Rate Contract For The Procurement Of Consumables/Non-Consumables For The Department Of Clinical Immunology , Note: For All Items, Sample Should Be Submitted. Without Sample Quotation Will Be Rejected Immunoflorescence, Elisa And Other Kits , Ana-Hep-20-10/ Liver Monkey (Igg, Ifa Slide Test (Pack Size 10 X 10 Per Kit) , Anca Ifa Slide Test Kit (Granulocyte, Ethanol/Formaline Fixed)(Per Kit -250 Tests) , Anti-Ds-Dna, Elisa (Per Kit - 96 Tests) , Anti-Cardiolipin-Igg,Elisa (Per Kit - 96 Tests) , Anti-Cardiolipin- Igm, Elisa (Per Kit - 96 Tests) , Anti B2gpi-Igg, Elisa (Per Kit - 96 Tests) , Anti B2gpi-Igm, Elisa (Per Kit - 96 Tests) , Anti Phosphotidyl Serine/Prothrombin Igg, Elisa(Per Kit - 96 Tests) , Anti Phosphotidyl Serine/Prothrombin Igm, Elisa(Per Kit - 96 Tests) , Anti Ccp, Elisa (Per Kit - 96 Tests) , Interferon Gama Release Assay (Per Kit -100 Tests) , Ena - Line Immunoassay (Containing 17 Antigens) (Per Kit-24 Strips) , Myositis Profile 4 - Line Immunoassay (Containing 16 Antigens) (Per Kit-16 Strips) , Autoimmune Liver Disease - Line Immunoassay (Containing 14 Antigens) (Per Kit-16 Strips) , Systemic Selerosis Profile (Nucleoli) Igg - Line Immunoassay (Containing 13 Antigens) (Per Kit -16 Strips) , Anti Mpo/Pr3 And Gbm (Igg) - Line Immunoassay (Containing 3 Antigens) (Per Kit -16 Strips) , Molecular Biology Grade (Mb)Chemicals , Tritonx 100, 100 Ml , Sucrose, 500 Gm , Mgcl2 , 500Gm , Disodium Edta , 500Gm , Sodium Chloride -500Gm , Chloroform- 500Ml , Tris Free Base - 500Gm , Ethanol (Mb Grade) - 500 Ml , Iso Propyl Alcohol (Mb Grade)- 1L , Trizol Ls - 200Ml , Tris Equilibiriated Phenol Ph 7.8 100Ml , Proteinase K - 100Gm , Ammonium Chloride - 500Gm , Ammonium Bicarbonate - 500Gm , 10% Sodium Dodecyl Sulphate (Sds) - 500Gm , Octanol (1 Liter) , Hydrochloric Acid (1 Liter) , Dimethyl Sulphoxide (Dmso) - 100Ml , Taq Dna Polymerase With 10 X Buffer Like Invitrogen - 100U , Dntp’S Set- (4X100µl) 100Mm Each , High Capacity Cdna Synthesis Kit (200 Reaction Per Kit) , Hla B27 Primers B1: 5-Gct Acg Tgg Acg Aca Cgc T -3 (100 ?M) , Hla B27 Primers B2: 5-Ctc Ggt Cag Tct Gtg Cct T -3 (100 ?M) , Hla B27 Primers B3: 5-Tct Cgg Taa Gtc Tgt Gcc Tt -3 (100 ?M) , Hla B27 Primers C1: 5-Tgc Caa Gtg Gag Cac Cca A -3 (100 ?M) , Hla B27 Primers C2: 5-Gca Tct Tgc Tct Gtg Cag At -3 (100 ?M) , Real Time Taqman Universal Mastermix (Compatible For Abi Step One Plus System) - 5Ml , Agarose (Low Eeo) 500Gm , Dna Marker (100 Bp Ladder) (250?G) , Dna Marker (1 Kb Ladder) (250 ?G) , Analytical Grade (Ar)Chemicals , Tris Buffer 500 Gm , Ethanol 500 Ml , Boric Acid 500 Gm , Sodium Chloride -500Gm , Potassium Permanganate 500 Gm , Formaldehyde Solution 500 Ml , Disodium Hydrogen Phosphate 500 Gm , Potassium Dihydrogen Phosphate 500 Gm , Sodium Azide 500 Gm , Potassium Chloride 500 Gm , Tissue Culture (Tc) Grade Chemicals And Consumables , Glycerol 500Ml , Lymphocyte Separation Medium(Ficoll) (Density 1.077 G/Ml - 100Ml , Trypan Blue Solution (0.4%) 100Ml , Dmso - 100Ml , Formaldehyde Solution 500Ml , Para Formaldehyde 16% 500Gm , Pottasium Permanganate Powder 500 Gm , Pbs Sachets (Without Calcium, Magnesium And Phenol Red) (1X) (Pack Size :10 Sachets/Pkt) , Fbs, Us Origin,500 Ml , Syringe Filters (0.2 ?M Ca Membrane, 28 Mm) (Sterile, Ready To Use) , Syringe Filters (0.45 ?M Ca Membrane, 28 Mm) (Sterile, Ready To Use) , Color Changing Tape To For Adequacy Of Sterilization (Per Pack 4 Rolls) , Disposable Graduated Serological Pipettes Sterile (1Ml) (Per Pack 100 Nos) , Disposable Graduated Serological Pipettes Sterile (2Ml) (Per Pack 100 Nos) , Disposable Graduated Serological Pipettes Sterile (5M) (Per Pack 100 Nos) , Disposable Graduated Serological Pipettes Sterile (10Ml) (Per Pack 100 Nos) , Disposable Graduated Serological Pipettes Sterile (25Ml) (Per Pack 100 Nos) , Mononuclear Cell Preparation Tubes (Cpt) With Sodium Citrate -8Ml (60/Case) , Mononuclear Cell Preparation Tubes (Cpt) With Sodium Heparin -8Ml (60/Case) , Mononuclear Cell Preparation Tubes (Cpt) With Sodium Citrate -4Ml (60/Case) , Mononuclear Cell Preparation Tubes (Cpt) With Sodium Heparin -4Ml (60/Case) , Hla Typing Kits - Pcr Ssp (The Item No. 5.078 -7.111Are Part Of A Single Test And Therefore Required From A Single Manufacturer) , Hla Class I (A) Typing Kit (Pcr Ssp) (Per Kit-12 Tests) , Hla Class I (B) Typing Kit (Pcr Ssp) (Per Kit-8 Tests) , Hla Class I (C) Typing