Tender For Construction Of Labs Under Pm Shri At Kendriya Vidyalaya No 2 Chandimandir Cantt; 1 Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil, complete all as specified and directed. 2 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc, laying of pipes, cables, poles, stayor for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in hard /dense soil, completeall as specified & directed. 3 Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed. 4 Reinforced cement concrete(M-25, design mix) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed (reinforcement shall be measured and paid for separately). 5 Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter to give rough finish to flat surfaces complete 6 Material and labour for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bendingspirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified. 7 Material and Labourmild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bendingspirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified & directed.(Stirrups) 8 Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm depth in soils, complete all as specified and directed. 9 Removal excavated soil to a distance not exceeding 50 m and depositingwhere directed at a level not exceeding 1.5 mabove the starting point complete all as specified & directed. 10 Reinforced cement concrete (M-25 design mix, using crushed stone aggregate) as in coloumns, pillars etc complete all as specified and directed (reinforcement shall be measured and paid for separately). 11 Formwork to sides of pillars, posts, struts, piers, columns and stanchionsrough finished surface of flat concrete complete all as specified and directed. 12 Reinforced cement concrete (M-25 design mix, using 20mm graded crushed stone aggregate) as in chajja and the like, complete all as specified and directed (reinforcement shall be measured and paid for separately). 13 Reinforced cement concrete (M-25 design mix, using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams, balconies, roofs, canopies shelves and the likecomplete all as specified and directed (reinforcement shall be measured and paid for separately). 14 Form work to soffits of suspended slabs such as roof slabs rough finished surface of concrete flat not exc 200mm thick complete all as specified and directed. 15 Reinforced cement concrete (M-25 , using 20mm graded crushed stone aggregate) as in beams, lintels over 1.5 metre span and the like complete all as specified and directed (reinforcement shall be measured and paid for separately). 16 Form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for roughly finished flat surfaces of concrete, all as specified. 17 18 to 20mm thick, granite (table rubbed and polished) inflooring , steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade, over and including 15mm thick screed in cement mortar 1:6 complete all as specified and directed. 18 Brick work with fly ash brick old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:4 complete all as specified & directed. 19 Brick work with fly ash brick old size bricks, straight or curved on plan exc 6 metre mean radiusin half brick thick walls built in cement mortar 1:4 complete all as specified & directed. 20 Hard core ofbroken stone or boulders of gauge n.exc. 63mm, deposited, spread and leveled in layers n.exc. 15cm thick, watered and rammed to a true surface complete all as specified & directed. 21 Supply and fixing moorum /red bajri filling as in sub base for floors or pavings, laid in layers n.exc. 15cm thick, spreading, leveling and ramming including watering complete all as specified and directed. 22 100mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base etc, finished even and rough complete all as specified and directed. 23 Kota Stone Slab flooring, 20-25mm thick, best quality over and including cement screed bed 15mm thick in cement mortar 1:6, laid and jointed with grey cement slurry and pointed with grey cement mixed with pigment to match the shade of the slab including cutting, rubbing, grinding and polishing (Mirror finish) complete all as specified and directed. 24 All as per serial item No 23 hereinbefore but on skirting / vertical surfaces laid over and including 10mm screed layer in cement mortar 1:3, cutting, rubbing, grinding and polishing complete, all as specified. 25 10mm thick rendering in Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed 26 Two coats of 100% premium acrylic plastic emulsion paint over a coat ofpriming paint including preparation of new wall surfacescomplete all as specified and directed. 27 Preparation of new surfacs and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed. 28 Rendering 15mm thickon fair faces of brick worksurfaces, finished even and fairin cement mortar (1:4), inclunding using water proofing compound, complete all as specified.Note : WPC shall be measured and paid separately. 29 Supply only integral water proofing compound (ISI Marked) complete all as specified & directed. 30 5mm thick rendering in Cement and Sand mortar 1:3 concrete surfaces as in ceiling / chajjas facia at any position finished even and smooth without using extra cement complete all as specified and directedng 31 2mm thick birla white putty wall care putty on walls complete all as specified and directed. 32 PCC 1:2:4 type B-0 for embedding of angle iron post of size 0.23 x 0.30 x 0.450mm complete all as specified and directed. 33 Plain cement mortar 1:3:6 (type C-1 using 20mm graded aggregate), 75mm thick as in Plinth protection , finishing cement concrete even and smooth without using extra cement,all as specified. 