Tender For Nagar Palika Parishad Bulandshahr water supply Reorganization scheme ( Zone- 1, 2, 3 & 5),District Bulandshahr,Uttar Pradesh - PART-A (Nagar Palika Parishad Bulandshahr water supply Reorganization schemeZone- 1) 2 Civil Work 3 Construction ofUNDER GROUND RESERVOIR,750 KLin M-30 grade of concrete. 4 Supply of all materials labour T&P etc. complete and construction of R.C.C. (M30 Grade) CWR of 750 KL capacity awith main components, excluding cost of soil testing. 5 All the components of C.W.R will be casted in M30 concrete with cement, coarse sand and approved stone grit as per I.S. 11682 and I.S.456 6 Minimum depth of foundation below original ground level will be 4.5M 7 Seismic effects and wind load should be taken into consideration as I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure (this area is in seismic Zone IV and high damage risk zone for wind) 8 The above cast of C.W.R has been assumed that ,the bearing capacity of soil has been taken as 7 M.T.sqm. 9 Proper ventilator at top dome in circular shape of 8 m dia. along with an R.C.C. cover of minimum 1.50m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia.The space between top dome and R.C.C. cover should be covered with mosquito net of standard quality along with expanded metaled jali. 10 Water level indicator fabricated with good quality minimum 45mm x 45mm x 6mm M.S.angle and 3mm thick 6mm flat M.S.sheet. The indicator board scale made of 3mm thick M.S. plate should have a clear width of minimum 25cm painted with good Asian paint. It should also consists of 3mm brass wire rope minimum 4 smooth pulleys about 8 cm dia with guides,15cm dia copper ball float which shall be completely water tight suitable pointer of brass etc. 11 Lightening conductor as per I.S.S.2309 of its latest amendments of latest electricity rules. It should consist proper elevation rod with 5 or more fork points proper down conductors of prescribed metal of proper size prescribed by ISS 2309-1969 and ISS 3013-1966 12 C.I. manhole of min 60x60cm size made of M.S.channel section with adequate cover made of M.S. sheet of minimum 3mm thickness hinged with manhole with locking aarrangement.This manhole should be fixe at top dome at proper place. 13 Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit under each duck foot bend to support the vertical pipes. These bed blocks should supported on the raft not on the soil . 14 Painting of all concrete surface and steel pipe works with three coats of approved cement paint and anticorrosive paints. 15 Construction of pump house, chlorinating room,MCS room, Boundary Wall with gate and approach road works 16 Supply of all materials and construction of pump house of size (3.6 m x 3.0 m x 3.0 m) cum chlorinating room size (1.80mx 2.60 m x 3.00 m) . (As per type design of UPJN (Urban). 17 Construction of Stilling chamber (1.50 m x 1.50 m x 1.00 m) and V Noch for bye-pass Arrangement of Tubewells complete in all respect as per direction of Engineer in Charge. 18 Construction of MCS at NPP Bulandshahr centralized control room including supply of all materials, labour, T&P etc. complete in all respect as per direction of Engineer in Charge. 19 Construction of boundary wall around water works compound.(As per type design of UPJN (Urban)). 20 Supply and fixing 3.6M & 1.20M wide MS Gate with pillers including fabrication and supply of steel and construction of boundary pillars etc. complete for pump house complete in all respect as per direction of Engineer in Charge. 21 Supply & laying of 80mm cement interlocking tiles for approach road including supply of all materials, labour, T&P etc. complete in all respect as per direction of Engineer in Charge. 22 Construction of 300x300mm size drain including supply of all materials, labour, T&P etc. complete in all respect as per direction of Engineer in Charge. 23 Laying of Rising Main pipe line & appurtenent works 24 Excavation of earth in ordinary soil (loam, clay or sand) for laying of pipe line including refilling, ramming, dressing, leveling of trenches in 30 cm layers anddisposal of surplus earth for different size of pipe lift up to 1.5m and 500 m awayas per direction of Engineer in Charge . If any Utilities are damaged during excavation (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work. 25 Supply of D.I. pipe line into trenches true to alignment & agradient including Supply of D.I. D/F specials, F.O.R. destination and all taxes and insurance etc. cost of all labour, T&P, jointing, materials,specials, testing of pipe line etc. complete. 26 D.I. pipe Class-K-9 27 200 mm dia 28 450 mm dia 29 Carting laying & jointing of D.I. pipe line into trenches true to alignment & agradient including cost of all labour, T&P, jointing, materials,specials, testing of pipe line etc. complete.If any Utilities are damaged during carting or laying or jointing (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work. 30 D.I. pipe Class-K-9 31 200 mm dia 32 450 mm dia 33 Supply of following size and carting upto site of work, lowering, fixing and jointing of followingfittings in trenches including cost of all materials such as rubber packing, nut bolts etc. complete work. 34 C.I.D/F Sluice Valve IS 780-1984 35 450 mm dia 36 THRUST BLOCK 37 Provision forR.C.C. Thrust Block with cement, coarse sand & 20 mm gauge stone ballast in proportion of 1:1.5:3 in pipe line including supply of reinforcement and its fixing and binding the same with 0.50 mm thick binding wire on position and necessary centering & shuttering complete for proper completion of work including supply of steel and wastage etc. 38 Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. 39 CC Road 40 Bituminous Road 41 Interlocking Road 42 Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. 43 CC Road 44 Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) 45 Interlocking Road (Using 60% old tiles including spreading of local sand and base concrete in 1:6:12 ,10 cm thickness) 46 Provision for crossings of nalas & culvert including sifting of telephone cables etc. Along the alignment of pipeline including supply of C.I. tyton pipe andspecials etc. complete. (3.0 M.Wide Road) 47 Sluice Valve Chamber (Masonary Type) 48 Laying of Distribution pipe line & other appurtenent works 49 Excavation of earth in ordinary soil (loam, clay or sand) for laying of pipe line including refilling, ramming, dressing, leveling of trenches in 30 cm layers anddisposal of surplus earth for different size of pipe lift up to 1.5m and 500 m awayas per direction of Engineer in Charge . If any Utilities are damaged during excavation (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work 50 Supply of following size of pipes including all types of specials, railways frieght and cartage up to store , all taxes and duties complete as per direction of Engineer-in-charge. 51 HDPE Pipe (PE-100) 52 110 mm dia 53 140 mm dia 54 160 mm dia 55 DI Pipe Class K-7 56 200 mm dia 57 250 mm dia 58 300 mm dia 59 Carting ,laying and jointing of the following sizes of pipes into the trenches includingall types of specials, cost of all jointing materials,making interconnection & specials, labour and T & P , testing etc. completeas per direction of Engineer-in-charge.If any Utilities are damaged during carting or laying or jointing (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work 60 HDPE Pipe (PE-100) 61 110 mm dia 62 140 mm dia 63 160 mm dia 64 DI Pipe Class K-7 65 200 mm dia 66 250 mm dia 67 300 mm dia 68 Supply and fixing & carting of following types of fittings including railway frieght, cartage up to site, all taxes and duties etc. complete. 69 (A) C. I. Sluice Valveas per latest IS specifications 70 100 mm dia 71 125 mm dia 72 150 mm dia 73 200 mm dia 74 250 mm dia 75 Scour Valve 80 mm dia 76 Air Valve 20 mm dia 77 Fire Hydrants 80 mm dia 78 Supply of all materials, labour, T&P for construction of following types of chambers as per departmental drawing & design. 79 Sluice Valve Chamber (Masonary Type) 80 Sluice Valve Chamber (Surface Box Type) 81 Fire Hydrant Chambers 82 Air Valve Chambers 83 Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. 84 B.O.E. 85 C.C. Interlocking Tiles Road 86 C.C. Road 87 Bituminous Road 88 Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. 89 B.O.E Road (60% old and 40% new Bricks) 90 Laying of 80mm thick C.C. Interlocking Tiles Road with 40% new Tiles including dressing surface and including supply of tile,including all labour T&P etc. required for proper completion of work. 91 P.C.C. 1:6:12 in cement course sand and 40 mm th. Stone ballast including filling of jointing with local sand spreading and blinding coat of 10 mm to 25 mm deep of local sand over the entire surface and including all labour T&P etc. required for proper completion of work. 92 CC Road (100mm thickness of1:2:4 cement concrete ) 93 P.C.C. 1:4:8 in cement , course sand and 40mm thick stone ballast 94 Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) 95 Provision for crossings of nalas & culvert including shifting of telephone cables etc. along the alignment of pipeline including supply of C.I. tyton pipe andspecials etc. complete in all respect as per direction of Engineer in Charge. 96 (250 -350mm dia) upto 3.0 M 97 (90-100mm dia) upto 3.0 M 98 Making New Water House Connection with Distribution main including Dismantling & permanent reinstatement in all types of road , supply , carting of specials lowering them into trenches, fixing them including bailing out of water necessary excavation for connection including all labour , T&P etc. required for proper completion of the works as per direction of engineer - in- Charge. 99 For 90 mm to 500mm dia (HDPE Pipe) 100 Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. 101 B.O.E. 102 C.C. Interlocking Tiles Road 103 C.C. Road 104 Bituminious Road 105 Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. 106 B.O.E Road (60% old and 40% new Bricks) 107 Laying of 80mm thick C.C. Interlocking Tiles Road with 40% new Tiles including dressing surface and including supply of tile,including all labour T&P etc. required for proper completion of work. 108 Cement Concrete Road (100mm thickness of1:2:4 cement concrete over base of 100mm thickness of 1:4:8 Lean concrete) 109 Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) 110 Maintenance works 111 Repairing of OHT 680KL/18 M staging due to seepage in bottom dome, conewall & vertical wall after chiseling the loose concerete and ensuring water tightness of the OHT & repairing of 200 mm to 500 dia sluice valveincluding Scrapping and chiseling of plaster, providing and applying one coat of slurry of hydrophilic in nature for waterproofing treatment from the internal surface of Over Head Tank, required thickness plaster with chemical coding, supply and fixing of scaffolding, painting, colour washing, with Asian Apex Paint, stacking/proper disposal of dismantled plaster material, repairing of staircase including supply and fixing of GI pipe hand rail, vertical post and also repairing of minor defect in landing, riser and tread, Supply & fixing of Proper ventilator at top dome in circular shape along with an R.C.C. cover of minimum 1.50m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia., Lightening conductor as per I.S.S.2309 of its latest amendments of latest electricity rules, C.I. manhole of min 60x60cm size made of M.S.channel & Painting of all concrete surface and steel pipe works with all labour, material T&P complete in all respect as per direction of Engineer in Charge. 112 Repairing of OHT 2200KL/22 M staging due to seepage in bottom dome, conewall & vertical wall after chiseling the loose concerete and ensuring water tightness of the OHT & repairing of 200 mm to 500 dia sluice valveincluding Scrapping and chiseling of plaster, providing and applying one coat of slurry of hydrophilic in nature for waterproofing treatment from the internal surface of Over Head Tank, required thickness plaster with chemical coding, supply and fixing of scaffolding, painting, colour washing, with Asian Apex Paint, stacking/proper disposal of dismantled plaster material, repairing of staircase including supply and fixing of GI pipe hand rail, vertical post and also repairing of minor defect in landing, riser and tread, Supply & fixing of Proper ventilator at top dome in circular shape along with an R.C.C. cover of minimum 1.50m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia., Lightening conductor as per I.S.S.2309 of its latest amendments of latest electricity rules, C.I. manhole of min 60x60cm size made of M.S.channel & Painting of all concrete surface and steel pipe works with all labour, material T&P complete in all respect as per direction of Engineer in Charge. 113 Repairs of Existing Pump House including Supply of all materials, labour, T&P, complete 114 Repairs of boundary wall Supply all materials, labour, T&P etc. Required for proper completion of work complete in all respect as per direction of Engineer in Charge. 115 Interconnection in existiing distribution main with supply all material ,specials labour dismantling and reinstatementof all types of road etc complete 116 E & M Work 117 E/M WORK OVER EXISTING TUBEWELL NO.1(SHAMSHAAN GHAT NEAR KALI NADI) AT ZONE- 1A 118 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 119 SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH (pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect. (suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steady state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. 120 Replacement of damaged control and power wiring due to shifting of all equipement from defucnt TW No. 20 to Shamshaan Ghat TW 121 Dismantling of existing pumping plant for installation of water level indicator. 122 Installation of existing pumping plant including commissioning & testing complete. 123 Shifting of all SCADA instruments from TW No. 20 to rebore TW Shamshaan Ghat near Kali Nadi 124 Restoration and repairing of old SCADA system equipement de-shifting on shamshaan ghat TW from TW No. 20 with all required materials complete in all respect. 125 SITC of 03 Phase Servo Voltage Stabilizer 50 KVA. 126 E/M WORK OVER EXISTING TUBEWELL NO. 2 WATER WORKS CAMPUS (MAMAN CHOWKI ) 127 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 128 SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH (pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect. (suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steady state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. 129 Replacement of damaged control and power wiring of tubewell 130 Dismantling of existing pumping plant for installation of water level indicator. 131 Installation of existing pumping plant including commissioning & testing complete. 132 Restoration and repairing of old SCADA system equipement with all required materials complete in all respect. 133 SITC of 03 Phase Servo Voltage Stabilizer 50 KVA. 134 ELECTRICAL / MECHANICAL WORKFOR EXISTING OVERHEAD TANKUPARKOT 680 KL (ZONE 1A) 135 Motor operated Actuators with Sluice valve of size 250 mm. at distribution line. 136 CE & UL certified Electomagnetic Flowmeter for OHT line size 250 mm. dia. 137 Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system too including PH compensator. 138 CE/UL Certified suitable capacity UPS with batteries. 139 CE & UL certified Radar type level transmitter for OHT 140 SITC Booster pump set 200 m3/hr & differential head 10mtincluding Valve, pressure gauge, VFD, control panel, controller, power cable, pressure transmeter & dry run protection float sheets complete with required automation in all respect flow of single pump 100 m3/hr with 5.5 KW motor. (2w+1s) 141 TW Construction of 02 Nos. New & 01 No. Rebore for Zone - (1B+3A) 142 Drilling of borehole for Tubewell contruction by RC Rig Machine including transportation, erection, dismantling of Rig and assoiated T & P complete in all respect including required all material, labour etc. 143 Transportation, Erection and Dismantling of Rig Machine 144 Drilling of 600mm size bore from GL to 60 BGL 145 Drilling of 500mm size bore from 146 (i) 60M BGL to 100MBGL 147 (ii) 100M BGL to 150MBGL 148 Tubewell Assembly 149 M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support structer etc. As required & as per typed design complete in all respect. 150 300 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm. 151 200 mm. Dia MS ERW slotted/ casing pipe having wall thickness of 7.1mm. 152 Supply of pea gravel 153 Logging of bore hole by departmental / approved electric logger. 154 Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect. 155 Lowering of 300mm dia pipe from GL to 54m deep BGL. 156 Lowering of 200mm dia pipe from 54 to 100m deep BGL. 157 Lowering of 200mm dia pipe from 100 to 135m deep BGL. 158 Development of Tubewell by compressor 159 Transportation, Installation and Dismantling of 250 PSI Compressor 160 Development of Tubewell by 250 PSI Capacity Air compressor 161 Development of Tubewell by O.P. Unit 162 Transportation, Installation and Dismantling of 3 Cusec O.P. Unit & Yield Test. 163 Development of Tubewell by 3 Cusec Capacity by O.P. Unit 164 Chemical and Bacterological test of water sample from depaprtmental/ approved lab. 165 E/M WORK OVER EXISTING TUBEWELL No.-1 (MACHLI BAZAR TW No. 28) & T.W.-2 ( RADHA NAGAR TW No. 30) AT ZONE-(1B+3A) 166 Soft starter with RS-485 port-400V Class30 Kw rating or above as per site requirement. 167 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 168 Replacement of damaged control and power wiring due to shifting of all equipement. 169 Dismantling of existing pumping plant for installation of water level indicator. 170 Installation of existing pumping plant including commissioning & testing complete. 171 Restoration and repairing of old SCADA system equipement with all required materials complete in all respect. 172 SITC of 03 Phase Servo Voltage Stabilizer 50 KVA. 173 PUMPING PLANT OVER A REBORE TUBEWELL AT ZONE (1B+3A) TW-1 (MOHANKUTITW NO. 29) 174 SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1600 LPM, 30m head, 20 HPorsuitable capacity. 