Tender For Provision Of Otm For Ncs(E) Faculty At Tilakwadi At Ats Belagavi; 2 GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to XII are prepriced by MES under Ser No. 1 to 12. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. 3 Lumpsum price worked out by the contractor for “Building or Works” as listed in Schedule ‘A’Part–I 4 Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’Part–II 5 Lumpsum price worked out by the contractor for “Internal Electric Supply" as listed in Schedule ‘A’Part–III 6 Lumpsum price worked out by the contractor for “Road / Path / Culvert " as listed in Schedule ‘A’ Part - IV . 7 Lumpsum price worked out by the contractor for "Area Drainage" as listed in Schedule ‘A’ Part - V . 8 Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part – VI. 9 Lumpsum price worked out by the contractor for “Chain link fencing and Gate” as listed in Schedule ‘A’ Part – VII. 10 Lumpsum price worked out by the contractor for “Rain water Harvesting” as listed in Schedule ‘A’ Part – VIII. 11 Lumpsum price worked out by the contractor for “External Water Supply” as listed in Schedule ‘A’ Part – IX 12 Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part – X 13 Lumpsum price worked out by the contractor for “Solar Water Heater” as listed in Schedule ‘A’ Part – XI 14 Lumpsum price worked out by the contractor for "Refrigeration / Deep Freezer / Water Cooler / Air Conditioning” as listed in Schedule ‘A’ Part – XII 15 Sch "A" Part - IA : BUILDINGS OR WORKSDesign and Construction of 300NCs and Cook house & Dinning Hall building in 4 storey (Ground+3 storey)framed construction with permanent specifications in RCC of grade as per structural drawings, PCC solid block masonry walls, ATT, APP WPT, earthquake resistance as per latest IS and Green building norms with GRIHA 3 star ratingsetc complete all as specified and as shown on drawings. 16 Design and Construction of Admin and class room building in 4 storey (Ground+3 storey)framed construction with permanent specifications in RCC of grade as per structural drawings, PCC solid block masonry walls, ATT, APP WPT, earthquake resistance as per latest ISand Green building norms with GRIHA 3 star ratings etc complete all as specified and as shown on drawings. 17 Design and Construction of single living accommodation building for 07 Sgt in single storey framed construction with permanent specifications in RCC of grade as per structural drawings, PCC solid block masonry walls, ATT, APP WPT, earthquake resistance as per latest ISand Green building norms with GRIHA 3 star ratings etc complete all as specified and as shown on drawings. 18 Design and Construction of Sub station building in single storey framed construction with permanent specifications in RCC of grade as per structural drawings, PCC solid block masonry walls, ATT, APP WPT, earthquake resistance as per latest IS etc complete all as specified and as shown on drawings. 19 Design and Construction of parking shed for 10 Scooters in steel truss with Galvalume sheet Roofing, PCC flooring as per latest IS etc complete all as specified and as shown on drawings. 20 Design and Construction of parking shed for 5 Cars in Steel truss with Galvalume sheet Roofing, PCC flooring as per latest IS etc complete all as specified and as shown on drawings. 21 Sch "A" Part - XIII : Fittings / Fixtures & Misc items. INTERNAL WATER SUPPLYS&F 15mm bore angle cock cast copper alloy fancy type chromium plated for PPR pipe complete all as specified and as directed. 22 S&F 15mm bore, CP Two way Bib tap, cast copper alloy, chromium plated, fancy type, screwed down for iron pipe complete all as specified by the Engineer-in-Charge. 23 INTERNAL ELECTRIC SUPPLY Supply and fix Reading in bed side light 3/5 watt white with this collection of adjustable LED bedside lights ,220 Volts,Total 150 Lumens,PF > 0.95, CRI > 80 colour temperature 2700 to 6500K, high voltage protection, easy installation clips for user-friendly installation,AC decorative box type with driver, holder including retrofitLED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. 