34 Powder coated aluminium sections as inframes/ shutter of doors/window/ventilators /partitions,(Sliding / openable/ three track)including joinging cleats, glazing clips, rubber neoprene beading, powder coated aluminim snap beading, screws etc. fixed as in repair complete all as specified and directedNote : (i) Minimum thickness of power coating shall not be less than 50 micron.(ii) Weight of aluminum section only shall be measuerd and paid.(iii) Aluminum doors/windows /ventilators to be fixed to jambs with chromium plated screws .(iv) The rate shall be inclusive of neoprene beadings, snap beading, screws etc and in case of sliding shutters locking arrangement and rollers in sliding shutters. Weight of fitting fixtures will not be measured for arriving the weight of aluminum section.(v) Glass /wooden panel/ACP sheet shall be measured and paid separately under respective items.(vi) Design as directed by Engineer in charge. 35 Supply only5.5mm thick sheet glass, ordinary quality and glazing in squaresexceeding 0.5 Sqm in each pane fixed to aluminum frame work complete all as specified & directed by Engineer-in-charge. 36 Stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.00mm including fixed with stainless steel wire staplescomplete all as specified & directed. 37 Glazed and gauged Skelton shutter (Factory made) 35mm thick of second class hard wood open rebated & prepared to receive glass, gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut & mitred beads for securing glass etc size of members of shutters as specified in SSR Part I Section 8, clause8.20 (a) including Kiln seasoned and chemically pressure treated, complete all as specified & directed. 38 Factory made flush shutters 30mm thick,solid core construction, with block board core and plywood face panels, commercial type on both sides,complete all as specified and directed. 39 200mm aluminum anodized barrel tower bolts of extruded section, complete all as specified. 40 Aluminum alloy, anodized, sliding door bolt 300mm long hasp , staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed complete all as specified and directed. 41 Butt hinges 100mm size, of extruded aluminum alloy with galvanisedmild steel hinge pin, anodised, type B-21, complete all as specified and directed. 42 300mm mild steelordinary rat tail rod pattern spring including roller and roller plate, complete all as specified and directed. 43 Aluminium handles, fabricated type anodized of size 150 mm, ISI marked, complete all as specified. 44 Floor door stopper of aluminum alloy body and tongue, anodized with hard drawn steel spring, fixed in floor (150mm size),complete all as specified and directed. 45 Preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. 46 Plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in surface channel and drain complete all as specified & directed. 47 Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds , mitred /stopped ends etc complete all as specified & directed. 48 25mm thick PCC 1:2:4(using 12.5mm, type B-0 graded stone aggregate) Damp proof course to horizontal or vertical surfaces including necessary formwork complete, all as specified and directed. 49 25mm dia stainless steelcurtain rod including fixing fancy types brackets, stops, rollers etc.,complete all as specified and directed. 50 Mild steel work as in iron for perlin, rafter, post / posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290-W (Gde.E-165) and fixing at site complete all as specified and directed. 51 Glazed coloured ceramic tiles in vertical surface 450mm x 300mm x 7mm thick thick , set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 10mm thick rendering in cement mortar 1:4 finished rough to fix tilescomplete all as specified and directed. 52 Rounding of / moulding to edges of stone of any description including rubbing and polishing (Granite finish) complete all as specified and directed. 53 Sink mixer, cast copper alloy, cast copper alloy chromium plated, screwed for iron pipe or for union, suitable for 15mm bore pipe,complete all as specified and directed. 54 Sink with drainage board made out of stainless steel sheet 1.0mm thick with plug, washers and wastes, overall size 915 x 460mm, bowl size 410x330x160mm incl fixing cantilever brackets and connection to union, pipe,complete all as specified and directed. 55 PVC(SWR) rain water pipe, 110mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mmincluding nuts bolts etc,complete all as specified and directed. 56 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed by Engineer-in-charge. 57 110mm bore PVC (SWR) bends any radius with access door etc complete all as specified and directed 58 110mm bore PVC (SWR) tee with access door etc complete all as specified and directed 59 75mm bore PVC (SWR) tee with access door etc complete all as specified and directed 60 PVC (SWR) floor trap, plain with grating includingjointing with solvent cement75mm bore, including jointing to waste pipe set in cement concrete type B-1(1:2:4) , complete all as specified. 61 Preparation of new steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint complete all as specified & directed. 62 20mm diaGI tubing medium grade with all fittings , fixed into walls, ceiling or laid under floorscomplete all as specified and directed. 63 15mm diaGI tubing medium grade with all fittings , fixed into walls, ceiling or laid under floorscomplete all as specified and directed. 64 Corner glass shelf 300mm dia with brass brakets,complete all as specified and directed. 65 Sheet glass shelf assembly consisting of 5.5mm thick sheet glass 12cm wide with CP bracket guard and railing 60cm long,complete all as specified and directed. 