175 Soft starter with RS-485 port-400V Class22 Kw rating or above as per site requirement. 176 01 KVAR UPS at TW Panel 177 150 mm size motor operated actuator with Sluice valve 178 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. 179 CE/UL approved manufacturer"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. 180 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 181 CE & UL certified pressure transmitter 182 CE & UL certified Surge protector for above control panel 183 Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) 184 CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. 185 Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) 186 Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . 187 Copper cable size 2x3cx4 sq mm. flat for 18 m extra column pipe. 188 SITC of 03 Phase Servo Voltage Stabilizer 30 KVA. 189 PUMPING PLANT OVER ANEW TUBEWELL AT ZONE (1B+3A) TW-1 & 2 190 SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1600 LPM, 30m head, 20 HPorsuitable capacity. 191 Soft starter with RS-485 port-400V Class22 Kw rating or above as per site requirement. 192 01 KVAR UPS at TW Panel 193 150 mm size motor operated actuator with Sluice valve 194 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. 195 CE/UL approved manufacturer"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. 196 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 197 CE & UL certified pressure transmitter 198 CE & UL certified Surge protector for above control panel 199 CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. 200 Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) 201 Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) 202 Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . 203 Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. 204 Supply & Laying of PVC insulated Al. armoured cable size 1x3.5/4Cx35 sq mm. from transformer LV side to meter panel and meter panel to starter. 205 SITC of 03 Phase Servo Voltage Stabilizer 30 KVA. 206 ELECTRICAL / MECHANICAL WORKFOR EXISTING OVERHEAD TANK STAND ALONE AT MOHAN KUTI NEAR MAMAN CHOWKI 2200 KL ZONE (1B+3A) 207 Motor operated Actuators with Sluice valve of size 500 mm. at distribution line. 208 CE & UL certified Electomagnetic Flowmeter for OHT line size 500 mm. dia. 209 Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system too including PH compensator. 210 CE/UL Certified suitable capacity UPS with batteries. 211 CE & UL certified Radar type level transmitter for OHT 212 S.I.T.C. OF PUMPING PLANTS & ELECTRIC SUBSTATION IN PROSPECTIVE TO C.W.R. 213 PumpSet at C.W.R: 214 Pump Set :Elecrtic Driven Self Water lubricated V.T. Pumping set 3500 LPM, 36 m head with soft starter drive complete in all respect discharge head assembly and strainer with 6m column pipe length complete with 50 HP or suitable capacity VHS TEFC type induction motor SCADA compatible IP-55, 50 Hz Class-F insulation 3 phase AC supply, 415+ 6% - 10% voltsat speed 1460 RPM. MOC :Impeller : CF8MCasing : 2% Ni CI IS:210, FG: 260Shaft : AISI 410Total 03 Nos. Pumpset are proposed in module of operation in 2 Nos. are working, 1 Pump is standby. 215 Soft starter 45 KW or suitable size as per site requirement. 216 Cast iron pipes & specials. 217 Supply ofgalvanized nut- Bolt SS-304 and rubber packing material for erection of above. 218 Sluice Valve : 219 DI Sluice Valve 200 mm with actuator 220 Reflex Valve 221 DI DF double flanged single/multi door swing check valves PN 1.0 FG200 Grade having body comprising inlet & outlet sheets in gradeed cast iron diaphragm fitted woth st. steel, faces,diaphragm plate and door , sub pins and shall be of following sizes: 222 200 mm dia 223 250 mm dia 224 DI Dismantling joints 225 200 mm dia 226 250 mm dia 227 Electrical operated Travelling Trolley (E.O.T) crane compatible for longi tudinal and transverse motion both of 3 Tone capacity with 6 meter lift alongwith traveling trolley and girder etc. 228 Automatic Chlorinating Plant 229 SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steady state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. 230 CE & UL certified Electomagnetic Flowmeter at common header size 250 mm. dia. 231 L.T. Panel BoardConforming to IEC-60439 232 L.T. Panel Board suitable for operation on 400 V, 3 Phase 50 Hz. A.C. supply in sheet steel enclosure in cubical pattern floor mounting with following fitted on the phase of the panel with bus incomer bar of 400 amps. Capacity, Bus Bar size of 50*10 mm. and neutral of half the capacity and neutral of half the capacity sectionalized through a bus section. The panel shall comprise of the following. 233 02 No. incoming feeder from two Nos. Transformer with following details:- 234 02 nos. ACB of 630 amps,50 KA Micro processor type motorised drawout typefor Two seperate Transformers incomer preferably schneider/ABB with indication lamp mechanical on/off indicator. 235 One set of current transformer of ratio 400/5A 236 One No. CT operated ammeter 0-400A with ammeter 237 One No. Voltmeter 0-500 V with voltmeter 238 One No power factor meter 0.5 lag/ 1-0.5 lead 239 One No Surge arrestor Relay & One no. UV/OV Relay 240 One No frequency meter. 241 Total Nos. of Outgoing feeder as follows- 242 MCCB of 200 amps,50KA capacity with indication lamp mechanical on/off indicator. -03 nos. 243 Ammeter with selector switch. 244 Single phasing preventer. 245 Sets of timer and relays for overload and underload. 246 01 Nos. 63 Amps. MCCB for RTU/PLC Panel. 247 01 Nos. 63 Amps. MCCB as Misc. load 248 02 Nos. 32 Amps. 4P MCCB for lighting & spare one. 249 01 No. required 30 KVAr APFC Panel with capacitor bank and feeder SFU & MCCB 63 Amp., 25 KA with APFCrelay in 9 steps & other acceessories to adjust automatically the power factor upto 0.99. 250 Power and control cables 251 1100 V grade, 3 core 50mm2 PVC insulated PVC sheathed Aluminium Armoured conductor cablefrom LT panel to motor.(1x3x40 mtr.) 252 Control cable 1x10C, 1.5 mm2 PVC insulated PVC sheathedCopper conductor cable for moisture sensor Reverse protection thermistor relay etc. 253 EARTHING 254 Complete earthing of all the equipments as detailed above shall be done as per IS/IER/PWD specification with G.I Plates, watering pipe and loop earthing with adequate size of G.I/ Al. strip etc. (PS-702) 02 Nos. each of the equipment(3 Nos Pumps + 1 No. LT Panel + 1 No. PLC Panel.) size of earthing plate 600mm x 600mm x6 mmwith salt and coal. 255 Lighting system: 256 Supply & erection of M.S. Tubular Poles SP-36, 9.5 M height. 257 S/F of 72 watt LED with lumen reflector. 258 Feeder pillar for lighting 259 Supply and laying of 4x16mm2 Al. armoured cable. 260 Internal electrification with fixtures. 261 S/F 1200 mm ceilingFan for LT Room 262 S/F of exhaust Fan for LT Room, VCB room. 263 Earthing of street light pole (SOR-41) 264 Painting of street light (P5-634) 265 Supply and installation of DCP type of 5 Kg. Fire existinguisher(PS-1132) 266 12 mm thick rubber mating for safe working on. 267 Tools 268 Hydrulic crimping tools-Crimping range: 16-300 sq.mm.,Weight: 6 Kg. ,Length: 500mm,Make/ Model:YQK300 269 Mannual crimping tools-Crimping range: 400 sq.mm.,Make/ Model: Crimp well 270 Tong tester (AC/DC-1000A, make-Rishabh)Multimeter (AC/DC-1000A,make-Meco)Megger (AC/DC-500V make-Rishabh)Screwdriver (6"x 12", make- Taparia)Plier (250mm, make-Taparia) 271 Chain wrench (12"x18", make Taparia) Pipe wrench (1200mm, make Taparia) 272 Installation of above equipments ,Pumsets and Panels etc. complete. 273 Testing of pumping plantand Panels etc. complete at works 274 Commissioning of pumping plantsand Panels etc. complete 275 Chequered plate of required size so as to cover all trenches. 276 Power Distribution Transformer : 277 Supply of Oil immersedOutdoor type Power distribution transformer 11/0.433 KV rating 200 KVA double wound with copperwinding, Level-1, vector group dyn 11, ONAN with manually operated ± 5.0 % off load tap changer in step of 2.5% and complete with standard fitting & accessories. 278 Supply and laying of 1100 voltage grade ,1Rx3.5Cx 185 mm2 Aluminium conductor, XLPE armoured cable from Transformers to LT Panel. 279 Double Earthing of Transformers consisting of 04 nos. Earthing Pit (two for each neutral and body) with Al/GI. strip size 25X6mm, the minimum distance between to earthing pits, Double Earthing works and all electrical equipments shall be as per IS and IER. 280 Installation , testing and Commissioning of Transformer complete. 281 H.T. Switch Gear Panel : 282 Supply of 12 KV,H.T. V.C.B. Panel with one incoming & two out going ,630 Amp. (25 KA) Rating have followings- 283 Incommer Feeder- 01 No. 284 3 O/C + 1 EF IDMT Characteristics Relays based Incommer control panel equiped with over current & earth fault relay with core balance C.T., master trip relay, instantaneous under voltage realy & Auxilliary realy etc.C.T.ratio 30-20/5A Dual core, Class-1 for measurement core & 5P10 for protection core & PT 11KV/110 VAC. KWH meter, power factor meter, frequency meter. Amp. meter 0-20& volt meter 0 to12 KV. All relays required separately conventioal type 24 to 30 VDC, 110 VAC. 285 Outgoing Feeder- 02 Nos. 286 outgoing feeder control panel equiped withtriple pole 2 O/C + 1 E/F relay with IDMT & intantaneous characterisstics, mater trip relay & Auxilliary relay for Buchhloz alarm / trip, OTI alram / trip & WTI alram/trip, etc.C.T.ratio 30-15/5A, Class-1 for measurement core & 5P10 for protection core. 287 DC Supply 288 SICT battery bank, exide make, consisting of 16 cells, 2 volt each for supply VDC 24 to 30 Volt with battery charger of approved make with suitable M.S. Stand / Trolley, equipment fittings with accessories etc. 289 Supply and laying of 1x3Cx95 mm 2 ,11 KV HT Al. XLPE cable from metering panel to H.T. Panel and form H.T. Panel to both transformers. 290 S/F of XLPE cable End termination box 291 Indoor end termination box. 292 Earthing ofH.T Panel as per IS & IER. 293 Testing & Commissioning of HT Panel etc. 294 Erection of All sub staion equipments and fencing with iron mesh etc. complete in all respect. 295 Commissioning of All sub station equipments etc. complete in all respect. 296 OTHER REQUIRED ITEMS 297 CE/UL approved manufacturer"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. 298 Auto phase reversal unit -Auto phase reversal unit/ automatic transfer switch withinbuilt time delay & enclosure of SuitableAmpere rating (Confirming to IEC: 60947-1 and IEC: 60947-b-1)as specified in tender technical specification sheet.250amp 299 CE / UL approved manufacturer’s Radartype Level Transmitter for CWR as specified in tender technical specification sheet 300 CE / UL approved manufacturer’s Pressure Transmitterin main header line of Pump as per specifications specified in tender technical specification sheet. 301 CE & UL certified Surge protector for control panel 302 CE & UL certified pressure transmitter for each pump 303 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each ZPS/ OHTto store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. 304 G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. 305 CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. 306 Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) 307 Complete cabling for ZPS including all power and control cable of all equipments at ZPS 308 Security Surveillance IP Camera with Recorer 309 Installation, commissioning & testing for CWR 310 S.I.T.C OF SCADA SYSTEM ONTUBEWELL AT ZONE (1B+3A) 311 REBORE TUBEWELL No. - 1 (MOHANKUTITW NO. 29) ZONE (1B+3A) 312 Dismantling of existing pumping plant for installation of SCADA equipements. 313 Shifting of all SCADA instruments from Mohan Kuti TW to New Rebore TW 314 Restoration and repairing of old SCADA system equipement de-shifting on new rebore TW with all required materials complete in all respect. 315 Installation, commissioning & testing for one tubewell 316 Trial run for three month period for tubewell 317 NEW T.W.- 1 (CWR CAMPUS) & TW -2 (Not define) ZONE (1B+3A) 318 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. 319 G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. 320 Installation, commissioning & testing for one tubewell 321 Trial run for three month period for tubewell 322 COST OF INTEGRATION 323 Cost of integration of Tubewells, OHT & CWR with MCS/ LCS 324 S.I.T.C OF SCADA SYSTEM FOR EXISTING STAND ALONE OVERHEAD TANKUPARKOT 680 KL (ZONE 1A) 325 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations 326 G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges . 327 S.I.T.C OF SCADA SYSTEM FOR EXISTING OVERHEAD TANK STAND ALONE AT MOHAN KUTI NEAR MAMAN CHOWKI 2200 KL ZONE (1B+3A) 328 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations 329 G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges . 330 03 MONTH TRIAL & RUN OF PUMPING PLANT OF TUBEWELL FOR ZONE 1A 331 03 Month trial & run of Pumping Plant for 02 Nos. existing tubewell & 01 no. booster pump including liquid Chlorine, Operating Staff. Excluding Electricity Charges. 332 03 MONTH TRIAL & RUN OF PUMPING PLANT OF TUBEWELL FOR ZONE (1B+3A) 333 03 Month trial & run of Pumping Plant for 01 No. new tubewell, 01 no rebore tubewell & 02 nos existing tubewell including Operating Staff. Excluding Electricity Charges. 334 03 MONTH TRIAL & RUN OF PUMPING PLANT OF CLEAR WATER RESERVIOR. 335 03 Month trial & run of Pumping Plant for 01 No. new tubewell & CWR including liquid Chlorine, Operating Staff. Excluding Electricity Charges. 336 PART-B (Nagar Palika Parishad water supply Reorganization scheme Zone-02) 337 Civil Work 338 Construction ofRCC Overhead Tank of 2300 KL Capacity at 24 m Staging from made up level (Made Up Level of OHT will be taken as 0.70 m above from newrby existing approach road level) in M-30 grade of concrete.(Zone-2B) 339 Submission of design, drawing and supply of all material, labour T&P etc. and construction as per tenderer"s own provided seismic proof design and drawings (approved by the department) complete Intze type tank, on raft or pile cum raft foundation with columns and braces R.C.C. Over Head Tank 2300 KL capacity at 24 m staging from made up level of OHT at site to the top of bottom ring beam of tank. Made up level of OHT will be taken as 0.70 m above from nearby existing approach road level.Earth required for made up level & Brick work required for apron will be arranged by the contractor at his own cost. No extra payment will be paid for this work. The design of the tank shall be based on safe bearing capacity of soil at site as 7 T/m2 and depth of foundation as 3.0 m from existing ground level on pile/raft foundation. If the bearing capacity of soil is found less than 8 T/m2 as per test report, the contractor will submit the design on the B.C. proposed by the NABL approved reputed testing agency. No extra payment will be made for this change. If the B.C. is found more than 8 T/m2 as per testing report than the design of OHT shall be done at B.C 8 T/m2 and depth 2.50m or the depth suggested by testing agency (greater of the two depths). All other details of tank not covered here shall also be as per specifications enclosed. ITEM 340 & 341 ARE SOME DETAILS (NOT LIMITED TO) OF WORK WHICH ARE TO BE DONE DURING CONSTRUCTION OF OHT AND THEIR COST IS INCLUDED IN ITEM 339 (NO EXTRA PAYMENT WILL BE CLAIMED/MADE). 340 Soil testing Submission of detailed design and drawing including its vetting shall be done from any recognized Government University such as I.I.T./NIT/State Govt./ Centre Govt.institutions / organizations or as per direction of Engineer-in-charge.R.C.C. work will be strictly as per approved design including fixing various pipes and S.S ventilator at the top and fixing of S.S. sheet of 10 mm gauge manhole cover of 60 cm x 60 cm size with frame and locking arrangement and railing including supply of all material complete in all respect. Water bar"s / water stoppers of 18mm gauge and 30 cm wide (15cm below the joint and 15cm above the joint) along the joint of cylindrical wall of over head tank at every lift / joint should be provided.Supply and fixing of S.S. ladder, inside the tank body from roof to the bottom dome of the tank in a slope of 3: 1 (3 vertical: 1 horizontal) with railing as specified.Railing on double column staircase & its landings, all around balcony & top dome for access up to ventilator as per specifications including supply of all material. Railing shall be provided in three rows of G.I. pipe (medium) 20mm dia. (min.). Box type enclosure at the entrance of the staircase upto first landing having locking arrangement should be provided.Supply and fixing of digital water level indicator along with all necessary equipments such as inverter etc. as per specifications and fixing of lightening arrestor, conductor and earth plate etc. as per specifications. 341 Supply of all materials and construction of 100 mm thick R.C.C. floor apron and 15 cm dia. semi circular drain around apron in a slope towards wash out chamber with glass strips, with base concrete 1:3:6 with stone ballast of thickness 150mm.Three coats of approved quality and shade of Apex ultima Paintas per direction of Engineer-in-charge over concrete work including supply of all materials etc. Three coats of anti corrosive / aluminum / black Japan paint of approved quality on all iron work including supply of all material, labour and T&P etc complete in all respect.Supplying and fixing of all required sizes C.I. D/F sluice valves kirloskar make , RCC overflow chamber & Sluice Valve Chamber as per relevant latest I.S. specifications at below ground level or as per direction of E/I including supply of all jointing and other make materials such as rubber insertion sheet, nut bolts, washer etc, complete as per Specifications.Supply and fixing of following pipes:-Inlet pipe-500 mm dia;DMA -1 Outlet pipe-300mm diaDMA -2 Outlet pipe-300mm diaDMA -3 Outlet pipe-300mm diaDMA -4 Outlet pipe-450mm Over flow pipe -400 mm dia Wash out pipe-100 mm dia .The words U.P. Jal Nigam (Urban), year of construction, capacity of O.H.T. with staging and slogan approved by Engineer in charge shall be painted prominently in Block Letters not less than 30 cm in height. Testing of tank for water tightness as per specifications enclosed/ as per CPHEEO Manual including supply of water. Trial & Run of 3 months, maintenance of work ( till handing over or date of shedule complision whichever is later) and defect liability period of 12 months after handing over to NagarPalika Parishad Bulandshahr. including supply of all materials, labour, T&P etc. complete in all respect. 