Tender For Electrical Works For Gds Unit At Nrep; 1 GENERAL NOTES(1) This document shall be read in conjunction with doc. ANNEXURE-II TO SCC - SCOPE OF SUPPLY - ELECTRICAL.Technical Specification for the equipment / material to be supplied by CONTRACTOR is included therein.(2) For Limit of Variation in the rates / quantities / total value of work, please refer SPECIAL CONDITIONS OF CONTRACT.(3) Refer the document LIST OF APPROVED VENDORS / MAKES -ELECTRICAL for the makes of equipment / material to be supplied by CONTRACTOR(4) For all the equipment (suitable for Explosive Atmospheres) to be supplied by CONTRACTOR, relevant certification from applicable recognised approving authority shall be provided. (5) For CONTRACTOR supplied items mentioned below, procurement / supply clearance for the items shall be given to CONTRACTOR, in lots as per Project requirement. Subsequent to the receipt of procurement / supply clearance, CONTRACTOR may initiate the required action in this regard.(6) CONTRACTOR should read entire specification to understandin totality the scope of supply and Installation. Every line item for Supplies and Installation should be read along with the respective Installation standard / hook up drawings related to that specific line item to understand the scope of supply and Installation in totality. Any miss outs in supply scope in this regard by the CONTRACTOR shall not be entertained. 2 EQUIPMENT 3 LV PANELS (WALL / CONCRETE / STEEL STRUCTURE MOUNTED)Supply of LV panels (wall / concrete / steel structure mounted) as per doc. no.TK-1ZZZA-EL-SPE-0017 (Technical specification for Industrial Equipment) and TK-1ZZZA-EL-SPE-0018 (Technical Specification for Flameproof Equipment) 4 Industrial Indoor type 5 For Explosive Atmospheres 6 LDBLighting Distribution Board) 7 18 Way 8 ELDB(Emergency Lighting Distribution Board) 9 15 Way 10 PDB(Auxiliary Power Distribution Boards) 11 15 Way 12 PDB for Hydro Jet area(Auxiliary Power Distribution Boards)feeder pillar with 1No. 400A I/C and outgoings with 2Nos.250A and 1 no.125A and 1 no. of 63A (Installation type : P10) 13 LOCAL CONTROL STATIONS (LCS)Supply of Local Control Stations as per doc. no. TK-1ZZZA-EL-SPE-0021 (Technical Specification for Local Control Stations) 14 LCS for Explosive Atmospheres 15 Type A3 : Flameproof (Gas Group : IIC) : Start PB (Green); Stop PB (Red) with stay put feature, shrouded type, with pad locking facility & each PB shall have 2NO+2NC contacts 16 Type B3 :Flameproof (Gas Group : IIC) : Start PB (Green, shrouded type); Stop PB (Red) Mushroom type,with stay put feature, with pad locking facility & each PB shall have 2NO+2NC contacts & Ammeter(1A, MI type) 17 Type D3 : Flameproof (Gas Group : IIC) : Start PB (Green, shrouded type); Stop PB (Red) Mushroom type, with stay put feature, with pad locking facility & each PB shall have 2NO+2NC contacts. With Local/ Remote Selector switch lockable in both the positions, Key shall be removable only in OFF position &Ammeter(1A, MI type) 18 Type F4 :Flameproof (Gas Group : IIC) : Start PB (Green, shrouded type); Stop PB (Red), shrouded type; Key lockable emergency stop PB (Red), Mushroom type, with stay put feature, with pad locking facility; each PB shall have 2NO+2NC contacts; Ammeter (4-20mA); Analog RPM meter (4-20mA); key lockable A-M selector switch; Speed Lower-Speed Raise Push buttons 19 Type J3 :Flameproof (Gas Group : IIC) : Stop PB (Red), Mushroom type, with stay put feature, with pad locking facility & with 2NO+2NC contacts 20 Type L4 :Flameproof (Gas Group : IIC) :Trip-Neutral-Close (T-N-C) switch shall be spring return to neutral type from CLOSE position with two contacts each for time stamping & tripping signal. Switch shall be lockable in TRIP position. With Local/ Remote Selector switch lockable in both the positions, Key shall be removable only in OFF position & Ammeter(1A, MI type) (Configuration:T-N-C SWITCH + AMMETER + RUN INDICATION + TRIP INDICATION) 21 Type P3 :Flameproof (Gas Group : IIC) :Trip-Neutral-Close (T-N-C) switch shall be spring return to neutral type from CLOSE position with two contacts each for time stamping & tripping signal. Switch shall be lockable in TRIP position & Ammeter(1A, MI type) 22 CABLES AND WIRES, GLANDING, TERMINATIONS AND CABLE ROUTING SYSTEMS 23 CABLE GLANDING AND TERMINATION (HV) 24 HV Cable glands Industrial type- Supply of cable glands HV cable glands industrial type and all the associated accessories as per ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL.- CONTRACTOR shall be responsible selection and supply of exactly suitable cable glands for the actual cables (technical particulars as per project technical specification) installed at site and equipment cable entry tread.OD mentioned below indicate approximate overall cable diameters. 25 HV Cable gland suitable for 6.6 / 6.6 kV (UE) voltage grade, Al conductor, XLPE insulated, screened, armoured power cable 26 3C x 240 sq.mm A2XCEFY (UE) (OD : 69 mm) 27 HV Cable glands for Explosive Atmospheres- Supply of cable glands HV cable glands industrial type and all the associated accessories as per ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL.- CONTRACTOR shall be responsible selection and supply of exactly suitable cable glands for the actual cables (technical particulars as per project technical specification) installed at site and equipment cable entry tread.OD mentioned below indicate approximate overall cable diameters. 