Tender For Provision Of Central Mi Room In Sector A Under Ge N Patiala; 1 Lump sum price worked out by the tenderer for“BUILDING/ STRUCTURE WORKS" as listed in Schedule ‘A’ Section - I 2 Lump sum price worked out by the tenderer for“INTERNAL ELECTRIFICATION WORKS" as listed in Schedule ‘A’ Section - II (Part-I) 3 Sch "A" Sec - II (Part-II), (INTERNAL ELECTRIFICATION WORKS) 4 Point wiring (using approved colour coding as per IS)with 1100 volts grade, stranded copper conductor 1.5 Sqmm (nominal area), FRLSH, PVC insulated and unsheathed cable IS 694 marked TEC and FIA approved and includingPVC concealed conduit (thickness not less than 1.5mm and 20 m dia) and its fittings ISI marked PVC junction boxes terminated in sunken/pressed metal flush box for mounting of modular switches/sockets/fan regulators and white cover plate with frame, also including FRLSHPVC insulated unsheathed stranded copper conductor 1.5 Sqmm (nominal area)1100 volts grade, copper conductor cable as earth continuity conductor to common earth and connected to earth dolly including necessary cutting/chases complete all as specified and directed by Engineer-in-Charge for One light point controlled by one switch or one (Ceiling/ Wall/ Exhaust) fan point controlled by one switch and regulator and one bell pointcontrolled by one bell push(Switches and regulators shall be measured and paid for separately.) (Wiring shall be done as per colour code in IS for phase, neutral and earth)Note :Eye/bottle thimbles shall be used for connection in switches/sockets & MCB"s in DB"s without any extra cost. 5 All as per Item No. 4.00 here in before but for One three pins 5 Amps switch socket outlet point on independent board etc complete all as specified and as directed by Engineer-in-charge. 6 All as per Item No. 4.00 here in before but for One three pins 5 Amps switch socket outlet point on same board with other switches etc complete all as specified and as directed by Engineer-in-charge. 7 Point wiring (using approved colour coding as per IS)with 1100 volts grade, stranded copper conductor 2.5 Sqmm (nominal area), FRLSH, PVC insulated and unsheathed cable IS 694 marked TEC and FIA approved and includingPVC concealed conduit (thickness not less than 1.5mm and 20 m dia) and its fittings ISI marked PVC junction boxes terminated in sunken/pressed metal flush box for mounting of modular switches/sockets and white cover plate with frame, also including FRLSHPVC insulated unsheathed stranded copper conductor 2.5 Sqmm (nominal area)1100 volts grade, copper conductor cable as earth continuity conductor to common earth and connected to earth dolly including necessary cutting/chases complete all as specified and directed by Engineer-in-Charge for 16 Amp socket outlet (Wiring shall be done as per colour code in IS for phase, neutral and earth)Note :Eye/bottle thimbles shall be used for connection in switches/sockets & MCB"s in DB"s without any extra cost. 8 Material & Labour for Concealed Sub main Wiring with two run of 10.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and incl PVC conduit of adequate size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 10.0 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for main DB to Sub DB complete all as specified 9 Material & Labour for Concealed Sub main Wiring with two run of 4.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and incl PVC conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 4.0 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for main DB to AC complete all as specified 10 Material & Labour for Concealed Sub main Wiring with two run of 1.50 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and incl PVC conduit of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.50 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for main DB DB 4 Way for security lights complete all as specified 11 Supply and fix epoxy power coated MCCBdistribution box double door VTPN 4 way vertical type AC 415 V with IP 43 protection for MCBs alongwith provision of MCCB as incomer with common bus-bar at incoming and of outgoing MCBs grouted/ flush to wall, complete all as specified. (Note :- MCCB will be measured and paid under seperate item) (i) Cost of Eye/bottle thimblesused for connection MCBs in DBs shall deemed to be included in unit rate quoted for this items, (ii) Electric wiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth.(iii) connection of the MCCBs/ MCBs with cableshall be made through appropriate size pin/ bottle type thimble properly crimped. all the vacant holes of the DB shall be provided with blank plates of appropriate size. (iv) double continuous earth wire shall be provided for each three phase DB from earthing mains dolly with degree of protection IP 54 & PU gasket a mechnical perfect IK O9 complete all as specified 12 Supply and fix MCCB, 4 Pole, 100 Amp, 25 KA for fixing in DB including proper thimble connection, thermal and magnetic release protectioncomplete all as specified and directed 13 Supply and fix Sheet metal enclosure 12 ways double door for DBs when MCBs areto be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link allflush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed 14 Supply and fix Sheet metal enclosure 4 ways double door for DBs when MCBs areto be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link allflush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed 15 Supply and fix MCB , SPN, 240 Volts ,63 amp for fixing in DBs ofincluding proper thimble connections complete all as specified and directed 16 Supply and fix MCB , SPN, 240 Volts ,32 amp for fixing in DBs ofincluding proper thimble connections complete all as specified and directed 17 Supply and fix MCB, single pole 240 volts 6 to 32 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and directed 18 Supply and fix MCB, single pole 240 volts 40 to 63 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and directed 19 Supply and Fixing ceiling fans complete with blades,hangingrods,with electronic regulator and accessories , 230V, 1200mm sweep without remote, Min air delivery 210 CFM with service value 6.00 BEE 5 Star rated with brushless direct current motor (BLDC) complete all as specified and directed. 20 Supply and fix Exhaust fan AC single phase 230/240V copper wounded of size 300 mm sweep 900 rpm metal body, high efficiency motor, dynamically balanced blade for better performance and corrosion-resistant powder coated metallic finish including Louver ,making holes, grouting nut-bolts complete all as specified and directed 21 Supply and fix LED Lamp LED new Adore 9W E27 Ball Lamp 9watt complete all as specified and directed 22 Supply and fix Energy saving LED lightfitting, 1 x 20 watt,230 volts, Decorative ultra slim linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack. with electronic driver and with best quality diffuser high lumen output, 2.5 KV voltage surge protection, PF 0.98, THD < 10% suitable for surface/pendant mounting complete with all accessoriesincluding and connecting of with twin coreof PVC insulated 0.75 Sqmm copper conductor cable. all as specified & directed. 23 Supply & fixLEDmirror light with Linear & compact 9W mirror light with decorative grey end caps,polycarbonate body and ribbed opal diffuser of capacity 9 watt. all as specified & directed. 24 Supply and fix new generation energy saving and environmental friendly long life LED building security light 1x35 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07,with all accessories including suitable bracket with 32mm bore light grade GI pipe bend to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed. 25 Material & Labour for earthing complete with galvanized steel earth plate electrode 60×60cm×6mm thick electrode burried directly in ground (earth pit notless than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI wire 4 mm diaas earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessaryexcavation & earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1, using 20 mm graded stone aggregate, provn of 40 mm RCC with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade GI pipe for watering, 15 mm dia light grade Gl pipe for lead protection in and including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-I (2009) connected to earthing test point all as specified and indicatedincluding testing on completion including retrieving of old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing as directed by Engineer-in-Charge. NOTE : - (i). Earthing strip GI/copper upto 7.5m will be measured and paid under this item only. (ii). The earth chamber shall be constructed 50 cm away from the edge of earth pit and the cost of the same is deemed to be included in the rate quoted for above item. (ii). Quoted rate is deemed to be inclusive of cost of demolition of old earthing as directed by Engr-in-Charge. (iii). The new earthing so constructed must have resisitance value below 2 ohms. If the aforesaid resistance value is not achieved contractor has to make proper aadditions/alterations to the newly constructed earthing at his own cost. 26 