66 Brass, chromium plated, tubular towel rail 20 mm dia. ‘D’ type, 60 cm long between flanges including brackets,complete all as specified and directed. 67 Waste fittings brass chromium plated 40mm size for china ware sinks/basins etc with long screw shanks and flynuts, flanges and bedded in red lead cement complete all as specified and directed. 68 Beveled edge looking mirror, 5.5mm thick of selected quality glass, including wood finish PVC mouldingmounted on 6mm thick ply or of PVC frame fixed to wall with screw and rawl plugs, complete all as specified and directed. 69 15mm dia PVC connection with PTMT nut,of length 900mm, complete all as specified and directed. 70 500 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) double layered, screwable lid, hoisted and fixed in position, including tank nipple, float valve, ball valve 15mm borePTMT,all as specified in SSR Part-I and all as directed by Engineer-in-charge. 71 Factory made 18mm thick solid WPC (Wood Polymer Composite) board of density 650 Kg /cum of one sideprelaminated / rigidlam with any colour and other side balancing laminate as in cup board/ kitchen cabinet shutter/ drawer, front shuters, fixed with screws, solvent/ adhesive complete all as specified and directed. 72 Continuous piano hinges havign flap width 40mm when open mild steel,bright finish or electrogalvanised complete all as specified and directed by Engineer-in-charge. 73 Magnet catcher cum sliencer CP and fixed with standard steel screws,complete all as specified and directed. 74 100mm UPVC pipe (SCH-40) with all fittings, complete all as specified and directed. 75 Factory made, precast concrete interlocking paver block any shape and size withgrey cement and pigment, including 25mm sand cushioningconforming to IS 15658-2006, of 60mm thickness, M-35 Grade completeall as specified and directed. 76 Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.(M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately) Complete all as specidied as per Manefacrurer broucher. 77 Factory made RCC man hole covers, (Medium duty, M-35 Grade) of size 600mm x 1200mm x 75mm with plain faces, including MS frame, set in position in cement mortar 1:4 complete all as specified and directed. 78 3mm thick Atactic polypropylene polymer (APP) based polymeric membrane minimum weighing 3.6kg/sqm andreinforced with polyester non woven fabric (weight not less than 150 gm/sqm) laid over a coat of bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS, over primer coat bonding material of blown bitumen 85/25 grade heated to working temperature of 180° C applied @1.2Kg/Sqm. The membrane shall be laid using butane torch and sealing all joints etc after preparing the surface as per standard practice and as per manufacturer instructions , complete all as specified & directed. 79 Factory made machine pressed cement concrete tiles 250mm x 250mm x 22mm thick , set, jointed and pointed in neat cement slurry with grey cementlaid over and including 15mm thick screed bed in cement mortar 1:6,complete all as specified and directed 80 10mm thick rendering in Cement and Sand mortar 1:4 mixed with WPCover roof slab and parapets finished even and fair without using extra cement all as specified and directed.Note : WPC will be measured and paid separately. 81 Salt- glazed stoneware drain pipe grade ‘A’ 150mm bore, ISI marked, jointed with cement mortar, laid in trenches and tested including fittings of same grade complete all as specified and directed. 82 Plain cement concrete 1:4:8 type D-2, using 40mm graded crushed stone aggregate as in packing under and haunching against the sides of pipes (150mm bore pipe) after the pipe are laid and tested including making good and preparing the existing bedding to receive new pipecomplete all as specified and directed. 83 Counter Top Basin, Size 700 x 435 x 135mm, coloured white, fixed in position,complete all as specified and directed.Make : Jaquar ARS-WHT-39903 or equivalent as approved in Appx "C" 84 Single lever extended basin mixer, without Popup waste and 450mm Long Braided Hoses, cast copper alloy, cast copper alloy chromium plated, screwed for iron pipe or for union, suitable for 15mm bore pipe, complete all as specified and directed. Make : Jaquar OPP-15011BPM or equivalent as approved in Appx "C" 85 4mm thick False ceiling fibre cement board, white in colour , 595mm x 595mm in size, fire and moisture resistance, fixed with and including standard GI snap grid framing (Powder coated) and suspended not exceeding 900mm below from ceiling with 3mm dia wire including clips and misc fittings etc in pattern as approved by GE, (size of panel shall be of 605 x 605mm and GI snap grid framing shall be of 1mm thick standard section i.e. channels, angles, tee etc) complete all as specified and directed. 86 Plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in lintels up to 1.5 m clear span, cills, steps, seismic and other similar bands, hold fast, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, water through and the like including weathering, slightly rounded or chamfered angles and throating including use of form work (straigth or curved) complete all as specified & directed(Note :-reinforcement where provided shall be measured and paid seprately) 87 2mm thick fibre glass reinforced translucent plain coloured sheeting with side lap, fixed with ‘L’ type or ‘J’ type or cranked hook, bolts, nuts, bituminous washer, self tapping screws as in roof, wall etc complete all as specified and directed. 