Tender For Additional / Alternator To Building No P-1226 At Af Stn Bhuj; 1 Taking down chowkhat or frames n exc 1.5 sqm each complete all as specified and directed by Engineer-in-Charge. 2 Taking down chowkhat or frames with shutter (without taking off shutters from the frames) exc 1.5 sqm but n.exc 4.00 sqm each complete all as specified and directed by Engineer-in-Charge. 3 Supply & fix anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engineer-in-Charge 4 Supply & fix anodised aluminium door / window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, complete all as specified and as directed byEngineer-in-Charge. 5 Supply & fix anodised aluminium grill( anodised transparent or dyed to required shade according to IS:1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with CP brass/ stainless steel screws @ 200 mm c/c, incl cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and as directed byEngineer-in-Charge. 6 Supply & fix tinted glass exc 0.5 sq. m in each pane 5.50mm thick fixed in aluminium doors/windows complete all as specified and as directed byEngineer-in-Charge.. 7 Supply & fix galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed byEngineer-in-Charge.. 8 Taking down cement plaster on brick, PCC block or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. and removing rubbish outside MD land complete all as specified and as directed byEngineer-in-Charge. 9 Material & labour for rendering 15mm thickin cement sand mortar 1:4 on fair faces of brick work, PCC block masonry or concrete surfaces, mixed with water proofing compound as per manufacturers instructions complete all as specified and as directed byEngineer-in-Charge.(Note:- Supply only Integral water proofing compound will be measured and paid seperately) 10 Supply only integral water proofing compound complete all as specified and as directed byEngineer-in-Charge. 11 Dismantling stone slabsand tiles of laid bedded and pointed in any mortar any description or thickness in floors, aprons etc complete all as specified and directed by Engineer-in-Charge. 12 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as specified and directed by Engineer-in-Charge. 13 Dismantling of wrought ironor mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-charge. 14 Material & labour for treating the surface of existing kota stone/granite floring with bees-wax polish complete all as specified and directed by Engineer-in-Charge. 15 Material & labour for granite (of any type) tiles 18 to 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed by Engineer-in-Charge.Note:- Tread for staircase shall be provided in single piece to full length and width. 16 Material & labour for 18 to 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed by Engineer-in-Charge.Note:- Riser for staircase shall be provided in single piece to full length and width. 17 Material & labour for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed by Engineer-in-Charge. 18 Material & labour for rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 to receive tiles etc on vertical surface of walls complete all as specified and directed by Engineer-in-Charge. 19 Material & labour for Glazed ceramic coloured tiles in vertical surfaces such as in skirting and dados 350x250x7mm/ 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge. 20 Material & labour for coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchcomplete all as specified and directed by Engineer-in-Charge. 21 Material & labour for 18 to 20mm thick granite (of any type) work (table rubbed and polished) over cooking platforms, WHB stand and like laid over 12mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment of match with shade of granite,complete all as specified and directed by Engineer-in-ChargeNote:Granite for kitchen platform shall be in single piece to full length and width 22 Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed by Engineer-in-ChargeNote:Design of railing as approved by GE. 23 Material & Labour for providing and fixing stainless steel (Grade 304) balusters of appropriate height with all necessary futtungs & fixtures and all necessary arrangement for fixing toughened glasses in between complete all as specified and directed by Engineer-in-ChargeNote:Design of Balusters as approved by GE 24 Demolition of block work built in cement morter or cement lime mortar complete all as specified and directed by Engineer-in-Charge. 