28 HV Cable gland suitable for 6.6 / 6.6 kV (UE) voltage grade, Al conductor, XLPE insulated, screened, armoured power cable 29 3C x 240 sq.mm A2XCEFY (UE) (OD : 69 mm) 30 HV Cable termination kit - Supply of HV cable termination kit along with all the associated accessories and suitable tinned copper lug for cable termination at designated location- CONTRACTOR shall be responsible for selection and supply of exactly suitable cable termination kit for the cables (technical particulars as per project technical specification) as per the required site conditions and available termination arrangement, and as per the cable technical specification. 31 HV Cable termination kit Heat shrinkable type (suitable for indoor installation) for 6.6 / 6.6 kV (UE) voltage grade, Al conductor, XLPE insulated, screened, armoured power cable 32 3C x 240 sq.mm A2XCEFY (UE) (OD : 69 mm) 33 CABLE GLANDING AND TERMINATION (LV) 34 LV Cable glands Industrial type- Supply of cable glands LV cable glands industrial type and all the associated accessories as per ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL.- CONTRACTOR shall be responsible selection and supply of exactly suitable cable glands for the actual cables (technical particulars as per project technical specification) installed at site and equipment cable entry tread.OD mentioned below indicate approximate overall cable diameters. 35 Cable glands suitable for 650 / 1100 V (Uo / U) voltage grade, Al / Cu conductor (stranded / solid), XLPE insulated, screened, armoured power / control / lighting cables 36 4 x Pair x 2.5 (OD : 26.6 mm) 37 8 x Triad x 1.5 (OD : 33.2 mm) 38 3 x Triad x 2.5 (OD : -----mm) 39 2C x2.5 Sq. mm (2XWY) (OD : 14 mm) 40 2C x 6 Sq. mm (2XWY) (OD : 16.6 mm) 41 3C x2.5 Sq. mm (2XWY) (OD : 14 mm) 42 3C x 4 Sq. mm (2XWY) (OD : 15 mm) 43 3C x 6 Sq. mm (2XWY) (OD : 16.5 mm) 44 3C x 10 Sq. mm (2XWY) (OD : 18.5 mm) 45 3C x 16 Sq. mm (2XWY/2XFY) (OD : 19.7 mm/17.8 mm) 46 4C x 10 Sq. mm (2XWY/2XFY) (OD : 21.8 mm) 47 5C x 2.5 Sq. mm (2XWY) (OD : 16 mm) 48 6C x 2.5 Sq. mm (2XWY) (OD : 17.2 mm) 49 7C x 2.5 Sq. mm (2XWY) (OD : 17 mm) 50 8C x 2.5 Sq. mm (2XWY) (OD : 18.0 mm) 51 10C x 2.5 Sq. mm (2XFY) (OD : 19.5 mm) 52 12C x 2.5 Sq. mm (2XFY) (OD : 22.2 mm) 53 16C x 2.5 Sq. mm (2XFY) (OD : 22.0 mm) 54 24C x 2.5 Sq. mm (2XFY) (OD : 26.7 mm) 55 2C x 50 Sq. mm (A2XFY) (OD : 22.7 mm) 56 2C x 70 Sq. mm (A2XFY) (OD : 25.5 mm) 57 3C x 35 Sq. mm (A2XFY) (OD : 23 mm) 58 3C x 50 Sq. mm (A2XFY) (OD : 26 mm) 59 3C x 70 Sq. mm (A2XFY) (OD : 29 mm) 60 3C x 95 Sq. mm (A2XFY) (OD : 33 mm) 61 3C x 120 Sq. mm (A2XFY) (OD : 36 mm) 62 3C x 150 Sq. mm (A2XFY) (OD : 39.2 mm) 63 3C x 185 Sq. mm (A2XFY) (OD : 45 mm) 64 3C x 240 Sq. mm (A2XFY) (OD : 51 mm) 65 3C x 300 Sq. mm (A2XFY) (OD : 53 mm) 66 4C x 25 Sq. mm (A2XFY) (OD : 22.2 mm) 67 4C x 35 Sq. mm (A2XFY) (OD : 27 mm) 68 4C x 50 Sq. mm (A2XFY) (OD : 30 mm) 69 4C x 70 Sq. mm (A2XFY) (OD : 34 mm) 70 4C x 95 Sq. mm (A2XFY) (OD : 37 mm) 71 4C x 120 Sq. mm (A2XFY) (OD : 41 mm) 72 4C x 150 Sq. mm (A2XFY) (OD : 45 mm) 73 4C x 185 Sq. mm (A2XFY) (OD : 50 mm) 74 4C x 240 Sq. mm (A2XFY) (OD : 57 mm) 75 4C x 300 Sq. mm (A2XFY) (OD : 59.5 mm) 76 1C x400 Sq. mm (A2XFY/A2XWY) (OD : 34 mm / 36.5 mm) 77 1C x500 Sq. mm (A2XFY/A2XWY) (OD : 37.5 mm / 39.5 mm) 78 1C x630 Sq. mm (A2XWaY) (OD : 43.5 mm) 79 Cable glands suitable for 650 V voltage grade, Cu conductor (stranded / solid), XLPE / PVC insulated, armoured / unarmoured cables for FIRE ALARM AND COMMUNICATION SYSTEM CABLES 80 1P x 0.5 sq.mm (OD : 13.2 mm) 81 2P x 0.5 sq.mm (OD : 16.4 mm) 82 5P x 0.5 sq.mm (OD : 18 mm) 83 10P x 0.5 sq.mm (OD : 21.0 mm) 84 24P x 0.5 sq.mm (OD : 29.5 mm) 85 2P x 1.5 sq.mm (OD : 21.4 mm) 86 12P x 1.5 sq. mm (OD : 32 mm) 87 20P x 1.5 sq.mm 88 50P x 1.5 sq.mm 89 100P x 1.5 sq.mm 90 1P x 2.5 sq.mm(OD : 23.3 mm) 91 8Fibre FO CABLE 92 LV Cable glands for Explosive Atmospheres- Supply of cable glands LV cable glands for Explosive Atmospheres and all the associated accessories as per ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL.- CONTRACTOR shall be responsible selection and supply of exactly suitable cable glands for the actual cables (technical particulars as per project technical specification) installed at site and equipment cable entry tread.OD mentioned below indicate approximate overall cable diameters. 93 Cable glands suitable for 650 / 1100 V (Uo / U) voltage grade, Al / Cu conductor (stranded / solid), XLPE insulated, screened, armoured power / control / lighting cables 94 4 x Pair x 2.5 (OD : 26.6 mm) 95 8 x Tried x 1.5 (OD : 33.2 mm) 96 2C x2.5 Sq. mm (2XWY) (OD : 14 mm) 97 2C x 4 Sq. mm (2XWY) (OD : 15.5 mm) 98 2C x 6 Sq. mm (2XWY) (OD : 16.6 mm) 99 2C x 10 Sq. mm (2XWY) (OD : 18.5 mm) 100 2C x 16 Sq. mm (2XWY/2XFY) (OD : 18.8 mm) 101 3C x2.5 Sq. mm (2XWY) (OD : 14 mm) 102 3C x 4 Sq. mm (2XWY) (OD : 15 mm) 103 3C x 6 Sq. mm (2XWY) (OD : 16.5 mm) 104 3C x 10 Sq. mm (2XWY) (OD : 18.5 mm) 105 3C x 16 Sq. mm (2XWY/2XFY) (OD : 19.7 mm/17.8 mm) 106 4C x2.5 Sq. mm (2XWY) (OD : 15 mm) 107 4C x 4 Sq. mm (2XWY) (OD : 16 mm) 108 4C x 6 Sq. mm (2XWY) (OD : 17.5 mm) 109 4C x 10 Sq. mm (2XWY/2XFY) (OD : 21.8 mm) 110 4C x 16 Sq. mm (2XWY/2XFY) (OD : 22.8 mm/21.2 mm) 111 5C x 2.5 Sq. mm (2XWY) (OD : 16 mm) 112 6C x 2.5 Sq. mm (2XWY) (OD : 17.2 mm) 113 7C x 2.5 Sq. mm (2XWY) (OD : 17 mm) 114 8C x 2.5 Sq. mm (2XWY) (OD : 18.0 mm) 115 10C x 2.5 Sq. mm (2XFY) (OD : 19.5 mm) 116 12C x 2.5 Sq. mm (2XFY) (OD : 22.2 mm) 117 16C x 2.5 Sq. mm (2XFY) (OD : 22.0 mm) 118 24C x 2.5 Sq. mm (2XFY) (OD : 26.7 mm) 119 3C x 25 Sq. mm (A2XFY) (OD : 21 mm) 120 3C x 35 Sq. mm (A2XFY) (OD : 23 mm) 121 3C x 50 Sq. mm (A2XFY) (OD : 26 mm) 122 3C x 70 Sq. mm (A2XFY) (OD : 29 mm) 123 3C x 95 Sq. mm (A2XFY) (OD : 33 mm) 124 3C x 120 Sq. mm (A2XFY) (OD : 36 mm) 125 3C x 150 Sq. mm (A2XFY) (OD : 39.2 mm) 126 3C x 185 Sq. mm (A2XFY) (OD : 45 mm) 127 3C x 240 Sq. mm (A2XFY) (OD : 51 mm) 128 3C x 300 Sq. mm (A2XFY) (OD : 53 mm) 129 4C x 25 Sq. mm (A2XFY) (OD : 22.2 mm) 130 4C x 35 Sq. mm (A2XFY) (OD : 27 mm) 131 4C x 