Kit (Pcr Ssp) (Per Kit-16 Tests) , Hla Class Ii (Drb1) Typing Kit (Pcr Ssp) (Per Kit-40 Tests) , Hla Class Ii (Dqb1) Typing Kit (Pcr Ssp) (Per Kit-24 Tests) , Hla Class I & Ii (A,B, Drb1) Combitray (Per Kit-10 Tests) , Hla Class Ii(Drb1 & Dqb1) Typing Kit (Per Kit-40 Tests) , Hla B51 Typing Kit (Real Time Pcr) (Per Kit-10 Tests) , Hla Typing Kits - Pcr-Sso (Luminex Based) , Hla - A Sso Typing Kit (Per Kit - 50 Test) , Hla - B Sso Typing Kit(Per Kit - 50 Test) , Hla - C Sso Typing Kit (Per Kit - 50 Test) , Hla - Drb1 Sso Typing Kit(Per Kit - 50 Test) , Hla - Dqb1 Sso Typing Kit (Per Kit - 50 Test) , Hla-A-B-Drb1 Pcr Sso Typing Kit (Per Kit - 50 Test) , 96 Well Filter Microplate (50/Pk) , 96 Well Unskirted Costar Plates (50/Pk) , Sealer For 96 Well Costar Plates (100/Pk) , Sape Solution , Sheath Fluid20 Liters Compatible With Luminex 200 , Calibration Kit (25 Doses) Compatible With Luminex 200 , Performance Verification Kit(25 Doses) Compatible With Luminex 200 , 12 Month Pm Kit Compatible With Luminex 200 , Taq Dna Polymerase Compatible For Pcr-Sso Hla Kits (125 Units; 25?L) , Hla Antibody Screening (Luminex Based) , Panel Reactive Antibodieshla Class I (Per Kit - 24 Test) , Panel Reactive Antibodieshla Class Ii (Per Kit - 24 Test) , Panel Reactive Antibodieshla Class I & Class Ii (Per Kit - 96 Test) , Single Antigen Hla Class I (Per Kit - 24 Test) , Single Antigen Hla Class Ii(Per Kit - 24 Test) , Mixed Class I & Class Ii , Donor Specific Antibody Screening By Luminex (Classi & Classii) (Per Kit - 96 Test) , Negative Control Serum , Pe-Conjugated Goat Anti-Human Igg , Pe-Conjugated Streptavidin , Fitc-Conjugated Mouse Anti Human-Igg , Hla Antibody Screening (Flow Cytometer Based) , Class I Positive Control , Class Ii Positive Control , Negative Control , Hla Class I & Ii Screening Test , Hla Class I Screening Test , Hla Class Ii Screening Test , Wash Buffer (10X) , Reagent Pack , Control Beads , Dsa-Xm , Secondary Antibody For Flow Crossmatch , Percp Conjugated Anti Human-Cd3 , Pe Conjugated Anti Human-Cd19 , Fitc Conjugated Mouse Anti Human-Igg , Pe Conjugated Anti Human-Cd22 , Lymphocyte Isolation/Enrichment Kit , Lymphocyte Isolation/Enrichment Tube , Pbmc Isolation Kit , Pbmc Isolation Tube , Anti Hla Positive Control , Anti Hla Positive Control B Cell , Anti Hla Positive Control T Cell , Anti Hla Negative Control , General Consumbles , Screw Cap Centrifuge Tube 50Ml; Colorless, Clear, Sterile, Pyrogen, Dnase, Rnase, Human And Bacterial Dna-Free. Autoclavable Medical Grade Pp/Hdpe Confirming To Usp Class Vi (Per Box 500 Nos) , Plug Seal Cap Centrifuge Tube 50Ml; Colorless, Clear, Sterile, Pyrogen, Dnase, Rnase, Human And Bacterial Dna-Free. Autoclavable. Medical Grade Pp/Hdpe Confirming To Usp Class Vi (Per Box 500 Nos) , Screw Cap Centrifuge Tube 15Ml; Colorless, Clear, Sterile, Pyrogen, Dnase, Rnase, Human And Bacterial Dna-Free. Autoclavable. Medical Grade Pp/Hdpe Confirming To Usp Class Vi (Per Box 500 Nos) , Plug Seal Cap Centrifuge Tube 15Ml; Colorless, Clear, Sterile, Pyrogen, Dnase, Rnase, Human And Bacterial Dna-Free.Autoclavable. Medical Grade Pp/Hdpe Confirming To Usp Class Vi (Per Box 500 Nos) , Microcentrifuge Tube, 2 Ml With Hinged Safe-Lock Lid. Colorless, Clear, Sterile, Pyrogen, Dnase, Rnase, Human And Bacterial Dna-Free. Should Be Suitable For 30,000G And Withstand Upto -86 °C To 100 °C. Should Be Superior Quality And Manufactured Without Slip Agents And Pp Material Confirming To Us Fda 21 Cfr Autoclavable (Per Box 500 Nos) , Microcentrifuge Tube, 1.5 Ml With Hinged Safe-Lock Lid. Colorless, Clear, Sterile, Pyrogen, Dnase, Rnase, Human And Bacterial Dna-Free. Should Be Suitable For 30,000G And Withstand Upto -86 °C To 100 °C. Should Be Superior Quality And Manufactured Without Slip Agents And Pp Material Confirming To Us Fda 21 Cfr Autoclavable (Per Box 500 Nos) , Microcentrifuge Tube, 0.5 Ml With Hinged Safe-Lock Lid. Colorless, Clear, Sterile, Pyrogen, Dnase, Rnase, Human And Bacterial Dna-Free. Should Be Suitable For 30,000G And Withstand Upto -86 °C To 100 °C. Should Be Superior Quality And Manufactured Without Slip Agents And Pp Material Confirming To Us Fda 21 Cfr Autoclavable (Per Box 1000 Nos) , Pcr Strips With Flat Cap 0.2Ml (8 Tube Per Strips). Colorless, Clear, Sterile, Pyrogen, Dnase, Rnase, Human And Bacterial Dna-Free. Compatible To Veriti And Verity Propcr System(Per