24 Supply and fix VTPN distribution boards shall be mounting recessed type. Enclosed 1.6mm thickness dust and vermin proof protection class IP-43 & IK 09 as specified in IS 732:2019, Double door suitable for mounting MCB with a minimum 200 Amps rating bus bar VTPN 08 way.conforming to IEC61439-3 with test reports etc complete in all respect all as specified and as directed by engineer in charge. 25 Supply and fix Modular TV Socket, one module etc complete in all respect all as specified and as directed by engineer in charge . 26 Material and labour for TV Wiring with unarmoured coaxial cable,RG-11in concealedwith PVC Conduit 25 mm diaetc complete in all respect all as specified and as directed by engineer in charge. 27 Supply and fix Modular Telephone socket, RJ-11, one module etc complete in all respect all as specified and as directed by engineer in charge. 28 Material and labour for Telephone Wiring with unarmoured Solid annealed bare copper industrial cablein concealed of size 0.5 mm, 3 pair with PVC Conduit 25 mm diaetc complete in all respect all as specified and as directed by engineer in charge. 29 EXTERNAL WATER SUPPLYSupply and lay 150mmdiaductile iron pipe, spigot and socketof class K-9 suitablefor push onrubber joints including rubber joints complete all as specified and as directed. 30 Supply and lay 100mmdiaductile iron pipe, spigot and socketof class K-9 suitablefor push onrubber joints including rubber joints complete all as specified and as directed. 31 Supply and fix foot valve confirming to IS-4038 of size 100 mm dia all as specified and as directed. 32 Supply, install, testing and commissioning of Monoblock pump sets of capacity 15 HP, threephase, 415 Volt suitable for 80X65mmdiapipe for suction and delivery head range40 to 45 Mtr, discharge 10.00 to 15.00 LPS including provision of suitable PCC foundation for fixing of Pump Sets and provision PVCcopper Cables3 X 10 sqmm incl PVC Conduits 25mm fromstarter to Motor complete all as specified and directed. Note: 1. Standard test certificate for pump and motor has to be submitted by the contractor cost for the same is deemed to be included in thequoted rate. 2. Test results like routine test/Pump performance test/Motor performance/material of construction etc shall besubmitted by the contactorafter installing the pump sets cost for the sameis deemed to be included in the quoted rate. 33 M&L forConstruction of brick masonry valve pit chamber of inner dimension 100x100x100cm suitable for sluice valves upto 100mm size, with PCC 1:4:8 type D-2 for foundation, brick work in cement mortar 1:6, rendering in cement mortar 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, incl necessary earth work, including MS sheet cover of thickness 3.15mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement complete all as specified and directed. 34 Supply , install, testing and commissioning of LT Feeder pillar Box AC 415 V , 50 HZ 3 Phase 4 wire of suitable size to accommodating the following accessoriestotally enclosed self supporting structure / cubicle , fully compartmentalized type , weather proof , vermin proof indoor type made out of 2.00 mm thick MS sheet protection IP 54 , suitable for outdoor use , with bottom cable entry with suitable cable glands structure with angle iron frame work with four legs grouted to PCC (1:2:4) type B1 , foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doorsfront and back side withsuitable locking arrangement , Provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated with 200A electricalgrade copper bus bar for phases and neutral complete with suitable digital type meters resin cast CTs ,CPRI approved type tested, internal wiring all includingthe following incoming complete all as specified and directed :- 35 (a) MCCB FP 63 Amps rating, 10 KA breaking capacity - 01 No. (Incoming)(b) MCCB TP 40 Amps rating, 10 KA - 2 ( outgoing )( 1W+1S/BY)(c) MCB SPN 6-32 Amps - 02 Nos,Curve "C" rated, 10KA Breaking capacity(d) MCB TP 6-32 Amps - 01 Nos,Curve "C" rated, 10KA Breaking capacity(e) Indicator lamp LED type - 3Nos (Set of 03)(f) Digital Metering Unit with ammeter, Voltmeter and Phase Indicator with Selector Switch - 03 Nos(g) FASD starter suitable for15 HP centrifugal pumpset -02 Nos 36 Supply, install, testing and commissioning of acoustic proof diesel engine driven generating set, fully wired, 415 Volts, AC, 3 phase 4 wire, 50Hz having capacity20 KVA(16KW) (CPCB - IV