Tender For Renovation Up Gradation Of Sos Mess Building Of 29 Bn Bsf (Now 116 Bn Bsf) Mamdot Under Shq Bsf Ferozepur (Sh Ei Fans And Accessories); 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required GROUP-B 2 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required Group B 3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required i) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 4 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required ii) 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 5 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required 6 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required 7 Supplying and drawing following sizes of FRLS PVC insulated copper condutor, single core cable in the existing surface/ recessed steel/ PVC Conduit as required. i) 3 x 1.5 sqmm 8 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. i) 20 mm 9 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. ii) 25 mm 10 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. iii) 50 mm 11 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required 12 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required i) 8 Module (125mmX125mm) 13 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required ii) 12 Module (200mmX150mm) 14 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required ii) 5/6 amps switch 15 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required iii) 3 pin 5/6 A socket outlet 16 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required 17 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required 18 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required 19 Supplying and fixing brass batten/ angle holder including connection etc. as required 20 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) i) 4 way (4 + 12), Double door 21 Supplying and fixing 5 A to 32 A rating 240/415 volts,"C" curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. i) Single pole 22 Supplying and fixing 5 A to 32 A rating 240/415 volts,"C" curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. ii) Triple Pole and neutral 23 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 24 Supplying,Installation, testing and commissioning of heavy duty exhaust fan, metalic body 230V, 380 mmsweep,single phase including making the hole to suit the size of the above fan, making good the damage i/c P/F louver and shutter complete with frame for exhaust fan of size connections,testing and commissioning etc as required. 25 Supplying and fixing of 250 mm sweep, 1250-1300 RPM non metallic exhaust fan suitable for single phase, 50 Hz, 230 volt AC supply in existing opening including connection etc as required. of make Orient (ventilator dx) or equivalent make of Havells/Bajaj/CG. 26 Installation, testing and commissioning of LED batten tube light complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 27 Supply, installation, testing and commissioning of 10 watt LED tube fittings comprises of extruded channel in thermally conductive material ,high translucent serrated milky white diffusers used to get glare free and smooth light distribution, efficiency :100lm/w and LED tube directly on ceiling/ wallincluding connection with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc as required. 28 Supply, installation, testing and commissioning of 09 watt LED ceiling light panel aesthetically designed recessed mounted panel in a light weight plastic including body surface ring of suitable size and same make directly on ceiling including connection with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc as required. 29 Supply, installation, testing and commissioning of 22 watt LED ceiling light panel aesthetically designed recessed mounted panel in a light weight plastic including body surface ring of suitable size and same make directly on ceiling including connection with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc as required. 30 Installation, testing and commissioning of LED flood light complete with all accessories directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 31 Earthingwith G.I. earth pipe4.5mtr long x 40mm dia including accessories and providing masonary enclosure with cover platehaving locking arrangement and watering pipe etc. withcharcoalor coke and salt complete as required. 32 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 33 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required
|