Pack 125 Nos) , Pcr Strips With Flat Cap 0.1Ml (8 Tube Per Strips). Colorless, Clear, Sterile, Pyrogen, Dnase, Rnase, Human And Bacterial Dna-Free. Compatible To Veriti And Verity Propcr System(Per Pack 125 Nos) , Pcr Strips Tubes With Attached Caps 0.2Ml (8 Tubes Per Strip). Colorless, Clear, Sterile, Pyrogen, Dnase, Rnase, Human And Bacterial Dna-Free. Compatible With Veriti And Verity Propcr System (Per Pack 125 Nos) , Pcr Strips Tubes With Attached Caps 0.1Ml (8 Tubes Per Strip). Colorless, Clear, Sterile, Pyrogen, Dnase, Rnase, Human And Bacterial Dna-Free. Compatible With Veriti And Verity Propcr System (Per Pack 125 Nos) , Colorless, Sterile, Dnase, Rnase, Dna, Atp, Pcr Inhibitor, And Pyrogen Free, Virgin Polypropylene, Autoclavable, Low Retention Micropipette Tips: 0.2 – 10?L.(Per Pack 1000 Nos) , Colorless, Sterile, Dnase, Rnase, Dna, Atp, Pcr Inhibitor, And Pyrogen Free, Virgin Polypropylene, Autoclavable,Low Retention Micropipette Tips: 20-200?L.(Per Pack 1000 Nos) , Colorless, Sterile, Dnase, Rnase, Dna, Atp, Pcr Inhibitor, And Pyrogen Free, Virgin Polypropylene, Autoclavable,Low Retention Micropipette Tips: 100-1000?L.(Per Pack 1000 Nos) , Polypropylene Autoclavable Pipette Tip Box0.2–10 ?L. Should Be Sturdy To Resist Tipping While In Use. Hinged Lids To Protects The Tips From Contamination. The Latch Shouldkeep The Box Closed While Not In Use (Per Pack 10 Boxes) , Polypropylene Autoclavable Pipette Tip Box 2–200 ?L. Should Be Sturdy To Resist Tipping While In Use. Hinged Lids To Protects The Tips From Contamination. The Latch Shouldkeep The Box Closed While Not In Use (Per Pack 10 Boxes) , Polypropylene Autoclavable Pipette Tip Box 100-1000?L. Should Be Sturdy To Resist Tipping While In Use. Hinged Lids To Protects The Tips From Contamination. The Latch Shouldkeep The Box Closed While Not In Use (Per Pack 10 Boxes) , Polycarbonate, Cryo Safe Storage Box For 0.5Ml Microcentrifuge Tubes (81 Places). Boxes Should Have Removable, Numbered Transparent Lid, With Frosted Labeling Area. Foam To Hold Tubes Securely. (Per Pack 4 Boxes) , Polycarbonate, Cryo Safe Storage Box For 2Ml/1.5Ml Centrifuge Tubes (81 Places). Boxes Should Have Removable, Numbered Transparent Lid, With Frosted Labeling Area. (Per Pack 4 Boxes) , Polycarbonate, Cryo Safe Storage Box For 15Ml Centrifuge Tubes (81 Places). Boxes Should Have Removable, Numbered Transparent Lid, With Frosted Labeling Area. (Per Pack 4 Boxes) , Autoclavable Polypropylene Microtube Rack For 96 × 0.5 Ml Microcentrifuge Tubes On One Side, Or 96 × 1.5 - 2.0Ml Microcentrifuge Tubes On The Other. The Rack Should Be Arranged In The Standard 8 × 12 Array And Numbered , Heavy Weight Polypropylene, Four-Way Microtube Rack That Can Hold 4 X 50 Ml Tubes; 12 X 15 Ml Tubes; 32 X 1.5-2 Ml Tubes; 32 X 0.5 Ml Tubes , Autoclavablepolypropylene Ria Vials 12X75 Mm (Per Pack 500 Nos) , Autoclavable Self-Standing Dnase, Rnase And Pyrogen Free Cryogenic Vials With Caps (For Liquid Nitrogen Storage) - 1.8Ml (Per Pack 1000 Nos) , Nitrile Gloves; Large: Disposable, Sterile; Latex And Powder-Free With Textured Fingertips To Provide Extra Grip For Wet Or Dry Applications. Should Fulfill Aql 1,5, En 420, En 374 1/5 And En 455 1/2/3 Standards (Per Pack 100 Nos) , Nitrile Gloves; Medium: Disposable, Sterile; Latex And Powder-Free With Textured Fingertips To Provide Extra Grip For Wet Or Dry Applications. Should Fulfill Aql 1,5, En 420, En 374 1/5 And En 455 1/2/3 Standards (Per Pack 100 Nos) , Nitrile Gloves; Small: Disposable, Sterile; Latex And Powder-Free With Textured Fingertips To Provide Extra Grip For Wet Or Dry Applications. Should Fulfill Aql 1,5, En 420, En 374 1/5 And En 455 1/2/3 Standards (Per Pack 100 Nos) , Autoclavable Disposable Bags For Sterilization (Per Pack 100 Nos) , Ph Tablets (Ph 2-8) , Aluminium Foil: Laboratory-Grade Ultra-Clean Foil.Should Be Strong And Puncture-Resistant , 3 Ply Laboratory Tissue Paper Roll (Dimension 9"X11") , Laboratory Blotting Papers (Dimension 46 X 57 Cm 238 Grade ). Should Be Thick And Have Quick Aspiration. Should Have Uniform Structure And Strength (Weight And Thickness).Should Be Of Ultrapure Composition And Have A Smooth Surface. , Cryotags For 0.5Ml Tubes (100/Pack) , Cryotags For 1.5Ml Tubes (100/Pack) , Cryotags For 2Mltubes (100/Pack) , Kim Wipes -4.5 X 8 Inch (280/Pack) , Kim Wipes -15 X 17 Inch (280/Pack) , Ethidium Bromide (0.5Ug/Ml) ( 10Ml) , Countess Ii Automated Cell Counter Compatiblecell Counting Chamber Slides (Each Slide With Two Counting Chamber- 10?L Samle And 10?L Trypanblue)(Per Pack - 50 Slide) , Skin Punch Biopsy Needle (2Mm/3Mm) , Disposable Biopsy Gun A Disposable Core Needle Fully Automatic Biopsy Device With High Speed Action Ensuring Quality Core Samples With Minimal Displacement Of Tissue. Should Have 1. 