PROVISION OF MINI ARMOURY, BOREWELL, TRAINING SHED, OBSTACLE TRAINING AND MISC INFRASTRUCTURE AND TOILETS FOR AGNIVEER (MALE & FEMALE) AT TILAKWADI ATS BELAGAVI.; 1 GENERAL SUMMARYNOTE: Schedule ‘A’ Part I to XIare prepriced by MES under Ser Nos. 2.00to 12.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. 2 Lumpsum price worked out by the contractor for “Building or works” as listed in Schedule ‘A’ Part - I inserted by MES . 3 Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’ Part - II inserted by MES . 4 Lumpsum price worked out by the contractor for “Internal Electric Supply” as listed in Schedule ‘A’ Part - III inserted by MES . 5 Lumpsum price worked out by the contractor for “PVC water tank with staging” as listed in Schedule ‘A’ Part - IVinserted by MES . 6 Lumpsum price worked out by the contractor for “Path” as listed in Schedule ‘A’ Part - V inserted by MES . 7 Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part - VI inserted by MES . 8 Lumpsum price worked out by the contractor for “Obstacles” as listed in Schedule ‘A’ Part -VII inserted by MES . 9 Lumpsum price worked out by the contractor for “Fencing and Gate” as listed in Schedule ‘A’ Part -VIII inserted by MES . 10 Lumpsum price worked out by the contractor for “External Water Supply” as listed in Schedule ‘A’ Part -IX inserted by MES . 11 Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part -X inserted by MES . 12 Lumpsum price worked out by the contractor for “Lightning Protection” as listed in Schedule ‘A’ Part -XI inserted by MES . 13 Schedule ‘A’ Parts XII and XIII are not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6. 14 Schedule "A" Part - XII : Design, Supply and erection of Pre-Engineered building steel structure for Training shed of size 21m x 10m and 3.2m height (inner dimension) with Trapezoidal profile pre-painted Galvalume sheet 0.50mm thick, RCC M-25 Design mix foundation, anchor bolt in the base and bed plates, PCC floor and underlayers, solid block masonry in side walls upto 1m height including dwarf wall and plinth beam, excavation in rocky areas (blasting prohibited), plastering in cement mortar, plinth protection, Epoxy coated paints to structural steel surface. etc complete all as specified and as shown on drawings.Note: (i) PCC floor and underlayers as specified in schedule of finishes are deemed to be included in the quoted Lumpsum. 15 Design, Supply and erection of Pre-Engineered building steel structure for Training shed with equipment store of size 21m x 10m (16m x 10m and 5m x 10m) of 3.2m height (inner dimension) with Trapezoidal profile pre-painted Galvalume sheet 0.50mm thick, RCC M-25 Design mix foundation, anchor bolt in the base and bed plates, PCC floor and underlayers, solid block masonry in side walls upto 1m height including dwarf wall and plinth beam, excavation in rocky areas (blasting prohibited), plastering in cement mortar, plinth protection, Epoxy coated paints to structural steel surface. etc complete all as specified and as shown on drawings.Note: (i) PCC floor and underlayers as specified in schedule of finishes are deemed to be included in the quoted Lumpsum. 16 Schedule "A" Part - XIII : Fittings, Fixtures & Misc items: INTERNAL WATER SUPPLYSupply and fix 15mm bore angle cock cast copper alloy fancy type chromium plated for PPR pipe complete all as specified and as directed. 17 Supply and fix 15 mm bore two waybib tap cast copper alloy chromium plated with crutch or butterfly handle, screwed down , screwed to PPR/ galvanised iron pipe providing aerated flow of water, complete all as specified and as directed. 