342 Construction ofRCC Overhead Tank of 2200 KL Capacity at 24 m Staging from made up level (Made Up Level of OHT will be taken as 0.70 m above from nearby existing approach road level) in M-30 grade of concrete. (Zone-2C) 343 Submission of design, drawing and supply of all material, labour T&P etc. and construction as per tenderer"s own provided seismic proof design and drawings (approved by the department) complete Intze type tank, on raft or pile cum raft foundation with columns and braces R.C.C. Over Head Tank 2200 KL capacity at 24 m staging from made up level of OHT at site to the top of bottom ring beam of tank. Made up level of OHT will be taken as 0.70 m above from nearby existing approach road level.Earth required for made up level & Brick work required for apron will be arranged by the contractor at his own cost. No extra payment will be paid for this work. The design of the tank shall be based on safe bearing capacity of soil at site as7 T/m2and depth of foundation as 3.0 m from existing ground level on pile/raft foundation. If the bearing capacity of soil is found less than 7 T/m2 as per test report, the contractor will submit the design on the B.C. proposed by the NABL approved reputed testing agency. No extra payment will be made for this change. If the B.C. is found more than 7 T/m2 as per testing report than the design of OHT shall be done at B.C 8 T/m2 and depth 3.0m or the depth suggested by testing agency (greater of the two depths). All other details of tank not covered here shall also be as per specifications enclosed. ITEM 344 & 345 ARE SOME DETAILS (NOT LIMITED TO) OF WORK WHICH ARE TO BE DONE DURING CONSTRUCTION OF OHT AND THEIR COST IS INCLUDED IN ITEM 343. (NO EXTRA PAYMENT WILL BE CLAIMED/MADE). 344 Soil testing Submission of detailed design and drawing including its vetting shall be done from any recognized Government University such as I.I.T./NIT/State Govt./ Centre Govt.institutions / organizations or as per direction of Engineer-in-charge.R.C.C. work will be strictly as per approved design including fixing various pipes and S.S ventilator at the top and fixing of S.S. sheet of 10 mm gauge manhole cover of 60 cm x 60 cm size with frame and locking arrangement and railing including supply of all material complete in all respect. Water bar"s / water stoppers of 18mm gauge and 30 cm wide (15cm below the joint and 15cm above the joint) along the joint of cylindrical wall of over head tank at every lift / joint should be provided.Supply and fixing of S.S. ladder, inside the tank body from roof to the bottom dome of the tank in a slope of 3: 1 (3 vertical: 1 horizontal) with railing as specified.Railing on double column staircase & its landings, all around balcony & top dome for access up to ventilator as per specifications including supply of all material. Railing shall be provided in three rows of G.I. pipe (medium) 20mm dia. (min.). Box type enclosure at the entrance of the staircase upto first landing having locking arrangement should be provided.Supply and fixing of digital water level indicator along with all necessary equipments such as inverter etc. as per specifications and fixing of lightening arrestor, conductor and earth plate etc. as per specifications. 345 Supply of all materials and construction of 100 mm thick R.C.C. floor apron and 15 cm dia. semi circular drain around apron in a slope towards wash out chamber with glass strips, with base concrete 1:3:6 with stone ballast of thickness 150mm.Three coats of approved quality and shade of Apex ultima Paintas per direction of Engineer-in-charge over concrete work including supply of all materials etc. Three coats of anti corrosive / aluminum / black Japan paint of approved quality on all iron work including supply of all material, labour and T&P etc complete in all respect.Supplying and fixing of all required sizes C.I. D/F sluice valves kirloskar make , RCC overflow chamber & Sluice Valve Chamber as per relevant latest I.S. specifications at below ground level or as per direction of E/I including supply of all jointing and other make materials such as rubber insertion sheet, nut bolts, washer etc, complete as per Specifications.Supply and fixing of following pipes:-Inlet pipe-400 mm dia;DMA -1 Outlet pipe-300mm diaDMA -2 Outlet pipe-350mm diaOver flow pipe -400 mm dia Wash out pipe-100 mm dia .t.The words U.P. Jal Nigam (Urban), year of construction, capacity of O.H.T. with staging and slogan approved by Engineer in charge shall be painted prominently in Block Letters not less than 30 cm in height. Testing of tank for water tightness as per specifications enclosed/ as per CPHEEO Manual including supply of water. Trial & Run of 3 months, maintenance of work (till handing over and defect liability period of 12 months after handing over or date of shedule complision whichever is later) to NagarPalika Parishad Bulandshahr. including supply of all materials, labour, T&P etc. complete in all respect. 346 Supply of all materials labour T&P etc. complete and construction of R.C.C. (M30 Grade) CWR of 800 KL capacity awith main components, excluding cost of soil testing. 347 All the components of C.W.R will be casted in M30 concrete with cement, coarse sand and approved stone grit as per I.S. 11682 and I.S.456 348 Minimum depth of foundation below original ground level will be 4.5M 349 Seismic effects and wind load should be taken into consideration as I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure (this area is in seismic Zone IV and high damage risk zone for wind) 350 The above cast of C.W.R has been assumed that ,the bearing capacity of soil has been taken as 8 M.T.sqm. 351 Proper ventilator at top dome in circular shape of 8 m dia. along with an R.C.C. cover of minimum 1.50m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia.The space between top dome and R.C.C. cover should be covered with mosquito net of standard quality along with expanded metaled jali. 352 Water level indicator fabricated with good quality minimum 45mm x 45mm x 6mm M.S.angle and 3mm thick 6mm flat M.S.sheet. The indicator board scale made of 3mm thick M.S. plate should have a clear width of minimum 25cm painted with good Asian paint. It should also consists of 3mm brass wire rope minimum 4 smooth pulleys about 8 cm dia with guides,15cm dia copper ball float which shall be completely water tight suitable pointer of brass etc. 353 Lightening conductor as per I.S.S.2309 of its latest amendments of latest electricity rules. It should consist proper elevation rod with 5 or more fork points proper down conductors of prescribed metal of proper size prescribed by ISS 2309-1969 and ISS 3013-1966 354 C.I. manhole of min 60x60cm size made of M.S.channel section with adequate cover made of M.S. sheet of minimum 3mm thickness hinged with manhole with locking aarrangement.This manhole should be fixe at top dome at proper place. 355 Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit under each duck foot bend to support the vertical pipes. These bed blocks should supported on the raft not on the soil . 356 Painting of all concrete surface and steel pipe works with three coats of approved cement paint and anticorrosive paints. 357 Construction of pump house, chlorinating room,MCS room, Boundary Wall with gate and approach road works 358 Supply of all materials and construction of pump house of size (3.6 m x 3.0 m x 3.0 m) cum chlorinating room size (1.80mx 2.60 m x 3.00 m) . (As per type design of UPJN (Urban). 359 Construction of Stilling chamber (1.50 m x 1.50 m x 1.00 m) and V Noch for bye-pass Arrangement of Tubewells complete in all respect as per direction of Engineer in Charge. 360 Construction of MCS at NPP Bulandshahr centralized control room including supply of all materials, labour, T&P etc. complete in all respect as per direction of Engineer in Charge. 361 Construction of boundary wall around water works compound.(As per type design of UPJN (Urban)). 362 Supply and fixing 3.6M & 1.20M wide MS Gate with pillers including fabrication and supply of steel and construction of boundary pillars etc. complete for pump house complete in all respect as per direction of Engineer in Charge. 363 Supply & laying of 80mm cement interlocking tiles for approach road including 100 mm thick P.C.C. 1:6:12supply of all materials, labour, T&P etc. complete in all respect as per direction of Engineer in Charge. 364 Recharge unit (RWH) of ground water by rooftop rainwater of pump house and water available of byepass arrangement of tubewell and washout as per drawing including supply of all material T&P to the satisfaction of E-In-C 365 Laying of Rising Main pipe line & appurtenent works 366 Excavation of earth in ordinary soil (loam, clay or sand) for laying of pipe line including refilling, ramming, dressing, leveling of trenches in 30 cm layers anddisposal of surplus earth for different size of pipe lift up to 1.5m and 500 m awayas per direction of Engineer in Charge . If any Utilities are damaged during excavation (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work 367 Supply of D.I. pipe line into trenches true to alignment & agradient including Supply of D.I. D/F specials, F.O.R. destination and all taxes and insurance etc. cost of all labour, T&P, jointing, materials,specials, testing of pipe line etc. complete 368 D.I. pipe Class-K-9 369 200 mm dia 370 450 mm dia 371 Carting laying & jointing of D.I. pipe line into trenches true to alignment & agradient including cost of all labour, T&P, jointing, materials,specials, testing of pipe line etc. complete.If any Utilities are damaged during carting or laying or jointing (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work 372 D.I. pipe Class-K-9 373 200 mm dia 374 450 mm dia 375 Supply of following size and carting upto site of work, lowering, fixing and jointing of followingfittings in trenches including cost of all materials such as rubber packing, nut bolts etc. complete work 376 C.I.D/F Sluice Valve IS 780-1984 377 200 mm dia 378 450 mm dia 379 THRUST BLOCK 380 Provision forR.C.C. Thrust Block with cement, coarse sand & 20 mm gauge stone ballast in proportion of 1:1.5:3 in pipe line including supply of reinforcement and its fixing and binding the same with 0.50 mm thick binding wire on position and necessary centering & shuttering complete for proper completion of work including supply of steel and wastage etc. 381 Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. 382 B.O.E. Road 383 Bituminous Road 384 Interlocking Road 385 Cement Concrete Road 386 Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. 387 B.O.E Road (Using 60% old & 40% New) 388 Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) 389 Interlocking Road (Using 60% old tiles including spreading of local sand and base concrete in 1:6:12 ,10 cm thickness) 390 Cement Concrete Road (100mm thickness of1:2:4 cement concrete over base of 100mm thickness of 1:4:8 Lean concrete) 391 Sluice Valve Chamber (Masonary Type) 392 Provision for crossings of nalas & culvert including sifting of telephone cables etc. Along the alignment of pipeline including supply of C.I. tyton pipe andspecials etc. complete. (3.0 M.Wide Road) 393 Laying of Distribution pipe line & other appurtenent works 394 Excavation of earth in ordinary soil (loam, clay or sand) for laying of pipe line including refilling, ramming, dressing, leveling of trenches in 30 cm layers anddisposal of surplus earth for different size of pipe lift up to 1.5m and 500 m awayas per direction of Engineer in Charge . If any Utilities are damaged during excavation (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work 395 Supply of following size of pipes including all types of specials, railways frieght and cartage up to store , all taxes and duties complete as per direction of Engineer-in-charge. 396 HDPE Pipe (PE-100) 397 110 mm dia 398 140 mm dia 399 160 mm dia 400 DI Pipe Class K-7 401 200 mm dia 402 250 mm dia 403 300 mm dia 404 350 mm dia 405 400 mm dia 406 450 mm dia 407 500 mm dia 408 Carting ,laying and jointing of the following sizes of pipes into the trenches includingall types of specials, cost of all jointing materials,making interconnection & specials, labour and T & P , testing etc. completeas per direction of Engineer-in-charge.If any Utilities are damaged during carting or laying or jointing (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work. 409 HDPE Pipe (PE-100) 410 110 mm dia 411 140 mm dia 412 160 mm dia 413 DI Pipe Class K-7 414 200 mm dia 415 250 mm dia 416 300 mm dia 417 350 mm dia 418 400 mm dia 419 450 mm dia 420 500 mm dia 421 Supply and fixing & carting of following types of fittings including railway frieght, cartage up to site, all taxes and duties etc. complete. 422 (A) C. I. Sluice Valveas per latest IS specifications 423 100 mm dia 424 125 mm dia 425 150 mm dia 426 200 mm dia 427 250 mm dia 428 Scour Valve 80 mm dia 429 CI Single ball type Air Valve 20 mm dia 430 Fire Hydrants 80 mm dia 431 Supply of all materials, labour, T&P for construction of following types of chambers as per departmental drawing & design. 432 Sluice Valve Chamber (Masonary Type) 433 Sluice Valve Chamber (Surface Box Type) 434 Fire Hydrant Chambers 435 Air Valve Chambers 436 Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. 437 B.O.E. 438 C.C. Interlocking Tiles Road 439 C.C. Road 440 Bituminous Road 441 Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. 442 B.O.E Road (60% old and 40% new Bricks) 443 Laying of 80mm thick C.C. Interlocking Tiles Road with 40% new Tiles including dressing surface and including supply of tile,including all labour T&P etc. required for proper completion of work. 444 CC Road (100mm thickness of1:2:4 cement concrete ) over P.C.C. 1:4:8 in cement course sand and 40 mm th. Stone ballast including filling of jointing with local sand spreading and blinding coat of 10 mm to 25 mm deep of local sand over the entire surface and including all labour T&P etc. required for proper completion of work. 445 Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) 446 Provision for crossings of nalas & culvert including shifting of telephone cables etc. along the alignment of pipeline including supply of C.I. tyton pipe andspecials etc. complete in all respect as per direction of Engineer in Charge. 447 For up to 1.5 M wide 448 For up to 1.5 M to 3.0 M wide 449 For above 3.0 M wide 450 Making New Water House Connection with Distribution main excluding Dismantling & permanent reinstatement in all types of road but including supply , carting of specials lowering them into trenches, fixing them including bailing out of water necessary excavation for connection including all labour , T&P etc. required for proper completion of the works as per direction of engineer - in- Charge. 451 For 90 mm to 500mm dia (HDPE Pipe/ DI ) 452 Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. 453 B.O.E. 454 C.C. Interlocking Tiles Road 455 C.C. Road 456 Bituminous Road 457 Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. 458 B.O.E Road (60% old and 40% new Bricks) 459 Laying of 80mm thick C.C. Interlocking Tiles Road with 40% new Tiles including dressing surface and including supply of tile,including all labour T&P etc. required for proper completion of work. 460 CC Road (100mm thickness of1:2:4 cement concrete ) over P.C.C. 1:4:8 in cement course sand and 40 mm th. Stone ballast including filling of jointing with local sand spreading and blinding coat of 10 mm to 25 mm deep of local sand over the entire surface and including all labour T&P etc. required for proper completion of work. 461 Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) 462 Maintenance works 463 Repairing of OHT 2000KL/22 M staging due to seepage in bottom dome, conewall & vertical wall after chiseling the loose concerete and ensuring water tightness of the OHT & repairing of 200 mm to 500 dia sluice valveincluding Scrapping and chiseling of plaster, providing and applying one coat of slurry of hydrophilic in nature for waterproofing treatment from the internal surface of Over Head Tank, required thickness plaster with chemical coding, supply and fixing of scaffolding, painting, colour washing, with Asian Apex Paint, stacking/proper disposal of dismantled plaster material, repairing of staircase including supply and fixing of GI pipe hand rail, vertical post and also repairing of minor defect in landing, riser and tread, Supply & fixing of Proper ventilator at top dome in circular shape along with an R.C.C. cover of minimum 1.50m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia., Lightening conductor as per I.S.S.2309 of its latest amendments of latest electricity rules, C.I. manhole of min 60x60cm size made of M.S.channel & Painting of all concrete surface and steel pipe works with all labour, material T&P complete in all respect as per direction of Engineer in Charge. 464 Repairs of Existing Pumphouse cum clorenating room Including Supply all materials, labour, T&P etc. Required for proper completion of work complete in all respect as per direction of Engineer in Charge. 465 Repairs of boundary wall Supply all materials, labour, T&P etc. Required for proper completion of work complete in all respect as per direction of Engineer in Charge. 