25 Material & labour for PCC block masonry with precast cement concrete type 1:3:6 (using 20mm graded stone aggregate)solid blocks exc 10cm in width and setting in cement mortar 1:6 complete all as specified and directed by Engineer-in-charge 26 Material & labour for TMT bars 6 to 8mm dia cut to length,bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed)not less than 0.90mm dia complete all as specified and directed by Engineer-in-Charge. 27 Material & labour for reinforced cement concrete nominal mix) in type B1, 1:2:4 (using 20 mm graded stone aggregate) chajja slabs supported on walls, beams and columns in floors, roofs, landings, balconies,canopies, deck slabs and in shelves. 28 Material & labour for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engineer-in-Charge. 29 Supply & fix GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, fixing with galvanised steel staples, MS flat, nuts and boltfixed to walls, steel members incl cutting and waste complete all as specified and directed by Engineer-in-Charge. 30 Material & labour for rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces,, finished even and smooth without using extra cemen complete all as specified and directed by Engineer-in-Charge. 31 Material & labour for rendering 5mm thick in CM 1:3 on fair faces of brick work or concrete surfaces on ceiling,, finished even and smooth without using extra cemen complete all as specified and directed by Engineer-in-Charge. 32 Material & labour for preparation of new surfaces of internal walls surfaces and applying two coat of oil bound distemper over a coat of alkaline resistant primer complete all as specified and as directed byEngineer-in-Charge. 33 Material & labour for complete removal of existing treatment onold surfaces of ceiling surfaces and applying two coats of oil bound distemper over a coat of aklkalia resistant primer complete all as specified and directed by Engineer-in-Charge. 34 Supply & fix solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, single side prelam PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with prelam sheet suppling & fixing in opening as per specification & drawing complete all as specified and directed by Engineer-in-Charge. 35 Supply & fix factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face complete all as specified and directed by Engineer-in-Charge. 36 Supply & fix 18mm thick prelaminated PVC celuka Ply prelaminated one sidewith decorative choice lamination and other side plain fixed with screw to PVC celuka ply works etc complete all as specified and directed by Engineer-in-Charge. 37 Supply & fix 300mm length of bolt aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cost aluminium alloy complete all as specified and directed by Engineer-in-Charge. 38 Supply & fix 100mm size of hinges butt hinges, medium weight, cold rolled stainless steel and fixed complete all as specified and directed by Engineer-in-Charge. 39 Supply & fix 75mm size of hinges butt hinges, medium weight, cold rolled mild stee and fixed complete all as specified and directed by Engineer-in-Charge. 40 Supply & fix 150mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer-in-Charge. 41 Supply & fix 75 mm size stainless steel handles fabricated type complete all as specified and directed by Engineer-in-Charge 42 Supply & fix aluminium, anodised barrel tower bolt of extruded section and fixed 150mm of size complete all as specified and directed by Engineer-in-Charge.. 43 Supply & fix stainless steel 100mm size of hasp and staple, safety type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed by Engineer-in-Charge. 44 Supply & fixin repairs vitreous china washbasin pedestal pattern of approved colour & quality including all necessories (excluding pillar tap) complete all as specified and directed by Engineer-in-Charge as in cupboard shutters 45 Supply & fixin repairs vitreous china wash down water closet pan (pedestal pattern) white including seat cover with hinhes device complete connected to p trap in built flushing cistern complete all as specified and directed by Engineer-in-Charge. 46 Supply & fix in repair 32mm waste fittings, brass, chromium plate for glazed ware sinks basins etc with long screwed shanks and fly nut flange end beddedd in red laid cement and other and fixed complete all as specified and directed by Engr-in-Charge. 