Supply and fixing single pole and neutralenclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, complete all as specified and as directed 27 Supply and fix surface mounted LED luminaire with more light distribution and clutter free ceilings of 20 watt suitable for mouniting on roof.all as specified 28 Subtotal 29 Lump sum price worked out by the tenderer for“INTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - III (Part-I) 30 Sch "A" Sec - III (Part-II),“INTERNAL WATER SUPPLY WORKS 31 Supply and fix over head shower 70mm dia with 235mm long arm both chromium plated fixed for 15mm dia pipe including all fittings as requried complete all as specified 32 Subtotal 33 Lump sum price worked out by the tenderer for“ROAD, PATH & HARD STANDING WORK" as listed in Schedule ‘A’ Section -IV (Part-I) 34 Sch "A" Sec - IV (Part-II),“ROAD, PATH & HARD STANDING WORK" 35 Rolling and consolidation formation suraces with 8 to 12 tonne power roller incl filling in softs spots hollow and depression etc which occurs during rolling for portion coming on cutting/ original ground only to requiredlevel gradient or camber etc including watering before or during rolling complete all as specified and as directed 36 Providing, Laying and compacting 150 mm thick (compacted thickness) Granular Sub Base Course (GSB) Grading as per Grade-II, as per Table 900-1 of MoRTH specifications for Road and Bridge works, 2013 in a single layer over compacted sub grade with natural sand, crushed gravel, crushed stone, crushed slag or combination thereof as per the grading required. The materials are mechanically mixed, spread and leveling on the subgrade by using mortar grader of adequate capacity and rolling with vibratory roller of capacity 80-100 KN static weight for achieving required compaction density of at least 98% of the maximum Dry Density, consolidating to required gradient and camber complete all as specified and directed 37 Providing, Laying and compacting 225mm thick (compacted thickness) Wet Mix Macadom (WMM) laid in two layersGrading as per Table 400-13 of MORTH specifications for Road and Bridge works, 2013 manufactured in WMM plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreding with sensor paver and rolling with vibratory roller of capacity 80-100 KN static weight and consolidating to required gradient and camber complete all as speccified and directed. The finished surface tolerances to be as per Table 900-1 of MoRTH specifications for Road and Bridge works 2013 38 Preparation of un-surfacced Wet Mix Macadam (WMM) surfaces by sweeping clean by broom or machanical sweepers and removing completely all loose material and other foreign and finally fanning the cleaned surface with air compressors to remove all loose dirt etc. and applying evenly a priming coat of Cationic Bitumin Emulsion SS1 grade, confirming to IS 8887 (latest edition) @ 0.7-1 kg per sq metres on surface of WMM/WBM as specified in Table 500-3 of MORT&H Specifications for Road and Bridge Works 2013 (Fifth Revision), using mechanical sprayer complete all as specified and directed 39 Providing, laying & compaction of Premix Bituminous Macadam (BM) 75 mm or less compacted thickness conforming to Clause 504 of MoRTH Specification for Road and Bridge Works (Fifth Revision), premixed with bituminous binder using Bitumen grade VG-30@4.00% by weight of total mix, laid /rolled and compacted to required gradient and camber level and alignment and rolling with smooth wheeled, vibratory and tandom rollers as per specifications to achieve the desired density complete all as specified 40 Applying evenly a Tack coat conforming to clauses 503-5 of MORT&H specification for Road and Bridge Works 2013 (Fifth Revision), with cationic bituminous emulsion RS1 grade, confirming to IS 8887 (latest edition) @ 0.2 to 0.3 kg per sq meters using mechanical sprayer after cleaning of existing surface as specified and directed 41 Providing and laying 40 mm thick (consolidated thickness) Bituminous premix asphaltic dense concrete conforming to Clause 507 of MoRTH Specification for Road and Bridge Works (Fifth Revision) premixed with bituminous binder using Bitumen grade VG-30@ 5.50% by weight of total mix, laid /rolled and compacted to required gradient and camber level and alignment and rolling with smooth wheeled, vibratory and tandom rollers as per specifications to achieve the desired density complete all as specified 42 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed 43 Material & Labour for preparing bituminous surfaces of road and marking 2.5mm thick centre lines, stop lines, dashes, arrows etc. and the like n. exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed 44 Material and labourfor Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand laid over and including100mm thick PCC 1:4:8 type D-2 using 40mm stone aggregate complete all as specified and as directed. 