466 Interconnection in existiing distribution main with supply all material ,specials labour dismantling and reinstatementof all types of road etc complete 467 E & M work 468 ZONE - 2A 469 PUMPING PLANT OVER A EXISTING TUBEWELL AT ZONE-2A, T.W.-1 ( AVAS VIKAS FIRST TW 31), & T.W.-2 ( AVAS VIKAS FIRST TW 32), 470 SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1500 LPM, 55m head, 30 HP 471 Soft starter with RS-485 port-400V Class22 Kw rating or above as per site requirement. 472 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 473 SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. 474 Replacement of damaged control and power wiring at tubewell of all equipement at pump house & OHT 475 SITC of 03 Phase Servo Voltage Stabilizer 50 KVA. 476 Dismantling of existing pumping plant 477 Installation of above pumping plant including commissioning & testing complete. 478 Repairing and overholing of actuator including all labour etc. complete. 479 PUMPING PLANT OVER A EXISTNG TUBEWELL AT ZONE 2A, T.W.-3 (AVAS VIKAS OLD OHT CAMPUS REBORE TW NEWLY CONSTRUCTED BY NAGAR PALIKA PARISHAD FROMC&DS UNIT (2023)TW No. 11), 480 SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 2000 LPM, 55m head, 40 HP 481 Soft starter with RS-485 port-400V Class30 Kw rating or above as per site requirement. 482 01 KVAR UPS at TW Panel 483 150 mm size motor operated actuator with Sluice valve 484 CE/UL approved manufacturer"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. 485 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 486 CE & UL certified pressure transmitter 487 Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) 488 CE & UL certified Surge protector for above control panel 489 Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . 490 SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. 491 SITC of 03 Phase Servo Voltage Stabilizer 50 KVA. 492 Dismantling of existing pumping plant 493 Installation of above pumping plant including commissioning & testing complete. 494 ELECTRICAL / MECHANICAL WORKFOR EXISTING OVERHEAD TANKAWAS VIKAS 1st 2200 KL (ZONE 2A) 495 Repairing of Motor operated Actuators with Sluice valve of size 350 mm. at distribution line. 496 Repairing of CE & UL certified Electomagnetic Flowmeter for OHT line size 350 mm. dia. 497 Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system too including PH compensator. 498 CE/UL Certified suitable capacity UPS with batteries. 499 Zone-2B 500 New Tubewell of size 300x200 mm. dia by D.C./RC Rig Machine 501 Drilling of borehole for Tubewell contruction by RC Rig Machine including transportation, erection, dismantling of Rig and assoiated T & P complete in all respect including required all material, labour etc. 502 Transportation, Erection and Dismantling of Rig Machine 503 Drilling of 600mm size bore from GL to 60 BGL 504 Drilling of 500mm size bore from 505 60M BGL to 100MBGL 506 100M BGL to 150MBGL 507 Tubewell Assembly 508 M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support structer etc. As required & as per typed design complete in all respect. 509 300 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm. 510 200 mm. Dia MS ERW slotted/ casing pipe having wall thickness of 7.1mm. 511 Supply of pea gravel 512 Logging of bore hole by departmental / approved electric logger. 513 Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect. 514 Lowering of 300mm dia pipe from GL to 54m deep BGL. 515 Lowering of 200mm dia pipe from 54 to 100m deep BGL. 516 Lowering of 200mm dia pipe from 100 to 135m deep BGL. 517 Development of Tubewell by compressor 518 Transportation, Installation and Dismantling of 250 PSI Compressor 519 Development of Tubewell by 250 PSI Capacity Air compressor 520 Development of Tubewell by O.P. Unit 521 Transportation, Installation and Dismantling of 2 Cusec O.P. Unit & Yield Test. 522 Development of Tubewell by 2 Cusec Capacity by O.P. Unit 523 Chemical and Bacterological test of water sample from depaprtmental/ approved lab. 524 PUMPING PLANT OVER A EXISTING TUBEWELL AT ZONE-2B, TW No.-1(HARISHCHANDER NAGAR TW No. 10) & T.W.-2 ( BABUPURA TW No. 14) 525 SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1300 LPM, 30m head, 15 HP 526 Soft starter with RS-485 port-400V Class15 Kw rating 527 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 528 Replacement of damaged control and power wiring at tubewell of all equipement at pump house & OHT 529 SITC of 03 Phase Servo Voltage Stabilizer 25 KVA. 530 Dismantling of existing pumping plant 531 Installation of above pumping plant including commissioning & testing complete. 532 Repairing and overholing of actuator including all labour etc. complete. 533 PUMPING PLANT OVER A EXISTING TUBEWELL AT ZONE-2B, TW No.3 (REBORE TW NEWLY CONSTRUCTED BY NAGAR PALIKA PARISHAD FROMC&DS UNIT (2023)TW DEVIPURA BANDH) 534 SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1300 LPM, 30m head, 15 HP 535 Soft starter with RS-485 port-400V Class15 Kw rating 536 01 KVAR UPS at TW Panel 537 150 mm size motor operated actuator with Sluice valve 538 Capacitor Bank 10 KVAR with Relay 539 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. 540 CE/UL approved manufacturer"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. 541 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 542 CE & UL certified pressure transmitter 543 CE & UL certified Surge protector for above control panel 544 Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) 545 Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . 546 Copper cable size 2x3cx4 sq mm. flat for 18 m extra column pipe. 547 SITC of 03 Phase Servo Voltage Stabilizer 20 KVA. 548 PUMPING PLANT OVER A NEW TUBEWELL AT ZONE 2B, T.W.- 1 (CWR CAMPUS) & TW -2 (Not define) 549 SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accessories with nut bolt ,rubber packing etc 2000 LPM, 30m head, 25 HP 550 Soft starter with RS-485 port-400V Class30 Kw rating or above as per site requirement. 551 01 KVAR UPS at TW Panel 552 150 mm size motor operated actuator with Sluice valve 553 Capacitor Bank 10 KVAR with Relay 554 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. 555 CE/UL approved manufacturer"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. 556 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 557 CE & UL certified pressure transmitter 558 CE & UL certified Surge protector for above control panel 559 Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) 560 Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . 561 Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. 562 Supply & Laying of PVC insulated Al. armoured cable size 1x3.5/4Cx35 sq mm. from transformer LV side to meter panel and meter panel to starter. 563 SITC of 03 Phase Servo Voltage Stabilizer 40 KVA. 564 ELECTRICAL / MECHANICAL WORKFOR NEW OVERHEAD TANK AT LADIES THANA 2200 KL (ZONE 2B) 565 Motor operated Actuators with Sluice valve of size 500 mm. at distribution line. 566 CE & UL certified Electomagnetic Flowmeter for OHT line size 500 mm. dia. 567 Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system too including PH compensator. 568 CE/UL Certified suitable capacity UPS with batteries. 569 S.I.T.C. OF PUMPING PLANTS & ELECTRIC SUBSTATION IN PROSPECTIVE TO C.W.R. 570 Pump Set at C.W.R: 571 Pump Set :Elecrtic Driven Self Water lubricated V.T. Pumping set 4000 LPM, 38 m head with soft starter drive complete in all respect discharge head assembly and strainer with 6m column pipe length complete with 60 HP or suitable capacity VHS TEFC type induction motor SCADA compatible IP-55, 50 Hz Class-F insulation 3 phase AC supply, 415+ 6% - 10% voltsat speed 1460 RPM. MOC :Impeller : CF8MCasing : 2% Ni CI IS:210, FG: 260Shaft : AISI 410Total 03 Nos. Pumpset are proposed in module of operation in 2 Nos. are working, 1 Pump is standby. 572 Soft starter with RS-485 port-400V Class55 KW rating or above as per site requirement. 573 Cast iron pipes & specials. 574 Supply ofgalvanized nut- Bolt SS-304 and rubber packing material for erection of above. 575 Sluice Valve : 576 Sluice Valve 200 mm with actuator 577 Reflex Valve 578 CIDF double flanged single/multi door swing check valves PN 1.0 FG200 Grade having body comprising inlet & outlet sheets in gradeed cast iron diaphragm fitted woth st. steel, faces,diaphragm plate and door , sub pins and shall be of following sizes: 579 200 mm dia 580 300 mm dia 581 CI Dismantling joints 582 200 mm dia 583 300 mm dia 584 Electrical operated Travelling Trolley (E.O.T) crane compatible for longi tudinal and transverse motion both of 3 Tone capacity with 6 meter lift alongwith traveling trolley and girder etc. 585 Automatic Chlorinating Plant 586 SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. 587 CE & UL certified Electomagnetic Flowmeter at common header size 300 mm. dia. 588 CE / UL approved Pressure Transmitter for each pump. 589 L.T. Panel BoardConforming to IEC-60439 590 L.T. Panel Board suitable for operation on 400 V, 3 Phase 50 Hz. A.C. supply in sheet steel enclosure in cubical pattern floor mounting with following fitted on the phase of the panel with bus incomer bar of 400 amps. Capacity, Bus Bar size of 50*10 mm. and neutral of half the capacity and neutral of half the capacity sectionalized through a bus section. The panel shall comprise of the following. 591 02 No. incoming feeder from two Nos. Transformer with following details:- 592 02 nos. ACB of 630 amps,50 KA Micro processor type motorised drawout typefor Two seperate Transformers incomer preferably schneider/ABB with indication lamp mechanical on/off indicator. 593 One set of current transformer of ratio 400/5A 594 One No. CT operated ammeter 0-400A with ammeter 595 One No. Voltmeter 0-500 V with voltmeter 596 One No power factor meter 0.5 lag/ 1-0.5 lead 597 One No Surge arrestor Relay & One no. UV/OV Relay 598 One No frequency meter. 599 Total Nos. of Outgoing feeder as follows- 600 MCCB of 200 amps,50KA capacity with indication lamp mechanical on/off indicator. -03 nos. 601 Ammeter with selector switch. 602 Single phasing preventer. 603 Sets of timer and relays for overload and underload. 604 01 Nos. 63 Amps. MCCB for RTU/PLC Panel. 605 01 Nos. 63 Amps. MCCB as Misc. load 606 02 Nos. 32 Amps. 4P MCCB for lighting & spare one. 607 01 No. required 40 KVAr APFC Panel with capacitor bank and feeder SFU & MCCB 63 Amp., 25 KA with APFCrelay in 9 steps & other acceessories to adjust automatically the power factor upto 0.99. 608 Power and control cables 609 1100 V grade, 3 core 70mm2 PVC insulated PVC sheathed Aluminium Armoured conductor cablefrom LT panel to motor.(1x3x40 mtr.) 610 Control cable 1x10C, 1.5 mm2 PVC insulated PVC sheathedCopper conductor cable for moisture sensor Reverse protection thermistor relay etc. 611 EARTHING 612 Complete earthing of all the equipments as detailed above shall be done as per IS/IER/PWD specification with G.I Plates, watering pipe and loop earthing with adequate size of G.I/ Al. strip etc. (PS-702) 02 Nos. each of the equipment(3 Nos Pumps + 1 No. LT Panel + 1 No. PLC Panel.) size of earthing plate 600mm x 600mm x6 mmwith salt and coal. 613 Lighting system: 614 Supply & erection of M.S. Tubular Poles SP-36, 9.5 M height. 615 S/F of 72 watt LED with lumen reflector. 616 Feeder pillar for lighting 617 Supply and laying of 4x16mm2 Al. armoured cable. 618 Internal electrification with fixtures. 619 S/F 1200 mm ceilingFan for LT Room 620 S/F of exhaust Fan for LT Room, VCB room. 621 Earthing of street light pole (SOR-41) 622 Painting of street light (P5-634) 623 Supply and installation of DCP type of 5 Kg. Fire existinguisher(PS-1132) 624 12 mm thick rubber mating for safe working on. 625 Tools 626 Hydrulic crimping tools-Crimping range: 16-300 sq.mm.,Weight: 6 Kg. ,Length: 500mm,Make/ Model:YQK300 627 Mannual crimping tools-Crimping range: 400 sq.mm.,Make/ Model: Crimp well 628 Tong tester (AC/DC-1000A, make-Rishabh)Multimeter (AC/DC-1000A,make-Meco)Megger (AC/DC-500V make-Rishabh)Screwdriver (6"x 12", make- Taparia)Plier (250mm, make-Taparia) 629 Chain wrench (12"x18", make Taparia) Pipe wrench (1200mm, make Taparia) 630 Installation of above equipments ,Pumsets and Panels etc. complete. 631 Testing of pumping plantand Panels etc. complete at works 632 Commissioning of pumping plantsand Panels etc. complete 633 Chequered plate of required size so as to cover all trenches. 634 Power Distribution Transformer : 635 Supply of Oil immersedOutdoor type Power distribution transformer 11/0.433 KV rating 200 KVA double wound with copperwinding, Level-1, vector group dyn 11, ONAN with manually operated ± 5.0 % off load tap changer in step of 2.5% and complete with standard fitting & accessories. 636 Supply and laying of 1100 voltage grade ,2x3.5Cx 95 mm2 Aluminium conductor, XLPE armoured cable from Transformers to LT Panel. 637 Double Earthing of Transformers consisting of 04 nos. Earthing Pit (two for each neutral and body) with Al/GI. strip size 25X6mm, the minimum distance between to earthing pits, Double Earthing works and all electrical equipments shall be as per IS and IER. 638 Installation , testing and Commissioning of Transformer complete. 639 H.T. Switch Gear Panel : 640 Supply of 12 KV,H.T. V.C.B. Panel with one incoming & two out going ,630 Amp. (25 KA) Rating have followings- 641 Incommer Feeder- 01 No. 642 3 O/C + 1 EF IDMT Characteristics Relays based Incommer control panel equiped with over current & earth fault relay with core balance C.T., master trip relay, instantaneous under voltage realy & Auxilliary realy etc.C.T.ratio 30-20/5A Dual core, Class-1 for measurement core & 5P10 for protection core & PT 11KV/110 VAC. KWH meter, power factor meter, frequency meter. Amp. meter 0-20& volt meter 0 to12 KV. All relays required separately conventioal type 24 to 30 VDC, 110 VAC. 643 Outgoing Feeder- 02 Nos. 644 outgoing feeder control panel equiped withtriple pole 2 O/C + 1 E/F relay with IDMT & intantaneous characterisstics, mater trip relay & Auxilliary relay for Buchhloz alarm / trip, OTI alram / trip & WTI alram/trip, etc.C.T.ratio 30-15/5A, Class-1 for measurement core & 5P10 for protection core. 645 DC Supply 646 SICT battery bank, exide make, consisting of 16 cells, 2 volt each for supply VDC 24 to 30 Volt with battery charger of approved make with suitable M.S. Stand / Trolley, equipment fittings with accessories etc. 647 Supply and laying of 1x3Cx95 mm 2 ,11 KV HT Al. XLPE cable from metering panel to H.T. Panel and form H.T. Panel to both transformers. 648 CE/UL approved manufacturer"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. 649 Auto phase reversal unit -Auto phase reversal unit/ automatic transfer switch withinbuilt time delay & enclosure of SuitableAmpere rating (Confirming to IEC: 60947-1 and IEC: 60947-b-1)as specified in tender technical specification sheet.250amp 650 CE / UL approved manufacturer’s Radartype Level Transmitter for CWR as specified in tender technical specification sheet 651 CE / UL approved manufacturer’s Pressure Transmitterin main header line of Pump as per specifications specified in tender technical specification sheet. 652 CE & UL certified Surge protector for control panel 653 CE & UL certified pressure transmitter for each pump 654 Complete cabling for ZPS including all power and control cable of all equipments at ZPS 655 Security Surveillance IP Camera with Recorer 656 S/F of XLPE cable End termination box 657 Indoor end termination box. 658 Earthing ofH.T Panel as per IS & IER. 659 Testing & Commissioning of HT Panel etc. 660 Erection of All sub staion equipments and fencing with iron mesh etc. complete in all respect. 661 Commissioning of All sub station equipments etc. complete in all respect. 662 Zone-2C 663 New Tubewell of size 300x200 mm. dia by D.C./RC Rig Machine 664 Drilling of borehole for Tubewell contruction by RC Rig Machine including transportation, erection, dismantling of Rig and assoiated T & P complete in all respect including required all material, labour etc. 665 Transportation, Erection and Dismantling of Rig Machine 666 Drilling of 600mm size bore from GL to 60 BGL 667 Drilling of 500mm size bore from 668 60M BGL to 100MBGL 669 100M BGL to 150MBGL 670 Tubewell Assembly 671 M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support structer etc. As required & as per typed design complete in all respect. 672 300 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm. 673 200 mm. Dia MS ERW slotted/ casing pipe having wall thickness of 7.1mm. 674 Supply of pea gravel 675 Logging of bore hole by departmental / approved electric logger. 676 Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect. 677 Lowering of 300mm dia pipe from GL to 54m deep BGL. 678 Lowering of 200mm dia pipe from 54 to 100m deep BGL. 679 Lowering of 200mm dia pipe from 100 to 135m deep BGL. 680 Development of Tubewell by compressor 681 Transportation, Installation and Dismantling of 250 PSI Compressor 682 Development of Tubewell by 250 PSI Capacity Air compressor 683 Development of Tubewell by O.P. Unit 684 Transportation, Installation and Dismantling of 2 Cusec O.P. Unit & Yield Test. 685 Development of Tubewell by 2 Cusec Capacity by O.P. Unit 686 Chemical and Bacterological test of water sample from depaprtmental/ approved lab. 687 PUMPING PLANT OVER A REBORE TUBEWELL AT ZONE-2C, T.W.-1 (Avas vikas TW 21) 688 SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1800 LPM, 57m head, 40 HP 689 Soft starter with RS-485 port-400V Class30 Kw rating or above as per site requirement. 690 01 KVAR UPS at TW Panel 691 150 mm size motor operated actuator with Sluice valve 692 Capacitor Bank 10 KVAR with Relay 693 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. 694 CE/UL approved manufacturer"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. 695 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 696 CE & UL certified pressure transmitter 697 Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) 698 CE & UL certified Surge protector for above control panel 699 Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . 700 Copper cable size 2x3cx10 sq mm. flat for 18 m extra column pipe. 701 Supply & Laying of PVC insulated Al. armoured cable size 1x3.5/4Cx50 sq mm. from transformer LV side to meter panel and meter panel to starter. 702 SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. 703 SITC of 03 Phase Servo Voltage Stabilizer 60 KVA. 704 PUMPING PLANT OVER A NEW TUBEWELL AT ZONE 2C, T.W.-1 & 2 705 SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1800 LPM, 57m head, 40 HP 706 Soft starter with RS-485 port-400V Class30 Kw rating or above as per site requirement. 707 01 KVAR UPS at TW Panel 708 150 mm size motor operated actuator with Sluice valve 709 Capacitor Bank 10 KVAR with Relay 710 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. 711 CE/UL approved manufacturer"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. 712 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 713 CE & UL certified pressure transmitter 714 Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) 715 CE & UL certified Surge protector for above control panel 716 Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . 717 Copper cable size 2x3cx10 sq mm. flat for 18 m extra column pipe. 718 Supply & Laying of PVC insulated Al. armoured cable size 1x3.5/4Cx50 sq mm. from transformer LV side to meter panel and meter panel to starter. 719 SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. 720 SITC of 03 Phase Servo Voltage Stabilizer 60 KVA. 721 ELECTRICAL / MECHANICAL WORKFOR NEW OVERHEAD TANK AT IPS 3 CAMPUS SHANTI NIKETAN2200 KL (ZONE - 2C) 722 Motor operated Actuators with Sluice valve of size 400 mm. at distribution line. 723 CE & UL certified Electomagnetic Flowmeter for OHT line size 400 mm. dia. 724 Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system too. 725 CE/UL Certified suitable capacity UPS with batteries. 726 SCADA SYSTEM FOR ALL TW OF ZONE-2 WITH CWR 727 (A) ZONE- 2A EXISTING TUBEWELL NO. T.W.-1 ( AVAS VIKAS FIRST TW 31), & T.W.-2 ( AVAS VIKAS FIRST TW 32), 728 Repairing & overholing of all existing scada automation related equipement including restatoration of existing RTU/PLC panels with all required material complete in all recpect. 729 (B) ZONE- 2A EXISTING T.W.No.-3 ( AVAS VIKAS OLD OHT CAMPUS REBORE TW NEWLY CONSTRUCTED BY NAGAR PALIKA PARISHAD FROMC&DS UNIT (2023)TW No. 11), 730 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. 731 G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. 732 CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. 733 Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) 734 Installation, commissioning & testing for one tubewell 735 Trial run for three month period for tubewell 736 (A) ZONE- 2B EXISTING TUBEWELL NO. TW No.-1 (HARISHCHANDER NAGAR TW No. 10) & T.W.-2 ( BABUPURA TW No. 14) 737 Repairing & overholing of all existing scada automation related equipement including restatoration of existing RTU/PLC panels with all required material complete in all recpect. 738 (B) ZONE- 2B EXISTING TW No.3 (REBORE TW NEWLY CONSTRUCTED BY NAGAR PALIKA PARISHAD FROMC&DS UNIT (2023)TW DEVIPURA BANDH) 739 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. 740 G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. 741 CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. 742 Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) 743 Installation, commissioning & testing for one tubewell 744 Trial run for three month period for tubewell 745 (C) ZONE- 2B NEW T.W.- 1 (CWR CAMPUS) & TW -2 (Not define) 746 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. 747 G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. 748 CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. 749 Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) 750 Installation, commissioning & testing for one tubewell 751 Trial run for three month period for tubewell 752 (A) ZONE- 2C REBORE TUBEWELL NO. 01(Avas vikas TW 21) 753 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. 754 G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. 755 CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. 756 Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) 757 Installation, commissioning & testing for one tubewell 758 Trial run for three month period for tubewell 759 (B) ZONE- 2C NEW TUBEWELL 2 NOS. (TW NO. 1 & 2) 760 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. 761 G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. 762 CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. 763 Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) 764 Installation, commissioning & testing for one tubewell 765 Trial run for three month period for tubewell 766 (C) COST OF INTEGRATION 767 Cost of integration of Tubewells and OHT with MCS/ LCS 768 S.I.T.C OF SCADA SYSTEM FOR C.W.R. HAVING 03 NO. PUMPS 769 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each ZPS/ OHTto store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. 770 G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. 771 CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. 772 Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) 773 Installation, commissioning & testing for CWR 774 S.I.T.C OF SCADA SYSTEM FOR EXISTING OVERHEAD TANK AWAS VIKAS 1st2200 KL AT (ZONE 2A) 775 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations 776 G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges . 777 Renovation / Restoration of SCADA at existing OHT 778 CE & UL certified Radar type level transmitter for OHT 779 S.I.T.C OF SCADA SYSTEM FOR NEW OVERHEAD TANK AT LADIES THANA 2200 KL AT 2200 KL (ZONE 2B) 780 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations 781 G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges . 782 CE & UL certified Radar type level transmitter for OHT 783 S.I.T.C OF SCADA SYSTEM FOR NEW OVERHEAD TANK AT IPS 3 CAMPUS SHANTI NIKETAN2200 KL (ZONE - 2C) 784 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations 785 G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges . 786 CE & UL certified Radar type level transmitter for OHT 787 03 MONTH TRIAL & RUN OF PUMPING PLANT OF TUBEWELL FOR ZONE 2A 788 03 Month trial & run of Pumping Plant for 03 Nos. existing tubewell including liquid Chlorine, Operating Staff. Excluding Electricity Charges. 789 03 MONTH TRIAL & RUN OF PUMPING PLANT OF TUBEWELL FOR ZONE 2B 790 03 Month trial & run of Pumping Plant for 02 Nos. new tubewells & 02 nos. existing tubewells including Operating Staff. Excluding Electricity Charges. 791 03 MONTH TRIAL & RUN OF PUMPING PLANT OF CLEAR WATER RESERVIOR OF ZONE 2B 792 03 Month trial & run of Pumping Plant for 01 No. CWR including liquid Chlorine & Operating Staff. Excluding Electricity Charges. 793 03 MONTH TRIAL & RUN OF PUMPING PLANT OF TUBEWELL FOR ZONE 3C 794 03 Month trial & run of Pumping Plant for 02 Nos. new tubewells & 01 no. rebore tubewell including liquid Chlorine, Operating Staff. Excluding Electricity Charges. 795 PART-C (Nagar Palika Parishad water supply Reorganization scheme Zone-03) 796 Civil Work 797 Construction ofRCC Overhead Tank of 2400 KL Capacity at 26 m Staging from made up level (Made Up Level of OHT will be taken as 0.70 m above from newrby existing approach road level) in M-30 grade of concrete.(Sub Zone-3c) 798 Submission of design, drawing and supply of all material, labour T&P etc. and construction as per tenderer"s own provided seismic proof design and drawings (approved by the department) complete Intze type tank, on raft or pile cum raft foundation with columns and braces R.C.C. Over Head Tank 2400 KL capacity at 26 m staging from made up level of OHT at site to the top of bottom ring beam of tank. Made up level of OHT will be taken as 0.70 m above from nearby existing approach road level.Earth required for made up level & Brick work required for apron will be arranged by the contractor at his own cost. No extra payment will be paid for this work. The design of the tank shall be based on safe bearing capacity of soil at site as 7 T/m2 and depth of foundation as 3.0 m from existing ground level on pile/raft foundation. If the bearing capacity of soil is found less than 7 T/m2 as per test report, the contractor will submit the design on the B.C. proposed by the NABL approved reputed testing agency. No extra payment will be made for this change. If the B.C. is found more than 7 T/m2 as per testing report than the design of OHT shall be done at B.C 7 T/m2 and depth 2.50m or the depth suggested by testing agency (greater of the two depths). All other details of tank not covered here shall also be as per specifications enclosedITEM 799 & 800 ARE SOME DETAILS (NOT LIMITED TO) OF WORK WHICH ARE TO BE DONE DURING CONSTRUCTION OF OHT AND THEIR COST IS INCLUDED IN ITEM 798. (NO EXTRA PAYMENT WILL BE CLAIMED/MADE). 799 Soil testing Submission of detailed design and drawing including its vetting shall be done from any recognized Government University such as I.I.T./NIT/State Govt./ Centre Govt.institutions / organizations or as per direction of Engineer-in-charge.R.C.C. work will be strictly as per approved design including fixing various pipes and S.S ventilator at the top and fixing of S.S. sheet of 10 mm gauge manhole cover of 60 cm x 60 cm size with frame and locking arrangement and railing including supply of all material complete in all respect. Water bar"s / water stoppers of 18mm gauge and 30 cm wide (15cm below the joint and 15cm above the joint) along the joint of cylindrical wall of over head tank at every lift / joint should be provided.Supply and fixing of S.S. ladder, inside the tank body from roof to the bottom dome of the tank in a slope of 3: 1 (3 vertical: 1 horizontal) with railing as specified.Railing on double column staircase & its landings, all around balcony & top dome for access up to ventilator as per specifications including supply of all material. Railing shall be provided in three rows of G.I. pipe (medium) 20mm dia. (min.). Box type enclosure at the entrance of the staircase upto first landing having locking arrangement should be provided.Supply and fixing of digital water level indicator along with all necessary equipments such as inverter etc. as per specifications and fixing of lightening arrestor, conductor and earth plate etc. as per specifications. 800 Supply of all materials and construction of 100 mm thick R.C.C. floor apron and 15 cm dia. semi circular drain around apron in a slope towards wash out chamber with glass strips, with base concrete 1:3:6 with stone ballast of thickness 150mm.Three coats of approved quality and shade of Apex ultima Paintas per direction of Engineer-in-charge over concrete work including supply of all materials etc. Three coats of anti corrosive / aluminum / black Japan paint of approved quality on all iron work including supply of all material, labour and T&P etc complete in all respect.Supplying and fixing of all required sizes C.I. D/F sluice valves kirloskar make , RCC overflow chamber & Sluice Valve Chamber as per relevant latest I.S. specifications at below ground level or as per direction of E/I including supply of all jointing and other make materials such as rubber insertion sheet, nut bolts, washer etc, complete as per Specifications.Supply and fixing of following pipes:-Inlet pipe- 450 mm dia;DMA -1 Outlet pipe-400mm diaDMA -2 Outlet pipe-400mm diaOver flow pipe - 500 mm dia Wash out pipe-100 mm dia .The words U.P. Jal Nigam (Urban), year of construction, capacity of O.H.T. with staging and slogan approved by Engineer in charge shall be painted prominently in Block Letters not less than 30 cm in height. Testing of tank for water tightness as per specifications enclosed/ as per CPHEEO Manual including supply of water. Trial & Run of 3 months, maintenance of work ( till handing over or date of shedule complision whichever is later) and defect liability period of 12 months after handing over to NagarPalika Parishad Bulandshahr. including supply of all materials, labour, T&P etc. complete in all respect. 801 Supply of all materials labour T&P etc. complete and construction of R.C.C. (M30 Grade) CWR of 800 KL capacity awith main components, including cost of soil testing. 802 All the components of C.W.R will be casted in M30 concrete with cement, coarse sand and approved stone grit as per I.S. 11682 and I.S.456 803 Minimum depth of foundation below original ground level will be 4.5M 804 Seismic effects and wind load should be taken into consideration as I.S. 1893 for earthquake resistance and I.S. 875 part-III for wind load on structure (this area is in seismic Zone IV and high damage risk zone for wind) 805 The above cast of C.W.R has been assumed that ,the bearing capacity of soil has been taken as 8 M.T.sqm. 806 Proper ventilator at top dome in circular shape of 8 m dia. along with an R.C.C. cover of minimum 1.50m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia.The space between top dome and R.C.C. cover should be covered with mosquito net of standard quality along with expanded metaled jali. 807 Water level indicator fabricated with good quality minimum 45mm x 45mm x 6mm M.S.angle and 3mm thick 6mm flat M.S.sheet. The indicator board scale made of 3mm thick M.S. plate should have a clear width of minimum 25cm painted with good Asian paint. It should also consists of 3mm brass wire rope minimum 4 smooth pulleys about 8 cm dia with guides,15cm dia copper ball float which shall be completely water tight suitable pointer of brass etc. 808 Lightening conductor as per I.S.S.2309 of its latest amendments of latest electricity rules. It should consist proper elevation rod with 5 or more fork points proper down conductors of prescribed metal of proper size prescribed by ISS 2309-1969 and ISS 3013-1966 809 C.I. manhole of min 60x60cm size made of M.S.channel section with adequate cover made of M.S. sheet of minimum 3mm thickness hinged with manhole with locking aarrangement.This manhole should be fixe at top dome at proper place. 810 Construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit under each duck foot bend to support the vertical pipes. These bed blocks should supported on the raft not on the soil . 811 Painting of all concrete surface and steel pipe works with three coats of approved cement paint and anticorrosive paints. 812 Construction of pump house, chlorinating room,MCS room, Boundary Wall with gate and approach road works 813 Supply of all materials and construction of pump house of size (3.6 m x 3.0 m x 3.0 m) cum chlorinating room size (1.80mx 2.60 m x 3.00 m) . (As per type design of UPJN (Urban). 814 Construction of Stilling chamber (1.50 m x 1.50 m x 1.00 m) and V Noch for bye-pass Arrangement of Tubewells complete in all respect as per direction of Engineer in Charge. 815 Construction of MCS at NPP Bulandshahr centralized control room including supply of all materials, labour, T&P etc. complete in all respect as per direction of Engineer in Charge. 816 Construction of boundary wall around water works compound.(As per type design of UPJN (Urban)). 817 Construction of 300 x 300 mm size drain inwater works compoundincluding supply of all materials, labour, T&P etc. complete in all respect as per direction of Engineer in Charge 818 Supply and fixing 3.6M & 1.20M wide MS Gate with pillers including fabrication and supply of steel and construction of boundary pillars etc. complete for pump house complete in all respect as per direction of Engineer in Charge. 819 Recharge unit (RWH) of ground water by rooftop rainwater of pump house and water available of byepass arrangement of tubewell and washout as per drawing including supply of all material T&P to the satisfaction of E-In-C 820 Supply & laying of 80mm cement interlocking tiles for approach road including 100 mm thick P.C.C. 1:6:12supply of all materials, labour, T&P etc. complete in all respect as per direction of Engineer in Charge. 821 Laying of Rising Main pipe line & appurtenent works 822 Excavation of earth in ordinary soil (loam, clay or sand) for laying of pipe line including refilling, ramming, dressing, leveling of trenches in 30 cm layers anddisposal of surplus earth for different size of pipe lift up to 1.5m and 500 m awayas per direction of Engineer in Charge . If any Utilities are damaged during excavation (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work. 823 Supply of D.I. pipe line into trenches true to alignment & agradient including Supply of D.I. D/F specials, F.O.R. destination and all taxes and insurance etc. cost of all labour, T&P, jointing, materials,specials, testing of pipe line etc. complete. 824 D.I. pipe Class-K-9 825 200 mm dia 826 450 mm dia 827 Carting laying & jointing of D.I. pipe line into trenches true to alignment & agradient including cost of all labour, T&P, jointing, materials,specials, testing of pipe line etc. complete.If any Utilities are damaged during carting or laying or jointing (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work. 828 D.I. pipe Class-K-9 829 200 mm dia 830 450 mm dia 831 Supply of following size and carting upto site of work, lowering, fixing and jointing of followingfittings in trenches including cost of all materials such as rubber packing, nut bolts etc. complete work. 832 C.I.D/F Sluice Valve IS 780-1984 833 200 mm dia 834 450 mm dia 835 THRUST BLOCK 836 Provision forR.C.C. Thrust Block with cement, coarse sand & 20 mm gauge stone ballast in proportion of 1:1.5:3 in pipe line including supply of reinforcement and its fixing and binding the same with 0.50 mm thick binding wire on position and necessary centering & shuttering complete for proper completion of work including supply of steel and wastage etc. 837 Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. 838 Bituminous Road 839 Interlocking Road 840 Cement Concrete Road 841 Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. 