47 Supply & fix in repair 15 mm dia fancy type swan neck pillar taps, cast copper alloy with capstan head, chromium plated screwed down high pressure, with or without lettered hot or cold with long screw shank and fly nuts screwed for iron pipe complete all as specified and directed by Engr-in-Charge 48 Supply & fix in repair 15 mm dia fancy type swan neck tap for sink, cast copper alloy with capstan head, chromium plated screwed down high pressure, with or without lettered hot or cold with long screw shank and fly nuts screwed for iron pipe complete all as specified and directed by Engr-in-Charge 49 Supply & fix in repair 15mm dia fancy type long shank bib taps for bathroom, cast copper alloy with capstan head, chromium plated screwed down high pressure with or without lettered hot or cold with long screw shank and fly nuts screwed for iron pipe complete all as specified and directed by Engineer-in-Charge. 50 Supply & fix in repair angle valve15mm bore brass chromium plated screwed down of any colour high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-Charge. 51 Supply & fix in repairs for shower rose for 15 mm dia, 125mm long, brass chromium plated screwed down of any colour high pressure with long shank screwed end for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-charge. 52 Supply & fix in repairs 15 mm health faucet 1 m long stainless steel body of any colour high pressure screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-charge. 53 Supply & fix in repairs stainless steel soap dish as approved qualitycomplete all as specified and directed by Engineer-in-charge. 54 Supply & fix in repairs PVC (SWR) 75mm dia cast iron floor trap with gratingincl jointing to waste pipe fixed in cement concrete type B1 (1:2:4 ) complete all as specified and directed by Engineer-in-Charge 55 Supply & fix in repairs 75 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge 56 Supply & fix in repairs PVC (SWR) bends 75 mm dia with access door any radius complete all as specified and directed by Engineer-in-Charge 57 Supply & fix in repairs for bevelled edge mirror of size 600mm x 450mm selected quality glass mounted on6mm thick AC bldg boards or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washer complete all as specified and directed by Engineer-in-Charge. 58 Supply & fix in repaires brass chromium plated tubular towel rail 20 mm dia D type 60 cm long between flanges complete all as specified and directed by Engr-in-Charge. 59 Supply & fix 12 mm toughened glass as in hinged doors/partitions and similar work incl cutting to shape, drilling holes incl floor spring / door closer and stainless steel handles 02 nos including necessary aluminium framework as required complete all as specified and directed by Engineer-in-Charge 60 Supply & fixin repair 8 mm thick toughened glass as in partitions/railings and similar work including cutting to shape drilling holes includingnecessary fixtures & fittings as required to fix with SS railing complete all as specified and directed by Engineer-in-Charge. 61 Supply & fix wall mounted cabinet of dimensions 51x38x99 cm consist of two shelves including fittings and fixtures i.e. magnetic snap closures, butt hinges, handle and hasp & staple with provn of fixing on wall with brackets and fasteners of material prelaminated 17 to 18 mm thick MDF board of dark shade complete all as specified and as directed byEngineer-in-Charge.Note:- (i) All built-in and/ or other fittings items for wall mounted cabinet, magnetic snap closures, butt hinges, handle and hasp & staple etc alike all as shown on drawing.(ii) Any minor requirement at site actually required at site will be provided at site by the contractor without any extra cost to Govt. The size,shape & spacing of wall mounted cabinet shall be all as per drg.(iii) Bidder shall refer the drawing on Page no 127 of tender document before quoting the rate of this item. 62 Supply & fix kitchen basket stainless steel set of03 nos made out of not less than 3 mm dia stainless steel rod of grade 304 alongwith telescopic channel (heavy duty) of size 300 mm x 440 mm long for each basket, roller of size 45 mm x 25 mm x 20 mm and magnetic connected plate to shutter incl 18 mm thick PVC chelukaply pre laminated on one side with decorative choice lamination and other side plainfor partition, door face, hinges and handles.Complete set shall be comprising of following baskets- (a) Cup & saucer bakset, (b) Cutlery basket, (c) Dish basket all as specified and as directed by Engineer-in-Charge 63 Supply & fix in repairs sink with drainage board made of stainless steel 1 mm thickfor kitchen with plugs, washers and including bedding in cementmortar to dwarf wall or including fixing cantilever brackets andconnectingunionto pipe over all size 915 x 460 mm, bowl size 410 x 330 x 180 mm mm Make : Nirali (Model : elegance small fromregular range, glossy) or size 915 mm x 460 mm bowl size 410 x 330 x 178 mm complete all as specified and directed by Engineer-in-Charge. 