Tender For 33/11 K.V. Substation At Hanuman Vihar Aawasiya Yojna At Chhatikara Radhakund Road, Mathura - Supply Installation Testing and Commissioning of 5 MVA 33/11 KV Power Transformer Three phase CRGO cooper wound as per UPPCL alongwith making of required size plinth as per OEM and site requirement and conducting all the site test before charging the same as per requirement and approval of engineer in charge. Sl.No. 94 2 Supply Installation Testing and Commissioning of 33KV Isolators (800 Amps), with clamps alongwith making of required size plinth as per OEM and site requirementSl.No. 78 3 Supply Installation Testing and Commissioning of 33 KV VCB, 1250A for out door use alongwith making of required size plinth as per OEM and site requirement and conducting all the site test before charging the same as per requirement and approval of engineer in charge. Sl.No. 85 4 Supply Installation Testing and Commissioning of 33 KV C&R panel 24 V DC Operated suitable for controlling of one T/F(With Differential protection, master relay & 10 window auxre relay) alongwith making of required size plinth as per OEM and site requirement and conducting all the site test before charging the same as per requirement and approval of engineer in charge. Sl.No. 117 5 Supply Installation Testing and Commissioning ofBattery Charger 24Volt alongwith making of required size plinth as per OEM and site requirement and conducting all the site test before charging the same as per requirement and approval of engineer in charge. Sl.No. 114 6 Supply Installation Testing and Commissioning ofBattery Set 24Volt.complete in all respect as per direction and approval of Engineer-in-charge.Sl.No. 115 7 Supply Installation Testing and Commissioning of33KV Lightening ArrestorSub-Stn Type 30KV 10KA with surge counter alongwith making of required size plinth as per OEM and site requirement and conducting all the site test before charging the same as per requirement and approval of engineer in charge. Sl.No. 80 8 Supply Installation Testing and Commissioning of 33KV CTs 400-200/1-1-1 A with Junction Boxcomplete in all respect as per direction and approval of Engineer-in-charge.Sl.No. 83 9 Supply Installation Testing and Commissioning of 33KV CTs 200-100/1-1-1 A with Junction Box Sl.No. 82 10 Supply Installation Testing and Commissioning of 33KV PTs with junction box.complete in all respect as per direction and approval of Engineer-in-charge.Sl.No. 75 11 Supply Installation Testing and Commissioning of 33KV Post insulators. Sl.No. 97 12 Supply Installation Testing and Commissioning of 11KV Disc insulators 45KN T & C Type. complete in all respect as per direction and approval of Engineer-in-charge. Sl.No. 39 13 Supply Installation Testing and Commissioning of Disc Fitting (T&C Type) Sl.No. 43 14 Supply Installation Testing and Commissioning of 11KV VCB, I/C CTR 600/300/5A, 350MVA (1250A).complete in all respect as per direction and approval of Engineer-in-charge.Sl.No. 76 15 Supply Installation Testing and Commissioning of 11KVVCB, FOR O/G CTR 200/100/5A, 350MVA (1250A). Sl.No. 77 16 Supply Installation Testing and Commissioning of 11KV Buscoupler complete in all respect as per direction and approval of Engineer-in-charge.Sl.No. 121 17 S/F of 11 Lightening Arrester with line side terminal connectors suitable for vertical as well as horizontal entry of conductor. The base of Lightening Arrester shall be short circuited through a GI strip size 35mmx5mm or of equivalent cross section. complete in all respect as per direction and approval of Engineer-in-charge. PSR 18 Supply Installation Testing and Commissioning of 3 Phase Distribution box.Sl.No. 122 19 Supply, Installation Testing and commissioning of 11 KV VCB capacitar bank .complete in all respect as per direction and approval