18 Supply and fix 15 mm bore long nose bib tab cast copper alloy chromium plated with crutch or butterfly handle, screwed down , screwed for galvanised iron or any type of pipe, complete all as specified and as directed.Make: Cera Cat part No. F 2002152 or equialent make as specified in list of makes 19 Supply and fix 15 mm bore Pillar cock with swan neck spout (left/right) cast copper alloy chromium plated with crutch or butterfly handle, screwed down , screwed to PPR/ galvanised iron or any type of pipe, complete all as specified and as directed.Make: Cera Cat part No. F 2002104,5 or equialent make as specified in list of makes 20 INTERNAL ELECTRIC SUPPLYMaterial and labour for earthing complete with galvanised steel pipe electrode of size 40 mm bore, medium grade, 2.5 meter length, buried directly in ground in bore 350 mm dia vertically to a depth not less 3.2 meter below ground level with top edge of the pipe not less than 60 cm below normal ground level connected to galvanised earth lead wire 4.0mm dia by meanswith bolts, nuts check nuts and washers protected by Gl light grade pipe of size 15 mm dia and connecting up with the DB as the case may be upto a maximum distance of 7.5m away from the earth electrode including test point junction, excavation, earthwork, PCC Chamber, RCC Cover(Yellow painted) with handle , watering pipe 20mm dia GI Medium grade with funnel and wire mesh, Charcoal dust , salt, Mild steel Earth markerwith earthing result, dateall as per plate no.2 of SSR 1991 and etc. complete in all respects all as specified and directed by engineer in charge. Note:- Boring charges are included in the above quoted rates. 21 EXTERNAL WATER SUPPLYDrilling trial bore of 150 mm dia upto 90 meter depth below ground level in any kind of soil strata including hard stone/boulder complete all as specified and as directed. 22 Drilling trial bore of 150 mm dia exceeding 90 meter depth below ground level and upto 120 RM in any kind of soil strata including hard stone/boulder etc complete all as specified and as directed. 23 Drilling trial bore of 150 mm dia exceeding 120 meter depth below ground level and upto 150 RM in any kind of soil strata including hard stone/boulder etc complete all as specified and as directed. 24 Development of bore well with compressed air and after with 25% extra capacity pump by pumping muddy water complete all as specified and as directed. 25 Yield test for the bore well by continuously pumping for 16 hours to determine safe pumping yield complete all as specified and as directed. 26 Supply and fix MS well cap of suitable size, with nut, bolts & MS clamps complete all as specified and as directed. 27 Supply,install, commissioning and testing Submersible Pump Set 5 HP (3.75KW) capacity,3 phase, 415 Volts 50 Hz, Head 100Mtrs, Discharge 100 LPM,2900 RPM complete all as specified and as directed. 28 Supply,install, commissioning and testingMonoblock Pump Set5HP 415 Volt3 Phase , 50 Hz Discharge 600 LPM,3000 RPM and Delivery Size 80mmx8mmsize including provision of PCC 1:3:6using 40mm graded aggregate for baseand suitableBed bolt nut and washers andprovn of necessary electric supply from panel board toPumpsetcomplete all as specified and as directed. 29 Supply laying and testing submersible cable, flat, PVC insulated (heavy duty) with copper conductor,1100 volts grade of size 3 core 4 sqmm complete all as specified and as directed. 30 Supply and fix Valve reflux with bypass Arrangements 50mm (2") dia complete all as specified and as directed. 31 Supply and fix Valve reflux with bypass Arrangements 80mm (3") dia complete all as specified and as directed. 32 Supply and fix foot valve 80mm (3") dia confirming IS-4038(for suction line -02 Nos) complete all as specified and as directed. 