Tender For Repair And Maintenance Of Summer Appliances And Connected Equipment Mil Stn Dappar; 1 Servicing of solar water heating plant capacity upto 1500 Ltr capacity at site complete, opening of all tubes descaling and replacing broken/ u/s panel , fixing float valve of suitable size ,making good surface and fixing in original position, opening of water heating tank cleaning, replacing heating element of 3 x 3KWas per existing model/size and making leak proof and testing to the entire satisfaction of Engr-in-Charge all as specified and directed by Engr-in-Charge. 2 Supply and fix in replacement heating element with capacity 3/4 KW suitable or as per site requirementfor upto 1500 Ltr capacity solar water heating plant all as specified and directed by Engineer-in-charge. 3 M&L for MS pipe 40mm dia connecting, welding , smoothing and making leak proof and including insulation with puff slab 30mm thick with wire mesh to bound the puff and including applying CRPX compound and cladding with 24 gauge aluminium super quality sheet including clamping/ binding material as per site requirement/directed and testing entire work to be carried out providing material strictly of existing specifications and to the entire satisfaction of Engineer-in Charge, including dismantling of old MS pipe complete all as specified and directed by Engr-in-Charge. 4 Taking down existing old unserviceable puf insulation from MS pipe and Material and labour for insulation over a existing MS pipe of size upto 80mm dia with puff slab 30mm thick with wire mesh to bound the puff and including applying CRPX compound and cladding with 24 guage alluminium super quility sheet including clamping/ binding material, testing as per site requirment and directed by Engr-in-charge. 5 Taking down and servicing of ceiling fan1200/1400 mm sweep at siteand removing of old grease from bearing of ceiling fan and re-filling new grease including replacement of worn out nut bolt/ washer, rubber real bush, canopy alongwith all suitable items as per site requirment and reassembling the fan complete and hanging on its original/ new position as directed by Engr-in-charge.Note: MS nut bolts with split pin, Ball bearing and Gun metal bush will be paid and measured seperately. 6 Taking down and servicing of BLDC ceiling fan1200/1400 mm sweep at siteand removing of damaged / old parts i.e electronic parts, rotor, stator ,shaft including all damaged parts of BLDC Fan and re-filling new grease including replacement of parts i.e electronic parts, rotar, stator , copperwinding shaft including all damaged parts of BLDC Fan as per site requirment and reassembling the fan complete and hanging on its original/ new position as directed by Engr-in-charge. 7 Taking down and servicing / cleaning of exhaust fan 230 to 450 mm sweep at site and removing of old grease from bearing of exhaust fan and re-filling new grease including replacement of worn out nut bolt, rubber real bush, gun metal ball bearing, capacitor, split pin alongwith all suitable items as per site requirment etc andreassembling the fan complete and hanging on its original/ new position as directed by Engr-in-charge. 8 Supply only MS Nut bolts with split pin as per sample for hanging of any capacity of Ceiling Fans and as directed by Engineer-in-Charge. 9 Supply only Ball bearing , Rubber shackel suitable size of ceiling fan / pedastal and exhaust-fan of any type and size. 10 Supply only gun metal clamp with bush suitable for ceiling fan of any type and size including removing old one. 11 Taking down and opening the body cover of ceiling fan any type and make and cutting the existingworn out winding with out damaging the stator removing the coil insulation and putting new insulation of polyster paper, winding with super enameled copper wire of suitable gauge with correct number of turns of auxillary and main winding and varnishing and baking complete includingsoldering new lead of copper wire testing complete including transportation to work shop and back all as directed as engr-in-charge. 12 (a) Ceiling fans 1200/1400 mm sweep 13 (b) Exhaust fan Upto 230 to 300mm sweep 14 (c) Wall mounted fan 400mm sweep 15 M& L in replacement of Exhaust fan louvers metal body of suitable for 250 to 350 mm sweep exhaust fanfix at a itsexisting position.Completeall as specified and as directed by Engineer-in-charge. 16 M& L in replacement of Exhaust fan louvers metal body of suitable for 450 mm sweep exhaust fanfix at a its existingpositiomn Completeall as specified and as directed by Engineer-in-charge. 17 Supply and fix in replacement of unserviceable capacitor4/ 5 MFD or as per the site requirement Completeall as specified and as directed by Engineer-in-charge. 