50 Sq. mm (A2XFY) (OD : 30 mm) 132 4C x 70 Sq. mm (A2XFY) (OD : 34 mm) 133 4C x 95 Sq. mm (A2XFY) (OD : 37 mm) 134 4C x 120 Sq. mm (A2XFY) (OD : 41 mm) 135 4C x 150 Sq. mm (A2XFY) (OD : 45 mm) 136 4C x 185 Sq. mm (A2XFY) (OD : 50 mm) 137 4C x 240 Sq. mm (A2XFY) (OD : 57 mm) 138 4C x 300 Sq. mm (A2XFY) (OD : 59.5 mm) 139 1C x400 Sq. mm (A2XFY/A2XWY) (OD : 34 mm / 36.5 mm) 140 1C x500 Sq. mm (A2XFY/A2XWY) (OD : 37.5 mm / 39.5 mm) 141 1C x630 Sq. mm (A2XWaY) (OD : 43.5 mm) 142 3.5C x 150 Sq. mm (A2XFY) 143 3.5C x 300 Sq. mm (A2XFY) 144 Cable glands suitable for 650 V voltage grade, Cu conductor (stranded / solid), XLPE / PVC insulated, armoured / unarmoured cables for FIRE ALARM AND COMMUNICATION SYSTEM CABLES 145 1P x 0.5 sq.mm (OD : 13.2 mm) 146 2P x 0.5 sq.mm (OD : 16.4 mm) 147 5P x 0.5 sq.mm (OD : 18 mm) 148 10P x 0.5 sq.mm (OD : 21.0 mm) 149 24P x 0.5 sq.mm (OD : 29.5 mm) 150 1P x 1.5 sq.mm (OD : 14 mm) 151 2P x 1.5 sq.mm (OD : 21.4 mm) 152 12P x 1.5 sq. mm (OD : 32 mm) 153 20P x 1.5 sq.mm 154 50P x 1.5 sq.mm 155 100P x 1.5 sq.mm 156 1P x 2.5 sq.mm(OD : 23.3 mm) 157 2P x 2.5 sq.mm(OD : 23.3 mm) 158 4P x 2.5 sq.mm(OD : 26.6 mm) 159 12P x 2.5 sq. mm (OD : 38.6 mm) 160 20P x 2.5 sq.mm 161 LV Cable gland reducers / expanders- Supply of LV Cable gland reducers / expanders and all the associated accessories as per ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL.- CONTRACTOR shall be responsible selection and supply of exactly suitable reducers / expanders for the actual cables gland (technical particulars as per project technical specification) installed at site and equipment cable entry tread. 162 LV Cable gland reducers Industrial type 163 M20 x 1.5 (Male thread) to M16 x 1.5 (Female thread) 164 M25 x 1.5 (Male thread) to M20 x 1.5 (Female thread) 165 M32 x 1.5 (Male thread) to M25 x 1.5 (Female thread) 166 M50 x 1.5 (Male thread) to M32 x 1.5 (Female thread) 167 M63 x 1.5 (Male thread) to M50 x 1.5 (Female thread) 168 M80 x 1.5 (Male thread) to M63 x 1.5 (Female thread) 169 LV Cable gland expander Industrial type 170 M16 x 1.5 (Male thread) to M20 x 1.5 (Female thread) 171 M20 x 1.5 (Male thread) to M25 x 1.5 (Female thread) 172 M25 x 1.5 (Male thread) to M32 x 1.5 (Female thread) 173 M32 x 1.5 (Male thread) to M50 x 1.5 (Female thread) 174 M50 x 1.5 (Male thread) to M63 x 1.5 (Female thread) 175 M63 x 1.5 (Male thread) to M80 x 1.5 (Female thread) 176 LV Cable gland reducers for Explosive Atmospheres 177 M20 x 1.5 (Male thread) to M16 x 1.5 (Female thread) 178 M25 x 1.5 (Male thread) to M20 x 1.5 (Female thread) 179 M32 x 1.5 (Male thread) to M25 x 1.5 (Female thread) 180 M50 x 1.5 (Male thread) to M32 x 1.5 (Female thread) 181 M63 x 1.5 (Male thread) to M50 x 1.5 (Female thread) 182 M80 x 1.5 (Male thread) to M63 x 1.5 (Female thread) 183 LV Cable gland expander for Explosive Atmospheres 184 M16 x 1.5 (Male thread) to M20 x 1.5 (Female thread) 185 M20 x 1.5 (Male thread) to M25 x 1.5 (Female thread) 186 M25 x 1.5 (Male thread) to M32 x 1.5 (Female thread) 187 M32 x 1.5 (Male thread) to M50 x 1.5 (Female thread) 188 M50 x 1.5 (Male thread) to M63 x 1.5 (Female thread) 189 M63 x 1.5 (Male thread) to M80 x 1.5 (Female thread) 190 LV Cable lugs- Supply of crimping type lugs for power / control / lighting / earthing cables of various sizes as per ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL.- CONTRACTOR shall be responsible selection and supply of exactly suitable lug for the actual cable conductors for the cables (technical particulars as per project technical specification) installed at site and available termination arrangement. 191 Tinned copper, insulated, Pin type lugs 192 1.5 sq.mm 193 2.5 sq.mm 194 Tinned copper, insulated, Ring type lugs 195 1.5 sq.mm 196 2.5 sq.mm 197 Tinned copper, tubular type, heavy duty lugs for bolted connection 198 4 sq. mm 199 6 sq. mm 200 10 sq. mm 201 16 sq. mm 202 25 sq. mm 203 35 sq.mm 204 50 sq. mm 205 70 sq. mm 206 95 sq. mm 207 120 sq. mm 208 150 sq. mm 209 185 sq. mm 210 240 sq. mm 211 300 sq. mm 212 630 sq. mm 213 Tinned copper, tubular type, long barrel type heavy duty lugs for bolted connection 214 50 sq. mm 215 70 sq. mm 216 95 sq. mm 217 120 sq. mm 218 150 sq. mm 219 185 sq. mm 220 240 sq. mm 221 300 sq. mm 222 630 sq. mm 223 Tinned copper, tubular type, large diameter lugs for bolted connection of earthing conductor 224 6 sq. mm 225 10 sq. mm 226 35 sq.mm 227 95 sq. mm 228 120 sq. mm 229 185 sq. mm 230 8 mm dia. GI wire rope 231 10 mm dia. GI wire rope 232 16 mm dia. GI wire rope 233 Tinned copper, insulated, Pin type lugs (for Paired Cable) 234 0.5 sq.mm 235 1.5 sq.mm 236 2.5 sq.mm 237 Cable entry blanking plugs - Supply of cable entry blanking plugs and all the associated accessories for sealing of unused cable entries, as per ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL.- CONTRACTOR shall be responsible selection and supply of exactly suitable Cable entry blanking plugs as per equipment cable entry tread at site. 238 Cable entry blanking plugs Industrial type 239 M16 (OD 13mm) 240 M20 ( OD 19.5 MM) 241 M25 ( OD 25.5mm) 242 M32 (OD 32.9mm) 243 M50 (OD 51mm) 244 M63 (OD 59mm) 245 Cable entry blanking plugs For Explosive Atmospheres 246 M16 (OD 13mm) 247 M20 ( OD 19.5 MM) 248 M25 ( OD 25.5mm) 249 M32 (OD 32.9mm) 250 M50 (OD 51mm) 251 M63 (OD 59mm) 252 CABLE JOINTING 253 Cable straight through jointing kit indoor type- Supply of cable jointing kit along with all the associated accessories as per ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL. 254 HV Cable straight through jointing kit Heat shrinkable type (suitable for indoor installation) for 33 / 33 kV (UE) voltage grade, Al conductor, XLPE insulated, screened, armoured power cable 255 1C x 630 sq.mm A2XCEWaY (UE) 