64 Material & labour for vacuum filed tinted double layered toughened glass (sound proof glalss) of 6 mm thick on inner side and clear flat glas on outside with 12 V (i.e. 12 mm thick of vacuum space) in between two glass alongwith necessary aluminium frame work or as top of table / counter with required access holes, rubber beading, cleats complete all as specified and directed by Engineer-in-Charge 65 Material & labour forpreparation ofplastered or unplastered old decorated external surfaces of walls by vaccum based sanding machine and applying one coat of exterior emulsion paint first qaulity in camouflage pattern as approved by the GE, complete all as specified and as directed byEngineer-in-Charge 66 Material & labour for point wiring for light point with 1.5 Sqmm single core multistranded copper conductor fire retardent FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through and including PVC concealed conduit dia not less than 20 mm with all accessories such as brass screws and cup washers including copper earth continuity wire of FRLS PVC insulated of size 1.5 Sqmm and making good to the disturbed surface of wall/ceiling etc complete all as specified and as directed byEngineer-in-Charge 67 All as per item No 66 here-in-before butfor One 3 pin 5 Amps socket out let on independent board complete all as specified and directed by Engineer-in-Charge. 68 All as per item No 66 here-in-before but with 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket out let on independent board complete all as specified and directed by Engineer-in-Charge. 69 Supply & fix modular switch one way, 6 Amp, 1 module ISI Mark complete all as specified and directed by Engineer-in-Charge. 70 Supply & fix modular switch one way , 16 Amp. ,1 module ISI Mark complete all as specified and directed by Engineer-in-Charge. 71 Supply & fix modular socket 6 Amp, 2/3 pin, combined 2 module, ISI marked complete all as specified and directed by Engineer-in-Charge. 72 Supply & fix modular socket 6/16 Amp, 2/3 pin, combined, 2 Module. ISI marked complete all as specified and directed by Engineer-in-Charge. 73 Supply & fix modular white cover plate with frame , 3 Module. ISI marked complete all as specified and directed by Engineer-in-Charge. 74 Supply & fix modular white cover plate with frame , 1 Module. ISI marked complete all as specified and directed by Engineer-in-Charge. 75 Supply & fix metal flush box, 3 Module. ISI marked complete all as specified and directed by Engineer-in-Charge. 76 Supply & fix metal flush box, 1 Module. ISI marked complete all as specified and directed by Engineer-in-Charge. 77 Supply & fixing LED lights fitting 1x 20W/18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-Charge. 78 Supply & fix ceiling rose, surface bakelite 65 x 50 mm two to three terminals complete all as specified and directed by Engineer-in-Charge. 79 Supply & fix MCB distribution board made of sheet metal enclosures double door type (CRCA sheet) dust and vermin proof , SPN 4 way with 200 Amps rated bus bar and copper connector and IP 43 protection, 220 volt , fixed on wall complete all as specified and directed by Engineer-in-Charge. 80 Material & labour for earthing complete with galvanised steel earth plate electrode 60cmx 60cm x 6.3 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal groundlevel connected to and including galvanised earth lead wire 4.0mm dia as earth lead up to 7.5 mtr long fixed by means of bolts, nuts, check nuts and washers etc. of galvanised iron or steelincluding provn of HDPE/GI protectionpipe light grade of 20mm bore and connected to earth strip earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicatedand testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore , wire mesh and lugs, test point etc. complete all as specified and directed by Engineer-in-Charge. Note: galvanised earth lead wire 4.0mm dia exceeding 7.5m long shall be measured & paid seperately. 81 Supply & fix electric driven chimney wall mounted type 90CM hood with stainless steel body with LED light lamp single phase 230 VAC having 1500 m3/Hr discharge capacity including baffle filter touch control alongwith aluminium duct chimney exhaust pipe 10 feet of suitable size complete all as specified and directed by Engineer-in-Charge. 82 Supply & install hi wall split airconditioner units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.3 or above of capacity 1.5 TR complete all as specified and directed by Engineer-in-Charge. 