of Engineer-in-charge.PSR 20 S/E of steel structures for 33kv lighting arrestors/post insulater/CTs/DO fuse sets and for MOCBs made of M.S. channel 100x50mm, 7.9kg/m. top of M.S. angle 50x50x6mm, 4.5kg/mtrs lighting arrestors/post insulators are to be mounted on M.S. plate of 200x150x8mm. Height of structure to be 2.5m above ground and 1m below ground on 1.75mm thick cement concrete pad with 1:4:8 cement concrete foundation making plinth of required height including all fabrication as per drawing and as per direction of E/I. PSR 21 S/E of 33kv line isolator/bus isolator structure made of 125mmx65mm(10.7kg/m). Channel at a height of 2.5m. Above ground and 1m below ground on a cement concrete pad of 75m thick with 1:2:4 cement concrete foundation size 1000mmx900mmx1800mm including excavation back filling making plinth of required height and with required fabrication for obracing of M.S. flat 50x6mm, and top of M.S. angle size 75x75x8mm. PSR 22 S/E of busbar gantry structure of M.S. channel 150x150mm 27.10 kg/m 6.40 m above the ground level and 1.20m below G.I. The gantry shall be grouted in 1:2:4 cement concrete foundation size 2000mmx1000mmx1800mm (including 300mm plinth above G.I.) mounted on stone pad of 300x300x75mm including earth excavation back filling making plinth of required height and with requird fabrication as per drawing no. 2 complete in all respect as per deirection of E/I. PSR 23 S/E of terminal gantry structure of M.S. channeljoist 150mmx150mm, 8.5m long with 3.2m long sopport of same section. The gantry shall be grouted 1.8m below G.I. with 0.3m plinth above. G.I. in cement concrete (1:2:4) in foundation of size 2.20mmx0.190mmx1800 mm with plinth mounted on a stone pad of 300x300x75mm including earth excavation work filling making plinth of required height and with required fabrication as per drawing no. 1. complete in all respect as per direction of E/I. PSR 24 S/E ACSR Conductor (Panther).complete in all respect as per direction and approval of Engineer-in-charge. Sl.No. 57 25 Supply and laying of following Cable AL. 3 Core 300 sq.mm XLPE 11 KV. complete in all respect as per direction and approval of Engineer-in-charge. Sl.No. 15 26 Supply/ fixing and jointing of 3 core 300 sqmm indoor type 11 KV jointing kit push on type on type for 11 KV cable including cost of all material labour, T&P etc. for proper completion of the E/I. Sl.No. 102 27 Supply/ fixing and jointing of 3 core 300 sqmm outdoor type 11 KV jointing kit push on type on type for 11 KV cable including cost of all material labour, T&P etc. for proper completion of the E/I. Sl.No. 102 28 Supply and laying of following Cable AL. 3 Core 185 sq.mm XLPE 11 KV. complete in all respect as per direction and approval of Engineer-in-charge. Sl.No. 14 29 Supply and laying of following Cable AL. 3 Core 70 sq.mm XLPE 11 KV. complete in all respect as per direction and approval of Engineer-in-charge. Sl.No. 12 30 Supply/ fixing and jointing of 3 core 185 sqmm outdoor type 11 KV jointing kit push on type on type for 11 KV cable including cost of all material labour, T&P etc. for proper completion of the E/I. Sl.No. 100 31 Supply/ fixing and jointing of 3 core 185 sqmm indoor type 11 KV jointing kit push on type on type for 11 KV cable including cost of all material labour, T&P etc. for proper completion of the E/I. Sl.No. 100 32 Supply/ fixing and jointing of 3 core 70 sqmm indoor type 11 KV jointing kit push on type on type for 11 KV cable including cost of all material labour, T&P etc. for proper completion of the E/I. Sl.No. 98 33 Supply/ fixing and jointing of 3 core 70 sqmm outdoor type 11 KV jointing kit push on type on type for 11 KV cable including cost of all material labour, T&P etc. for proper completion of the E/I. Sl.No. 98 34 SITC of 11/0.44 KV, 63KVA