45 Subtotal 46 Lump sum price worked out by the tenderer for“SEWAGE DISPOSAL WORK" as listed in Schedule ‘A’ Section - V (Part-I) 47 Lump sum price worked out by the tenderer for“AREA DRAINAGE WORK" as listed in Schedule ‘A’ Section - VI (Part-I) 48 Lump sum price worked out by the tenderer for“FENCING AND GATES WORK" as listed in Schedule ‘A’ Section - VII (Part-I) 49 Lump sum price worked out by the tenderer for“EXTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - VIII (Part-I) 50 Sch "A" Sec - VIII (Part-II), (EXTERNAL WATER SUPPLY WORKS) 51 Material and labour for taking branch connection from existingDI/CI pipe upto 150 mm bore of any description,for GI pipe 40 mm boreincludingReducer Tee complete all as specified and directed.. 52 Material and labour for construction of brick mesonary pits of internal dimensions 0.9 mtr x 0.9 mtr x 0.9 mtrs ( bottomPCCfloor of the pit should be minimum 30 cms below the bottom surface of gate valve to provide sufficient working space) , bottom floor of the pit be constructed in PCC (1:3:6) 15 cms thick with 20 mm stone aggregate, inner and exposed surfaces and bottom floor of the pit should be plastered in CM (1:4) 15 MM thick. The gate valve and other fittings should be housed in center of the pit. the vertices of the pit should in right angle and champhered .The top cover of the pit will be made out of MS sheet 3.15 mm thick witth angle iron frame made out of MS angle 50mm x 50 mm x 6 mm with galvanised steel hindges two nos ,and locking arrangements duly painted with two coats of water resistant synthetic enamelled paint over one coat of red oxide as specified and directed.. 53 Subtotal 54 Lump sum price worked out by the tenderer for“EXTERNAL ELECTRIFICATION WORKS" as listed in Schedule ‘A’ Section - IX (Part-I) 55 Sch "A" Sec - IX (Part-II), (EXTERNAL ELECTRIFICATION WORKS) 56 Material and labour for sand cushioning for cables 8 cm below the cable and 15 cm abovewith dry river sand in trenches for cushioningof underground cable line including spreading, leveling, well ramming completed all as specified and directed 57 Cutting of hardstanding floor/wall for laying of cable including matching with suface by using cement concrete all as specified and directed 58 Supplying & laying factory made unreinforced Precast concrete cable coversclass LV type 1, flat, Size 250x150x40mm laid in trenches as protection to cables completeall as directed 59 Material & Labour for XLPE Insulated ,screened, PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core supplied& laidcomplete all as specified & directed. Note: Cost of suitable size of Al thimble for connection of cable with MCCB is included in the unit rate quoted by contractor 60 Supply and errecting in true vertical position steel tubuler swaged poles 9.0 metre long complete withMSbase plate,MS pole cap, bolts nuts & screws as specified type 410 SP-31 including painting of poles with black bitumenous paint throughout the length internally and outside upto planting depth and remaining portion with twocoats of aluminium paint over a coat of red oxide primer, including painting of 05 Nos. bands / strips of 30 cm wide each with two coats of synthetic enamel paint (black & yellow) at a distance of 30 cm from plinth block upto 1500 mm height and marking / sign writing of pole number and feeders locations of pole with synthetic enamel paint (white) complete all as specified and directed.Note: Excavation & earth work shall be measured and paid separately. 61 Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracketwith impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified 62 Material & Labour for wiring from junction box/conductorof street light to street light fitting alongwith earth wire in and including rigid PVC conduits withsizes of 2 x 1.5 sqmm + 1 x 1.5 sqmm earth wire ofFRLSH PVC insulated copper conductor, single core cable on pole with PVC cable connector of suitable sizecompleteall as specified and directed. 