2.2 Cm Penetration Depth With 18G Needle Thickness And 16 Cm Needle Length 2. One Hand Cocking Mechanism And Non-Roll Handle Design Leading To Convenience And Enhanced Control 3. Sleek And Functional Ergonomic Design For Easier Manipulation And Improved Control 4. Dual Trigger Mechanism Allowing Flexibility For The Physician To Use Different Biopsy Techniques As Per Convenience 5. Angled Sample Notch For Enhanced Needle Action 6.Color Coding For Easy And Accurate Gauge Identification , Disposable Biopsy Gun A Disposable Core Needle Fully Automatic Biopsy Device With High Speed Action Ensuring Quality Core Samples With Minimal Displacement Of Tissue. Should Have 1. 2.2 Cm Penetration Depth With 18G Needle Thickness And 20 Cm Needle Length 2. One Hand Cocking Mechanism And Non-Roll Handle Design Leading To Convenience And Enhanced Control 3. Sleek And Functional Ergonomic Design For Easier Manipulation And Improved Control 4. Dual Trigger Mechanism Allowing Flexibility For The Physician To Use Different Biopsy Techniques As Per Convenience 5. Angled Sample Notch For Enhanced Needle Action 6.Color Coding For Easy And Accurate Gauge Identification , Glasswares , Screw Capped Autoclavble Glass Bottles, 1000Ml (Schott Duran/Borosil) , Screw Capped Autoclavable Glass Bottles, 500Ml (Schott Duran/Borosil) , Screw Capped Autoclavble Glass Bottles, 250Ml (Schott Duran/Borosil) , Screw Capped Autoclavble Glass Bottles, 100 Ml (Schott Duran/Borosil) , Equipment (Less Than Rs.100,000/-) Autoclavable Adjustable Volume Single Channel Research Pipettes With Carousel Specification For Pipettes In Sl No. 01 To 06 • Fully Autoclavable Precision Micropipette • Four-Digit Volume Display With Magnifying Space • Quick Lock To Enable Easy Cleaning And Maintenance • Secondary Adjustment To Support For Accurate Pipetting • Precision & Accuracy > 98% • Spring-Loaded Tip Cone • One-Button Operation With Reduced Operating Effort And Active Aerosol Reduction • Lower Operating Forces For Aspiration/Dispensing/Tip Ejection To Limit Strain On The User. • Should Be A Mechanical Air-Cushion Pipette With A Standard 3-Button Operation (One Operating Element Forvolume Selection, One For Pipetting, And One For Tip Ejection) • Should Be Ideal For Accurate, Easy, And Ergonomic Manual Pipetting Of Aqueous Solutions • Should Be Of Premium Material To Ensure A High Uv And Chemical Resistance Each Item Should Consist Of A Pipette, Operating Manual, Certificate, Adjustment Tool (Allen Key With Handle), Adjustment Seal For Temporary Adjustment (X5), Grease For Pipettes, Locking Ring (To Prevent Spring Action) Pipette Performance Certificate Should Be Provided Along With The Pipette Or Should Be Easily Downloadable Certification - Us Fda/Ce/Iso Warranty - 1 Year , 01. Adjustable Volume Single Channel Research Pipette: 100-1000?L Random Measurement Error Should Be: 100 ?L: ± 0.6%; ± 0.6 ?L 500 ?L: ± 0.2%; ± 1 ?L 1000 ?L: ± 0.2%; ± 2 ?L Systematic Measurement Error Should Be: 100 ?L: ± 3%; ± 3 ?L 500 ?L: ± 1%; ± 5 ?L 1000 ?L: ± 0.6%; ± 6 ?L , 02. Adjustable Volume Single Channel Research Pipette: 20-200?L Random Measurement Error Should Be: 20 ?L: ± 0.7%; ± 0.14 ?L 100 ?L: ± 0.3%; ± 0.3 ?L 200 ?L: ± 0.2%; ± 0.4 ?L Systematic Measurement Error Should Be: 20 ?L: ± 2.5%; ± 0.5 ?L 100 ?L: ± 1%; ± 1 ?L 200 ?L: ± 0.6%; ± 1.2 ?L , 03. Adjustable Volume Single Channel Research Pipette: 10-100?L Random Measurement Error Should Be: 10 ?L: ± 1%; ± 0.1 ?L 50 ?L: ± 0.3%; ± 0.15 ?L 100 ?L: ± 0.2%; ± 0.2 ?L Systematic Measurement Error Should Be: 10 ?L: ± 3%; ± 0.3 ?L 50 ?L: ± 1%; ± 0.5 ?L 100 ?L: ± 0.8%; ± 0.8 ?L , 04. Adjustable Volume Single Channel Research Pipette: 2-20?L Random Measurement Error Should Be: 2 ?L: ± 1.5%; ± 0.03 ?L 10 ?L: ± 0.6%; ± 0.06 ?L 20 ?L: ± 0.3%; ± 0.06 ?L Systematic Measurement Error Should Be: 2 ?L: ± 5%; ± 0.1 ?L 10 ?L: ± 1.2%; ± 0.12 ?L 20 ?L: ± 1%; ± 0.2 ?L , 05. Adjustable Volume Single Channel Research Pipette: 0.5-10?L Random Measurement