18 Supply and fix in replacement of unserviceable capacitor2.5/ 3.15MFD or as per the site requirement Completeall as specified and as directed by Engineer-in-charge. 19 M&L for painting one coat after cleaning all dust painting with MES NO /SM NO on fans etc to ceiling fan complete,with synthetic enamel paint by spray painting including filling cavities with filler, and hanging at original locations complete all as specified and directed by Engineer-in-charge. 20 Supply and fix in replacement of fan blades (set of three blades) suitable for 1200/1400/1500mm sweep fanCompleteall as specified and as directed by Engineer-in-charge. 21 Supply and fix in replacement M.S rodof length of 1.5and suitable diaincluding clamp , nut & split pinsuitable for 1200/1400/1500mm sweep fan Completeall as specified and directed byEngineer-in-charge. 22 Supply and fix in replacement fan blade set suitable for Exhaust fan 300 to 450 mmsweep completeall as specified and directed by Engineer-in-charge. 23 Taking down desert cooler of any make & size at different site / location and carrying out necessary repairs as to stop leakage and replacement of rusted nuts bolts ,washers etc and scrapping of old paint and removing scales from internal & external surfaces top and bottom complete and providing two coats of synthetic enamel (hammer tone) paint by spray machine over one coat of red oxide primer including writing of MES/SM NO in 3 cm height and re fixing in existing position after greasing ,oiling and servicing of fan motors pumps and making good and serviceable condition all as specified and directed byEngineer-in -Charge. 24 M&L for rewinding toDesert cooler motor of450/500 mm sweep winded with winding machinewith super enamelled copper winding wire of existing size gauge & design includinginsulated sleeves , paper , varnishing with ‘B’ class insulation varnish, thimbles, connection with flexible cableof copper conductor of size 23/.0076up to connector block completeall as specified and directed by Engineer-in-charge. the above shall be done at the MES store yard. 25 Supply and fix in replacement Desert cooler fan motor of copper winding of capacity 200W, 1300 RPM 50HZ 240 Volts, winding material- Copper, single phase, 500 mm sweepas per existing suitable size , and approved make. 26 Supply and fix in replacement pump 18 watt or as per suitable site condition , 220 volts AC electric driven suitable for 4 meter head all as specified and directed byEngineer-in -Charge. 27 Supply and fix in replacement dusty/worn out wool/grass pad (set of 3 nos) all as specified and directed byEngineer-in -Charge. 28 Supply and fix in replacement Honey bee pad (set of 3 nos) synthetic all as specified and directed byEngineer-in -Charge. 29 Supply and fix in replacement polyethylene pipe of 15mm bore high density of existing specifications all as specified and directed byEngineer-in -Charge. 30 Supply and fix in replacement selector switch (3 speed) of existing specifications with conncetd items all specified and directed by Engineer-in-Charge. 31 Supply and fix in replacement PVC ELBOW (Set of three) and Tee (One) Right angle of existing specifications all as specified and directed byEngineer-in -Charge. 32 Supply and fix in replacement PVC top plug 3 pin 5Amp 230 Volts all as specified and directed byEngineer-in -Charge. 33 Supply and fix in replacement flexible copper conductor size 23/0.0076 3 core pvc insulated sheet all as specified and directed by Engineer-in-charge. 34 Supply and fix in replacement of Capacitor 4 mfd 230 Volts (+-) 5 %or suitable size as per the site requirement dry type complete suitable for desert cooler all as specified and directed. 35 Taking out to unserviceable MSpart body of any capacity including existing fan, motor, blades, water lifting pump and electric wiring, fitting switches etc complete all as specified and directed by Engineer-in –Charge 36 M& L GI steel body of desert cooler of capacity 3000cum duly painted with two coats synthetic enamelled paint on external surface and black painting with MES NO /SM NO on internal surface over one coat of red oxide primer with spray gun machine.The body of desert cooler will be fabricated as under mentioned complete all as specified and directed by Engineer-in –Charge (a) Top and bottom made out of 1.25 mm thick GI sheet. (b) side panels(set of 3) made out 1.00 mm thick GI sheet with wood wool pads and wire mesh of GI wire 1.4 mm dia 2.5 mm mesh for holding pads. (c) Front grill of suitable size and approved quality GI sheet. (d) Re fixing serviceable existing fan water lifting pump, fan, motor, blades, wiring, fittings etc. NOTE: Unserviceable parts shall be replaced with new serviceable parts and shall be paid as supply only under respective items of this schedule. 