83 Supply & install hi wall split airconditioner units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.3 or above of capacity 2.0 TR complete all as specified and directed by Engineer-in-Charge. 84 Supply & fix PVC enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps C series complete all as specified and directed by Engineer-in-Charge. 85 Supply & fix distribution board (DB) , double door type made out of sheet metal enclosure (CRCAsheet ) dust and vermin proof DB , TPN 8 way with 200 Amps rated copper bus bar , 415 Volts with in built MCCB 100 Amps , 25 KA , 1 No. earth bar IP 43 protection complete all as specified and directed by Engineer-in-Charge. 86 Supply & fix double doorSheet metal enclosures factory madeDBs with protection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 Single pole and neutral 8 ways with 200 Amp rated bus bar 240 volts powder coated painted complete all as specified and directed by Engineer-in-Charge. 87 Supply & fix MCBs of the under mentioned type and rating and fixing in DBs (DBs measured and paid for separately) (Note :- Make of the isolator should be the same as that of DB) complete all as specified and directed by Engineer-in-Charge for the following :- 88 MCB TPN of 415 volts 40 Amps Capacity, C series 89 MCB SPN of 240 volts 5-40 Amps Capacity, C series 90 MCB SP of 240 volts 5-40 Amps Capacity, C series 91 Material & labour for sub main wiring with 2 runs of PVC insulated and unsheathed FRLSH cable 1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4.0 Sqmm single core size copper conductor drawn through and including PVCcasing caping with accessories and 4.0 Sqmm single core multistranded copper conductor PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI marked earth continuity wire complete all as specified and directed by Engineer-in-Charge..(Note : 2 runs of conductor with one run of earth wire and one run of casing caping will be measured and paid as one unit) 92 Material & labour for sub main wiring with 2 runs of PVC insulated and unsheathed FRLSH cable 1100 Volts grade, conforming to IS-1536-1977 multi-stranded 6.0 Sqmm single core size copper conductor drawn through and including PVCcasing caping with accessories and 6.0 Sqmm single core multistranded copper conductor PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI marked earth continuity wire complete all as specified and directed by Engineer-in-Charge.(Note : 2 runs of conductor with one run of earth wire and one run of casing caping will be measured and paid as one unit) 93 Material and labour for sub main wiring with 2 runs of PVC insulated and unsheathed FRLSH cable 1100 Volts grade, conforming to IS-1536-1977 multi-stranded 10 Sqmm single core size copper conductor drawn through and including PVCcasing caping with accessories and 10 Sqmm single core multistranded copper conductor PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI marked earth continuity wire complete all as specified and directed by Engineer-in-Charge.(Note : 2 runs of conductor with one run of earth wire and one run of casing caping will be measured and paid as one unit) 94 Supply, laying and testing of XLPE cable Insulated ,screened, PVC bedded,galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductorcomplete all as specified and directed by Engineer-in-Charge for the following :- 95 LT cables 300 Sqmm, 3.5 core. 96 LT cables 70 Sqmm, 3.5 core. 97 LT cables 6.0 Sqmm, 2.0 core. 98 Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in Soft/ loose soil complete all as specified and directed by Engineer-in-Charge. 99 Returning filling in soil and including spreading leveling watering and well ramming in layers n.exc. 25 cm thick complete all as specified and directed by Engineer-in-Charge. 100 Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points complete all as specified and directed by Engineer-in-Charge. 101 Material & labour for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engr-in-Charge. Note: Punned thickness of sand will be measured. 102 Supply & lay ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV, flat size 250mm X 150 mm X 40 mm in trenches as protection to LT UG cable all as specified and directed. 103 Supply & fix 50 mm bore Galvanised iron tubes light grade for cable protection complete all as specified and directed by Engineer-in-Charge. 