Error Should Be : 0.5 ?L: ± 5%; ± 0.025 ?L 1 ?L: ± 1.8%; ± 0.018 ?L 5 ?L: ± 0.8%; ± 0.04 ?L 10 ?L: ± 0.4%; ± 0.04 ?L Systematic Measurement Error Should Be : 0.5 ?L: ± 8%; ± 0.04 ?L 1 ?L: ± 2.5%; ± 0.025 ?L 5 ?L: ± 1.5%; ± 0.075 ?L 10 ?L: ± 1%; ± 0.1 ?L , 06. Adjustable Volume Single Channel Research Pipette: 0.1-2.5?L Random Measurement Error Should Be : 0.1 ?L: ± 12%; ± 0.012 ?L 0.25 ?L: ± 6%; ± 0.015 ?L 1.25 ?L: ± 1.5%; ± 0.01875 ?L 2.5 ?L: ± 0.7%; ± 0.0175 ?L Systematic Measurement Error Should Be : 0.1 ?L: ± 48%; ± 0.048 ?L 0.25 ?L: ± 12%; ± 0.03 ?L 1.25 ?L: ± 2.5%; ± 0.031 ?L 2.5 ?L: ± 1.4%; ± 0.035 ?L , 07. Pipette Carousel Should Be Compatible And Will Be Procured From The Same Manufacturer Of Pippets Listed In Sl No 01 To 06: Specification For Pipette Carousel • Should Carry/Hold Upto Six Single Or Multi-Channel Pipettes • Should Include Rotatable Stand Design • Should Have A Robust Design That Securely Holds And Protects Pipettes • Should Be Easy To Transport From Bench To Bench , Multichannel Pipettewith Three-Digit Display With Display Window Facing User With 3 Button Operations 1. Pipetting Type: Air-Cushion System 2. No. Of Channels: 8 3. Volume Range: 10-100?L 4. Operating Mode: Mechanical 5. Autoclavable: Yes 6. Spring-Loaded Tip Cone: Yes 7. Volume Range With Increments Of0.01 ?L 8. A Pipette Performance Certificate Should Be Provided Along With The Pipette Or Should Be Easily Downloadable 9.Should Come With Standard 3-Button Operation (One Operating Element For Volume Selection, One For Pipetting, And One For Tip Ejection) 10. Should Be Ideal For Accurate, Easy, And Ergonomic Manual Pipetting Of Aqueous Solutions 11. Should Be Of Premium Material To Ensure A High Uv And Chemical Resistance 12. Random Measurement Error Should Be : 10 ?L: ± 2%; ± 0.2 ?L 50 ?L: ± 0.8%; ± 0.4 ?L 100 ?L: ± 0.3%; ± 0.3 ?L 13. Systematic Measurement Error Should Be : 10 ?L: ± 3%; ± 0.3 ?L 50 ?L: ± 1%; ± 0.5 ?L 100 ?L: ± 0.8%; ± 0.8 ?L 14. The Box Should Consist Of A Pipette, Operating Manual, Certificate, Adjustment Tool (Allen Key With Handle), Adjustment Seal For Temporary Adjustment (X5), Grease For Pipettes, Locking Clip (To Prevent Spring Action) (X2), O-Ring Tool Certification - Us Fda/Ce/Iso Warranty - 1 Year , Multichannel Pipette With Three-Digit Display With Display Window Facing User With 3 Button Operations 1. Pipetting Type: Air-Cushion System 2. No. Of Channels: 83. Volume Range: 30-300?L 4. Operating Mode: Mechanical 5. Autoclavable: Yes 6. Spring-Loaded Tip Cone: Yes 7. Volume Range With Increments Of0.01 ?L 8. Apipette Performance Certificate Should Be Provided Along With The Instrument Or Should Be Easily Downloadable 9. Should Come With Standard 3-Button Operation (One Operating Element For Volume Selection, One For Pipetting, And One For Tip Ejection) 10. Should Be Ideal For Accurate, Easy, And Ergonomic Manual Pipetting Of Aqueous Solutions 11. Should Be Of Premium Material To Ensure A High Uv And Chemical Resistance 12. Random Measurement Error Should Be : 30 ?L: ± 1%; ± 0.3 ?L 150 ?L: ± 0.5%; ± 0.75 ?L 300 ?L: ± 0.3%; ± 0.9 ?L 13. Systematic Measurement Error Should Be : 30 ?L: ± 3%; ± 0.9 ?L 150 ?L: ± 1%; ± 1.5 ?L 300 ?L: ± 0.6%; ± 1.8 ?L Certification - Us Fda/Ce/Iso Warranty - 1 Year , Multichannel Pipettewith Three Digit Display With Display Window Facing User With 3 Button Operations 1. Pipetting Type: Air-Cushion System 2. No. Of Channels: 12 3. Volume Range: 10-100?L 4. Operating Mode: Mechanical 5. Autoclavable: Yes 6. Spring-Loaded Tip Cone: Yes 7. Volume Range With Increments Of0.01 ?L 8. A Pipette Performance Certificate Should Be Provided Along With The Instrument Or Should Be Easily Downloadable 9. Should Come With Standard 3-Button Operation (One Operating Element For Volume Selection, One For Pipetting, And One For Tip Ejection) 10. Should Be Ideal For Accurate, Easy, And Ergonomic Manual Pipetting Of Aqueous Solutions 11. Should Be Of Premium Material To Ensure A High Uv And Chemical Resistance 12. Random Measurement Error Should Be : 10 ?L: ± 2%; ± 0.2 ?L 50 ?L: ± 0.8%; ± 0.4 ?L 100 ?L: ± 0.3%; ± 0.3 ?L 13. Systematic Measurement Error Should Be : 10 ?L: ± 3%; ± 0.3 ?L 50 ?L: ± 1%; ± 0.5 ?L 100 ?L: ± 0.8%; ± 0.8 ?L 14. The Box Should Consist Of A Pipette, Operating Manual, Certificate, Adjustment Tool (Allen Key With Handle), Adjustment Seal For Temporary Adjustment (X5), Grease