63 Supply and fixing street light junctionbox of size 250 mm x 200 mm x 100 mm, made out of hot press moulded SMCwith weather proof hinged door including self locking arrangement, outdoor type weather and vermin proof complete comprising of insulated / high quality PVC sleeves aluminium bus bar of capacity 63 Amps 04 Nos (three phase RBY and black for neutral) with and including 6 Amps MCB single pole, single phase 230 volts, including 25 x 3 mm flat iron mounted on insulators, having arrangement of connecting incoming and outgoing cables complete and all as specified and directed 64 Material & Labour for XLPE Insulated ,screened, PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 2 core supplied& laidcomplete all as specified & directed. Note: Cost of suitable size of Al thimble for connection of cable with MCCB is included in the unit rate quoted by contractor 65 Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised Strip of 32 x 6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. 66 Supply installation, testing and commissioning LT Feeder piller board out door type cubicle panel board suitable for 3 phase,4 wire 415 volt 50 hz factory fabricated approved CPRI powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron section 60X60X6mm frame with front and back openable double door system with locking arragement louver and air vent gasket for netural flow of air with canopy, inner compartment made out of 2 mm the CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arragement with aluminium bus bar three phase and neutral of capacity of 250 amp marked red, yelllow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mmmultistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication , fixed on PCC foundation complete with following accessories:- (a) Incomer MCCB 4P 125 A , 25 KA-1 No.(b) Outgoing MCCB 4 Pole 125 Amps 25 KA -02 Nos (01 working+ 01 standby)(c) Outgoing MCB SPN 32 amp -01 Nos (d) Digital voltmeter (0-500V )(e) Digital Ammeter suitable rating (f) CTS (g) Selector switches and RYB LED indicator Lamp (set of three) 67 Subtotal 68 Sch "A" Sec - X (Part-II), (AC, VENTILATION AND HOT WATER SUPPLY WORKS) 69 Supply and installation of Desert cooler with outer body made of PGI (plain Galvanised Iron) sheet not less than 1.20 mm (18 gauge)thickness for fixed part, thickness of PGI sheet for shutter not less than 0.80 mm (21 gauge) thick front grill made of PGI Sheet with minimum weight 2.80 kgs overall outer size not less than 66cmx66cmx85 cm (height) electric driven copper wounded fan motor (ISI marked)having nominal air flow capacity 4000 Cum per hour and capacity of water storage tank not less than 40 ltr and submersible pump for required flow of water single phase) complete all as specified 70 Supply, Installing and testing of refrigerator electric driven 230 volts single phase , 50Hz supply (5 star BEE rating ) Energy efficient compressor , working on R-600a or superior environment friendly refrigerant puf insulated body having normal storage capacity 423 liters double door type complete all as specified and directed. 71 Supply, Installation, testing and commissioningwater cooler , partially stainless steel ,Electric driven AC(Single phase), 230 Volts, 50HZ Having approx storage Capacity of 80 liters and nominal cooling capacity of 40 Liters per hour all as specified and directed 72 Supply and install air conditioner hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with 3 star rating and EER 3.2.of capacity 1.5 TR with provision of winter heatingcomplete all as specified & directed. 73 Supply and install air conditioner hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with 5 star rating and EER 3.2.of capacity 2.0 TR with provision of winter heating. complete all as specified and directed. 74 Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 to 250 volts with output voltage stabilized at 230 V with accuracy of + 2.5% and of capacity 3 KVAall as specified and directed. 75 Supply and fix copper pipe heavy duty of size 5/8" complete all as specified and directed 76 Supply and fix copper pipe heavy duty of size 3/8" complete all as specified and directed 77 Supply and fix in pipe insulation for copper pipe of size 5/8" and 3/8" complete all as specified and directed 78 Supply and fix wall mounted/ground stand for split AC Outdoor unit 1.5/2.0 Ton as required at site complete all as specified and directed 79 Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA complete all as specified and directed 80 Supply , fabricating and fixing angleiron frame made out of 40x40x5 mm thick suitable for fixing ofDesert cooler includingnecessary civil work, making good the disturbed portionof wall includingcolour/whitewash as per existingsurface complete all as specified and directed.Note: Cost of