256 PREFABRICATED CABLE TRAYS 257 Prefabricated Cable Trays (GI)- Supply of prefabricated GI perforated and ladder type cable tray / covers, tray separators along with all the associated consumable material for assembly and appropriate installation of the same, as per doc. no. TK-1ZZZA-EL-SPE-0016 (Technical Specification for GI cable Trays) 258 Cable Trays Perforated (GI) (Length 3 mtr per piece) including required hardware as per Installation dwg 259 50 mm wide 260 100 mm wide 261 150 mm wide 262 Coupler plates along with SS304 fixing hardware 263 GI Coupler plates with 3 mm thick, 4 holes on both the sides of size M10 hole & M8 hardware (along with necessary fixing hardware –stainless steel (SS304) nut, bolt, lock-nut) for 50/100/150 W perforated cable trays mentioned above. (Note : 1 no. set = 2 nos. coupler plates each) 264 Stainless Steel Coupler plates with 2 mm thick, 4 holes on both the sides of size M10 hole & M8 hardware (along with necessary fixing hardware –stainless steel (SS304) nut, bolt, lock-nut) for 50/100/150W perforated cable trays mentioned above. (Note : 1 no. set = 2 nos. coupler plates each) 265 Tray Covers (length 3 mtr per piece) with fixing clamps (at every 1 meter) along with necessary SS304 hardware 266 150 mm wide 267 100 mm wide 268 Cable Ladders (GI) (Length 3 mtr per piece) 269 150 mm wide 270 300 mm wide 271 600 mm wide 272 Pre-Fabricated 90 degree horizontal bends (Bending Radius 300mm) 273 300 mm wide 274 600 mm wide 275 Pre-Fabricated 90 degree horizontal bends (Bending Radius 600mm) 276 300 mm wide 277 600 mm wide 278 Pre-Fabricated 90 degree horizontal bends (Bending Radius 1200mm) 279 300 mm wide 280 600 mm wide 281 Pre-Fabricated 90 degree Inside Vertical bends (Bending Radius 300mm) 282 600 mm wide 283 Pre-Fabricated 90 degree Inside Vertical bends (Bending Radius 600mm) 284 300 mm wide 285 600 mm wide 286 Pre-Fabricated 90 degree Inside Vertical bends (Bending Radius 1200mm) 287 300 mm wide 288 Pre-Fabricated 90 degree Outside Vertical bends (Bending Radius 300mm) 289 600 mm wide 290 Pre-Fabricated 90 degree Outside Vertical bends (Bending Radius 600mm) 291 300 mm wide 292 600 mm wide 293 Pre-Fabricated 90 degree Outside Vertical bends (Bending Radius 1200mm) 294 300 mm wide 295 Pre-Fabricated 45 degree horizontal bends (Bending Radius 300mm) 296 300 mm wide 297 600 mm wide 298 Pre-Fabricated 45 degree horizontal bends (Bending Radius 600mm) 299 300 mm wide 300 600 mm wide 301 Pre-Fabricated 45 degree horizontal bends (Bending Radius 900mm) 302 300 mm wide 303 600 mm wide 304 Pre-Fabricated 45 degree Inside Vertical bends (Bending Radius 300mm) 305 300 mm wide 306 600 mm wide 307 Pre-Fabricated 45 degree Inside Vertical bends (Bending Radius 600mm) 308 300 mm wide 309 600 mm wide 310 Pre-Fabricated 45 degree Inside Vertical bends (Bending Radius 900mm) 311 300 mm wide 312 600 mm wide 313 Pre-Fabricated 45 degree Outside Vertical bends (Bending Radius 300mm) 314 300 mm wide 315 600 mm wide 316 Pre-Fabricated 45 degree Outside Vertical bends (Bending Radius 600mm) 317 300 mm wide 318 600 mm wide 319 Pre-Fabricated 45 degree Outside Vertical bends (Bending Radius 900mm) 320 300 mm wide 321 600 mm wide 322 Pre Fabricated Cable Tray Reducer 323 600 to 300 mm Reducer, Right Hand Side 324 600 to 300 mm Reducer, Left Hand Side 325 300 to 150 mm Reducer, Right Hand Side 326 300 to 150 mm Reducer, Left Hand Side 327 Pre Fabricated Equal Tee’s (Bending Radius-300 mm) 328 600 mm wide 329 Pre Fabricated Equal Tee’s (Bending Radius-600 mm) 330 300 mm wide 331 Pre Fabricated Equal Tee’s (Bending Radius-900 mm) 332 300 mm wide 333 600 mm wide 334 Pre Fabricated Unequal Tee’s (Bending Radius-300 mm) 335 300 x 150 x 300 mm wide 336 600 x 150 x 600 mm wide 337 600 x 300 x 600 mm wide 338 Pre Fabricated Unequal Tee’s (Bending Radius-600 mm) 339 300 x 150 x 300 mm wide 340 600 x 150 x 600 mm wide 341 600 x 300 x 600 mm wide 342 Coupler plates along with SS304 fixing hardware 343 GI Coupler plates with 3 mm thick, 4 holes on both the sides of size M10 hole & M8 hardware (along with necessary fixing hardware –stainless steel nut, bolt, lock-nut) for 150/300/450/600 W ladder type cable trays mentioned above. (Note : 1 no. set = 4 nos. coupler plates each) 344 Stainless Steel Coupler plates with 2 mm thick, 4 holes on both the sides of size M10 hole & M8 hardware (along with necessary fixing hardware –stainless steel nut, bolt, lock-nut) for 150/300/450/600W ladder type cable trays mentioned above. (Note : 1 no. set = 4 nos. coupler plates each) 345 Hinged GI plates for below bends with 3 mm thick, 4 holes on both the sides of size M10 hole & M8 hardware (along with necessary fixing hardware –stainless steel (SS304) nut, bolt, lock-nut) for 150/300/450/600W ladder type cable trays mentioned above. (Note : 1 no. set = 4 nos. coupler plates each) 346 Hinged GI plates for Horizontal 45 degree bends 347 Hinged GI plates for Vertical 45 degree bends 348 Clamps for fixing 45 degree Horizontal & Vertical Cable Tray cover along with necessary fixing hardware –stainless steel (SS304) nut, bolt, lock-nut for ladder type cable trays mentioned above. 