For Pipettes, Locking Clip (To Prevent Spring Action) (X2), O-Ring Tool Certification - Us Fda/Ce/Iso Warranty - 1 Year , Multichannel Pipettewith Three-Digit Display With Display Window Facing User With 3 Button Operations 1. Pipetting Type: Air-Cushion System 2. No. Of Channels: 123. Volume Range: 30-300?L 4. Operating Mode: Mechanical 5. Autoclavable: Yes6. Spring-Loaded Tip Cone: Yes 7. Volume Range With Increments Of0.01 ?L 8. A Pipette Performance Certificate Should Be Provided Along With The Instrument Or Should Be Easily Downloadable 9. Should Come With Standard 3-Button Operation (One Operating Element For Volume Selection, One For Pipetting, And One For Tip Ejection) 10. Should Be Ideal For Accurate, Easy, And Ergonomic Manual Pipetting Of Aqueous Solutions 11. Should Be Of Premium Material To Ensure A High Uv And Chemical Resistance 12. Random Measurement Error Should Be : 30 ?L: ± 1%; ± 0.3 ?L 150 ?L: ± 0.5%; ± 0.75 ?L 300 ?L: ± 0.3%; ± 0.9 ?L 13. Systematic Measurement Error Should Be : 30 ?L: ± 3%; ± 0.9 ?L 150 ?L: ± 1%; ± 1.5 ?L 300 ?L: ± 0.6%; ± 1.8 ?L 14. The Box Should Consist Of A Pipette, Operating Manual, Certificate, Adjustment Tool (Allen Key With Handle), Adjustment Seal For Temporary Adjustment (X5), Grease For Pipettes, Locking Clip (To Prevent Spring Action) (X2), O-Ring Tool Certification - Us Fda/Ce/Iso Warranty - 1 Year , Tabletop Pulse Oximeter 1. High Resolution 6.4 Color Leddisplay 2.Spo2 Range: 1% To 100% 3. Pulse Rate - 20 To 250 Beats Per Minute (Bpm) 4. Saturation -For Adult-70% To 100% ± 2 Digits, For Neonates- 70% To 100% ± 2 Digits 4. Graded And Color Coded Alarms (2 Stages) 5. Display/Indicators - Pulse Search, Audible Alarms Silenced Or Off, Interference Indicator, Battery Charging, And Satseconds Alarm Management Clock, Pleth Waveform 6.Critical Alarm For Audible And Visual Alarms For High/Low Saturation And Pulse Rate, Low Battery, Sensor Off, And Sensor Disconnect. 7.24 Hrs Graphical Trend With Zoom Facility (Non-Volitive) Adn Should Be Online Sp)@ & Pr Graphical Trends. 8. Suitable For Adult And Paediatric Applications 9. Rechargeable Battery Backup With A Minimum Of Two Hours Using A New, Fully Charged Battery With No Alarms; Optional 10-Hour Battery. 10. Should Be Shockproof And Noise Level In Db - 40 11. Conformity To Manufactures Certification - Iso 9001 & Iso 13485 12 10. Includes: (Per Set) 1. Main Unit With Power Cable, Battery, Adapter Plate,Wall Mount Arm And Channel, Roll Stand,And Carrying Case, 2. Spo2 Extension Cable 3. Reusable Spo2 Dura Sensor (Nellcore) - Adult - 2 Nos, 4. Reusable Spo2 Dura Sensor (Nellcore) - Paediatric - 1 No 5. Warranty - 3 Years 6.Certification - Us Fda/Ce/Iso , Precision Balance Specification : •Maximum Capacity-220 G •Readability | Scale Interval (D) - 0.1 Mg •Repeatability@5% Load - 0.08 Mg •Repeatability @ Maximum Load - 0.1 •Linearity ± -0.2 Mg •Sensitivity Drift Between + 10°C And + 30°C - 1.5 Ppm/K •Settling Time -2 S •Minimum Weight (Usp, 0.1%, Typical) - 0.16 G •Caliberation - Internal Isocal •Typical Measurement Time - = 2.0S •Typical Stabilization Time - = 1.5S •Adjustment -Internal / Profact Advanced •Interfaces -Ethernet (Lan),Rs232 (Integrated/Optional),Usb •Display - 7" Colour Tft Touchscreen •Weighing Pan Dimensions (Wxd) -90 Mm X 90 Mm •Dimensions (Hxwxd)-368 Mm X 214 Mm X 411 Mm •Terminal Size-7 Inch •Should Have Glass Level Indicator With Air Bubble For Centering •Protection : Chemical Resistant Finish Of The Top Housing; Glass Parts Of The Draft Shield Should Be Coated To Reduce Electrostatic Influences; Should Provide In-Use Cover And Dust Cover For Balances With Draft Shield •Certification - Ce /Iso •Warranty -2 Years , Digital Vortex Mixer • Efficient Mixing With Minimal Vibration • Microprocessor Controls • Speed Range: 120 To 3500Rpm • Vibration Orbit: 3.5 To 5Mm • Operating Modes: Touch (Or) Continuous • Controls: 3-Way Power Switch; Speed Knob: Variable 1–10 Dial Marks • Cup Head For Single Tubes And Platform Suitable For Beakers, Flasks Andmicroplates. • Can Be Used At 4 To 40 °C (85% Relative Humidity, Non Condensing), In An Incubator Or Cold Room • Overall Dimensions (Lxwxh): 4.8 X 6.8 X 4.8 In • Electrical (50/60Hz): 120 Volts, 1.2 Amps,150 Watts • Weight: Around 5 Kg • Led Display For Time/Speed, Up/Down Keys For Set-Point Control Warranty -2 Years Certification - Ce/Iso , Digital Magnetic