PCC,Making hole into wall and one red oxide primer coat ,one under coat and one finishing coat ofsynthetic enammel paint is included in this item. 81 Supply and fix ElectricWater heater (Geyser) storage typeof capacity 25 ltr BEE 5 star rated, ABS body, metal tank with glass lined coating multiple heating option, shock safe plug puf insulation, incoly glass coated anode rod/copper heating element with ISI mark, adjustable knob for temp setting with minimum&high working pressure, multi functinoal saftey value, & whirl/swril flow technology, themostat electronic type, complete including superior quality connection pipe heavy duty 15 mm dia 450 mm long, brass adopter for water connection with nickel coated ISI marked with fastener, nut bolt, washers duly grouted, giving shape to hole as suitable and plastering including making good of disturbed surface as per exisiting surface connection to inlet and outlet valves, testing complete all as specified and directed 82 Subtotal 83 Sch "A" Sec - XI (Part-II),“DG SET WORKS 84 Supply, installation, commisioning and testing of diesel engine driven eco-friendlysilent generator set of capacity 40 kVA, 415 Volts, 3 phase 4 wire, 50 Hz, AC supply complete including engine, alternator mounted on common base frame fabricated from steel chanel of suitable size in acoustic enclosure. Engine and alternator shall directly coupled with flexible coupling including with anti vibrating mounting pads as per manufacturer instruction/design complete with pre wired control panel and engine as per IS 10002 1981 (R 2016),Aternator as per IS:13364 part II/ ISO 3046 / BS 5514 complete with controlrelay automatic start on main failureAMF panel and built in fuel tank etc with incl fwg specification/ features all as specified and directed :- NOTE:- (i) Rate for PCC foundation for above mentioned capacity DG set is deemed to be included in quoted rate. (ii) The load test for 12 hrs shall be carried out by the contractor its own cost after completion of entire work.(iii) Necessary instruments consumablestores like engine oil, DHPP, Grease etc and appliances required for carrying out test shall beprovided by the contractor and cost for this is deemed to be included in the quoted rate 85 (a) Diesel Engine :- Diesel engine of 40 KVA/ 32 KW capacity with following provision :- (i) Liquidcooling system (ii) fly wheel (iii) air cleaner (iv) Oil Pump (v) Electric starting system with heavy duty maint free battery and battery charging alternator (vi) Temp meter and oil pressure gauge (vii) Exhaust system of silent DG set shall be provided as per OEM tech (ix) Engine safety sensor ( LLOP & HWT) ; Engine protection device against low lubricating oil pressure or hightemporature and over speeding of engine and emergency stop push button out side the enclosure of DG set, Electronic governor system.(b) ALTERNATOR :- Brushless Alternator having capacity of 40 KVA/ 32 KW output at power factor 0.8, AC 3 phase, 4 wire, 415 Volts, 50 Hz, 1500 RPM, screen protected, revolving field, self excited, self regulated through an AVR.The alternator has the following features : - (i) H class insulations. (ii) Plus/minus 1% of voltage regulation (max) in static condition. (c) CONTROL & AMFPANEL BOARD:- (i) The control panel is manufactured with 16/18 guage CRCA sheet and is powder coated for a wheather proof and long lasting finish.The control panel/AMF panel consists of Microprocessor based DES 9 electronics controller, MCCBs of suitable rating, Key switche, Push button (Starter), LED battery charging alternator fail indication, current transformer, instrument fuses, Sound proof and weather proof encosure with safety features.- MCB of suitable rating with short circuit protection- Controller which displays voltage, current, KW, PF, Frequency, KWh.- Indicating lamps for “Load On” and “Set Running”- Current transformers of suitable ratings- Copper Cables of suitable capacity with incoming and Outgoing terminations- Control fuses duly wired and ferruled(d)Platform for placing of DG set ofdimensions 2 m x 1.2 m with height of 200mm above and 300 mm below GL with 150 mm hard core of stone aggregate, 100 mm thick sub base of PCC 1:5:10 & 75 mm thick PCC 1:2:4 type "B" as in floor finish smooth with one brick thick in outer wall in CM 1:4, plaster 15 mm thick in Cm 1:6 finished with cement based Paint including excavation and removal of surplus soil 86 Subtotal 87 Lump sum price worked out by the tenderer for“EXCAVATION, EARTHWORK AND SITECLEARANCE DEVELOPMENT WORK" as listed in Schedule ‘A’ Section - XII
|