88 Excavation in post holes (or similar hole) each in hard & dense soil n.exc 0.50 cu m getting out, returning, filling and ramming earth or broken rubble mixed with earth around, in layers not exc 25 cm, watering and removing surplus spoil at a distance not exc 50 metre and making good surfaces complete all as specified and directed. 89 Pre-painted galvalume aluminum zinc coating (AZ-70) GI based corrugated steel sheet 0.50mm thick in any colour and patteren as approved by the GE of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and directed. 90 Material and labour forpoint wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single coremulti stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including provn ofnew modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising ofOne light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note for serial item No 72 to 75: Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account. 91 All as per serial item 90 herein before but for socket outlet 3 pin 5 Amps on same board complete all as specified and directed 92 All as per serial item 90 herein before but for socket outlet 3 pin 6 Amps on independentboard complete all as specified and directed 93 All as per serial item 90 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSHcable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor 94 Switch modular type (ISI marked), single pole, one way 6 Amps, one module(ISI marked), complete all as specified & directed. 95 Switch modular type (ISI marked), single pole, one way 16 Amps, one module(ISI marked), complete all as specified & directed. 96 Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose combined two module (ISI marked), complete all as specified & directed. 97 Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. 98 Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed. 99 Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specifiedand directed by Engineer-in-charge. 100 Lamp holder, PVC/Polycarbonate type with back plate angular type fixed on wall suitable for batten fitting ,complete all as specified and directed. 101 LED lamp9 watts, B-22 type (inverter bulb)complete all as specified . 102 Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 125 to 160Amps & outgoing 4 way having IP 54 protection Complete all as specified and directed . 103 MCCB, 125 Amps, four pole, 3 phase , 16KA, 415 volt with adjustable thermal andmaganetic release, with proper thimble complete all as specified and directed 104 MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting,8 way SPN with 200 Amps busbar 240V completed all as specified and directed. 105 MCB, SPN , 240 volt,32Amps, 10 KA , "C" series including connection with suitable size aluminium / copper lugs complete all as specified and directed 106 MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , "C" series including connection with suitable size aluminium / copper lugs complete all as specified and directed 107 Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed. 108 LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size ,complete all as specified and directed. 109 LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. 110 Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.Note : (i)For the purpose of measurement, 2 single core of 4 sqmm and one single core earth cable of 4 sqmm cableshall be considered as 1 running metre. (ii) PVC conduit and cutting chases will be measured and paid separtely(iii) colour code shall be Red for phase, Black for neutral and green for earth 111 Sub main wiring with two singlecore FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing throughPVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfacesby providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.Note : (i)For the purpose of measurement, 2 single core of 6 sqmm and one single core earth cable of 6 sqmm cableshall be considered as 1 running metre. (ii) PVC conduit and cutting chases will be measured and paid separtely(iii) colour code shall be Red for phase, Black for neutral and green for earth 112 Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth Complete all as specified and directed . 113 20 to 25 mm dia, rigid non metallic PVC concealed conduit, "ISI marked", inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, fixed as in repair Complete all as specified and directed . 114 LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,includinglamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, including taking down old street lght complete all as specified and directed. 115 Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) compelte all as specified and directed. 116 Supply and fix exhaust fan, steel body AC single Phase. 230V of size 380mmsweep with, blades, and frame and louvers compelte all as specified and directed. 117 Dry sand cushioning to underground cables with 8cm thick layer before laying of cables and 15cm thick after laying and stretching of cable complete all as specified and directed. 118 Burnt bricks in trenches, over underground cable for cable protections, width of brick along the length of the trenches complete all as specified and directed. 119 XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm, 3.5 core, laid in trenches , sleeving through pipes of fixed on poles & wall or laid under floors inlcuding jointing with suitable size of alumunium lugs as specified and directed. 120 Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. Note(s) :-(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii)PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include earth lead and protection pipe of length 7.5m(iv)Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.(v) unit rate including protection pipe and GI wire 4.00mm dia from top to earth plate upto 7.5 meter
|