33 Material and labour for construction of valve pit chamber of size 1000mm x 1000 mm x 1000 mm (internal size) with 3.15 mm thick MS sheet cover and angle iron 40mmx40mmx6 mm thick fame embedded in 15 cm thick PCC coping with locking arrangement with two coats of synthetic enamel with internal external surfaces over a coat of red oxide primer including necessary excavation, removal of surplus soil to a distance not exceeding 50 mtr, returning filling in PCC 1:3:6 type C2 75 mm thick as in foundation/floor brick work (one brick thick) in cement mortars (1:4) PCC 1:2:4 type C1 in copping, Plastering in CM 1:4 and 75 mm thick hard core below foundation etc complete all as specified and as directed. 34 EXTERNAL ELECTRIFICATIONSupply, Installation and Testing of 12.5M High mast shaft in two sections suitable for 47 m/sec windspeed asperIS875part 3, withhead frame,winch mounting bracket, luminaries carriage suitable to install 06 nos luminariesin symmetrical arrangement. The RaisingandLowering system shall be of 2 Continues Rope system without any intermediate compensating disc with double drum winch.The wire rope shall be of minimum6mm Stainless Steel of grade AISI 316, 3 mm section thickness, top dia 150 mm, bottom dia 340/360 mm, with Stainless steel (AISI 316) 2/3 wire rope system, PCD - Pitch Circle Dia - 445 mm, Integral power tool motor,manual handle, Junction box including Construction of shallow foundation with M25gradeconcrete for the high mast and foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template complete all as specified and as directed. 35 Supply and fix 150W LEDFloodlightfittingcompletewith driver and necessaryaccessories asrequiredtomountontheLanterncarriage. HousingmaterialofthefloodlightshouldbeofMattGreypolyster powder coated pressure Die-cast aluminium housing, with heat resistant toughened clear glass fitted with SS screws. The system lumen output should notbe lessthan 120 lumens /watt.Fixtureshouldbesuitableforainputvoltagerangeof120V to270V with input power supply of230 V AC. Ingress protection class ofIP 66 complete all as specified and as directed.Make: BAJAJ CAT Ref: PRAZE F 180L WH NB-A5 TG SD or its equivalent in approved make. 36 Supply, Install and Testingofoutdoor(3.15 mm Thick) standmountedfeederpillarwith16ATPNMCB incomer,singledialtimeswitch,16A TPcontactorfortheautomatic switching of luminaries, power tool control with 2 no 6A contactors and raise lower push button, Incoming 10 sqmm and out going 2.5 sqmm terminals complete all as specified and as directed. 37 Supply and fix DWC pipe IS-16205 Size inner dia 50mm outer dia 63mm for cable protection in wall underground laying of underground cable s including SNAP-FIT Coupler and all fittingsas required at site complete all as specified and as directed. 38 Supply and fix DWC pipe IS-16205 Size inner dia 32mm outer dia 40mm for cable protection in wall underground laying of underground cables including SNAP-FIT Coupler and all fittingsas required at site complete all as specified and as directed. 39 Material and labour for earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6.0 mm buried directly in ground (earth pit not less than 2.25 Mtr below normal ground level ) connected to galvanized earth lead strip of size 25x4 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel including 40 mm dia light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm dia, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type C1, 50 mm thick precast RCC (1:2:4) type B1 pit cover reinforced with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including galvanised strip of size 25mm x 4 mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of soils to a distance not exceeding 50 mtr and necessary connection and testing and all as shown in electrical plate No. 3 of SSR Pt-I, 2009 complete all as specified and as directed. 