Stirrer With Hot Plate • Stirring Speed Should Be From 100 Rpm To 1500 Rpm. • Maximum Stirring Volume – 6 Litre. • Plate Temperature Regulation Range - +30°C To +550°C. • Temperature Uniformity On The Plate - ±3°C. • Working Plate Heating Time To Reach +300°C – 15 Min. • Maximum Continuous Operation Time – 24 Hour. • Dimension Of The Working Plate - 160Cm ×160Cm×10Cm. • Weight – 3Kg And Blinks Until Set Temperature Is Reached •Digital Led Temperature Display Is Adjustable In 5 °C Increments. •Microprocessor Controlled For Consistent And Repeatable Temperature Setting. •A Separate Temperature Sensor To Provide Power Cut Off If Unit Overheats Ie Automatic Over-Temperature Protection • Working Surface Material – Stainless Steel,Pyroceram Glassor Ceramic That Should Be Chemically Resistant To Acid And Alkali And Should Be Should Be Extremely Durable • Control For Both The Hotplate And Stirrer Should Be Provided With Suitable Indicators. • Exact Temperature Setting Via Digital Display (Led), Digital Error Code Display, And Elevated Control Panel For Protection Against Leaking Liquids •Small Footprint And Low Profile • 230V, 50/60Hz • Warranty – 1 Year • Certification - Ce/Iso , Digital Platform/Gel Rocker • Mounting- Bench Top • Controller - Digital •Should Provide 3-Dimensional Motion For All Applications • Type Of Motor – Brushless Dc • Maximum Load Capacity: Upto 5 Kg • Speed Range In Rpm - 1-70Rpm • Timer Range In Minutes – 99 • Easily Adjustable Rocking Angle: 1 Degree- 15 Degree • Should Have Compact Counter Balance Drive Mechanism To Ensure Stability • Platform Size In Length X Width In Mm X Mm - 380 X 380Mm • Display – Lcd, Display Parameters -Speed With Preset Facility •The Tilt Angle And Speed Should Be Adjustable For Gentle And Thorough Mixing In Gel Trays, Boxes, And Other Flat Vessels •Should Have A Compact Counterbalance Drive Mechanism To Ensure Stability •Should Have Autoclavable Flat Mats • Should Have Maintenance-Free Brushless Motors; • Should Be Safe For Use In Cold Rooms And Incubators. • Should Have Auto Restart After Power Resumption Power Supply - 220 Volts, 50Hz, Single Phase Certification – Iso/ Ce Warranty -2 Years , Laboratory Coolers • Benchtop Coolers That Can Hold Standard Tube And Vial Sizes In Various Matrixes And Featuring Labeled Grids For Fast Identification. • Inserts Compatible For0.2 To 2Ml Tubes • Should Be Molded From Durable Polycarbonate With Locking Handle For Long-Term Use And Filled With Non-Toxic Freezable Gel • Holding Temperature -20°C For 60 Mins • Stackable To Save Space • Certification – Iso/ Ce Warranty - 1 Years , Automatic Pipette Controller • A Light, Ergonomic, Motorized Pipet Controller Designed For Use With Glass And Plastic Serological Pipets From 0.5 To 100Ml • Autoclavable Pipette Cone • Single Handed Operation With Variable Motor Speed • Separate Aspirate And Dispense Speed Controls For Precise Pipetting • Feature A Heavy-Duty Rechargeable Lithium-Ion Battery • Up To 12 Hours Of Continuous Operation Without Recharge • Direct Exhaust Of Liquid Vapour; With Safety Valve & Dual Hydrophilic, Hydrophobic Filter To Prevent Cross-Contamination. • Replaceable Membrane Filter To Protect Device From Contaminants Being Drawn Into Pipet • Lcd Display For Continuous Visualization Of Speed, Modes, And Battery Status • Can Be Used While It Is Charging • Certification – Iso/ Ce Warranty - 2 Years , Digitalph Meter • Perform Easy Measurements And Customizable Four-Meter Channels With Interchangeable Modules • Perform Up To A 6 Point Ph Calibration, Log Up To 2000 Data Point Sets With Time/Date Stamp And Easily Transfer Calibration And Data Logs Via Usb Or Rs232 To A Printer Or Computer • Lcd Display • Temperature Range:-5°C To +105°C; Temperature Accuracy: ±0.1°C; Temperature Resolution 0.1°C • Ph Range: -2 To 20; Ph Accuracy: ±0.002; Ph Resolution: 0.1 • Have Set Point Alarm, High/Low Limit Alarm, Calibration Due Alarm • Numeric Keypads With Menu-Specific Function Keys And Dual Purpose Scroll/Shortcut Keys • Should Come With Ph Electrode Probe, Electrode Stand, 100-240V Universal Power Adapter And Computer Cable • Dimensions (W X L X H), Cm: 28 X 24 X 10; Weight 1Kg • Multi Language Operational Instructions • Certification – Iso/ Ce •Warranty 3 Years , Digital Laboratory Timer • Timing Capacity: 99 Hours, 59 Minutes, 59 Seconds • Count Direction: Up And Down • Clock: Yes • Number Of Channels: 3 • Resolution: 1 Sec • Accuracy: ±0.001% • Alarm: 1 Minute Continous Beep And Visual • Display: Three-Line Lcd, 3/8" H • Certifications: Nist-Traceable • Height (In) - 3, Depth (In) - 1, Width (In) - 3 1/4 • Certification – Iso/ Ce • Warranty - 1 Year , Digital Microplate Shaker With Standard Accessories Should Be Supplied - Compact, Universal Small Shaker Suitable For Shaking All Small Vessels And Microtiter Plates, Wide Range Of Attachments And Attachment Detection, Digital Display Of Speed And Time, Ideal For Use Under Controlled Conditions (4-40° C), Quick And Vibration-Free Operation. • Type Of Movement - Orbital • Orbit Diameter- 2Mm To 3Mm • Speed Range - 300 - 1800 Rpm • Motor Type- Brushless Dc Motor • Precise Speed Control - - ±2% • Maximum Load Up To - 4 Kgs • Timer - Yes • Time Setting Range - Upto 99 Min • Display: Digital Display Of Led (Speed And Time) • Operating Mode - Timer And Continuous Operation • Touch Function - Yes • Number Of Microtiter Plates - 4 • Accessories: 20X 1.5/2.0Ml Microtubes And Replaceable Clampsto Use Different Types Of Standard Microplates • Power - 230V • Certification - Us Fda/Ce/Iso • Warranty- 2 Years , Automatic Washer With Standard Accessories A Complete System With Wash Bottles And Buffers Capable Of Washing Plates With Magnetic And Non-Magnetic Assays For Increased Automation, Higher Throughput, And Better Reproducibility.Magnetic Washer With Ultrasonic Cleaning Incorporated • Microplate Types- 96 Or 384 Well Low Profile, And Standard Height, Solid And Filter Bottom. • Volume Range - 25-3,000 ?L/Well (192-Pin Manifold) 50-3,000 ?L/Well (96-Pin Manifold) •Magnetic Field - Flat Magnetic Design 6800, Ring - 7094 • Number Of Dispensing Channels - 8 •Residual Volume Magnetic Wash- = 2 ?L/Well (96- & 384-Well Plates, Using 96-Tube Manifold For 96 Wells @300 ?L; 192-Tube For 384 Wells@100 ?L) •Dispensing Accuracy- =3%Dispensing Uniformity - Cv =4% Over The Plate •Wash Speed - 96-Wells, 300 ?L/Well, 3 Cycles; <30 Seconds 384-Wells, 100 ?L/Well, 3 Cycles: <80 Seconds •Flow Rates - Adjustable Rates, High Flow To Low Flow; Optimized Rates For Cell Assays •Vacuum Filtration - Selectable, Range From -38 Mmhg To -506 Mmhg•Vacuum Filtration Time Range: 5 To 999 Seconds •Dispense Precision - <3% Cv: 300 ?L/Well (96-Well Washing) <4% Cv: 80 ?L/Well (384-Well Washing) •Should Provide Supply Bottle- 4 L Or 10 L •Should Provide Waste Bottles - 4L, 10L And 20L Waste Bottlesdirect Drain Should Be Available •Should Have High Resolution Led Backlit Touch Screen With Graphical Color Display •Certification - Us Fda/Ce/Iso •Warranty - 2 Years , Vacuum Manifold For 96 Well Filter Plates Suitable For Xmap Based Assays • For Vacuum Filtration Of Multiwell Filter Plates • Vacuum Manifold Should Include Manifold Base, Standard Ring With Gaskets, Support Grid, All Tubing, Valves And Pressure Gauge • Should Have On/Off Control • Should Have A Vacuum Pressure Indicator • Should Include A Gauge To Know The Vacuum Level Applied To The Filter Plate • Should Allow Vacuum Level Adjustments Via A Set Point Knob • Base: Hdpe• Standard Well Ring: Nylon • Deep Well Ring: Hdpe • Gaskets: Epdm • Tubing: Fep-Lined Like Tygon® • Support Grid: Stainless Steel • On/Off Valve: Polypropylene W/ Epdm Seal • Vacuum Control Valve: Brass Socket, Steel Case • Vacuum Gauge: Steel • Should Include A Compatible Vacuum Pump And Vacuum Trap• Should Have Configurations For Deep Well Or Standard Receiver Plates • Ansi/Sbs Compliant Footprintfor Easy Robotic Deck Integration • Should Be Solvent-Resistant Certitification - Us Fda/Ce/Iso Waarranty - 2 Years , Bath Sonicator 3L With Digital Timer And Heater For Probe Cleaning • Ultrasonic Cleaner With Multiple Power Settings To Handle Both Normal And Delicate Cleaning • Should Have A Degas Mode For Improved Cleaning Efficiency • Should Have Adjustable Heating Tunable From 20 Deg C To 80 Deg C For Deeper Cleaning • Should Come With Stainless Steel Tank And Basket • Should Have Timed Operation From 1-30 Minutes • Tank Capacity: 3L • Material: Stainless Steel Ss304 • Ultrasonic Frequency Output: 40000 Hz • Power: 240 Volts Alternating Current • Display: Led Display For Time And Temperature • Control: Easy Push Button • Sturdy Rubber Feet To Prevent Movement While In Use • Heater Power - 200 W Digital Heating Certification : Us Fda/Ce/Iso Warranty - 2 Years
|