104 Material & labour for Earthing complete with perforated galvanised steel pipe electrode, 50mm bore,medium grade, 6 metres length,buried directly and preferably vertically in ground with top edge not less than .6 metres below ground level connected with20mm dia galvanised steel pipe by means of reducer and clampedwith CI checknuts through 25x4mm GI earth lead passes from 40mm GI pipe,Filling of earth pit by alternate layer of charcoal or coke and salt all as shown in electricalearthing plate No. 2 connected to earthing test point all as specified or indicated including testing on completion along with necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel wire mesh and lugs, test point etc. complete all as specified and directed by Engineer-in-Charge. Note: GI strip exceeding 7.5m long shall be measured & paid separately. 105 Supply, testing and commissioning of LT electrical out door distribution panel board floor mounted cubical type dust proof, weather proof, vermin proof, astehically designed, having at least IP-54 degree of ingress protection, fabricated from 3.15 mm thick CRCA sheet with front and rear opening including bus bar chamber, 4 strips of Copper bus bar minimum 160 Amps capacity having size 25 mm x 10 mm cross sectional area, insulated color sleeves, procelain/epoxy insulators, rail channels cable alloy, danger notice board including provision of angle iron frame of size 40 x 40 x 6mm, 30 cm grouted in ground floor and 30 cm above GL duly painted including necessary excavation, foundation, PCC etc complete with locking arrangement duly powder coated of approved color connecting incoming & outgoing cable connection with suitable lugs, nuts, bolts, washers and cable joints, prewired complete with PVC insulated fire retardant copper conductor cable complete The panel shall be comprising of the following:-(a) Phase indicator lamps,modular,LED type (R-Y-B)-03 Nos (b) LED Multifunction MeterInput voltage measurement range 17-520 VAC (P-P)Aux supply 90-300 VACFlush mounting 96 x 96 mmSite selectable 1A /5ACT/PT site programmable V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhoursetc-01 No(c) MCCB 4 POLE 415 V 100 A (25 KA) ,4 pole with adjustable thermalsetting-01 No.(I/C)(d) MCCB 4 POLE 415 V 100 A (25 KA) ,4 pole with adjustable thermalsetting-01 No.(O/G)(e) MCB SPN 6 to 32 Amp, B Curve,10 KA-01 Nos (O/G) 106 Material & labour for transporting transformer 200 KVA to 315 KVA from one location to another location as directed within 4Km distance by disconnecting HT/LT cablesearthings etc as directed and reconnectuing HT/LT cables, erthings etc. complete all as specified and directed by Engineer-in-Charge. Note:-Necessary T& P required for transportation shall be included in item rate quoted 107 Material & labour for making plateform for DG Set using block masenery type 1:5:8 using 20mm graded aggregate with solid blocks & PCC (1:3:6) foundation concrete, 15mm thick plaster in 1:4 and 2 coats of cement base paint with allowable size for minimum hight from GL 1 feet and surface area not be less than 5.0mtr x 2.5 mtr complete to the entire satisfaction complete all as specified and directed by Engineer-in-Charge. 108 Supply, install, testing and commissioning of Diesel Engine driven generating set 250 KVA, 3 Phase, 4 wire, 415 Volts, 1500 RPM, 50 Hzpower supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integral acoustic enclosure having silent features such as modular bolted construction with fabrication on imported CNC torret punch machines, nine tank treatment process with pure polyster based powder coating to ensure long life in all weather conditions and for out door application/ installation, integrated design there by facilitating / easy handling installation & shifting of the equipment at site.Compliance standard of DG set should be confirming to IS-8728. The design of integral acoustic enclosure should be any type approved by national Physical laboratory as per Central Pollution Control Board (CPCB-IV) latest norms/ regulation with fuel tank, battery and standard accessories, acoustic enclosure, vibration pad, tools and spare,as provided by manufacturer, PCC foundation as per OEM to be paid under srl item No 101 above all as specified and as directed with the following specifications :-(A) ENGINE -Greaves make model D3V6TAG21 or equivelant model from make specified in Appx B, direct injection, V6 cylinders , water cooled, compression ignited, turbo charged and charged water cooled diseal engine 309 HP at 1500 RPM and compling with BS 5514/ISO 3046 standard :- (i) 24V electrical starting system consisting of starter motor, charging alternator and 1 x 12 V 188 AH battery. (ii)Dry type Air cleaner with restriction indicator (iii) In-line Fuel injection