copper wouned type tested transformer duly apporved by D.V.V.N.L., mathura.complete in all respect as per direction of E/I. PSR 35 Supply and laying of LT PVC Armoured cable 2 Core 10 sq.mm . complete in all respect as per direction and approval of Engineer-in-charge. Sl.No. 28 36 Supply and laying of un armoured copper control cable 2 Core 4 sq.mm . complete in all respect as per direction and approval of Engineer-in-charge. MR 37 Supply and laying of un armoured copper control cable 2 Core 6 sq.mm . complete in all respect as per direction and approval of Engineer-in-charge. MR 38 Supply and laying of un armoured copper control cable 3 Core 4 sq.mm . complete in all respect as per direction and approval of Engineer-in-charge. MR 39 Supply and laying of un armoured copper control cable 4 Core 4 sq.mm . complete in all respect as per direction and approval of Engineer-in-charge. MR 40 Supply and laying of un armoured copper control cable 4 Core 6 sq.mm . complete in all respect as per direction and approval of Engineer-in-charge. MR 41 Supply and laying of un armoured copper control cable 7 Core 2.5 sq.mm . complete in all respect as per direction and approval of Engineer-in-charge. MR 42 Supply and laying of un armoured copper control cable 10 Core 2.5 sq.mm . complete in all respect as per direction and approval of Engineer-in-charge. MR 43 Supply/laying of 50mmx6mm G.I. strip including cartage, cutting welding etc. as per direction and approval of Engineer-in-charge. PSR 44 Supply & fixing of 8mtr GI Octagonal Pole of approved make(top dia 70mm, Bottom dia 130 mm and base plate 12mm thik) having 3mm thikness with single arm bracket(1 Mtr length) on RCC foundationincluding the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect.PWD 2018 643 45 Supply and fixing ofLED Street light Fittinghaving die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and aboveProtection complete in all respect. CAT- AAA. PWD 2018 1423 46 Supply and fixing of CO2 type fire extinguisher,4.50 Kg. capacity (ISI Mark) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. PSR 47 S/F of 11 KV TPMO switches 3 pole hand operated single break without earthing contact plate and suitable for vertical mounting and double pole/four pole structure with material & labour etc. complete in all respect as per direction and approval of Engineer-in-charge.PSR 48 Supply and burying of 600mmx600mmx6.0 mm G.I. plate verically for earthing with its top at least 3 meters below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of one no. 8 to 10 SWG G.I. wire in 15 mm dia G.I. pipe up to (switch board form appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30 cm square C.I. frame with hinged cover masonary housing alternate layers of charocal/coke and salt at least 150 mm thick alround etc as per directions of E/I complete in all respect. PSR 49 Supply and burying of MS Earthing rod (2540x20mm) as per directions of E/I complete in all respect.Sl no. 65 50 Supply and burying of 40mm diax15 meters long G.I. pipe vertically for earthing having 12mm dia holes spaced 75 mm aprat drilled up to 2 metre from the bottom complete with earthing lead of no. 6 to 8 SWG GI wire in G.I. pipe up to appron (and form appron to switch board the cost of G.I.wire and pipe will be extra) up to switch board 30 cm square C.I. box with hinged cover masonary enclosure, funnel at top, altenate layers of charcoal/coke and salt ate least 150 mm thick alround etc. as per directions of E/I complete in all respects. as per drawing PSR 51 S/L of 1800x900x12 mm. thick chequered rubber matting of testing quality. PSR 52 Excavation of trench of size (0.60x0.60x0.75 metre) PSR 53 Supply laying & fixing of earthing mat of 32 mm dia M.S. rod including cartage, cutting, welding and binding etc. PSR 54 Supply & fixing of Disx, insulator (BHEL or equivalent make) 70 KN E&M strength with tension fitting (B&S tpye) suitable for disc insulator complete in all respects. PSR 55 Supply & fixing of P.G. clamps suitable for log to dog conductor for jumpering PSR 56 S/F of 33 kv DO fuse set 200 Amp. Verical mounting complete with isolator. PSR 57 Construction of control cable duct/trench of requiredsize in messonarey brick work in 1:3 with plaster size (2x1x0.35x0.3+2x1x0.23x0.45) with plaster 4 D.P.C in 2 Cm thick. PSR 58 Supply and filling & laying of 20 mm stone grit in yard of size 21x42 mtr x 0.10 mtr thick complete in all respects.PSR 59 Supply and buryig of water level earthing as per direction by E/I. PSR 60 Supply and laying of 150 mm dia G.I. pipe complete with clamp for supporting of cables. PSR 61 S/F danger board fabrication from 10 gauge M.S sheet as per IE rules PSR 62 Supply and laying of D.W.C. HDPE pipe size 200/170. PSR 63 Supply and Errection of Double Pole comprising of 2 Nos.410 SP-55 Steel tubular Pole including 3 Nos. 100x50mm MS channel 2.24 M long and 1 No. 75x40mm MS channel 2.24 M long, clamps, packing pieces etc duly painted complete in all respect as per direction and approval of Engineer-in-charge. PSR 64 Supply and erection of stay set at least 3.5 metres away from the pole complete with galvanised 19mm dia. x 1.800 metre long stay rod, 30cm x 30cmx6.3 mm anchor plat, thimble stay clamps, stay insulator. 19mm x 600mm double serew tightener, 7/4.00mm G.I. stay wire etc. in 1:3:6 cement concrete in all respects. PSR 65 Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. PSR 66 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 33 volts grade at a depth of 750 mm bleow ground level over a cushion of 75 mm. Thick sand all arounded protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.400 sqmm 3 core XLPE 33 KV - HT Cable. PSR 67 S/F end box out door type for 33 KVA 3 core400 sqmm cable XLPE. PSR 68 Supply fixing and installation of FRP transfermar cage complete with brick work plaster etc. as per direction Engineer incharge and UPPCCL specification.PSR 69 S/F of Tubular pole SP-69-13 M long in 1:3:6 cement conceret foundation including excavation backfilling etc complete in all respect. PSR 70 S/F of 0.30 M 100 x 50 mm size MS channel for pin insulator, F bracket including duly painted with over red oxide paint. PSR 71 S/F of V shape cross arm made of MS channel of size not less than 100mm x 50mm x 6mm of the length 1.8 M including D clamp duly painted with over red oxide paint material and labour all complete as per direction by E/I. PSR 72 S/F of straight MS channel 100 x 50 mm 1.8 M long including clamp nut bolt etcduly painted with over red oxide paint material and labour all complete as per direction by E/I. PSR 73 S/F of straight MS channel 75x 40x5 mm 2.1 M long for guarding including clamp nut bolt etcduly painted with over red oxide paint material and labour all complete as per direction by E/I. PSR 74 S/E of hexagonal/ cradel type gaused of GI wire no. 8x4 SWG including binding etc complete as per direction by E/I. PSR 75 S/F of GI Nuts, Bolts & Washer off all required sizes. MR 76 S/F of Hot dip Galvanised Eye Screw Bolt 9"x5/8". MR 77 Supply & fixing of 33 kv pin insulator (BHEL or equivalent make) with pin. PSR 78 S/B of 40 mm dia., 3000 mm long GI pipe earth electrode with test link, RCC pit, RCC cover plates on GI frame, bentonite powder and other accessories complete. MR 79 S/F of Barbed Wire. MR 80 Phase Indication Plates for each phase set of 3 (On H•Pole & d Pole). MR 81 S/E of overhead line with ACSR conductor on poles including binding etc. complete in all respects. PSR 82 Painting of the electric poles with two coats of aluminium paint over red oxide primer complete in all respect. PSR
|