349 Clamps for 300 mm wide tray 350 Clamps for 600 mm wide tray 351 Cable Tray Covers (GI) (Length 3 mtr per piece) 352 150 mm wide 353 300 mm wide 354 600 mm wide 355 Pre Fabricated Tray Cover for Horizontal 900 Bends (Bending Radius-300 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware 356 300 mm wide 357 Pre Fabricated Tray Cover for Horizontal 900 Bends (Bending Radius-600 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware 358 300 mm wide 359 600 mm wide 360 Pre Fabricated Tray Cover for Horizontal 900 Bends (Bending Radius-900 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware 361 300 mm wide 362 Pre Fabricated Tray Cover for Horizontal 900 Bends (Bending Radius-1200 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware 363 300 mm wide 364 600 mm wide 365 Pre Fabricated Tray Cover for Inside Vertical 900Bends (Bending Radius-300 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware 366 600 mm wide 367 Pre Fabricated Tray Cover for Inside Vertical 900Bends (Bending Radius-600 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware 368 300 mm wide 369 600 mm wide 370 Pre Fabricated Tray Cover for Inside Vertical 900Bends (Bending Radius-900 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware 371 300 mm wide 372 Pre Fabricated Tray Cover for Inside Vertical 900Bends (Bending Radius-1200 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware 373 300 mm wide 374 Pre Fabricated Tray Cover for Outside Vertical 900Bends (Bending Radius-300 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware 375 600 mm wide 376 Pre Fabricated Tray Cover for Outside Vertical 900Bends (Bending Radius-600 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware 377 300 mm wide 378 600 mm wide 379 Pre Fabricated Tray Cover for Outside Vertical 900Bends (Bending Radius-900 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware 380 300 mm wide 381 Pre Fabricated Tray Cover for Outside Vertical 900Bends (Bending Radius-1200 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware 382 300 mm wide 383 Pre Fabricated Tray Cover for Horizontal 450Bends (Bending Radius-300 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware 384 300 mm wide 385 600 mm wide 386 Pre Fabricated Tray Cover for Horizontal 450Bends (Bending Radius-600 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware 387 300 mm wide 388 600 mm wide 389 Pre Fabricated Tray Cover for Horizontal 450Bends (Bending Radius-900 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware 390 300 mm wide 391 600 mm wide 392 Pre Fabricated Tray Cover for inside Vertical 450Bends (Bending Radius-300 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware 393 300 mm wide 394 600 mm wide 395 Pre Fabricated Tray Cover for inside Vertical 450Bends (Bending Radius-600 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware 396 600 mm wide 397 Pre Fabricated Tray Cover for inside Vertical 450Bends (Bending Radius-900 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware 398 300 mm wide 399 600 mm wide 400 Pre Fabricated Tray Cover for Outside Vertical 450Bends (Bending Radius-300 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware 401 300 mm wide 402 600 mm wide 403 Pre Fabricated Tray Cover for Outside Vertical 450Bends (Bending Radius-600 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware 404 300 mm wide 405 600 mm wide 406 Pre Fabricated Tray Cover for Outside Vertical 450Bends (Bending Radius-900 mm) with 2 nos. fixing clampsalong with necessary SS304 hardware 407 300 mm wide 408 600 mm wide 409 Pre Fabricated Tray Cover for Cable Tray Reducer with 2 nos. fixing clampsalong with necessary SS304 hardware 410 600 to 300 mm Reducer, Right Hand Side 411 600 to 300 mm Reducer, Left Hand Side 412 300 to 150 mm Reducer, Right Hand Side 413 300 to 150 mm Reducer, Left Hand Side 414 Pre Fabricated Tray Cover for Equal Tee’s (Bending Radius-300 mm) with 3 nos. fixing clampsalong with necessary SS304 hardware 415 600 mm wide 416 Pre Fabricated Tray Cover for Equal Tee’s (Bending Radius-600 mm) with 3 nos. fixing clampsalong with necessary SS304 hardware 417 300 mm wide 418 600 mm wide 419 Pre Fabricated Tray Cover for Equal Tee’s (Bending Radius-900 mm) with 3 nos. fixing clampsalong with necessary S3304 hardware 420 300 mm wide 421 600 mm wide 422 Pre Fabricated Tray Cover for Unequal Tee’s(Bending Radius-300 mm) with 3 nos. fixing clampsalong with necessary SS304 hardware 423 300 x 300 x 150 mm wide 424 600 x 600 x 150 mm wide 425 600 x 600 x 300 mm wide 426 Pre Fabricated Tray Cover for Unequal Tee’s (Bending Radius-600 mm) with 3 nos. fixing clampsalong with necessary SS304 hardware 427 300 x 300 x 150 mm wide 428 600 x 600 x 150 mm wide 429 600 x 600 x 300 mm wide 430 Z Clamps for Holding Horizontal Cable Tray, Material - HDGI, thickness - 2 mm with necessary fixing hardware with (with M12 hole & M10 hardware SS304 nut, bolt, lock-nut) 431 Separators for Cable Ladders (GI) 432 300 mm / 600 mm wide 433 CONDUITS FOR CABLE LAYING / PROTECTION AND PULL BOXES- Supply of heavy duty rigid GI / PVC conduits and all the associated accessories - Supply of accessories such as GI clamps, joints, bends reducers / adaptors for the conduits and other consumable material such as edge protection grommet at either ends for GIconduits as per the site requirement is considered in running meter length of the conduits. 434 Rigid GI conduits 435 25 mm nominal dia 436 50 mm nominal dia 437 150 mm nominal dia 438 Rigid GI conduits RED coloured (For Fire Alarm System cables) 439 25 mm nominal dia 440 50 mm nominal dia 441 Heavy duty PVC conduits 442 150 mm nominal dia 443 Flexible PVC conduits 444 20 mm nominal dia 445 Pull boxes for cable pulling in conduitsSupply of pull boxes (GI enclosure) 446 4 way Pull boxes,100mm L x 100mm Wx 75mm D,1no. 25mm knockout on all four sides 447 4 way Pull boxes, 115mm L x 115mm Wx 75mm D,2nos. 25 mm knockout on all four sides 448 4 way Pull boxes, 265mm L x 165mm Wx 75mm D, 5nos. 25mm knockout at top / bottom and 2nos. 25mm knockout on each sides. 