Norms) continuous rating at power factor 0.8 (lagging) as per IS-4722 and connections as per IE rules complete with liquid cooled 4 stroke Diesel engine with electric start with 12V DC battery, developing minimum 27 BHP at 1500 RPM under NTP prevailing at Sambra area, Belagavi considering derating factor and shall conform to IS:10000/150 3026/BS-5514 with provisions of 10% over loading for 1 hour for every 12 hours running with G2 class governingas per ISO 8528 Part V and all standard safety type, screen protected, revolving field, self excited, self regulated alternator conforming to BSEN-60034 with IP 23 protection complete with integrated AMF control panel with microprocessor based relays /MCCB /MCB"s/Contactors, multifunction meter showing KWH, KVA, PF, Amps, Volts, frequency, indicating lamps, 12 Volt battery charging unit including 12 Volts battery etc required as per latest standard engineering practices including sound proof canopy designed to meet MoEF/CPCB Norms of 75 dBA at 1mtr at 75% load, fabricated from CRCA sheet and a structural/sheet metal base frame, with high quality noise absorbent and fire retardant grade acoustic insulation material conformity to IS : 8183 and integrated fuel tank of capacity not less than minimum 8 hrs running fuel filling arrangement from inside duly painted after necessary pre treatment process complete all as specified and as directed. 37 Note: (i) The cost of PCC foundation as per the recommendation of OEM shall be deemed to be included in the quoted rate.(ii) Cost of fuel and other expenses for carrying out acceptance test of the DG set shall deemed to be included with the quoted rate. 38 Supply, Install, testing and commissioning of chemical (chlorine granules) chlorination dosing plant suitable to inject upto 25 LPH comprising of dosing pump coupled with three phase electric motor of capacity 0.5 HP, 1440 RPM, 415 V, 50 Hz, combined gear and motor assembly with agitator in one motor, agitator with SS sweep blade duly FRP coated, FRP tank of capacity 150 liters complete accessories to be mounted on MS fabricated frame including painting completely, drilling/taping and connected to the delivery line with suitable UPVC pipes and necessary fittings of dia 15 mm,PP NRV of 15mmdia including supply and fix starter wall mounted suitable for 0.5 HP motor three phase 415 V, 50 Hz with relay enclosed in sheet metal enclosure with push button switch for ON/OFF complete all as specified and directed. 39 Supply only HI strength calcium based chlorine granular (calcium Hypochlorite ) Ca (CIO)2 disinfectant (minimum chlorine content 65-70%) for water treatment more stable and stronger than bleaching powder and sodium hypochlorite packing in 45 /50Kgplastic drums complete all as specified and as directed. 40 EXTERNAL ELECTRIC SUPPLYSupply, Installation, testing and commissioning of 11 KV Oil immersed HT Isolator Switch Fuse unit, Indoor free floor standing type, totally enclosed, Manually operated, Metal clad contacts with ON-OFF Earth positions and with Automatic Trip from ON position to OFF position by Sticker Pin of HRC fuse blowing, designed for Load-braking & Fault rupturing capacityService voltage - 11 KV, 3 phase, 50 HzRated current - 200 AMpsNo of poles - Triple poleOverall dimension - 1040(L) x 870 (w) x 1700 (H) mmQty of Oil - 150 LtrsApprox total weight - 400 Kg 41 HRS Fuse - " BUSSMAN" make HRC fuse of rating suitable to protect 315 KVA TransformerTerminal ArrangementIncoming side- Trifurcating cable box suitable to connect XLPE cableOutgoing side - Three Nos terminal suitable to connect XLPE cableFittingsSpring operated manual closing mechanism with mechanical ON-OFF-EARTH positionMechanical knob for instantaneously releasing ON position to OFF position of switch Fuse unit - 01 NoAIr insulated Fuse chamber with locking facility - 01 NoEarthing Terminals - 02 NosRating Plate - 01 NoDrain Plug - 01 NoLifting lugs - 02 NosOil filling hole - 01 No 42 M&L for brick masonry transformer platform of size 1.5 mtr x 1.5 mtr with height 1.2 mtr above GLCement concrete in foundation of PCC (type D2), 1:4:8 (using 40 mm graded stone aggregate), PCC block masonry 1:3:6 in CM (1:4) moorum filling and consolidating inside the brick work , sub base concrete with PCC 1:3:6 and 100 mm thick top PCC 1:2:4 type B2 & 15 mm thick plaster on side walls in 1:4 CM including two coats of white wash complete all as specified and as directed. 