system with Electronic Governor (iv)Spin-on Lube oil filter elements (iv) Radiator, Air-to-Air after cooler, pusher fan & fan drive arrangement, Gear driven water pump (v) Sensor for oil pressure, Coolant temperature & level (iv)First fill of Lube oil. (API CF4 grade, Greaves Maxtherm Lube or equivalent) 109 (B) ALTERNATOR : Single bearing alternator suitable for continuous operation generating 250 KVAat 1500 RPM, 415 Volts, 0.8 power factor (lag) suitable for 50 Hz, 3 phase, 4 wire system confirming to BS 5000/ IS 4722, brushless type, screen protected revolving field, self excited, self regulated through an AVR.The alternator has the following features :(a) ± 1.0% voltageregulation (max) in static conditions (b) IP : 23 protection with insulated class H (c)Permissible overload of 10% for one hour in 12 hours of operation.Features, Functions, Protections(a) 16 character x 2 line alphanumeric LCD display with LED backlight (b)Operator interface (c) Provide a record of most recent fault conditions, Fault history stored in the control non volatile memory (d) Provide Alternator data frequency.Provide Engine data- Starting (a) Battery Voltage (b) Engine Temp (c) Oil pressured (d) Engine Hrs runControl includes provision for service adjustment and calibration of DG control function (a) Voltage, frequency selection (b) Meter calibration (c) Configurable input and output set up Power start operates on 24 V DC batteries Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode.Engine Starting- The control system supports automatic engine starting, Primary and back up start disconnects are achieved by battery charging feedback or main alternator output frequency.Controller provide configurable time delay of 0-300 sec to start after remote start signal and time delay of 0-600 secs prior to shutdown after stop signal.Sleep mode increase battery life. Configurablecurrent setting from low to minimize current draw when genset is not working.Engine Protective Functions includes :- Configurable alarm output emergency stop : Annunciated whenever an emergency stop signal is received by the control (a) Low Lube oil pressure warning and shutdown (b) High engine water temperature warning / shutdown (c) Low coolant temp warning (d) sensor failure indication (e) Low and high battery voltage warning (f) Weak battery warning (g) Fail to start shut down (h) Cranking lockout : Control will not allow the starter to engage or to crank the running engine (j) Cyclic cranking : Configurable for the number of starting cycle (1 to 7) and duration of crank and rest periods (k) Alternator Protective functions includes (l) High and Low AC voltage shutdown (m) Under and over frequency shutdown / warning (n) Loss of sensing voltage input shutdownFuel tank( In built fule tank) 110 Supply, install, testing and commissioning ofAMF Panel outdoor type suitable for 250 KVA DG set factory made out of CRCA Steel 3.15mm thick Sheet, floor mounted type and front operated type, totally enclosed dust, damp and vermin proof, all doors and joints will be suitable gasketed to form dust and vermin proof. The panel should bepowder coated with minimum thickness of 50 microns, after elaborate pre-treatment to form a long lasting characteristic. The control panel will be complete in all respect with fuses, wiring and labels etc, the following will be incorporated in the AMF Panel :-(i)Multifunctional meter digital (Amp+Volt+PF+Hz+KW+KWH)-01 No.(ii)Alternator voltage monitor 01 No(iii)Main voltage monitor - 01 No(iv)Ammeter DG digital - 01 No(v)Voltmeter DG digital - 01 No(vi)Main Power contactor -4 pole of capacity 400 Amps -01 No(vii)DG Power contactor -4 pole of capacity 400 Amps - 01 No(viii)Indicator Lamp - 02 Nos(ix)MCB (For control ckt)-10 Nos(x) Auxiliary Contactor -02 Nos (xi) Automatic battery charger 24 volt -01 No(xii)Terminal O/L relay - 01 No(xiii)Terminals (for control cable)-06 Nos(xiv)One set of copper bus bar of 600 Amps capacity.(xv)Main MCCB -4 pole of capacity 400 Amps -01 No(xvi)DG MCCB -4 pole of capacity 400 Amps - 01 No(xvii) control cable of suitable size -1 Job Note: The required PCC foundation for AMF Panel is included in the quoted rate. 111 Material & labour for transporting DG Set with AMF panel 82.5 KVA from one location to another location as directed within 4Km distance by disconnecting LT cablesearthings etc as directed and reconnectuing LT cables,AMF Panel, earthings etc. complete all as specified and directed by Engineer-in-Charge..Note:-All T& P required for transportation shall be included in item rate quoted.
|