37 Supply and fix in replacement desert cooler side panels(set of 3) as per existing sizes orapprox. size 60x70 cm made out of 22 SW9 GI sheet with handle all as specified and directed by Engr - in Charge. 38 M&L in replacement existing sizes of front show grill or approx. size 55x60 cm for any make type of desert coolers having provision for rotary selector switch and toggle switch complete all as specified and directed by Engineer-in -Charge. 39 S & Ffan blade ofsuitable size and make for desert cooler complete all as specified and directed by Engineer-in-charge 40 S & F metallic frame with set of 4 legs as per model suitable for fixing/mounting fan motor of desert cooler with nuts, bolts, rubber etc., complete all as specified and directed. 41 Servicing of Air conditioners of window/ split type of any capacity i.e 1.5/ 2 Ton by removing dirt and debries on all parts of air conditioner, washing and lubricating all moving parts complete by the manufacturer technician as directed by the Engr-In-Charge as per standard norms of the Manufacturer. Note :1.Lowering, dismantling, re-installing of air conditioners after reassembling the equipment in same/different position shall be included in the unit quoted rate. 2. Day to day complaints of different items should be attended within 12 hours and the equipment should be operational within 24 hours in case of Minor Complaints and within 72 hours for Major complaints.3. Failure to attend the complaint within the prescribed time shall attract a penalty of Rs 100 per day per complaint. and Rs. 50 for subsequent days.4. Decision of Accepting Officer will be final in case of fine payment 42 Disconnecting to unserviceable sealed compressor of 1.5/2 Ton capacity window type AC and M& L replaced with new company sealed compressor of existing capacity& model including soldering of liquid /gas pipe ,cleaning the system & testing the leakingwith gas charging all as per site requirment etccomplete all as specified and directed by Engineer-in-charge. 43 Disconnecting to unserviceable sealed compressor of 1.5/2 Ton capacity split type AC andM& L replaced with new company sealed compressor of existing capacity& model including soldering of liquid /gas pipe ,cleaning the system & testing the leakingwith gas charging all as per site requirment etccomplete all as specified and directed by Engineer-in-charge. 44 M& L Recharging of gas R-22 or as per site requirmentsin air conditioner unit window type and split type1.5/2 ton complete including testing of leakage and testing for satisfactory performance Complete all as specified and directed by Engineer-in-Charge. 45 Supply and fix inreplacement thermostat switch suitable for existing capacity of window and split type AC (1.5/2 Ton capacity ) complete all as specified and as directed by Engineer-in-Charge. 46 Supply and fix in replacement starting capacitor upto 100 mfd suitable or as per site requirments for window/split type AC of anycapacity complete all as specified and as directed by Engineer-in-Charge. 47 Supply and fix replacement runningcapacitor 36 MFDsuitable or as per site requirment forwindow/ split type ACof anycapacity complete all as specified and directed by Engineer-in-Charge. 48 Supply and fix in replacement over load protector suitable as per site requirment for split/windowtype AC 1.5/2Ton capacity complete all as specified and directed by Engineer-in-Charge. 49 Supply only Front grill of window / split type AC with shutters as per existing model/capacitycomplete all specified and directed by EIC 50 Supply only 1/2 and 1/4 reverse valve for window / split AC valve as per existing model/capacity complete all as specified and directed by EIC .( Set of 2 ) 51 Supply only suction valve size 3/8 for 1.5/2 TR window/split AC or as per existing model / capacity complete all as specified and directed by EIC. 52 Supply only delivery valve size 1/2 for 1.5/2 TR window / split AC or as per existing model / capacity complete all as specified and directed by EIC. Make: BAP/ TAK Cassel 53 Supply only swing motor for 1.5/2 TR window / split AC indoor unit for any existing make complete all as specified and directed by EIC. 54 Supply and fix in replacement of Fan motor for split typeAir Conditioner of capacity 1.5/2.0 Ton as per existing model of approved all as per irected by Engr-in-Charge. 