449 LIGHTING, SMALL POWER, WELDING SOCKETS AND JUNCTION BOXES 450 LIGHTING 451 Lighting fixturesSupply of lighting fixtures and associated components / accessories such as lamps, chokes, condensers, reflectors, control gear box for non-integral fixtures etc. as per doc. no. TK-1ZZZA-EL-SPE-0019 (Technical Specification for Industrial Light Fixture) and TK-1ZZZA-EL-SPE-0020 (Technical Specification for Flameproof Light Fixture) 452 Lighting Fixtures for Explosive Atmospheres 453 40W LED Ex-d FLP Well Glass Light Fixture 454 100W LED Ex-d FLP Medium Bay Light Fixture 455 150W LED Ex-d FLP Flood Light fixture 456 20W LED Ex-d FLP Aviation Light 457 26W, 110V DC LED Ex-d FLP Well Glass Fixture 458 Special Lighting fixturesSupply of special lighting fixtures and all the associated accessories, as per ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL. 459 Emergency lighting fixture with built-in battery 460 1x18W, Fluorescent, Industrial 461 1x18W, Fluorescent, for Explosive Atmospheres 462 Hand lamps 463 24V Hand lamps for Explosive Atmospheres along with 20m extension cable 3c x 1.5sq.mm, YY, 20m, along with the plug suitable for 24V, 5A Industrial switch socket 464 SMALL POWERSupply of various small power equipment and all associated accessories, as per ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL. 465 Industrial type switch socket outlets (for Indoor Installation) 466 10A, single phase socket outlet with 1no. 3 pin socket, in sheet steel enclosure 467 10A, single phase socket outlet with 1 No. 10 A, 10 kA, SPMCB, in sheet steel enclosure 468 10A, single phase switch socket outlet with 1no. 3 pin socket and 1 No. 10 A, 10 kA, SPMCB, in sheet steel enclosure 469 20A, single phase socket outlet with 1no. 3 pin socket, in sheet steel enclosure 470 20A, single phase socket outlet with 1 No. 20 A, 10 kA, SPMCB, in sheet steel enclosure 471 20A, single phase switch socket outlet with 1no. 3 pin socket and 1 No. 20 A, 10 kA, SPMCB, in sheet steel enclosure 472 Convenience Switch socket outlets 473 Conveniencesockets (single phase) for Explosive Atmospheres 474 16A, 3 pin,240V AC single phase socket outlet with DPMCB in die cast Al LM6 enclosure, Type S01 475 Switch socket unit (portable) for Explosive Atmospheres 476 240V,16A and 24V, 5A combination type switch socket unit for Explosive Atmospheres, with built-in 100VA, 240V / 24V transformer 477 JUNCTION BOXES (JB) / POWER JUNCTION BOXES (JB)- Supply of various types of junction boxes / power junction boxes suitable for the required cable entries and all associated accessories, as per doc. no.TK-1ZZZA-EL-SPE-0017 (Technical specification for Industrial Equipment) and TK-1ZZZA-EL-SPE-0018 (Technical Specification for Flameproof Equipment)- Supply of junction boxes suitable for bottom entry of incoming and outgoing cables, inclusive of suitable terminals for undrilled gland plate, cable terminations, busbars for cable termination as required, facility for earthing cable termination inside and outside the termination, along with the associated accessories such plugs for cable openings, fixing hardware 478 Junction boxes Industrial type 479 Junction boxes (Outdoor) 480 4 way Welding socket JB, Outdoor 481 Communication Junction Boxes 482 Outdoor PA System JB for SpeakersIncoming : 12Px2.5 sq.mm(1 No.) - M40Outgoing : 2Px2.5 sq.mm(12 Nos.) - M25 (9 Nos. Gland + 3 Nos. Plug) 483 Indoor Telephone System JB (IDF)Incoming : 12Px2.5 sq.mm(1 No.) - M40Outgoing : 2Px2.5 sq.mm(12 Nos.) - M25 (9 Nos. Gland + 3 Nos. Plug) 484 Junction boxes for Explosive Atmospheres 485 Junction boxes 486 4 way Lighting JB, Ex-d 487 5 way JB for small power sockets, Ex-d 488 4 way Welding socket JB, Ex-d 489 For 30 kW Motor with Incoming cable size 1R-3Cx120sq.mm and outgoing cable size 1R-3Cx50sq.mm 490 For 30 kW Motor with Incoming cable size 1R-3Cx150sq.mm and outgoing cable size 1R-3Cx95sq.mm 491 For 30 kW Motor with Incoming cable size 1R-3Cx185sq.mm and outgoing cable size 1R-3Cx95sq.mm 492 For 37 kW Motor with Incoming cable size 1R-3Cx185sq.mm and outgoing cable size 1R-3Cx95sq.mm 493 For 37 kW Motor with Incoming cable size 1R-3Cx240sq.mm and outgoing cable size 1R-3Cx95sq.mm 494 For 45kW Motor with Incoming cable size 1R-3Cx240sq.mm and outgoing cable size 1R-3Cx95sq.mm 495 For 110kW Motor with Incoming cable size 3R-3Cx240sq.mm and outgoing cable size 2R-3Cx240sq.mm 496 For 132kW Motor with Incoming cable size 4R-3Cx240sq.mm and outgoing cable size 2R-3Cx240sq.mm 497 Power JB for Instrumentation Benzene Analyser & sulphur analyser :Incoming cable size 1R-2Cx185sq.mm and outgoing cable size 1R-2Cx50sq.mm -GDS Area 498 Welding Socket JB : 1P25-WJB-0001 , 1P25-WJB-0002, 1P25-WJB-0003Incoming power cable : 1R-4Cx240sq.mmOutgoing power cable : 4R- 4Cx35sq.mm 499 Communication Junction boxes 500 Indoor FA System JB for housing addressable module of 1 no. MCPIncoming : 2Px1.5 (1 No.)Outgoing : 2Px1.5 (1 No.), 1Px1.5 (1 Nos.)NPT thread glands : 3 Nos.Plugs : 2 Nos. (Plug for 2Px1.5 size) 501 Outdoor FA System JB for housing addressable module of 1 no. MCPIncoming : 2Px1.5 (1 No.)Outgoing : 2Px1.5 (1 No.), 1Px1.5 (1 Nos.)NPT thread glands : 3 Nos.Plugs : 2 Nos. (Plug for 2Px1.5 size) 502 Outdoor FA System JB for housing addressable module of 1 no. Hooter / BeconIncoming : 2Px1.5 (1 No.)Outgoing : 2Px1.5 (1 No.), 1Px2.5 (1 Nos.)NPT thread glands : 3 Nos.Plugs : 2 Nos. (Plug for 2Px1.5 size) 503 Outdoor FA System JB for housing addressable module of 1 no. DetectorIncoming : 2Px1.5 (1 No.)Outgoing : 2Px1.5 (1 No.), 1Px1.5 (1 Nos.)NPT thread glands : 3 Nos.Plugs : 2 Nos. (Plug for 2Px1.5 size) 504 Outdoor FA System JB for Housing 2 addressable modules and 2 zener barrierIncoming : 2Px1.5 (1 No.)Outgoing : 2Px1.5 (1 No.), 1Px1.5 (2 Nos.)NPT thread glands : 4 Nos.Plugs : 2 Nos. (Plug for 2Px1.5 size) 505 Outdoor FA System JB for End of resistor / Fault Isolator in FA loopIncoming : 2Px1.5 (1 No.)Outgoing : 2Px1.5 (1 No.)NPT thread glands : 2 Nos.Plugs : 2 Nos. (Plug for 2Px1.5 size) 506 Outdoor