Tender For Provision Of 01 X Transformer 63 Kva Along with Fitment For Guard Post Under Ge Nagrota.; 1 Supply, installation, Testing, Commissioning of Oil Cooled, Copper wound, Step down "BIS marked & BEE star labelled " transformer of capacity 63 KVA plinth mounted outdoor type with latest feature complete with standard fitted HT 11 KV 3 phase, LT 433 V 3, phase 4 wire,50 C/S oil immerse, naturally cooled externally cooling tube delta connection on primary HT 11 KV side and star connection on secondary LT 433V with tapping at +/-2.5 %to +/-5 % & +/- 7.5 % on HV side and to be changed by means of hand operated off load tap changing gear including first filling of new transformer oil of dilectric strength not less than 64 KV with all fitting and accessories such as LT box with cable gland, HT box with cable gland, Silica gel, breather, Oil level indicator gauge, drain out valve (oil tank),exhaust vent, air release valve, temp gauge, cast iron wheel etc comply with EEL 2 IS 1180 2014 with amendment 1,2,3 & 4 having total losses @ 50% load 300W & total loses @ 100% load 1050W. Following items/ Accessories included in this rate therefore No any extra cost will be paid for this items completeall as specified and directed by Engineer-in-charge.(i) Name, rating & diagram plate(ii) 7 Positins Off circuit tap changing switch (iii) Earthing terminals(iv) Lifting lugs(v Oil drain valve with plug(vi) Oil filter valve with plug(vii) Conservator with oil filling hole(viii) Thermometer pocket(ix) Air release plug(x) Silicagel breather(xi) Removable inspection opening(xii) Explosion vent(xiii) Transformer platform as per manufacturer design with Chain Link fencing and also danger notice plate of size as directed on 4 sides of chain link fencing. Note :- Chain link fencing shall be 4mm dia wire having mesh size of 100m X 100mm including, rails, straining bolts etc including provision of binding wire and having flat iron of size 40mm X 6mm fixed on angles of size 65mm X 65mm X 6mm (for securing wire mesh) including all necessary drilling, bolting or riveting and mild steel in flat, round or square bars, in available length. 2 Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground preferably in vertical position (Earth pit not less than 2.25 mtr below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 25×4 mmby means of bolts, nuts, check nuts and washers of galvanised iron including pit of PCC (1:2:4) type B-1, pre cast RCC cover slab of size 550x550x75mm, XPM reinforced not less than 1.60Kg/Sqm with suitable built in handle made from 12mmdia MS round bar, excavation and earth work in any type of soil, 20mm dia bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end, 15mm bore light grade galvanised iron protection pipe for earth lead wire upto 5m length, charcol, common salt complete all as shown in electric plate No 3 of SSR 2009 Part I connected to equipmentand testing on completion complete all as specified and directed. 3 Supply, Fixing , Commissioning and testing of CPRI approved outdoor cubical type LT Feeder Piller box suitable for 415 V, 3 Phase , 4 wire50 Hz , AC Supply system fabricated from stainless steel totally encloused ,dust, weather & vermin proof , 3.00 mm thick for outer shell and 2 mm thick for inner shell having MS section not less than 50x50x6 mm thick havingTPN aluminium busbar of capacity 150 Amps mounted on porcelain insulatorduly drilled hole for cable connection including front and rear side opening with locking arrangement, with MCCB FP 125 Amp, 16 KA, 415 Volts 50 Hz with adjustable thermal and adjustable magnetic setting and provn for incoming and outgoing cables withglands includingcontrol wiring with minimum 2.5 sqmm PVC insulated copper conductor for measuring of voltage, amp with indicators RYB, along with multifunctional meter showing V,I ,PF , Hzand painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 60 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate. 4 Supply and laying XLPE cable insulated,armoured, heavy duty electric cable with aluminium conductor,11000 volts grade, cross-sectional area 95 Sqmm 3 core complete all as specified and directed . 5 Supply and fixCable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing materialand accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 Sqmm. 6 Supply,laying, jointing and testingXLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area50 Sqmm 3.5 core, complete all as specified and directed by Engineer-in-Charge 7 Supply,laying, jointing and testingXLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area35 Sqmm 3.5 core, complete all as specified and directed by Engineer-in-Charge 8 Supply and laying or fixing or passing through pipe, 1100 Volt grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape unarmoured with galvanised steel wire or tape and overall PVC sheathed 16 Sqmm 2 Core nominal cross sectionclamped along with wall complete all as specified and directed. 9 S&F fabrication and installation ofterminal box outdoor canopy type, size 40cm (Height) x 30 cm (width) x 12 cm (thick), size of canopy 30cm x 13 cm complete with locking arrangement 02 Nos aluminium busbar size 20 x 5mm, 4 Nos nut bolt, & 4 Nos aluminium cable socket suitable forupto 16 sqmm cable embeded in PCC foundation with 2 Nos angle iron leg 25mm x25mm 400 mm longas per samplecomplete all as specified and as directed.
|