55 Supply and fix in replacement of Rolling type PVC Blower for indoor unit of split AC 1.5 / 2.0 Ton Capacity Make as per existing make / modelas directed by EIC 56 Supply and fix Fan Blade for out door unit of split AC 1.5 /2.0 Ton Capacity make as per Existing size / Model as directed by EIC. 57 Supply and fix in replacement of PCB assemblyof existing make for window / split type ACs 1.5 to 2.0 ton all as directed by EIC. 58 Supply and replacement of fan blade of existing size / model of window ACs complete as directed by EIC. 59 Supply and fix in replacement new fan motor of existing size / model of Window AC as specified and directed by EIC 60 Supply only remote control hand set for existing capacity / model of Window type/ split type air conditioner with requred pencil cells as per sample complete all as specified and directed. 61 Supply and fix in renewal outdoor condensing unit of spilt type AC of capacity 1.5 ./ 2 TR capacity complete with condensing coil, coil frame, wiring kit, starting and running capacitors, relay condensing/ outdoor motor with blade complete all as specified and as directed. 62 Supply and fix in renewal ofindoor unit of 1.5 / 2 TR capacity split type ACwith blower motor, front grill and connecting the copper tubing by brazing, detecting leakage, rectifying the same complete all as specified and as directed.Note : Supply and charging of refrigerant gas as required shall be measured and paid for separately. 63 Supply and replacement ofcopper pipe heavy duty of size 5/8 all as specified and directed by EIC 64 Supply and replacement ofcopper pipe heavy duty of size 3/8 all as specified and directed by EIC 65 Supply and fixing pipe insulation for copper pipe of size 5/8 and 3/8 all as specified and directed by EIC 66 Disconnecting and taking out worn out/unserviceable sealed compressor of water cooler of capacity 40/80/120 ltrs and M& L replacing with new sealed compressor of existing capacity and size including soldering of suction and discharge line gas pipe and flushing the complete system and making leak proof all as specified and directed by Engineer-in-charge. 67 Cleaning the system with CRC and charging the refrigerant gas as per site requirment (R-22/M22)including replacement of strainer filter suitable for water cooler of 40/80/120litrescapacitycomplete all as specified and directed by Engineer-in-charge. 68 Supply and fix in replacement Startingrelay assemblysuitable forwater cooler of 40/80/120 ltr capacityComplete all as specified and directed by Engineer-in-Charge 69 Material & Labour internal wiring forwater coolers 40/80/120 ltr capacity with PVC insulatedunsheathed flexible copper conductor cablesingle core size 40/0.0076fixed with terminal clips etc including replacement of screws, washers etc required for fastening with body etc complete all as specified and directed by Engineer-in-charge. 70 Supply and fix in replacementStarting capacitor suitable as per site requirment (40-60 mfd)assembly for water cooler all as specified and directed by Engineer-in-Charge 71 Supply and fix in replacement Running capacitor 10 mfd assembly or as per site requirment for water cooler all as specified and directed by Engineer-in-Charge. 72 Supply and fix in replacement over load protectorfor water cooler suitable complete all as specified and directed by Engineer-in-Charge 73 Supply and fix in replacement drain hose pipe 40mm diasuitable forwater cooler of 40/80/120 liter capacitycomplete all as specified and directed by Engineer-in-Charge. 74 Supply and fix in replacement clamp for fan motor of 1/16 to 1/32 hp hose pipeof water cooler complete all as specified anddirected by Engineer-in-Charge 75 Supply and fix in replacement fan blade plastic for fan motor 1/32 hp for water coolercomplete all as specified and directed by Engineer-in-Charge. 76 Supply and fix inreplacement clamp for hose pipe complete all as specified and directed by Engineer-in-Charge. 77 Supply and fix in replacement fan motor with new one suitable for water cooler of capacity 40/80/120ltrs complete all as specified and directed by Engineer-in-Charge. 78 Supply and fix in replacement self closing tap push type 15 mm bore of cast copper alloy chromium plated fixed to water cooler as in repair complete all as specified and directed by Engineer-in-Charge. 79 Dismantling of unsv float valve assy and supply and fixing PVC float valves complete assy 15 mm sizeor as per the site requiremenrtcomplete all as specified and directed by Engr-in-Charge. 80 Supply and fix in replacement thermo-stat switch with new one complete for water cooler all as specified and directed by Engineer-in-Charge. 