43 Supply and fix PVC insulated FR round PVC sheathed flexible industrial cable 4 Sqmm, 3 core 1100 volts grade, for connecting street light and loop in loop out box complete all as specified and as directed. 44 Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed. 45 Supply and fix DWC Pipe IS-16205, size inner dia 143 mm, outer dia 160 mm for cable protection in wall/under ground laying of UG cables including SNAP-FIT Coupler and all fittings as required at sitecomplete all as specified and as directed by Engr-in-Charge. 46 Supply and fix DWC Pipe IS-16205, size inner dia 103 mm, outer dia 120 mm for cable protection in wall/under ground laying of UG cables including SNAP-FIT Coupler and all fittings as required at sitecomplete all as specified and as directed by Engr-in-Charge. 47 Supply and fix DWC Pipe IS-16205, size inner dia 63 mm, outer dia 75 mm for cable protection in wall/under ground laying of UG cables including SNAP-FIT Coupler and all fittings as required at sitecomplete all as specified and as directed by Engr-in-Charge. 48 Supply and fix DWC Pipe IS-16205, size inner dia 32 mm, outer dia 40 mm for cable protection in wall/under ground laying of UG cables including SNAP-FIT Coupler and all fittings as required at sitecomplete all as specified and as directed by Engr-in-Charge. 49 Supply , install, testing and commissioning of LT feeder pillar box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size for accommodating the following accessoriestotally enclosed self supporting structure / cubicle , fully compartmentalized type , suitable for outdoor use , with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick CRCA steel sheet with angle iron frame work and legs of ISA 50X50X5 mm , with four legs grouted to PCC (1:2:4) type B1 , foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter , changeover switch and MCCBs , hinged doors at front with suitable locking arrangement , Provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated, complete all as specified and directed:- (Main Panel) 50 BUSBAR :-(a)Electronic copper bus bar 600 Amps , supported on non hygroscopic fibres and brass screws for mounting -04 NosINCOMER(a) Supply and fixing MCCB of 4 poleof capacity 630 ampswith breaking capacity of 50 KA fixed thermal and fixed magnetic setting - 01 NosINDICATING DEVICES(a) Supply and fixing LED Indicating lamps for Main Supplyindicating R, Y, B - St of 3 - 01 No(b)Digital Metering Unit with ammeter, Voltmeter and Phase Indicator with Selector Switch - 01 NosOUTGOING FEEDERS(a) Supply and fixing MCCB of 3 poleof capacity 320 ampswith breaking capacity of 36 KA fixed thermal and fixed magnetic setting - 01 Nos (300 NC"s + Cook House )(b) Supply and fixing MCCB of 3 poleof capacity 200 ampswith breaking capacity of 25 KA fixed thermal and fixed magnetic setting - 01 Nos (Admin Bldg Panel )(c) Supply and fixing MCCB of 3 poleof capacity 40 ampswith breaking capacity of 10 KA fixed thermal and fixed magnetic setting - 03 Nos (01 No Pump House + 07 Sgts+ 01 No Extra)(d) Supply and fixing MCCB of 3 pole , 415volts of capacity 16ampswith breaking capacity of 10 KAfixed thermal and fixed magnetic setting - 04No (03 Street Light Circuits + 01 Extra) 51 Supply and fix loop in loop out box with transparent lid IP 66 weather proof of suitable sizefixed to pole/wall with suitable FI clamp 20X3 mm nuts, bolts and washers incl provision of 01 No miniature circuit breaker (MCBs) single pole, 240 volts 10 KA 16 Amps and incl suitable capacity aluminium bus bar, complete all as specified and as directed. 52 S & F LT cable path indicators of oval shaped size 200mmX150mmX6mm thick made of or moulded cast iron and embossing LT UG cable and fixed on MS angle iron 25x25x5mm thick 40 cm in length with two nos nut, bolts and washers, including two coats of synthetic enamelled paint over a coat of zinc coat primer on exposed surface, angle iron to be fixed in to the ground including suitable PCC work and earth work complete all as specified and as directed. 