Bids Are Invited For Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - As per tender document; Sl No 1 Heater removal Identification of MI heaters at site checking healthiness removal of heater and terminal boxs straightening the heaters pa.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - As per tender document; Sl No 2 Heater laying Shifting MI heater cables from stores contractor custody mock up trial laying at identified pipe location component as pe.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - As per tender document; Sl No 3 Terminal box fixing Shifting Field Terminal Boxes FTB from stores contractor custody and fixing on cladding FTB shall be fixed over the .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - As per tender document; Sl No 4 Providing and fixing double Tubular scaffolding system using HFrames APS system or cup lock type conventional staging with 40mm dia MS .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - As per tender document; Sl No 5 Fixing of field cable trays of size up to 200 mm width over the concrete walls floors ceiling as per site requirement by providing nece.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - As per tender document; Sl No 6 Shifting and Laying of 2C 2 point 5 sqmm copper sheathed mineral insulated copper conductor cable from group junction boxes to heater .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - As per tender document; Sl No 7 End termination of 2C 2 point 5 Sqmm MI cables with suitable glands sleeves etc Supply of termination kit is in the scope of supply and t.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - As per tender document; Sl No 8 Shifting and Laying of stranded Al Cu conductor HRPVC XLPE insulated Armoured unarmoured and PVC outer sheathed cable of outer dia upto .. , Repair, Maintenance, and Installation of upto .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - As per tender document; Sl No 9 Glanding stranded Al Cu conductor HRPVC XLPE insulated Armoured unarmoured and PVC outer sheathed cable of outer dia upto 40mm sizes; As.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - As per tender document; Sl No 10 Termination of stranded Al Cu conductor HRPVCXLPE insulated Armoured unarmoured and PVC outer sheathed cable of outer dia up to 40mm s.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - As per tender document; Sl No 11 Supply of finned U type rod heater rated 2kW 240V 1 point 05m as per specification PFBR 54400 SP 1018 R0 from OEM ie Ms Elmec Heaters an.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - As per tender document; Sl No 12 Supply of finned U type rod heater rated 5kW 415V 1 point 2m as per specification PFBR 54400 SP 1018 R0 from OEM ie Ms Elmec Heaters and.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - As per tender document; Sl No 13 Erection of finned U type rod heater rated 3kW 5kW in heater banks The scope includes shifting of heater removal of failed heater from .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - As per tender document; Sl No 14 Supply of Kanthal A1 12SWG wire from authorised suppliers The scope includes transportation and bringing inside NICB BHAVINI with submis.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - As per tender document; Sl No 15 Supply of beads for Kanthal A1 12SWG wires from authorised supplier The scope includes transportation and bringing inside NICB BHAVINI w.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - As per tender document; Sl No 16 Erection of Kanthal A1 heaters after assembling with beads to required length at required pipeline equipment as per directions of EIC T.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - As per tender document; Sl No 17 Supply of 300W 230V 19 x 500mm rod type cartridge heater from OEM ie Ms Elmec Heaters and Controllers or his authorised supplier as per .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - As per tender document; Sl No 18 Supply of 500W 230V 19x750mm rod type cartridge heater from OEM ie Ms Elmec Heaters and Controllers or his authorised supplier as per gi.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - As per tender document; Sl No 19 Erection of 300W 500W rod type cartridge heater at various heating jackets The scope includes shifting of heater removal of failed heat.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - As per tender document; Sl No 20 Supply of multilayer quartz yarn insulated Double run and Stainless Steel braided Cord heaters as per given technical specification; As .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - As per tender document; Sl No 21 Supply of multilayer quartz yarn insulated Double run and Stainless Steel braided Cord heaters as per given technical specification; As Total Quantity :
|