842 Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) 843 Interlocking Road (Using 60% old tiles including spreading of local sand and base concrete in 1:6:12 ,10 cm thickness) 844 Cement Concrete Road (100mm thickness of1:2:4 cement concrete over base of 100mm thickness of 1:4:8 Lean concrete) 845 Sluice Valve Chamber (Masonary Type) 846 Provision for crossings of nalas & culvert including sifting of telephone cables etc. Along the alignment of pipeline including supply of C.I. tyton pipe andspecials etc. complete. (3.0 M.Wide Road) 847 Laying of Distribution pipe line & other appurtenent works 848 Excavation of earth in ordinary soil (loam, clay or sand) for laying of pipe line including refilling, ramming, dressing, leveling of trenches in 30 cm layers anddisposal of surplus earth for different size of pipe lift up to 1.5m and 500 m awayas per direction of Engineer in Charge . If any Utilities are damaged during excavation (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work 849 Supply of following size of pipes including all types of specials, railways frieght and cartage up to store , all taxes and duties complete as per direction of Engineer-in-charge. 850 HDPE Pipe (PE-100) 851 110 mm dia 852 140 mm dia 853 160 mm dia 854 DI Pipe Class K-7 855 200 mm dia 856 250 mm dia 857 300 mm dia 858 350 mm dia 859 400 mm dia 860 Carting ,laying and jointing of the following sizes of pipes into the trenches includingall types of specials, cost of all jointing materials,making interconnection & specials, labour and T & P , testing etc. completeas per direction of Engineer-in-charge.If any Utilities are damaged during carting or laying or jointing (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work. 861 HDPE Pipe (PE-100) 862 110 mm dia 863 140 mm dia 864 160 mm dia 865 DI Pipe Class K-7 866 200 mm dia 867 250 mm dia 868 300 mm dia 869 350 mm dia 870 400 mm dia 871 Supply and fixing & carting of following types of fittings including railway frieght, cartage up to site, all taxes and duties etc. complete. 872 (A) C. I. Sluice Valveas per latest IS specifications 873 100 mm dia 874 125 mm dia 875 150 mm dia 876 200 mm dia 877 250 mm dia 878 Scour Valve 80 mm dia 879 CI Single ball type Air Valve 20 mm dia 880 Fire Hydrants 80 mm dia 881 Supply of all materials, labour, T&P for construction of following types of chambers as per departmental drawing & design. 882 Sluice Valve Chamber (Masonary Type) 883 Sluice Valve Chamber (Surface Box Type) 884 Fire Hydrant Chambers 885 Air Valve Chambers 886 Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. 887 B.O.E. 888 C.C. Interlocking Tiles Road 889 C.C. Road 890 Bituminous Road 891 Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. 892 B.O.E Road (60% old and 40% new Bricks) 893 Laying of 80mm thick C.C. Interlocking Tiles Road with 40% new Tiles including dressing surface and including supply of tile,including all labour T&P etc. required for proper completion of work. 894 Cement Concrete Road (100mm thickness of1:2:4 cement concrete over base of 100mm thickness of 1:4:8 Lean concrete) 895 Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) 896 Provision for crossings of nalas & culvert including shifting of telephone cables etc. along the alignment of pipeline including supply of C.I. tyton pipe andspecials etc. complete in all respect as per direction of Engineer in Charge. 897 For up to 1.5 M wide 898 For up to 1.5 M to 3.0 M wide 899 For above 3.0 M wide 900 Making New Water House Connection with Distribution main including Dismantling & permanent reinstatement in all types of road , supply , carting of specials lowering them into trenches, fixing them including bailing out of water necessary excavation for connection including all labour , T&P etc. required for proper completion of the works as per direction of engineer - in- Charge. 901 For 90 mm to 500mm dia (HDPE Pipe/ DI ) 902 Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. 903 B.O.E. 904 C.C. Interlocking Tiles Road 905 C.C. Road 906 Bituminous Road 907 Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. 908 B.O.E Road (60% old and 40% new Bricks) 909 Laying of 80mm thick C.C. Interlocking Tiles Road with 40% new Tiles including dressing surface and including supply of tile,including all labour T&P etc. required for proper completion of work. 910 Cement Concrete Road (100mm thickness of1:2:4 cement concrete over base of 100mm thickness of 1:4:8 Lean concrete) 911 Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) 912 Maintenance works 913 Repairing of OHT 2250KL/22 M staging due to seepage in bottom dome, conewall & vertical wall after chiseling the loose concerete and ensuring water tightness of the OHT & repairing of 200 mm to 500 dia sluice valveincluding Scrapping and chiseling of plaster, providing and applying one coat of slurry of hydrophilic in nature for waterproofing treatment from the internal surface of Over Head Tank, required thickness plaster with chemical coding, supply and fixing of scaffolding, painting, colour washing, with Asian Apex Paint, stacking/proper disposal of dismantled plaster material, repairing of staircase including supply and fixing of GI pipe hand rail, vertical post and also repairing of minor defect in landing, riser and tread, Supply & fixing of Proper ventilator at top dome in circular shape along with an R.C.C. cover of minimum 1.50m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia., Lightening conductor as per I.S.S.2309 of its latest amendments of latest electricity rules, C.I. manhole of min 60x60cm size made of M.S.channel & Painting of all concrete surface and steel pipe works with all labour, material T&P complete in all respect as per direction of Engineer in Charge. 914 Repairs of boundary wall Supply all materials, labour, T&P etc. Required for proper completion of work complete in all respect as per direction of Engineer in Charge. 915 Interconnection in existiing distribution main with supply all material ,specials labour dismantling and reinstatementof all types of road etc complete in all respect. 916 E & M work 917 Zone 3 918 Zone-3B 919 New Tubewell of size 300x200 mm. dia by D.C./RC Rig Machine 920 Drilling of borehole for Tubewell contruction by RC Rig Machine including transportation, erection, dismantling of Rig and assoiated T & P complete in all respect including required all material, labour etc. 921 Transportation, Erection and Dismantling of Rig Machine 922 Drilling of 600mm size bore from GL to 60 BGL 923 Drilling of 500mm size bore from 924 60M BGL to 100MBGL 925 100M BGL to 150MBGL 926 Tubewell Assembly 927 M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support structer etc. As required & as per typed design complete in all respect. 928 300 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm. 929 200 mm. Dia MS ERW slotted/ casing pipe having wall thickness of 7.1mm. 930 Supply of pea gravel 931 Logging of bore hole by departmental / approved electric logger. 932 Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect. 933 Lowering of 300mm dia pipe from GL to 54m deep BGL. 934 Lowering of 200mm dia pipe from 54 to 100m deep BGL. 935 Lowering of 200mm dia pipe from 100 to 135m deep BGL. 936 Development of Tubewell by compressor 937 Transportation, Installation and Dismantling of 250 PSI Compressor 938 Development of Tubewell by 250 PSI Capacity Air compressor 939 Development of Tubewell by O.P. Unit 940 Transportation, Installation and Dismantling of 2 Cusec O.P. Unit & Yield Test. 941 Development of Tubewell by 2 Cusec Capacity by O.P. Unit 942 Chemical and Bacterological test of water sample from depaprtmental/ approved lab. 943 PUMPING PLANT OVER AEXISTING (REBORE) TUBEWELL N0.-1 AT ZONE-3B(SHIVPURI) TUBEWELL CONSTRUCTED BY NAGAR PALIKA PARISHAD, BULANDSHAHR AND TO BE COMMISSIONED BY THEM 944 Soft starter with RS-485 port-400V Class30 Kw rating or above as per site requirement. 945 01 KVAR UPS at TW Panel 946 150 mm size motor operated actuator with Sluice valve 947 Capacitor Bank suitable capacity KVAR with Relay 948 CE/UL approved manufacturer"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. 949 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 950 CE & UL certified Electromagnatic Flowmeter suitable for above line size 150 mm. 951 CE & UL certified pressure transmitter 952 SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. 953 CE & UL certified Surge protector for above control panel 954 Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) 955 Complete cabling of tubewell including all power and control cables of all equipment at pump house. 956 CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. 957 Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) 958 SITC of 03 Phase Servo Voltage Stabilizer 60 KVA. 959 Dismantling of existing pumping plant 960 Installation of above pumping plant including commissioning & testing complete. 961 PUMPING PLANT OVER A NEW TUBEWELL AT ZONE 3B T.W.-1 & 2 962 SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1800 LPM, 55m head, 40 HP orsuitable capacity. 963 Soft starter with RS-485 port-400V Class30 Kw rating or above as per site requirement. 964 01 KVAR UPS at TW Panel 965 150 mm size motor operated actuator with Sluice valve 966 Capacitor Bank suitable capacity KVAR with Relay 967 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. 968 CE/UL approved manufacturer"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. 969 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 970 CE & UL certified Electromagnatic Flowmeter suitable for above line size 150 mm. 971 CE & UL certified pressure transmitter 972 SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. 973 CE & UL certified Surge protector for above control panel 974 Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) 975 CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. 976 Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) 977 Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . 978 Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. 979 Supply & Laying of PVC insulated Al. armoured cable size 1x3.5/4Cx35 sq mm. from transformer LV side to meter panel and meter panel to starter. 980 SITC of 03 Phase Servo Voltage Stabilizer 60 KVA. 981 ELECTRICAL / MECHANICAL WORKFOR EXISTING OVERHEAD TANK 2250 KL (ZONE 3B) 982 Motor operated Actuators with Sluice valve of size 400 mm. at distribution line of DMA-1 ofsub zone 3B 983 CE & UL certified Electomagnetic Flowmeter of size 400 mm of DMA-1 ofsub zone 3B 984 Motor operated Actuators with Sluice valve of size 350 mm. at distribution line of DMA-2 ofsub zone 3B 985 CE & UL certified Electomagnetic Flowmeter of size 350 mm of DMA-2 ofsub zone 3B 986 Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system too including PH compensator for DMA-1 & 2 987 CE/UL Certified suitable capacity UPS with batteries. 988 CE & UL certified Radar type level transmitter for OHT 989 ELECTRICAL / MECHANICAL WORKFOR EXISTING OVERHEAD TANK 2200 KL OFSUB ZONE (1B+3A) FOR(ZONE-1) 990 Sub Zone 1B OF SUB(1B+3A) FOR ZONE -1 991 Motor operated Actuators with Sluice valve of size 300 mm. at distribution line of DMA-1 ofsub zone 1B 992 CE & UL certified Electomagnetic Flowmeter of size 300 mm of DMA-1 ofsub zone 1B 993 Sub Zone 3A OF SUB(1B+3A) FOR ZONE -1 994 Motor operated Actuators with Sluice valve of size 400 mm. at distribution line of DMA-1 ofsub zone 3A 995 CE & UL certified Electomagnetic Flowmeter of size 400 mm of DMA-1 ofsub zone 3A 996 Motor operated Actuators with Sluice valve of size 300 mm. at distribution line of DMA-2 ofsub zone 3A 997 CE & UL certified Electomagnetic Flowmeter of size 300 mm of DMA-2 ofsub zone 3A 998 Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system too including PH compensator for DMA-1 & 2 999 Zone-3C 1000 New Tubewell of size 300x200 mm. dia by D.C./RC Rig Machine 1001 Drilling of borehole for Tubewell contruction by RC Rig Machine including transportation, erection, dismantling of Rig and assoiated T & P complete in all respect including required all material, labour etc. 1002 Transportation, Erection and Dismantling of Rig Machine 1003 Drilling of 600mm size bore from GL to 60 BGL 1004 Drilling of 500mm size bore from 1005 60M BGL to 100MBGL 1006 100M BGL to 150MBGL 1007 Tubewell Assembly 1008 M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support structer etc. As required & as per typed design complete in all respect. 1009 300 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm. 1010 200 mm. Dia MS ERW slotted/ casing pipe having wall thickness of 7.1mm. 1011 Supply of pea gravel 1012 Logging of bore hole by departmental / approved electric logger. 1013 Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect. 1014 Lowering of 300mm dia pipe from GL to 54m deep BGL. 1015 Lowering of 200mm dia pipe from 54 to 100m deep BGL. 1016 Lowering of 200mm dia pipe from 100 to 135m deep BGL. 1017 Development of Tubewell by compressor 1018 Transportation, Installation and Dismantling of 250 PSI Compressor 1019 Development of Tubewell by 250 PSI Capacity Air compressor 1020 Development of Tubewell by O.P. Unit 1021 Transportation, Installation and Dismantling of 2 Cusec O.P. Unit & Yield Test. 1022 Development of Tubewell by 2 Cusec Capacity by O.P. Unit 1023 Chemical and Bacterological test of water sample from depaprtmental/ approved lab. 1024 PUMPING PLANT OVER A NEW TUBEWELL AT ZONE - 3C TW-1 (CWR CAMPUS) & 2, 3 , 4 1025 SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1900 LPM, 29m head, 20 HP orsuitable capacity. 1026 Soft starter with RS-485 port-400V Class15 Kw rating or above as per site requirement. 1027 01 KVAR UPS at TW Panel 1028 150 mm size motor operated actuator with Sluice valve 1029 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. 1030 CE/UL approved manufacturer"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. 1031 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 1032 CE & UL certified pressure transmitter 1033 CE & UL certified Surge protector for above control panel 1034 Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) 1035 CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. 1036 Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) 1037 Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . 1038 Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. 1039 Supply & Laying of PVC insulated Al. armoured cable size 1x3.5/4Cx35 sq mm. from transformer LV side to meter panel and meter panel to starter. 1040 SITC of 03 Phase Servo Voltage Stabilizer 30 KVA. 1041 ELECTRICAL / MECHANICAL WORKFOR NEW OVERHEAD TANK 2200 KL (ZONE 3C ) 1042 Motor operated Actuators with Sluice valve of size 400 mm. at distribution line of DMA-1 ofsub zone 3C 1043 CE & UL certified Electomagnetic Flowmeter of size 400 mm of DMA-1 ofsub zone 3C 1044 Motor operated Actuators with Sluice valve of size 400 mm. at distribution line of DMA-2 ofsub zone 3C 1045 CE & UL certified Electomagnetic Flowmeter of size 400 mm of DMA-2 ofsub zone 3C 1046 Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system too including PH compensator for DMA-1 & 2 1047 CE/UL Certified suitable capacity UPS with batteries. 1048 CE & UL certified Radar type level transmitter for OHT 1049 S.I.T.C. OF PUMPING PLANTS & ELECTRIC SUBSTATION IN PROSPECTIVE TO C.W.R. 1050 PumpSet at C.W.R: 1051 Pump Set :Elecrtic Driven Self Water lubricated V.T. Pumping set 3700 LPM, 40 m head with soft starter drive complete in all respect discharge head assembly and strainer with 6m column pipe length complete with 60 HP or suitable capacity VHS TEFC type induction motor SCADA compatible IP-55, 50 Hz Class-F insulation 3 phase AC supply, 415+ 6% - 10% voltsat speed 1460 RPM. MOC :Impeller : CF8MCasing : 2% Ni CI IS:210, FG: 260Shaft : AISI 410Total 03 Nos. Pumpset are proposed in module of operation in 2 Nos. are working, 1 Pump is standby. 1052 Soft starter with RS-485 port-400V Class55 KW rating or above as per site requirement. 1053 Cast iron pipes & specials. 1054 Supply ofgalvanized nut- Bolt SS-304 and rubber packing material for erection of above. 1055 Sluice Valve : 1056 DI Sluice Valve 200 mm with actuator 1057 Reflex Valve 1058 DI DF double flanged single/multi door swing check valves PN 1.0 FG200 Grade having body comprising inlet & outlet sheets in gradeed cast iron diaphragm fitted woth st. steel, faces,diaphragm plate and door , sub pins and shall be of following sizes: 1059 200 mm dia 1060 250 mm dia 1061 DI Dismantling joints 1062 200 mm dia 1063 250 mm dia 1064 Electrical operated Travelling Trolley (E.O.T) crane compatible for longi tudinal and transverse motion both of 3 Tone capacity with 6 meter lift alongwith traveling trolley and girder etc. 1065 Automatic Chlorinating Plant 1066 SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steadt state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. 1067 CE & UL certified Electomagnetic Flowmeter at common header size 250 mm. dia. 1068 L.T. Panel BoardConforming to IEC-60439 1069 L.T. Panel Board suitable for operation on 400 V, 3 Phase 50 Hz. A.C. supply in sheet steel enclosure in cubical pattern floor mounting with following fitted on the phase of the panel with bus incomer bar of 400 amps. Capacity, Bus Bar size of 50*10 mm. and neutral of half the capacity and neutral of half the capacity sectionalized through a bus section. The panel shall comprise of the following. 1070 02 No. incoming feeder from two Nos. Transformer with following details:- 1071 02 nos. ACB of 630 amps,50 KA Micro processor type motorised drawout typefor Two seperate Transformers incomer preferably schneider/ABB with indication lamp mechanical on/off indicator. 1072 One set of current transformer of ratio 400/5A 1073 One No. CT operated ammeter 0-400A with ammeter 1074 One No. Voltmeter 0-500 V with voltmeter 1075 One No power factor meter 0.5 lag/ 1-0.5 lead 1076 One No Surge arrestor Relay & One no. UV/OV Relay 1077 One No frequency meter. 1078 Total Nos. of Outgoing feeder as follows- 1079 MCCB of 200 amps,50KA capacity with indication lamp mechanical on/off indicator. -03 nos. 1080 Ammeter with selector switch. 1081 Single phasing preventer. 