Supply And Installation Of Construction Plate With Galvanized Sheet And Wooden Structure. Af_03/2022_, Shed For Warehouse Area, Water Network With Standard Water Inlet Dia. 3/4, Conf. Spec. Cesan, Inc. Pair Pipes And Connections, Manual Excavation Of A Trench With A Depth Of Less Than Or Equal To 1.30M, Preparation Of The Bottom Of A Trench With A Width Of Less Than 1.5 M Adjustment Of The Natural Soil Af 082020, Piled Backfill Of Foundation Pits,, Lean Concrete For Ballast, Trace 1:4, 5:4, 5 (In Dry Mass Of Cement/Medium Sand/Gravel 1) - Prepare, Pillar Or Beam Frame Of Conventional Reinforced Concrete Structure Using 5.0 Mm Ca-60 Steel, Pillar Or Beam Frame Of Conventional Reinforced Concrete Structure Using Ca-50 Steel 8, Pillar Or Beam Frame Of Conventional Reinforced Concrete Structure Using 10.0 M Ca-50 Steel, Assembly And Disassembly Of Formwork For Rectangular Pillars And Similar Structures, Simple Right Foot, Concrete Fck = 25Mpa, Ratio 1:2, 3:2, 7 (In Dry Mass Of Cement/Medium Sand/Gravel 1) - Preparation Mec, Landfill Manual Of Trenches With Sand For Backfilling And Mechanized Compaction Af 052016, Masonry Sealing Of Hollow Concrete Blocks Of 14X19x39 Cm (Thickness 14 Cm) And Mortar Of A, Masonry Of Structural Concrete Blocks Of 14X19x39 Cm (Thickness 14 Cm), Fbk = 14 Mpa, Using C, Unidirectional Precast Slab, Bi-Supported, For Lining, Filling In Ceramics, Conventional Joist, Demolition Of Perforated Block Masonry, Manually, Without Reuse, Sealing Masonry, Plating Applied To Masonry And Internal Concrete Structures, Using A Trowel. Mortar, Plaster, For Receiving Ceramics, In Mortar Mix 1:2:8, Manual Preparation, Applied Manually, Single Mass, For Receiving Paint, Ceramic Coating For Internal Walls With Extra Enamelled Plates Measuring 33X45 Cm Ap, Ballast Of Lean Concrete Applied To Floors Slabs On Ground Or Radie, Thick 5 Cm, Subfloor In 1:4 Mortar Mix (Cement And Sand), Mechanical Preparation With 400 L Concrete Mixer, Applied, Ceramic Coating, Composite Wood Weave, Roofing With Tiles, Steel Sheet Flashing, 20 Mpa Concrete Floor, Cold Water Point - Washbasin, Tank, Kitchen Sink, Etc., Point With Pressure Record - Shower, Flush Box, Point For Primary Sewage - Toilet, Point For Secondary Sewage, Point For Siphon Box, Pvc Tube, Normal Series, Tube, Pvc, Weldable, Weldable Dn 32Mm, Dn 50Mm, Raw Drawer Register, Register Of Raw Pressure, Brass, Polyethylene Water Tank, 500 Liters, Siphon Toilet, Oval Embedded Basin In White Ceramics, Polished Gray Granite Countertop, Chrome Table Tap, Flexible Type Siphon, Circular Septic Tank, Circular Anaerobic Filter, Circular Sink, Easel Kit For Water Measurement, Plastic Tap 3/ 4, Removing Electrical Cables, Removing Light Fixtures, Led Reflector 400W, Electrical Lighting Point, Track Type Luminaire, Electrical Socket Point, Electrical Socket Point For Pump, Insulated Flexible Copper Cable, 1.5 Mm², 2.4 Mm², 6 Mm², 10 Mm², Din Type Monopolar Circuit Breaker, Din Type Bipolar Circuit Breaker, Current, Rated Current 16A, Din Type Three-Pole Circuit Breaker, 50A Rated Current, Reinforced Corrugated Flexible Conduit, Corrugated Flexible Conduit, Dn 20 Mm, Dn 25 Mm, Dn 25 Mm (3/4), Threadable Rigid Conduit, Dn 32 Mm (1), Dn 60 Mm (2), Steel Sheet Power Distribution Frame, General Measuring Frame
|