40 Supply, install, testing and commissioning of LT Feeder pillar Box CPRIapproved AC415 Volt, 50 Hz3 Phase 4 wireof suitablesize for accommodatingthe following accessories totally enclosed self supportingstructure/cubicle fully compartmentalized typeweather proof, protection IP-54 suitable for outdoor use with bottom cable entry with suitablecable glandsstructuremade out of 3.15 thickCRCA Steel sheetwith angle ironframe work and legs of ISA, 40x40x6mmwith four legsgrouted to PCC(1:2:4) type B1 foundationblock with suitable mountingarrangement for bus bars voltmeter, ammeterand MCCBs withsloppingcanopy at top double hinged doors at front with suitable locking arrangement, Provision of lowers at sidesstructure treatedunder 8 tankmetal treatmentprocess and duly powder coated complete all as specified and as directed.(for Main Incoming Panel). 41 (A)INCOMING:-(a) MCCB 4 Pole 415 Volts, 63 Amps, 16 KA with adjustable microprocessorbased settings -01 No(B) OUTGOING:-(a) MCB TPN 32 Amps capacity, 230 Volt10 KA Breaking capacity -02 Nos (for High Mast + Spare)(b) MCCB 4 pole 415 V of breaking capacity 10KA of 32-40Amps with fixed thermal and fixed magnetic setting - 04 Nos(c) Digital voltmeter (0-500 Volts), Ammeterwith CTSand selector switch (0-63A) and frequency -01 Nos(d) RYB LED indicating lamp panel mounting type (Set of three) -01 Nos(e) Aluminium bus bar capacity of 200 Amps 42 Supply, install, testing and commissioning of LT Feeder pillar Box CPRIapproved AC415 Volt, 50 Hz3 Phase 4 wireof suitablesize for accommodatingthe following accessories totally enclosed self supportingstructure/cubicle fully compartmentalized typeweather proof, protection IP-54 suitable for outdoor use with bottom cable entry with suitablecable glandsstructuremade out of 3.15 thickCRCA Steel sheetwith angle ironframe work and legs of ISA, 40x40x6mmwith four legsgrouted to PCC(1:2:4) type B1 foundationblock with suitable mountingarrangement for bus bars voltmeter, ammeterand MCCBs withsloppingcanopy at top double hinged doors at front with suitable locking arrangement, Provision of lowers at sidesstructure treatedunder 8 tankmetal treatmentprocess and duly powder coated complete all as specified and as directed.(for Trg Sheds). 43 (A)INCOMING:-(a) MCCB 4 Pole 415 Volts, 32-40Amps, 10 KA ratingopen execution, thermal magnetic fixed type-01 Nos.(B) OUTGOING:-(a) MCB TPN 32 Amps capacity, 230 Volt10 KA Breaking capacity -01 Nos (b) MCB SPN 6-32 Amps capacity, 230 Volt10 KA Breaking capacity -04 Nos(for trg sheds)(c) Digital voltmeter (0-500 Volts), Ammeterwith CTSand selector switch (0-63A) and frequency -01 Nos(d) RYB LED indicating lamp panel mounting type (Set of three) -01 Nos(e) Aluminium bus bar capacity of 200 Amps. 44 Supply, install, testing and commissioning of LT Feeder pillar Box CPRIapproved AC415 Volt, 50 Hz3 Phase 4 wireof suitablesize for accommodatingthe following accessories totally enclosed self supportingstructure/cubicle fully compartmentalized typeweather proof, protection IP-54 suitable for outdoor use with bottom cable entry with suitablecable glandsstructuremade out of 3.15 thickCRCA Steel sheetwith angle ironframe work and legs of ISA, 40x40x6mmwith four legsgrouted to PCC(1:2:4) type B1 foundationblock with suitable mountingarrangement for bus bars voltmeter, ammeterand MCCBs withsloppingcanopy at top double hinged doors at front with suitable locking arrangement, Provision of lowers at sidesstructure treatedunder 8 tankmetal treatmentprocess and duly powder coated complete all as specified and as directed.(for Toilet and Armory). 