1082 Sets of timer and relays for overload and underload. 1083 01 Nos. 63 Amps. MCCB for RTU/PLC Panel. 1084 01 Nos. 63 Amps. MCCB as Misc. load 1085 02 Nos. 32 Amps. 4P MCCB for lighting & spare one. 1086 01 No. required 30 KVAr APFC Panel with capacitor bank and feeder SFU & MCCB 63 Amp., 25 KA with APFCrelay in 9 steps & other acceessories to adjust automatically the power factor upto 0.99. 1087 Power and control cables 1088 1100 V grade, 3 core 70mm2 PVC insulated PVC sheathed Aluminium Armoured conductor cablefrom LT panel to motor.(1x3x40 mtr.) 1089 Control cable 1x10C, 1.5 mm2 PVC insulated PVC sheathedCopper conductor cable for moisture sensor Reverse protection thermistor relay etc. 1090 EARTHING 1091 Complete earthing of all the equipments as detailed above shall be done as per IS/IER/PWD specification with G.I Plates, watering pipe and loop earthing with adequate size of G.I/ Al. strip etc. (PS-702) 02 Nos. each of the equipment(3 Nos Pumps + 1 No. LT Panel + 1 No. PLC Panel.) size of earthing plate 600mm x 600mm x6 mmwith salt and coal. 1092 Lighting system: 1093 Supply & erection of M.S. Tubular Poles SP-36, 9.5 M height. 1094 S/F of 72 watt LED with lumen reflector. 1095 Feeder pillar for lighting 1096 Supply and laying of 4x16mm2 Al. armoured cable. 1097 Internal electrification with fixtures. 1098 S/F 1200 mm ceilingFan for LT Room 1099 S/F of exhaust Fan for LT Room, VCB room. 1100 Earthing of street light pole (SOR-41) 1101 Painting of street light (P5-634) 1102 Supply and installation of DCP type of 5 Kg. Fire existinguisher(PS-1132) 1103 12 mm thick rubber mating for safe working on. 1104 Tools 1105 Hydrulic crimping tools-Crimping range: 16-300 sq.mm.,Weight: 6 Kg. ,Length: 500mm,Make/ Model:YQK300 1106 Mannual crimping tools-Crimping range: 400 sq.mm.,Make/ Model: Crimp well 1107 Tong tester (AC/DC-1000A, make-Rishabh)Multimeter (AC/DC-1000A,make-Meco)Megger (AC/DC-500V make-Rishabh)Screwdriver (6"x 12", make- Taparia)Plier (250mm, make-Taparia) 1108 Chain wrench (12"x18", make Taparia) Pipe wrench (1200mm, make Taparia) 1109 Installation of above equipments ,Pumsets and Panels etc. complete. 1110 Testing of pumping plantand Panels etc. complete at works 1111 Commissioning of pumping plantsand Panels etc. complete 1112 Chequered plate of required size so as to cover all trenches. 1113 Power Distribution Transformer : 1114 Supply of Oil immersedOutdoor type Power distribution transformer 11/0.433 KV rating 200 KVA double wound with copperwinding, Level-1, vector group dyn 11, ONAN with manually operated ± 5.0 % off load tap changer in step of 2.5% and complete with standard fitting & accessories. 1115 Supply and laying of 1100 voltage grade ,1Rx3.5Cx 185 mm2 Aluminium conductor, XLPE armoured cable from Transformers to LT Panel. 1116 Double Earthing of Transformers consisting of 04 nos. Earthing Pit (two for each neutral and body) with Al/GI. strip size 25X6mm, the minimum distance between to earthing pits, Double Earthing works and all electrical equipments shall be as per IS and IER. 1117 Installation , testing and Commissioning of Transformer complete. 1118 H.T. Switch Gear Panel : 1119 Supply of 12 KV,H.T. V.C.B. Panel with one incoming & two out going ,630 Amp. (25 KA) Rating have followings- 1120 Incommer Feeder- 01 No. 1121 3 O/C + 1 EF IDMT Characteristics Relays based Incommer control panel equiped with over current & earth fault relay with core balance C.T., master trip relay, instantaneous under voltage realy & Auxilliary realy etc.C.T.ratio 30-20/5A Dual core, Class-1 for measurement core & 5P10 for protection core & PT 11KV/110 VAC. KWH meter, power factor meter, frequency meter. Amp. meter 0-20& volt meter 0 to12 KV. All relays required separately conventioal type 24 to 30 VDC, 110 VAC. 1122 Outgoing Feeder- 02 Nos. 1123 outgoing feeder control panel equiped withtriple pole 2 O/C + 1 E/F relay with IDMT & intantaneous characterisstics, mater trip relay & Auxilliary relay for Buchhloz alarm / trip, OTI alram / trip & WTI alram/trip, etc.C.T.ratio 30-15/5A, Class-1 for measurement core & 5P10 for protection core. 1124 DC Supply 1125 SICT battery bank, exide make, consisting of 16 cells, 2 volt each for supply VDC 24 to 30 Volt with battery charger of approved make with suitable M.S. Stand / Trolley, equipment fittings with accessories etc. 1126 Supply and laying of 1x3Cx95 mm 2 ,11 KV HT Al. XLPE cable from metering panel to H.T. Panel and form H.T. Panel to both transformers. 1127 S/F of XLPE cable End termination box 1128 Indoor end termination box. 1129 Earthing ofH.T Panel as per IS & IER. 1130 Testing & Commissioning of HT Panel etc. 1131 Erection of All sub staion equipments and fencing with iron mesh etc. complete in all respect. 1132 Commissioning of All sub station equipments etc. complete in all respect. 1133 OTHER REQUIRED ITEMS 1134 CE/UL approved manufacturer"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. 1135 Auto phase reversal unit -Auto phase reversal unit/ automatic transfer switch withinbuilt time delay & enclosure of SuitableAmpere rating (Confirming to IEC: 60947-1 and IEC: 60947-b-1)as specified in tender technical specification sheet.250amp 1136 CE / UL approved manufacturer’s Radartype Level Transmitter for CWR as specified in tender technical specification sheet 1137 CE / UL approved manufacturer’s Pressure Transmitterin main header line of Pump as per specifications specified in tender technical specification sheet. 1138 CE & UL certified Surge protector for control panel 1139 CE & UL certified pressure transmitter for each pump 1140 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each ZPS/ OHTto store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. 1141 G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. 1142 CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. 1143 Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) 1144 Complete cabling for ZPS including all power and control cable of all equipments at ZPS 1145 Security Surveillance IP Camera with Recorer 1146 Installation, commissioning & testing for CWR 1147 All SCADA SYSTEM ON TW ZONE 3B& 3C 1148 S.I.T.C OF SCADA SYSTEM ONTUBEWELL AT ZONE 3B 1149 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. 1150 G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. 1151 Installation, commissioning & testing for tubewell 1152 Trial run for three month period for tubewell 1153 NEW TUBEWELL AT ZONE-3B T.W.-1 & 2 1154 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. 1155 G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. 1156 Installation, commissioning & testing for tubewell 1157 Trial run for three month period for tubewell 1158 S.I.T.C OF SCADA SYSTEM ONTUBEWELL AT ZONE 3 C TW-1 (CWR CAMPUS) & 2, 3 , 4 1159 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. 1160 G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. 1161 Installation, commissioning & testing for tubewell 1162 Trial run for three month period for tubewell 1163 COST OF INTEGRATION 1164 Cost of integration of Tubewells, OHT & CWR with MCS/ LCS 1165 All SCADA SYSTEM ON OHT ZONE 3B& 3C 1166 S.I.T.C OF SCADA SYSTEM FOR EXISTING OVERHEAD TANK 2250 KL AT (ZONE 3B) 1167 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations 1168 G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges . 1169 Renovation / Restoration of SCADA at existing OHT 1170 S.I.T.C OF SCADA SYSTEM FOR NEW OVERHEAD TANK AT 2200 KL (ZONE 3C) 1171 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations 1172 G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges . 1173 03 MONTH TRIAL & RUN OF PUMPING PLANT OF TUBEWELL FOR ZONE 3B 1174 03 Month trial & run of Pumping Plant for 01 Nos. existing tubewell & 02 nos. new tubewells including liquid Chlorine, Operating Staff. Excluding Electricity Charges. 1175 03 MONTH TRIAL & RUN OF PUMPING PLANT OF TUBEWELL FOR ZONE 3C 1176 03 Month trial & run of Pumping Plant for 03 Nos. new tubewells including Operating Staff. Excluding Electricity Charges. 1177 03 MONTH TRIAL & RUN OF PUMPING PLANT OF CLEAR WATER RESERVIOR. 1178 03 Month trial & run of Pumping Plant for 01 No. CWR including liquid Chlorine & 01 no. new tubewell, Operating Staff. Excluding Electricity Charges. 1179 PART - D (Nagar Palika Parisad Bulandshahr Reorganization Scheme Zone 5) 1180 CIVIL WORK 1181 Construction ofRCC Overhead Tank of 1900 KL Capacity at 20 m Staging from made up level (Made Up Level of OHT will be taken as 0.70 m above from newrby existing approach road level) in M-30 grade of concrete. 1182 Submission of design, drawing and supply of all material, labour T&P etc. and construction as per tenderer"s own provided seismic proof design and drawings (approved by the department) complete Intze type tank, on raft or pile cum raft foundation with columns and braces R.C.C. Over Head Tank 1900 KL capacity at 20 m staging from made up level of OHT at site to the top of bottom ring beam of tank. Made up level of OHT will be taken as 0.70 m above from nearby existing approach road level.Earth required for made up level & Brick work required for apron will be arranged by the contractor at his own cost. No extra payment will be paid for this work. The design of the tank shall be based on safe bearing capacity of soil at site as 7 T/m2 and depth of foundation as 3.0 m from existing ground level on pile/raft foundation. If the bearing capacity of soil is found less than 7 T/m2 as per test report, the contractor will submit the design on the B.C. proposed by the NABL approved reputed testing agency. No extra payment will be made for this change. If the B.C. is found more than 7 T/m2 as per testing report than the design of OHT shall be done at B.C 7 T/m2 and depth 3.0m or the depth suggested by testing agency (greater of the two depths). All other details of tank not covered here shall also be as per specifications enclosed. ITEM 1183 & 1184 ARE SOME DETAILS (NOT LIMITED TO) OF WORK WHICH ARE TO BE DONE DURING CONSTRUCTION OF OHT AND THEIR COST IS INCLUDED IN ITEM 1182. (NO EXTRA PAYMENT WILL BE CLAIMED/MADE). 1183 Soil testing Submission of detailed design and drawing including its vetting shall be done from any recognized Government University such as I.I.T./NIT/State Govt./ Centre Govt.institutions / organizations or as per direction of Engineer-in-charge.R.C.C. work will be strictly as per approved design including fixing various pipes and S.S ventilator at the top and fixing of S.S. sheet of 10 mm gauge manhole cover of 60 cm x 60 cm size with frame and locking arrangement and railing including supply of all material complete in all respect. Water bar"s / water stoppers of 18mm gauge and 30 cm wide (15cm below the joint and 15cm above the joint) along the joint of cylindrical wall of over head tank at every lift / joint should be provided.Supply and fixing of S.S. ladder, inside the tank body from roof to the bottom dome of the tank in a slope of 3: 1 (3 vertical: 1 horizontal) with railing as specified.Railing on double column staircase & its landings, all around balcony & top dome for access up to ventilator as per specifications including supply of all material. Railing shall be provided in three rows of G.I. pipe (medium) 20mm dia. (min.). Box type enclosure at the entrance of the staircase upto first landing having locking arrangement should be provided.Supply and fixing of digital water level indicator along with all necessary equipments such as inverter etc. as per specifications and fixing of lightening arrestor, conductor and earth plate etc. as per specifications. 1184 Supply of all materials and construction of 100 mm thick R.C.C. floor apron and 15 cm dia. semi circular drain around apron in a slope towards wash out chamber with glass strips, with base concrete 1:3:6 with stone ballast of thickness 150mm.Three coats of approved quality and shade of Apex ultima Paintas per direction of Engineer-in-charge over concrete work including supply of all materials etc. Three coats of anti corrosive / aluminum / black Japan paint of approved quality on all iron work including supply of all material, labour and T&P etc complete in all respect.Supplying and fixing of all required sizes C.I. D/F sluice valves kirloskar make , RCC overflow chamber & Sluice Valve Chamber as per relevant latest I.S. specifications at below ground level or as per direction of E/I including supply of all jointing and other make materials such as rubber insertion sheet, nut bolts, washer etc, complete as per Specifications.Supply and fixing of following pipes:-400 mm dia in inlet;DMA 1- 400 mm dia in outlet; DMA 2- 400 mm dia in outletDMA 3- 250 mm dia in outlet, 100 mm dia in wash out.The words U.P. Jal Nigam (Urban), year of construction, capacity of O.H.T. with staging and slogan approved by Engineer in charge shall be painted prominently in Block Letters not less than 30 cm in height.Testing of tank for water tightness as per specifications enclosed/ as per CPHEEO Manual including supply of water. Trial & Run of 3 months, maintenance of work ( till handing over or date of shedule complision whichever is later) and defect liability period of 12 months after handing over to NagarPalika Parishad Bulandshahr. including supply of all materials, labour, T&P etc. complete in all respect. 1185 Construction of pump house, chlorinating room,MCS room, Boundary Wall with gate and approach road works 1186 Supply of all materials and construction of pump house of size (3.6 m x 3.0 m x 3.0 m) cum chlorinating room size (1.80mx 2.60 m x 3.00 m) . (As per type design of UPJN (Urban). 1187 Construction of Stilling chamber (1.50 m x 1.50 m x 1.00 m) and V Noch for bye-pass Arrangement of Tubewells complete in all respect as per direction of Engineer in Charge. 1188 Construction of MCS at NPP Bulandshahr centralized control room including supply of all materials, labour, T&P etc. complete in all respect as per direction of Engineer in Charge. 1189 Construction of boundary wall around water works compound.(As per type design of UPJN (Urban)). 1190 Supply and fixing 3.6M & 1.20M wide MS Gate with pillers including fabrication and supply of steel and construction of boundary pillars etc. complete for pump house complete in all respect as per direction of Engineer in Charge. 1191 Supply & laying of 80mm cement interlocking tiles for approach road including supply of all materials, labour, T&P etc. complete in all respect as per direction of Engineer in Charge. 1192 Recharge unit (RWH) of ground water by rooftop rainwater of pump house and water available of byepass arrangement of tubewell and washout as per drawing including supply of all material T&P to the satisfaction of E-In-Charge. 1193 Laying of Rising Main pipe line & appurtenent works 1194 Excavation of earth in ordinary soil (loam, clay or sand) for laying of pipe line including refilling, ramming, dressing, leveling of trenches in 30 cm layers anddisposal of surplus earth for different size of pipe lift up to 1.5m and 500 m awayas per direction of Engineer in Charge . If any Utilities are damaged during excavation (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work 1195 Supply of D.I. pipe line into trenches true to alignment & agradient including Supply of D.I. D/F specials, F.O.R. destination and all taxes and insurance etc. cost of all labour, T&P, jointing, materials,specials, testing of pipe line etc. complete 1196 D.I. pipe Class-K-9 1197 200 mm dia 1198 Carting laying & jointing of D.I. pipe line into trenches true to alignment & agradient including cost of all labour, T&P, jointing, materials,specials, testing of pipe line etc. complete.If any Utilities are damaged during carting or laying or jointing (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work 1199 D.I. pipe Class-K-9 1200 200 mm dia 1201 Supply of following size and carting upto site of work, lowering, fixing and jointing of followingfittings in trenches including cost of all materials such as rubber packing, nut bolts etc. complete work 1202 C.I.D/F Sluice Valve IS 780-1984 1203 200 mm dia 1204 THRUST BLOCK 1205 Provision forR.C.C. Thrust Block with cement, coarse sand & 20 mm gauge stone ballast in proportion of 1:1.5:3 in pipe line including supply of reinforcement and its fixing and binding the same with 0.50 mm thick binding wire on position and necessary centering & shuttering complete for proper completion of work including supply of steel and wastage etc. 1206 Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. 1207 Cement Concrete Road 1208 Bituminous Road 1209 Interlocking Road 1210 Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. 1211 Cement concrete Road (100mm thickness of 1:2:4 cement concrete over base of 100mm thickness of 1:4:8 Lean concrete) 1212 Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) 1213 Interlocking Road (Using 60% old tiles including spreading of local sand and base concrete in 1:6:12 ,10 cm thickness) 1214 Sluice Valve Chamber (Masonary Type) 1215 Laying of Distribution pipe line & other appurtenent works 1216 Excavation of earth in ordinary soil (loam, clay or sand) for laying of pipe line including refilling, ramming, dressing, leveling of trenches in 30 cm layers anddisposal of surplus earth for different size of pipe lift up to 1.5m and 500 m awayas per direction of Engineer in Charge . If any Utilities are damaged during excavation (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work 1217 Supply of following size of pipes including all types of specials, railways frieght and cartage up to store , all taxes and duties complete as per direction of Engineer-in-charge. 