53 S & F HT cable path indicators of oval shaped size 200mmX150mmX6mm thick made of or moulded cast iron and embossing HT UG cable and fixed on MS angle iron 25x25x5mm thick 40 cm in length with two nos nut, bolts and washers, including two coats of synthetic enamelled paint over a coat of zinc coat primer on exposed surface, angle iron to be fixed in to the ground including suitable PCC work and earth work complete all as specified and as directed. 54 Supply and fix 11 KV 5 KN Polymeric Pin insulator 24 mm dia FRP rod complete all as specified and as directed. 55 Supply and fix 11 KV 45 KN Polymeric insulator No 06 complete all as specified and as directed. 56 Cutting the tar macadam roads/hard standing for laying cable and excavating not exceeding 1.5 m width and 1.5 m in depth and getting out all as directed including filling back and finishing it with PCC complete matching with the surroundingcomplete all as specified and as directed by Engr-in-Charge. 57 Supply, install testing and commisioning of 11 KV HT metering cubicle of different CT Ratio 15/1A, both side cable entry type with 3 CTs & 3 PTs 11 KV/110V with transparent cover TTB, with 30x8 mm Cu Bus bars, Modem and 2 Nos of meters for 3 Ph, 4 wire Meteringincluding suitable PCC foundation all as specified and as directed by Engr-in- Charge. 58 Supply and fix Compact RMU additional 1 VL, 350 MVA, 630A compatible to existing ABB make RMU of 2OD+4VL incl suitable foundation as per manufacturer recommendation. (Note :- Foundation including earth work shall be measured and paid seperately) 59 Supply and fix Outdoor Load Break Switch 11 KV 630 A 21 KA / 3 Secs compact safelink type manually operated extensible DC RMU including suitable foundation as per manufacturer recommendation complete all as specified and as directed. 60 Material and labour for Chain link fencing 45 RM with 01 No Gate of width 3 mtr, height 1.2 mtr (double openable) for Protection of metering cubicle complete all as directed. 61 AVIATION LIGHTSupply and fix LED Aviation lightluminariescomprising of aluminium with polycarbonate enclosure 302 Nos LEDcomplete all as specified and as directed. 62 AIR CONDITIONING:-Supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input voltage variation between 170 V and 250 Volts with out put voltage of 230 V with accuracy of + 2.5% of capacity 5 KVA complete all as directed. 63 Supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input voltage variation between 170 V and 250 Volts with out put voltage of 230 V with accuracy of + 2.5% of capacity 4 KVA complete all as directed. 64 REFRIGERATION / DEEPFREEZER / WATER COOLERSupply and fix Refrigerator, electric driven (single phase) of capacity minimum 310 Litres, double door with latest multi air flow technology having eco friendly refrigerent and BEE 5 star rated yard complete all as specified and directed by the Enginer-in-Charge 65 Supply andfix1 KVA Automatic voltage stablizer for AC of range 190V to 270V Output voltage stablizer at 230 voltage (+-)2.5% complete all as directed 66 Supply andfix 0.5 KVA Automatic voltage stablizer for AC of range 190V to 270V Output voltage stablizer at 230 voltage (+-)2.5% complete all as directed 67 HOT WATER SUPPLYSupply , install, testing and commissioning of LT feeder pillar box, CPRI Approved AC 415 V, 50 HZ 3 Phase 4 wire of suitable size for accomodating the following accessoriestotally enclosed self supporting structure / cubicle, fully compartmentalized type , suitable for outdoor use, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick CRCA steel sheet with angle iron frame work and legs of ISA 40X40X3 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover switch and MCCBs, hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 8 - tank metal treatment process and duly powder coated, complete all as specified 68 BUSBAR :-(i)Aluminium bus bar 200 Amps, 415 Volt , supported on non hygroscopic fibres, studs and brass screws for mounting -04 NosINCOMER(a) Supply and fixing MCCB of 4 poleof capacity 63 amps with breaking capacity of 10 KA adjustable thermal andmagnetic setting - 01 NosINDICATING DEVICES(a) Supply and fixing LED Indicating lamps for Main Supplyindicating R, Y, B set of 3 - 01 Nos(b) Supply and Fixing Digital Metering Unit with ammeter, Voltmeter and Phase Indicator - 01 NosOUTGOING FEEDERS(a) MCB SPN 6- 32 A- 08 Nos
|