Telephone System JB (IDF)Incoming : 10Px0.63 mm dia (1 No.)Outgoing : 5Px0.63 mm dia (5 Nos.) NPT thread glands : 6 Nos.Plugs : 3 Nos. (1 No. Plug for 10Px0.63 mm dia & 2 Nos. plugs for 5Px0.63 mm dia) 507 Outdoor PA System JB for FCSIncoming : 12Px1.5 (1 No.)Outgoing : 2Px1.5 (6 Nos.) NPT thread glands : 7 Nos.Plugs : 2 Nos. (1 No. Plug for 12Px1.5 and 1 No. for 2Px1.5) 508 Outdoor PA System JB for SpeakersIncoming : 12Px2.5 (1 No.)Outgoing : 2Px2.5 (12 Nos.) NPT thread glands : 13 Nos.Plugs : 3 Nos. (1 No. Plug for 12Px2.5 and 2 Nos. for 2Px2.5) 509 Indoor PA System JB for SpeakersIncoming : 12Px2.5 (1 No.)Outgoing : 2Px2.5 (12 Nos.) NPT thread glands : 13 Nos.Plugs : 3 Nos. (1 No. Plug for 12Px2.5 and 2 Nos. for 2Px2.5) 510 Installation Material for Junction boxes (wall / concrete / steel structure mounted) - Supply of all the Installation Material (excluding structural steel) for Junction boxes (wall / concrete / steel structure mounted) as per Installation Details - Power and applicable construction documents, including any additional material as per site requirement so as to ensure the completeness of installation work- Supply of steel support structure / supporting frames for above shall be considered separately in SECTION - F. 511 Installation Type : L08A 512 Installation Type : L08C 513 Installation Type : P10A 514 Installation Type : P10B 515 Installation Type : P10B 516 Installation Type : P17 517 Installation Type : P10A/P10B 518 POWER SOCKET OUTLETSSupply of various types of power socket outlets and all associated accessories, as per ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL. 519 Power Socket Outlets for Explosive Atmospheres 520 For Explosive Atmospheres, 415V, 63A, TPN & E socket outlet, with die cast Al LM6 enclosure, Type WS3 521 For Explosive Atmospheres, 415V, 100A, TPN & E socket outlet, with die cast Al LM6 enclosure, Type WS4 522 Installation Material for Power socket outlets (wall / concrete / steel structure mounted) - Supply of all the Installation Material (excluding structural steel) for Power socket outlets (wall / concrete / steel structure mounted) as per Installation Details - Power and applicable construction documents, including any additional material as per site requirement so as to ensure the completeness of installation work- Supply of steel support structure / supporting frames for above shall be considered separately in SECTION - F. 523 Installation Type : P10A (63A) On Concrete 524 Installation Type : P10A (63A) On Steel 525 Installation Type : P10B (63A) On Steel 526 Installation Type : P15 (63A) 527 Installation Type : P10A (100A) on Concrete 528 Installation Type : P10A (100A) on Steel 529 Installation Type : P10B (100A) on Steel 530 FIRE ALARM AND COMMUNICATION SYSTEMS 531 FIRE ALARM (FA) SYSTEM- Supply of all the Installation Material (excluding structural steel) for FA system equipment and associated accessories as per applicable construction documents, including any additional material as per site requirement so as to ensure the completeness of installation work- Supply of steel support structure / supporting frames for above shall be considered separately in SECTION - F. 532 FA system accessories (Industrial / For Explosive Atmospheres) 533 Installation Type: FAHC1 534 Installation Type: FAHS1 535 Installation Type: FASC1 536 Installation Type: FASC2 537 Installation Type: FASS1 538 Installation Type: FCPC1 539 Installation Type: FCPP1 540 Installation Type: FCPP2 541 Installation Type: FCPR1 542 Installation Type: FCPS1 543 Installation Type: FMDC1 544 Installation Type: FMDF3 545 Installation Type: FMDS1 546 Installation Type: FCPS2 547 Installation Type: CFBC1 548 Installation Type: CFBS1 549 Junction boxesInstallation shall be as per Installation Details - Lighting and applicable construction documents. 550 Installation Type: L08C 551 PUBLIC ADDRESS (PA) SYSTEM- Supply of all the Installation Material (excluding structural steel) for PA system equipment and associated accessories as per Installation standards- Communication & PA System and applicable construction documents, including any additional material as per site requirement so as to ensure the completeness of installation work- Supply of steel support structure / supporting frames for above shall be considered separately in SECTION - F. 552 PA system accessories (For Industrial / Explosive Atmospheres) 553 Installation Type: CTFC2 554 Installation Type: CTFR1 555 Installation Type: CTFR2 556 Installation Type: CTFS2 557 Installation Type: CTFS3 558 Installation Type: CFBR1 559 Installation Type: CFBS1 560 Installation Type: CSPKP1 561 Installation Type: CSPKS1 562 Installation Type: CSPKR1 563 Installation Type: CMCS1 564 Junction boxesInstallation shall be as per Installation Details - Lighting and applicable construction documents. 565 Installation Type: L08B 566 Installation Type: L08C 567 Installation Type: L08D 568 Installation Type: L08F 569 TELEPHONE SYSTEMSupply of all the Installation Material (excluding structural steel) for Telephone system equipment and associated accessories as per Installation standards- Communication & PA System and applicable construction documents, including any additional material as per site requirement so as to ensure the completeness of installation work 570 Telephone system accessories (For Industrial / Explosive Atmospheres) 571 Installation Type: CTFC1 572 Installation Type: CTFC2 573 Installation Type: CTFR1 574 Installation Type: CTFR2 575 Installation Type: CTFS1 576 Installation Type: CTFS2 577 Installation Type: CTFS3 578 Installation Type: CTFC3 579 Installation Type: CFBC1 580 Installation Type: CFBS1 581 Installation Type: CSPKC1 582 Installation Type: CSPKS1 583 Junction boxesInstallation shall be as per Installation Details - Lighting and applicable construction documents. 