45 (A)INCOMING:-(a) MCCB 4 Pole 415 Volts, 32-40Amps, 10 KA ratingopen execution, thermal magnetic fixed type-01 No(B) OUTGOING:-(a) MCB TPN 32 amps capacity - 415 volts 10KA breaking capacity - 02 Nos(b) MCB SPN 6-32 Amps capacity, 230 Volt10 KA Breaking capacity -06 Nos (c) Digital voltmeter (0-500 Volts), Ammeterwith CTSand selector switch (0-63A) and frequency -01 Nos(d) RYB LED indicating lamp panel mounting type (Set of three) -01 Nos(e) Aluminium bus bar capacity of 200 Amps. 46 Supply , install, testing and commissioning of LT Feeder pillar Box CPRIapproved AC415 Volt, 50 Hz3 Phase 4 wire of suitablesize for accommodatingthe following accessories totally enclosed self supportingstructure/cubicle fully compartmentalized typeweather proof, protection IP-54 suitable for outdoor use with bottom cable entry with suitable cable glands structuremade out of 3.15 thick CRCA Steel sheet with angle ironframe work and legs of ISA, 40x40x6mm with four legsgrouted to PCC(1:2:4) type B1 foundation block with suitable mountingarrangement for bus bars voltmeter, ammeterand MCCBs withsloppingcanopy at top double hinged doors at front with suitable locking arrangement, Provision of lowers at sidesstructure treatedunder 8 tankmetal treatmentprocess and duly powder coated complete all as specified and as directed.(for Bore well). 47 (A)INCOMING:-(a) MCCB 4 Pole 415 Volts, 32-40Amps, 10 KAratingopen execution thermal magnetic fixed type -01 Nos,(B) OUTGOING:-(a) MCB TPN 4 Pole 32 Amps, 10 KA415 Volts-02 Nos(b) DOL Starterfor SubmersiblePump set5HP 3.75 KW 415 Volt, Relay range 7A to 12amps -01 Nos (c) Digital voltmeter (0-500 Volts), Ammeterwith CTSand selector switch (0-63A) and frequency -02 Nos(d) RYB LED indicating lamp panel mounting type (Set of three) -02 Nos(e) Aluminium bus bar capacity of 200 Amps. 48 Supply, install, testing and commissioning of LT Feeder pillar Box CPRIapproved AC415 Volt, 50 Hz3 Phase 4 wireof suitablesize for accommodatingthe following accessories totally enclosed self supportingstructure/cubicle fully compartmentalized typeweather proof, protection IP-54 suitable for outdoor use with bottom cable entry with suitablecable glandsstructuremade out of 3.15mm thickCRCA Steel sheetwith angle ironframe work and legs of ISA, 40x40x6mmwith four legsgrouted to PCC(1:2:4) type B1 foundationblock with suitable mountingarrangement for bus bars voltmeter, ammeterand MCCBs withsloppingcanopy at top double hinged doors at front with suitable locking arrangement, Provision of lowers at sidesstructure treatedunder 8 tankmetal treatmentprocess and duly powder coated complete all as specified and as directed.( For Pump House). 49 (A)INCOMING:-(a) MCCB 4 Pole 415 Volts, 32-40 Amps, 10 KA rating open execution thermal magnetic fixed type -01 No(B) OUTGOING:-(a) MCB TPN 4 Pole 32 Amps capacity, 415 Volt10 KA Breaking capacity -02 Nos (b) MCB SPN 6-32 Amps capacity, 230 V of breaking capacity 10KA - 02 Nos(c) Digital voltmeter (0-500 Volts), Ammeterwith CTSand selector switch (0-63A) and frequency -01 Nos(d) RYB LED indicating lamp panel mounting type (Set of three) -01 Nos(e) DOL Starter for Submersible Pump set 5HP 3.75 KW, 415 Volt, Relay range 7A-12A - 01 No(f) Aluminium bus bar capacity of 200 Amps. 50 LIGHTNING PROTECTIONSupply and fix lightning protection air termination made of 32 mmdia light grade GI pipe 1.2m longwelded to a suitableMS Plate basebent to shape and fixed on porcelain insulatorbase including fixingof 300mm long 12mm dia Aluminium rod with necessaryclamps complete all as specified and as directed. 51 Material and labour for earthing with copperplate electrode of size 300 mm x 300 mm x 3.0 mm buried directly in ground (earth pit not less than 2.25 Mtr below normal ground level ) connected to galvanized earth lead strip of size 25x3 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel including 40 mm dia light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm dia, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type C1, 50 mm thick precast RCC (1:2:4) type B1 pit cover reinforced with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including galvanised strip of size 25x3mmfor extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of soils to a distance not exec 50 mtr and necessary connection and testing complete all as shown in electrical plate No. 3 of SSR Pt-I, 2009, all as specified and as directed.
|