81 Cutting the rusted unserviceable base of 120/80/40 litre capacity, water cooler body, material and labour for fabrication of new base made of MS sheetand angle iron as per existing size and thickness incl welding of small patches as directed by engr in charge 82 Supply and fix in renewal, condensing coil for water cooler capacity 40/80/120 Litres of existing make of 22 Gauge MS sheet duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by EIC. 83 Supply and fixing in replacement of complete top door made out of stainless steel 20 gauge sheet with handle and locking arrangement with double keys including door gasket, insulating material, PVC inner sheet of suitable thickness for any capacity water cooler as per existing size and shape, welding work, nuts, bolts and washers all as directed and specified by engr-in-charge. 84 Material and Labour for detecting any leakage from cooling and condensing coil fin of water cooler any capacityof any make with the help of high pressure nitrogen gas and repairing the leakage by welding/brazing of cooling and condensing coils by disconnecting inclusing renewal of new filter, new capillary tube and testing the unit complete all as specified and directed by EIC . 85 Material and Labour fornew water tank of any capacity of water coolercooling capacity including all outer side puffing for insulation complete all as specified and directed by EIC. 86 Disconnecting to unserviceable sealed compressor for upto 310 ltr capacity ofrefrigerator and M & L replaced with new company sealed compressor of existing capacity& model including soldering of liquid /gas pipe ,cleaning the system arresting the leaking etccomplete all as specified and directed by Engineer-in-charge 87 Disconnecting to Unserviceable Freezer door of capacity upto 310 ltr refrigerator andM & L Replace the Freezer door plastic with tension spring of existing modelsuitable upto 310liter cap refrigerator. 88 Disconnecting to unserviceable freezer chamber of refregerator of capacity upto 310 ltr and M& L replaced with New freezer chamber of refrigerator of capacity upto 310ltr of existing capacity& model including soldering of liquid /gas pipeline,cleaning the system arresting the leaking etccomplete all as specified and directed by Engineer-in-charge. 89 M & L Cleaning the system with CRC and charging the refrigerant gas R-134 or as per site requirment ,including replacing strainer and rectification of leakage in the system from refrigerator upto 310 litrescapacitycomplete all as specified anddirected by Engineer-in-charge. 90 Supply and fix in replacementstartingrelay assemblysuitable forrefrigerator upto 310 litrescapacitycomplete all as specified and directed by Engineer-in-Charge. 91 Supply and fix in replacement Starting capacitor of suitable size or 40-60 mfd assembly suitable forrefrigerator upto 310 litres capacityComplete all as specified and directed by Engineer-in-Charge 92 Supply and fix inreplacement over load protector suitable forrefrigerator upto 310 litrescapacityComplete all as specified and directed by Engineer-in-Charge 93 Supply and fix in replacement thermo-stat switch suitable for refrigerator anycapacityComplete all as specified and as directed by Engineer-in-Charge. 94 Supply and fixing Timer for Refrigerator of Capacity upto 310 Ltrs or existing size as per direction of EIC. 95 Supply and replacement of fan motor of freezer of refrigerator upto 310 ltr existing size as per direction of EIC. 96 Supply and fix in replacement heating element with capacity 2KW suitable for existing make / model ofgeyser 50ltrs capacityall as specified and directed by Engineer-in-charge. 97 Supply and fix in replacement heating element with capacity 1KW suitable for existing make / model of geyser 25ltrs all as directed by Engineer-in-charge. 98 Supply and fix in replacement Thermostat suitable for existing make / model ofgeysers 25 to 50 Ltrs complete all as specified and directed by Engineer-in-charge. 99 Supply and fix in replacement Pressure release valve of existing specification & make for geysers of cap 25 to 50 Ltrs complete all as specified and directed by Engineer-in-Charge. 100 Preparation surface for painting and painting of geysers cap 25/50Ltrs with 2 coats of synthetic enamel painting with MES NO /SM NO in situ complete all as specified and directed by Engineer-in-Charge 101 Supply and fix in replacement copper tank of existing specifications & make suitable for cap of 25 ltrs geyser complete all as specified and directed by Engineer-in-Charge. 102 Supply and fix in replacement copper tank of existing specifications & make suitable for cap of 50 ltrs geyser complete all as specified and directed by Engineer-in-Charge. 103 Supply and fix in replacement Gun Metal non return valve size of 15 mm of existing make for geysers of cap 25 / 50 Ltrcomplete all as specified and directed by Engineer-in-Charge. 