584 Installation Type: L08B 585 CCTV SYSTEMSupply of all the Installation Material (excluding structural steel) for CCTV system equipment and associated accessories as per Installation standards- Communication & PA System and applicable construction documents, including any additional material as per site requirement so as to ensure the completeness of installation work 586 CCTV system accessories (For Industrial / Explosive Atmospheres) 587 Installation Type: CTVS1 588 Junction boxesInstallation shall be as per Installation Details - Lighting and applicable construction documents. 589 Installation Type: L08C 590 Installation Type: L08G 591 EARTHING AND LIGHTNING PROTECTION 592 EARTHING MATERIAL 593 Earthing conductor Supply of GI strip / bare copper conductor for earthing 594 50 x 6 mm GI strip 595 75 x 10 mm GI strip 596 8 SWG SOLID G.I. WIRE 597 10 MM (3/8) DIA G.I WIRE ROPE 598 16 MM (5/8) DIA G.I WIRE ROPE 599 1C x 95 Sq.mm Cu Cable 600 1C x 10 Sq.mm Cu Cable 601 Earth / lightning protection electrodesSupply of Earth / lightning protection electrodes along with the associated accessories / material as per Installation Details - Earthing, including any additional hardware as per site requirement so as to ensure the completeness of installation work 602 Installation Type : E01A :100 mm Dia, 3 m length GI pipe earth electrode for Electrical Safety earth 603 Installation Type : E01B : 100 mm Dia, 6 m length GI pipe earth electrode for Instrument clean earth 604 Installation Type : E01A : 100 mm Dia, 3 m length GI pipe lightning protection electrode 605 Earth buses- Supply of Earth buses along with the associated accessories (excluding structural steel) as per Installation Details - Earthing and applicable construction documents, including any additional material as per site requirement so as to ensure the completeness of installation work- Supply of steel support structure / supporting frames for above shall be considered separately in SECTION - F. 606 Installation Type : E02A GI earth bus for Electrical safety 607 Installation Type : E02B - GI earth bus for instruments 608 Installation Type : E20 - Mounted on cable tray for Electrical 609 Installation Type : E20 - Mounted on cable tray for Instrumentation 610 LIGHTNING PROTECTION MATERIAL 611 Lightning protection conductor - Supply of GI strip / bare copper conductor/aluminium/HDGI Round conductor for Lightning protection and associated accessories- Supply of accessories such as test links, cross connectors, parallel connectors for lightning protection down conductors, epoxy insulator supports and the associated accessories as perInstallation Details - Lightning Protection / as indicated in applicable construction documents / as per the site requirement, are considered in running meter length oflightning protection down conductors. 612 Installation Type: E16 Roof Conductor (Conductor Size- 25x6mm) 613 Installation Type: E16 Down Conductor (Conductor Size- 25x6mm) 614 Test Link : E16 : 50x6mm GI Link 150mm Long 615 STRUCTURAL STEEL- Supply of structural steel- The quantity of structural steel indicated below is matching with the quantity of steel indicated in SECTION-F of doc. BILL OF QUANTITIES -INSTALLATION (ELECTRICAL). - Section wise requirement shall be estimated by CONTRACTOR, as per the applicable construction documents / various applicable Installation Details mentioned in SECTIONS - A to E in this document.- Measurement of steel quantity for installation shall be based on actual quantities installed at site without wastage allowance. 616 Structural steel (MS)Supply of coating material and paint as required for surface preparation and painting of steel shall be as per doc. TP-1ZZZA-PI-SPE-0003 (Technical Specification for Painting) is included in scope. 617 Structural steel (Hot deep galvanized GI) 618 MISCELLANEOUS ITEMS 619 CANOPIES- Supply of GI / FRP canopies for various equipment and all associated accessories, as per ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL.- Site visit as required to confirm the actual dimensions / arrangement of various equipment installed at site, so as to fabricate canopy exactly suitable for the equipment is considered in the scope.- Supply of all the Installation Material (including steel supporting frame as required) required as per site requirement is included in the scope. 620 Canopies for Motors 621 GI canopy complete with louvers backed up by wire mesh 622 Upto 3.0 kW 623 3.7 kW to 15 kW 624 18.5 kW to 37.0 kW 625 45.0 kW to 90 kW 626 110 kW to160 kW 627 HV (6.6kV) Motors 628 200 kW 629 730 kW 630 CIVIL WORK 631 Anchor fasteners- Supply of anchor fasteners for supporting various equipment in brick work / concrete work, as per ANNEXURE-II to SCC - SCOPE OF SUPPLY - ELECTRICAL.- Supply of anchor fasteners indicated below excludes those already considered in various Installation Details mentioned in SECTIONS - A to E in this document. 632 Anchor fasteners M8 type x 60mm 633 Anchor fasteners M10 type x 75 mm 634 Anchor fasteners M12 type x 100 mm 635 Supply of certified soft sand of known resistivity, red coloured concrete tiles of appropriate voltage grade for cable protection, ordinary bricks, warning tapes, cable markers (including steel & RFID tag) 636 Certified soil (soil resistivity 150 0C/cm/W)) 637 SAFETY ITEMSSupply of safety items as per applicable statutory requirements / HSE documents / as indicated in applicable construction documentsALL SAFETY ITEMS SHALL BE OF REPUTED MAKE & SHALL HAVE PROVENPAST TRACK RECORD. LOCAL MAKES ARE NOT ACCEPTABLE 638 Fire proof painting for cables for 3 m length at entry points of both ends
|