2024- 25 Procurement Of Meteorological Equipments- Srg Fcs Equipments In Manual Gauging Stations For Replacing The Obsolete Equipments Under Hydrology Sub Division, Kozhikode Mhis 2024- 25 Procurement Of Meteorological Equipments- Srg And Fcs Equipments In Manual Gauging Stations For Replacing The Obsolete Equipments Under Hydrology Sub Division, Kozhikode , Supplying Of Rain Gauge - Non Recording , 1.1 Conditions & Requirements • The Rain Gauge Shall Be Of Such A Design That It Operates Reliably And Accurately Under The Prevailing Environmental And Weather Conditions. • The Rain Gauge Shall Be Easy To Operate And Maintain. • The Rain Gauge Shall Be Supplied With The Accessories As Needed For Effective Deployment. • All Materials On The Rain Gauge Shall Be Non-Corrosive. • The Locking Ring Shall Be Of Rigid Plastic • The Rain Gauge Shall Have Smooth And Permanent Surface Finish To Minimise Evaporation Losses. • The Minimum Expected Lifetime In Open Field Shall Be 15 Years. • All Openings Of The Rain Gauge Shall Be Covered With Stainless Steel Net To Protect Against Any Insects Entering Inside. • The Rain Gauge Shall Comply With Is 5225-1992 1.2Specifications I. 200 Cm Model Collecting Area 200 Cm2 Id Of Rim 159.6 Mm Collecting Bottle 2 Litres Nominal Capacity 100 Mm Rain Measure For 10 Mm Rainfall, Graduation Etc. According To Is 5225-1992 Ii. Materials Base And Collector Preferably Frp Rim Of Collector Aluminium Or Gun Metal Iii. Accessories • Collecting Bottles Of 4 Litres For 200 Cm2 Collector , Supplying Ofsunshine Recorder , 2.1Conditions & Requirements • The Sunshine Recorder And Cards Shall Comply With Is 7243-1974 2.2 Specifications Size Base 200 Mm, Sphere Radius 79.6 Mm Base Good Quality Marble Or Similar Stone, Black Or White Sphereuniform And Well Annealed Glass And Having A Focal Length Of 74.9 ± 0.25 Mm Bowl Tin Bronze Pivot Brass Sunshine Cards, Made Of White Paste Board Propertieswhen Dryafter Immersion Inwater For 18 Hours After Drying Length Down Board 127 Mm127 Mm Not Less Than 125.7 Mm Width Across Board25.4 Mmnot More Than 25.9 Mm Not Less Than 25.1 Mm Thickness0.43 Tonot More Than 0.76 Mm 0.48 Mm , Supplying Ofcounter Type Anemometer , 3.1 Conditions & Requirements • The Instrument Shall Be Of Such A Design That It Operates Reliably And Accurately Under The Prevailing Environmental And Weather Conditions. • The Instrument Shall Be Easy To Operate And Maintain. • The Instrument Shall Be Supplied With The Accessories As Needed For Effective Deployment. • All Materials On The Instrument Exterior Shall Be Non-Corrosive. • The Instrument Shall Have An Expected Technical Lifetime Of Not Less Than 10Years. • An Operator’S Manual, Related To The Type And Model Of The Instrument, Shall Be Part Ofthe Delivery. • A Suitable Non-Reset Direct-Drive Revolution Counter Adding One Count For Each One- Tenth Revolution Of The Drive Shaft In One Direction Shall Be Used. • The Ratio Between Gears Shall Be Such That 1 Count Equals 100 M/S. • The Anemometer Shall Comply To Is 5912-1970. 3.2Specifications I. Sensing Range 50 M/S Accuracy Up To 2.5 M/S, 0.25 M/S Above 2.5 M/S, 10% Fs Ii. Materials Cups Copper Or Aluminium Sheet 0.71 Mm Thickness Centre Spindle Stainless Steel Rod Worm On Spindle Manganese Bronze Alloy Worm Wheel Hard Brass , Supplying Of Hygrograph, Hair String Type , 4.1 Conditions & Requirements • The General Arrangement And Main Dimensions Of The Hair Hygrograph And Charts Shall Comply With Is 5900-1970. 4.2 Specifications Range 0 To 100% Rh Accuracy Above 20%:5% Rh Recording Resolution ± 0.2% Rh Housing Material Frpor Aluminium Recording Mechanismdrum, Driven By Clockwork , Supplying Of Thermograph, Bimetallic Type , 5.1 Conditions & Requirements • The General Arrangement And Main Dimensions Of The Thermograph And Charts Shall Comply With Is 5901-1970 5.2 Specifications Range -20 To 60 °C Accuracy1 °C Recording Resolution 0.2 °C Housing Material Frp Or Aluminium Recording Mechanismdrum, Driven By Clockwork , Supplying Ofevaporimeter, Us Class A Pan , 6.1 Conditions & Requirements • The Pan Shall Comply With Is 5973 - 1998. • Civil Works Will Be Finalised In Collaboration With The Supplier. 6.2 Specifications I. Pan Size1.22 X 0.255 M (Diameter X Height) Accuracy Of Reading0.1 Mm Pan Evaporimetercopper Sheet Of Thickness 1.0 ±0.1 Mm Point Gauge And Still Well Brass Ii. Measuring Cylinder Material Clean Cast Seamless Acrylic Plastic Tubing Or Brass Sheet Bottom Plate Acrylic Plastic Sheet Thermometer Clampbrass Platform Rot Resistant Timber Treated With Creosote Or Other Effective Wood Preservative Inner Diameter122 Mm Graduationin Cm. Warranty: 3 Year Comprehensive For All Equipments As Detailed Above
Contact Information
Contact Person
Assistant Executive Engineer
Address
Assistant Executive Engineer, Hydrology Sub Dvn, Paroppady, Kozhikode
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 90647880
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.