104 Supply and fix in PVC connectionpipe with male female sockets length as per site requirment long for geyser 25/50 ltrs capacity complete all as specified and directed by Engineer-in-charge. 105 Supply and fix in replacement Sheet metal enclosure with socket plug top and MCB SPN cap 32 Amps with a 2 pin,earth plug and socket complete all as specified and directed by Engineer-in-Charge. 106 Dismaintling of voltage stablizer and M & L various components of automatic voltage corrector of any rating but cap not exceeding 5 KVA, single phase , 50 Hz including locating the faults complete all as specified and directed by Engineer-in-Charge. 107 Dismaintling of burnt U/S main transformer copper wound and stamping and material and labour for re-assembling the stemping and re-winding of main transformer, single phase, 50 Hz with super enamelledcopper winding wire of existing size, design & weightSWG turns / tapping and varnishing complete of voltage stablizer cap up to 5 KVA, complete all as specified and directed by Engineer-in-Charge. 108 S&F (in replacement) voltage regulator PCB for voltage stabliser for power rating upto 5KVA complete all as specified and directed by Engr -in-Charge. 109 Disconnecting to unserviceable sealed compressor ofdeep freezer of capacity 300 - 350 Ltrsand M& L replaced with New sealed compressor of existing capacity& model including soldering of liquid /gas pipeline,cleaning the system arresting the leaking etccomplete all as specified and directed by Engineer-in-charge 110 M& L Cleaning the system with CRC and charging the refrigerant gas R-134 or as per site requirmentincluding replacing strainer and rectification of leakage in the system from deep freezer of 300-350litrescapacitycomplete all as specified and as directed by Engineer-in-charge. 111 M& L for Cleaning tointernal surfaces of deep freezer of 300-350 litres capacity suitable repairs tobody to stop leakage etc, replacing unserviceable nuts bolts & washers etc including preparation of external surfaces ofbodyandpainted withanticorrosive synthetic enamel paint withhelp of spray gunmachine over a coat of red oxide and writing SM / MES No in 3cm height Complete all as specified and as directed by Engineer-in-Charge. 112 S&F in replacement startingrelay assembly suitable for deep freezer of 300-350 litrescapacitycomplete all as specified and as directed by Engineer-in-Charge 113 Material & Labour internal wiring for deep freezer of 300-350 litres capacity with PVC insulatedunsheathed flexible copper conductor cablesingle core size 40/0.0076fixed with terminal clips etc including replacement of screws, washers etc required for fastening with body etc complete all as specified and as directed by Engineer-in-charge. 114 Supply and fix in replacementStarting capacitor 40-100 mfd assembly or as per the site requirmentsuitable fordeep freezer of 300-350 litrescapacityComplete all as specified and as directed by Engineer-in-Charge 115 Supply and fix in replacement Running capacitor 10-20 mfd or as per the site requirementsuitable fordeep freezer of 300-350 litrescapacityComplete all as specified and as directed by Engineer-in-charge 116 Supply and fix in replacement over load protector suitable fordeep freezer of 300 -350 litrescapacityComplete all as specified and as directed by Engineer-in-Charge 117 Supply and fix in replacement Drain hose pipe suitable size / dia with suitable clampfordeep freezer of 300 -350 litrescapacityComplete all as specified and as directed by Engineer-in-Charge 118 Supply and fix in replacementfan blade plastic for fan moter 1/32 hp suitable forfan blade plastic for fan moter 1/32 hpdeep freezer of 300 - 350 litres capacityComplete all as specified and as directed by Engineer-in-Charge. 119 Supply and fix in replacement fan motor suitable fordeep freezer of 300 - 350 litres capacitywith suitable clamp complete all as specified and as directed by Engineer-in-Charge. 120 Supply and fix in replacement condensor coilsuitable fordeep freezer of 300 - 350litres capacitycomplete all as specified and as directed by Engineer-in-charge. 121 Supply and fix in replacement thermostat switch with new thermostat switch suitable for deep freezer anycapacitycomplete all as specified and as directed by Engineer-in-charge. 122 Supply and fixing in replacementMCBSP 6 -32 Amps,10 KA, C series 240 V ISI marked complete all as specified and directed by Engineer-in-charge. 123 Supply and fixing in replacement MCB SPN 06-32Amps,10 KA C series 240 V ISI marked.complete all as specified and directed by Engineer-in-charge. 124 Supply and fixing in replacement MCB TPN 63Amps,10 KA C series 240 V ISI marked.complete all as specified and directed by Engineer-in-charge.
|