Repair And Maintenance Services Of Machinery – Data Center Operation Support 2024. Operation Support Includes (But Is Not Limited To) Planned Preventive Maintenance, Service, Error Correction And Expert Consultation For Building Mechanical Equipment, Ups Equipment, Diesel Generators, Building Monitoring System, Medium Voltage System, Low Voltage System, With Regard To The Industrial Cleaning Of The Extinguishing System And Technological Areas, 470 Pieces Of Maintenance, As Specified In Detail In The Public Procurement Document. The Contracting Authority May Deviate From The Specified Quantity By + 21% During The Performance Of The Contract. (Fixed Frame: 470 Pcs, Option Frame: 101 Pcs). The Tenderer Undertakes To Draw 470 Units During The Term Of The Contract. Operation Support Tasks Include The Following Areas And Elements: 1. Mechanical Engineering: A. Cooling Power (Pid Controlled): 14X445kw+1X171.7Kw+ 2X9.17Kw+3X406kw=7638.04Kw B. Cooling Gas Quantity 14X112kg+2X6.5+1X27kg+3X88kg=1845Kg C. Air Handlers 1X520m3/H+2X4160m3/H+1X4160m3/H=12480M3/H D. Main Circuit Pumps 8X30kw+2X11kw=264Kw 2. Ups A. Ups Powers: 4X2x4x250kva+2X400kva+4X250kva+ 1X100kva+1X30kva+ 1X10kva=9940Kva B. Number Of Batteries: 4X704+352=3168 Pcs, 88Ah 12V, 10 Years Old 3. Diesel A. 4 Units 2200Kw+ 1 Unit 1250Kw=10050Kw 4. Building Supervision A. Honeywell Ebi 410 B. 18,000 Data Points 5. Medium Voltage A. 10 Efasec Normafix Cells, 10 Abb Unisec Fields B. Transformers 5X2000kw+ 1X1600kw=11600Kw 6.Low Voltage A. 136 Distribution Panels 7. Extinguishing System: Net 1,200 M2 Machine Room Area (White Space) Autonomous Gas Extinguishing System With Aspiration Sensor 8. Cleaning A. 2,000 M2 Technological Space (Including Parts Under The False Floor And Close To Voltage) Detailed Description Of The Specializations And Parts: 1. Mechanical Engineering: A. Cooling Power (Pid Controlled): 14X445kw+1X171.7Kw+ 2X9.17Kw+3X406kw=7638.04Kw B. Cooling Gas Quantity 14X112kg+2X6.5+1X27kg+3X88kg=1845Kg C. Air Handlers 1X520m3/H+2X4160m3/H+1X4160m3/H=12480M3/H D. Main Circuit Pumps 8X30kw+2X11kw=264Kw 2. Ups A. Ups Powers: 4X2x4x250kva+2X400kva+4X250kva+ 1X100kva+1X30kva+ 1X10kva=9940Kva B. Number Of Batteries: 4X704+352=3168 Pcs, 88Ah 12V, 10 Years Old 3. Diesel A. 4 Units 2200Kw+ 1 Unit 1250Kw=10050Kw 4. Building Supervision A. Honeywell Ebi 410 B. 18,000 Data Points 5. Medium Voltage A. 10 Efasec Normafix Cells, 10 Abb Unisec Fields B. Transformers 5X2000kw+ 1X1600kw=11600Kw 6.Low Voltage A. 136 Distribution Panels 7. Extinguishing System: Net 1,200 M2 Machine Room Area (White Space) Autonomous Gas Extinguishing System With Aspiration Sensor 8. Cleaning A. 2,000 M2 Technological Space (Including Parts Under The False Floor And Close To Voltage) Detailed Description Of The Areas Of Expertise And Components: Mechanical Engineering • Air Conditioning Systems And Other Mechanical Systems: O 187 Rittal Lcp Sk3311.011 Line Coolers With Cmc Tc Control O 20 Rittal Lcp Sk3311.540 /545 Line Cooler With Cmc Iii Control O 14 Pcs Rittal Sk3232.889 It Chiller (Ch 1-14) O Ch1-7 Group Controller Plc O Ch8-14 Group Controller
Contact Information
Contact No.
+36 13922222
Email
kiss.katalin@wigner.hun-ren.hu
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 89807907
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.