Hepr Cable 90ºc 0.6/ 1 Kv 1.50Mm Colors To Be Defined: Conductor Recommended For Installations In Residential, Commercial, Industrial Buildings And Substations. Suitable For Fixed Applications That Require Greater Mechanical Protection Of The Insulating Material, Including Good Resistance To Humid Environments. Conductor Formed By Bare Copper Wires, Soft Temper, Class 2 Stranding. Hepr 90°C Insulation - Extruded Thermosetting Compound Based On High Modulus Ethylenepropylene. Pvc/St2 Cover 90°C - Extruded Thermoplastic Compound Based On Polyvinyl Chloride. Applicable Standard Nbr 7286. Maximum Conductor Temperature 90°C Permanently; 130°C In Overload Regime And 250°C In Short-Circuit Regime., Flexible Cable Bwf 750 V 2, 50Mm Colors To Be Defined: Conductor With Non-Propagation And Self-Extinguishing Fire Characteristics. Used In Applications Where Cables With Greater Flexibility Are Required, Such As In Power Distribution Networks For Residential, Commercial And Industrial Buildings, Panel Connections And Electrical Motors. Flexible Bare Copper Conductor, Class 4 Or Class 5 Stranding. Pvc Insulation At 70°C - Extruded Thermoplastic Compound Based On Polyvinyl Chloride, With Special Characteristics For Non-Propagation And Self-Extinguishing Of Fire. Applicable Standard Nbr Nm 247-3., Flexible Cable Bwf 750 V 4.00Mm Colors To Be Defined: Conductor With Characteristics Of Non-Propagation And Self-Extinguishing Of Fire. Used In Applications Where Cables With Greater Flexibility Are Required, Flexible Cable Bwf 750 V 6.00Mm Colors To Be Defined Conductor With Characteristics Of Non-Propagation And Self-Extinguishing Of Fire. Used In Applications Where Cables With Greater Flexibility Are Required, Flexible Cable Bwf 750 V 10.0Mm Colors To Be Defined Conductor With Characteristics Of Non-Propagation And Self-Extinguishing Of Fire. Used In Applications Where Cables With Greater Flexibility Are Required, 6/ 1 Kv 10.0Mm Colors To Be Defined: Recommended Conductor For Installations In Residential Buildings, 6/ 1 Kv 16. In Residential Buildings, 6/ 1 Kv 35, 6/ 1 Kv 50, 6/ 1 Kv 70, Pp Cable 750 V, 2X1, 5Mm, Blue And Black Conductors, 2X2, 2X4, 0Mm, 2X6, 4X1, Blue, Black, Red, White Conductors, 4X2, 4X4 , 4X6, 4X10, 6/ 1 Kv 2.5Mm Colors To Be Defined: Conductor Recommended For Installations In Residential Buildings, Class 2 Stranding. Hepr 90°C Insulation - Extruded Thermoset Compound Based On High Modulus Ethylene Propylene. Pvc/St2 Cover 90°C - Extruded Thermoplastic Compound Based On Polyvinyl Chloride. Applicable Standard Nbr 7286. Maximum Conductor Temperature 90°C Permanently; 130°C In Overload Regime And 250°C In Short-Circuit Regime., 6/ 1 Kv 6 Mm Colors To Be Defined: Conductor Recommended For Installations In Residential Buildings, 6/ 1 Kv 95 Mm Colors To Be Defined: Conductor Recommended For Installations In Residential Buildings, Copper Cable Number 25, 0Mm 07 Soft Temper Standardized Wires: Use: Rigid Conductor Recommended For Heavy Metal Free Grounding Systems, Conductor Formed By Bare Copper Wires, Soft Temper, Stranding Class 2. Applicable Standard Nbr 5349., Copper Cable Number 35, Aluminum Cable Multiplexed 0.6/1 Kv Single Phase (1X1x10+10.0Mm): Self-Supporting Multiplexed Power Cable, Designed For Power Supply And Power Distribution Circuits At Voltages Of Up To 0.6/1 Kv, In Aerial Installations Fixed To Poles Or Facades. Xlpe Insulation 90°C - Extruded Thermosetting Compound Based On Polyethylene
|