Bids Are Invited For Price Registration For The Acquisition Of Essential Medical-Hospital Equipment For Aid/ ... in Brazil
Tender Notice
TenderID
89910401
Tender Brief
Bids Are Invited For Price Registration For The Acquisition Of Essential Medical-Hospital Equipment For Aid/Diagnosis, Treatment, Prevention And Rehabilitation Of Health To Meet The Needs Of The Municipal Health Department, Of The Municipality Of Curvelo, State Of Minas Gerais.
Stainless Steel Iv Support Fixed Column Made From 7/8 Round Stainless Steel Tube; Telescopic Column Made From 5/8 Round Stainless Steel Tube; “U” Shaped Base Made From Round Stainless Steel Tube; With 04 Swivel Castors; Height Adjustment System Through Chuck; With 04 Hooks Made From Stainless Steel. Dimensions Approx. Maximum Height 2.30M X Minimum Height 1.20M X Width 40Cm X Depth 40Cm; Weight Approx. 08 Kg. Minimum Guarantee Of 03 Months, From Receipt, Registration With Anvisa. Quality Standard: Argos Prudentina, Salutem Móveis, Mvm, Ng2mediacal Or Ht Or Equivalent Or Better Quality., Pulmonarpressometric And Volumetric Ventilator, Microprocessed, Cycled In Time, Volume And Flow, With 6-Inch Color Lcd Ventilation Graphic Monitor; Touch Screen, Which Can Ventilate Neonatal, Pediatric And Adult Patients Weighing From 1 Kg, Adjusted By The Operator. The Fan Must Have A Compliance Compensation System; Leak Compensation In All Conventional Ventilation Modes, Including Vni (Non-Invasive Ventilation); It Must Have A Self-Test System To Detect Leaks In The Respiratory Circuit; Have Flow And Pressure Trigger Sensitivity Options, Have Automatic Expiratory Cycling Adjustment, In Spontaneous Mode; Have Inspiratory Ramp Adjustment, In Pressure, Manual Or Automatic Mode; Have Two Flow Patterns: Square And R Timed 100% Oxygen Release, With Automatic Return To Original Concentration; Have An Electronic And Internal O2 Blender With Automatic Calibration Of The Oxygen Sensor, Given That All Sensors (Flow And O2) Must Be Distal, The Flow Sensor Must Be Activated By A Heated And/Or Ultrasonic Filament; Have An Active Exhalation Valve Concept; It Must Have The Future Possibility Of Coupling A Heated Reusable Expiratory Filter With A Drain. It Must Operate With A Pneumatic Supply Of Compressed Air And Oxygen And Be Capable Of Operating With Only One Gas (It Must Not Have A Turbine, Piston Or Similar). Internal Battery That Guarantees The Operation Of The Fan For At Least 60 Minutes. The Fan Must Be Capable Of Storing At Least 24 Hours Of Trends; Automatically Display The Last Adjusted Parameters When The Device Is Turned Off And Turned On Again. It Has The Function Of Suspending Ventilation After Disconnection And Resuming Ventilation Automatically After Reconnection, Directly Or By Selecting The Suction Function. Other Specifications Included In The Notice., Wheelchair For The Obese: Built In Resistant Tubular Carbon Steel, With Epoxy Painting; Double X Foldable Structure, With Tubular Stainless Steel Reinforcement; Upholstery In High-Resistance Foam, Covered In Nylon; Reinforced Seat With Special Tensioning Straps; Security Lock; Foam Cushion With Density: Between 28 D To 45 D, With A Minimum Thickness Of 5 Cm; Covered In Waterproof Fabric; 24” Aluminum Rear Wheels With Anti-Puncture Tires Solid 8” Inch Front Wheels; Adjustable Bilateral Brakes; Clothing Protector; Adjustable Footrest, Laterally Foldable, Removable, With Height Adjustment; Retractable Armrests; Calf Support (Band); Comes With Pelvic Belt; Seat Width: Between 60 And 66 Cm; Total Open Width: Approx. 80 To 84 Cm; Seat Depth 46 To 47 Cm; Backrest Height: Approx. From 45 To 50 Cm; Supports 160 To 250 Kg; Chair Weight: Approx. 28.5 Kg.
Contact Information
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 89910401
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.