1218 HDPE Pipe (PE-100) 1219 110 mm dia 1220 140 mm dia 1221 160 mm dia 1222 DI Pipe Class K-7 1223 200 mm dia 1224 250 mm dia 1225 300 mm dia 1226 400 mm dia 1227 Carting ,laying and jointing of the following sizes of pipes into the trenches includingall types of specials, cost of all jointing materials,making interconnection & specials, labour and T & P , testing etc. completeas per direction of Engineer-in-charge.If any Utilities are damaged during carting or laying or jointing (such as telephone cables, electric cables, gas pipelines, sewer house connections, water house connectionetc.), it will be repaired by the contractor at his own cost.No extra payment will be paid for this work 1228 HDPE Pipe (PE-100) 1229 110 mm dia 1230 140 mm dia 1231 160 mm dia 1232 DI Pipe Class K-7 1233 200 mm dia 1234 250 mm dia 1235 300 mm dia 1236 400 mm dia 1237 Supply and fixing & carting of following types of fittings including railway frieght, cartage up to site, all taxes and duties etc. complete. 1238 (A) C. I. Sluice Valveas per latest IS specifications 1239 100 mm dia 1240 125 mm dia 1241 150 mm dia 1242 200 mm dia 1243 250 mm dia 1244 Scour Valve 80 mm dia 1245 Air Valve 20 mm dia 1246 Fire Hydrants 80 mm dia 1247 Supply of all materials, labour, T&P for construction of following types of chambers as per departmental drawing & design. 1248 Sluice Valve Chamber (Masonary Type) 1249 Sluice Valve Chamber (Surface Box Type) 1250 Fire Hydrant Chambers 1251 Air Valve Chambers 1252 Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. 1253 B.O.E. 1254 C.C. Interlocking Tiles Road 1255 C.C. Road 1256 Bituminous Road 1257 Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. 1258 B.O.E Road (60% old and 40% new Bricks) 1259 Laying of 80mm thick C.C. Interlocking Tiles Road with 40% new Tiles including dressing surface and including supply of tile,including all labour T&P etc. required for proper completion of work. 1260 CC Road (100mm thickness of1:2:4 cement concrete ) 1261 Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) 1262 Provision for crossings of nalas & culvert including shifting of telephone cables etc. along the alignment of pipeline including supply of C.I. tyton pipe andspecials etc. complete in all respect as per direction of Engineer in Charge. 1263 (100 -40mm dia) upto 3.0 M 1264 (90-100mm dia) upto 3.0 M 1265 Making New Water House Connection with Distribution main including Dismantling & permanent reinstatement in all types of road , supply , carting of specials lowering them into trenches, fixing them including bailing out of water necessary excavation for connection including all labour , T&P etc. required for proper completion of the works as per direction of engineer - in- Charge. 1266 For 90 mm to 500mm dia (HDPE Pipe/DI) 1267 Dismantling of following types of road surface for laying of pipe line Including sorting out of serviceable material and disposal of unserviceable material up to 50 m. 1268 B.O.E. 1269 C.C. Interlocking Tiles Road 1270 C.C. Road 1271 Bituminous Road 1272 Permanent reinstatement of following types of road surface for laying of pipe line Including supply of all material, labour, T&P etc. complete in the direction of engineer incharge. 1273 B.O.E Road (60% old and 40% new Bricks) 1274 Laying of 80mm thick C.C. Interlocking Tiles Road with 40% new Tiles including dressing surface and including supply of tile,including all labour T&P etc. required for proper completion of work. 1275 Cement Concrete Road (100mm thickness of1:2:4 cement concrete over base of 100mm thickness of 1:4:8 Lean concrete) 1276 Bituminous Road (as per UPPWD specifications , i.e. 10cm thickness of granular sub-base, 12.5cm thickness of wet mix macadam (WMM), primer coat with SS-1 bitumen emulsion, tack coat with bitumen VG-10 and laying bituminous concrete of 45mm thickness.) 1277 Maintenance works 1278 Repairing of OHT 2200KL/22 M staging due to seepage in bottom dome, conewall & vertical wall after chiseling the loose concerete and ensuring water tightness of the OHT & repairing of 200 mm to 500 dia sluice valveincluding Scrapping and chiseling of plaster, providing and applying one coat of slurry of hydrophilic in nature for waterproofing treatment from the internal surface of Over Head Tank, required thickness plaster with chemical coding, supply and fixing of scaffolding, painting, colour washing, with Asian Apex Paint, stacking/proper disposal of dismantled plaster material, repairing of staircase including supply and fixing of GI pipe hand rail, vertical post and also repairing of minor defect in landing, riser and tread, Supply & fixing of Proper ventilator at top dome in circular shape along with an R.C.C. cover of minimum 1.50m dia and 7.5 cm thickness, pillar of ventilator should be minimum 50 cm dia., Lightening conductor as per I.S.S.2309 of its latest amendments of latest electricity rules, C.I. manhole of min 60x60cm size made of M.S.channel & Painting of all concrete surface and steel pipe works with all labour, material T&P complete in all respect as per direction of Engineer in Charge. 1279 Repairs of boundary wall Supply all materials, labour, T&P etc. Required for proper completion of work complete in all respect as per direction of Engineer in Charge. 1280 Interconnection in existing distribution main with supply of all materials,specials,labour,t7p including dismantling and reinstatement of all types of road ect complete in all respect. 1281 E & M work 1282 Construction of Tubewell for Zone - 5A & 5B 1283 Drilling of borehole for Tubewell contruction by RC Rig Machine including transportation, erection, dismantling of Rig and assoiated T & P complete in all respect including required all material, labour etc. 1284 Transportation, Erection and Dismantling of Rig Machine 1285 Drilling of 600mm size bore from GL to 60 BGL 1286 Drilling of 500mm size bore from 1287 (i) 60M BGL to 100MBGL 1288 (ii) 100M BGL to 150MBGL 1289 Tubewell Assembly 1290 M.S. tubewell assembly with all required parts like plain pipe, slotted pipe (as required upto 50% of plain pipes) rings, well cap, bail plug, clamp, reducer, central guide, support structer etc. As required & as per typed design complete in all respect. 1291 300 mm. Dia MS ERW Housing/ casing pipe having wall thickness of 7.1mm. 1292 200 mm. Dia MS ERW slotted/ casing pipe having wall thickness of 7.1mm. 1293 Supply of pea gravel 1294 Logging of bore hole by departmental / approved electric logger. 1295 Lowering of Tube well assembly duly welded including welding electrode and shurounding of pea gravel complete in all respect. 1296 Lowering of 300mm dia pipe from GL to 54m deep BGL. 1297 Lowering of 200mm dia pipe from 54 to 100m deep BGL. 1298 Lowering of 200mm dia pipe from 100 to 135m deep BGL. 1299 Development of Tubewell by compressor 1300 Transportation, Installation and Dismantling of 250 PSI Compressor 1301 Development of Tubewell by 250 PSI Capacity Air compressor 1302 Development of Tubewell by O.P. Unit 1303 Transportation, Installation and Dismantling of 3 Cusec O.P. Unit & Yield Test. 1304 Development of Tubewell by 3 Cusec Capacity by O.P. Unit 1305 Chemical and Bacterological test of water sample from depaprtmental/ approved lab. 1306 PUMPING PLANT OVER A EXISTING TUBEWELL AT ZONE-5A, T.W.-1 (CHANDPUR TW NO. 24 OHT CAMPUS) & T.W.-2 (NEAR FCI GODOWN TW NO. 27) 1307 SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1300 LPM, 55m head, 25 HP orsuitable capacity. 1308 Soft starter with RS-485 port-400V Class22 Kw rating or above as per site requirement. 1309 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. 1310 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 1311 Replacement of damaged control and power wiring at tubewell of all equipment at pump house. 1312 SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steady state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. 1313 SITC of 03 Phase Servo Voltage Stabilizer 40 KVA. 1314 Dismantling of existing pumping plant 1315 Repairing & overholing of actuator including all labour etc complete. 1316 PUMPING PLANT OVER A NEW TUBEWELL AT ZONE 5A, T.W.-1 1317 SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1300 LPM, 55m head, 25 HP orsuitable capacity. 1318 Soft starter with RS-485 port-400V Class22 Kw rating or above as per site requirement. 1319 01 KVAR UPS at TW Panel 1320 150 mm size motor operated actuator with Sluice valve 1321 Capacitor Bank 10 KVAR with Relay 1322 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. 1323 CE/UL approved manufacturer"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. 1324 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 1325 CE & UL certified Electromagnatic Flowmeter suitable for above line size 150 mm. 1326 CE & UL certified pressure transmitter 1327 SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steady state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. 1328 CE & UL certified Surge protector for above control panel 1329 Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) 1330 Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . 1331 Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. 1332 Supply & Laying of PVC insulated Al. armoured cable size 1x3.5/4Cx35 sq mm. from transformer LV side to meter panel and meter panel to starter. 1333 SITC of 03 Phase Servo Voltage Stabilizer 40 KVA. 1334 PUMPING PLANT OVER A EXISTING TUBEWELL AT ZONE 5B, T.W.-1 (AMBA ENCLAVE) 1335 SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1400 LPM, 53m head, 30 HP orsuitable capacity. 1336 Soft starter with RS-485 port-400V Class22 Kw rating or above as per site requirement. 1337 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. 1338 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 1339 Replacement of damaged control and power wiring at tubewell of all equipment at pump house. 1340 SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steady state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. 1341 SITC of 03 Phase Servo Voltage Stabilizer 50 KVA. 1342 Dismantling of existing pumping plant 1343 Repairing & overholing of actuator including all labour etc complete. 1344 PUMPING PLANT OVER A EXISTING TUBEWELL AT ZONE 5B, T.W.-2 MANSAROVAR COLONY (TW CONSTRUCTED BY NAGAR PALIKA PARISHAD BSR) 1345 SITC of Submersible Pumping Plant with 24m column pipe assembly, NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1400 LPM, 53m head, 30 HP orsuitable capacity. 1346 Soft starter with RS-485 port-400V Class22 Kw rating or above as per site requirement. 1347 01 KVAR UPS at TW Panel 1348 150 mm size motor operated actuator with Sluice valve 1349 Capacitor Bank 10 KVAR with Relay 1350 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. 1351 CE/UL approved manufacturer"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. 1352 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 1353 CE & UL certified Electromagnatic Flowmeter suitable for above line size 150 mm. 1354 CE & UL certified pressure transmitter 1355 SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steady state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. 1356 CE & UL certified Surge protector for above control panel 1357 Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) 1358 Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . 1359 Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. 1360 Supply & Laying of PVC insulated Al. armoured cable size 1x3.5/4Cx35 sq mm. from transformer LV side to meter panel and meter panel to starter. 1361 SITC of 03 Phase Servo Voltage Stabilizer 50 KVA. 1362 PUMPING PLANT OVER A NEW TUBEWELL AT ZONE-5B, T.W.-1 (PROPOSED OHT CAMPUS) 1363 SITC of Submersible Pumping Plant with 24m column pipe assembly,NRV,bend,Tee, D/F pipe, earthing, painting, Toolset, power wiring of pump house internal and external chain pulley block and all pumping plant accesssories with nut bolt ,rubber packing etc 1500 LPM, 53m head, 30 HP orsuitable capacity. 1364 Soft starter with RS-485 port-400V Class22 Kw rating or above as per site requirement. 1365 01 KVAR UPS at TW Panel 1366 150 mm size motor operated actuator with Sluice valve 1367 Capacitor Bank 10 KVAR with Relay 1368 3 Mtr. long heavy duty size 150mm diacolumn pipe same as above. 1369 CE/UL approved manufacturer"s Intelligent smart energy meter with memory real time clock and 1 serial port integrated with R.T.U. 1370 CE & UL certified Hydrostatic type sub soil water level transmitter for tubewell. 1371 CE & UL certified Electromagnatic Flowmeter suitable for above line size 150 mm. 1372 CE & UL certified pressure transmitter 1373 SITC of Automatic type chlorinating plant solenoid driven dosing pump of capacity 0-6 LPH ( pressure 4kg/cm2 with ORP sensor to check and regulate the dosing along with 200 ltr capacity HDPE tank (02 nos., 1W+1S) ,standard fittings, wall/floor mountings MS bracket for dosing pump with GM Valve ,cock valve & sodium hydro chloride solution.,chlorine test kit with O.T. Solution complete with all respect.( suitable for 100-220V and 30-60 Hz , suction lift- 1.5 m., injection pressure 4 bars, steady state accuracy +-3% repeatability +-3%) with RS 485 Port O/P having facility of interface with PLC SCADA system. 1374 CE & UL certified Surge protector for above control panel 1375 Auto Phase reversal unit with inbuilt time delay and enclosure (100 Amp.) 1376 Complete cabling of tubewell including all power and control cables of all equipment at pump house and OHT . 1377 Copper cable size 2x3cx6 sq mm. flat for 18 m extra column pipe. 1378 Supply & Laying of PVC insulated Al. armoured cable size 1x3.5/4Cx35 sq mm. from transformer LV side to meter panel and meter panel to starter. 1379 SITC of 03 Phase Servo Voltage Stabilizer 50 KVA. 1380 ELECTRICAL / MECHANICAL WORKFOR EXISTING OVERHEAD TANK 2200 KL (ZONE 5A) 1381 Repairing and Overhauling of Motor operated Actuators with Sluice valve of size 300 mm. at distribution line with all required material complete in all respect at DMA-1 1382 Repairing and Overhauling of CE & UL certified Electomagnetic Flowmeter for OHT line size 300 mm. dia. with all required material complete in all respect at DMA-1 1383 Motor operated Actuators with Sluice valve of size 300 mm. at distribution line with all required material complete in all respect at DMA-2 1384 CE & UL certified Electomagnetic Flowmeter for OHT line size 300 mm. dia. with all required material complete in all respect at DMA-2 1385 Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system too including PH compensator. 1386 CE/UL Certified suitable capacity UPS with batteries . 1387 ELECTRICAL / MECHANICAL WORK FOR NEW OVERHEAD TANK 1900 KL (ZONE 5B) 1388 Motor operated Actuators with Sluice valve of size 400 mm. at distribution lineat DMA-1 1389 CE & UL certified Electomagnetic Flowmeter for OHT line size 400 mm. dia at DMA-1 1390 Motor operated Actuators with Sluice valve of size 400 mm. at distribution line at DMA-2 1391 CE & UL certified Electomagnetic Flowmeter for OHT line size 400 mm. dia at DMA-2 1392 Motor operated Actuators with Sluice valve of size 250 mm. at distribution line at DMA-3 1393 CE & UL certified Electomagnetic Flowmeter for OHT line size 250 mm. dia at DMA-3 1394 Chlorine Analyzer with MODBUS RTU having following specifications- (a) FRC Sensor (Senssit make), range- 0-5 PPM (electrolyte with membrane cap), tytpe-Amperometric. (b) Analyzer with RS 485O/P. suitable to OHT distribution line size & compatible with SCADA system too including PH compensator. 1395 CE/UL Certified suitable capacity UPS with batteries . 1396 SITC OF SCADA SYSTEM FOR ZONE- 5A EXISTING T.W.-1 (CHANDPUR TW NO. 24 OHT CAMPUS) & T.W.-2 (NEAR FCI GODOWN TW NO. 27) 1397 Repairing & overhauling of all existing scada automation related equipement including restoration of existing RTU / PLC panel with all required material coplete in all respect. 1398 ZONE- 5A NEW TW NO. 1 1399 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. 1400 G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. 1401 CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. 1402 Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) 1403 Installation, commissioning & testing for tubewell 1404 Trial run for three month period for tubewell 1405 SITC OF SCADA SYSTEM FOR ZONE- 5B EXISTING T.W.-1 (AMBA ENCLAVE) 1406 Repairing & overhauling of all existing scada automation related equipement including restoration of existing RTU / PLC panel with all required material coplete in all respect. 1407 ZONE- 5B EXISTING T.W.-2 MANSAROVAR COLONY (TW CONSTRUCTED BY NAGAR PALIKA PARISHAD BSR) 1408 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. 1409 G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. 1410 CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. 1411 Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) 1412 Installation, commissioning & testing for tubewell 1413 Trial run for three month period for tubewell 1414 ZONE- 5B NEW TUBEWELL No. 1 (PROPOSED OHT CAMPUS) 1415 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations. 1416 G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges. 1417 CE & UL certified 7" HMI touch screen suitable to communication with PLC/RTU local display and control of process parameter. 1418 Control panel with IP-54 protection industrial grade for all equipment separate for control (24V and power equipments) 1419 Installation, commissioning & testing for tubewell 1420 Trial run for three month period for tubewell 1421 COST OF INTEGRATION 1422 Cost of integration of Tubewells and OHT with MCS/ LCS 1423 S.I.T.C OF SCADA SYSTEM FOR EXISTING OVERHEAD TANKAT (ZONE 5A) 1424 G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges . 1425 Renovation / Restoration of SCADA at existing OHT 1426 CE & UL certified Radar type level transmitter for OHT 1427 S.I.T.C OF SCADA SYSTEM FOR NEW OVERHEAD TANKAT (ZONE 5B) 1428 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each tubewell/ OHT & stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations 1429 G.S.M./G.P.R.S. based wireless communication with 5G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant internet charges . 1430 CE & UL certified Radar type level transmitter for OHT 1431 03 MONTH TRAIL & RUN OF PUMPING PLANT (Zone 5A & 5B) 1432 03 Month trail & run of Pumping Plant for 06 Nos. tubewell including liquid Chlorine, Operating Staff. Excluding Electricity Charges
|