Rental Of Automatic Cpap Device With Heated Humidifier, Connected To Automatic Bivolt Electricity Source, With Low Noise Level, Pressure Of At Least 4 To 20 Cmh2o Or Greater, Integrated Memory Card. Must Come With Reusable Trachea, Nasal Or Oronasal Mask (According To Medical Prescription), Dust Filters, Present Registration With Anvisa Of The Equipment. Quarterly Technical Visits With A Physiotherapist To Monitor The Use And Functioning Of The Equipment And Change Disposables When Necessary., Rental Of Automatic Bipap Device With Heated Humidifier, Inspiratory And Expiratory Pressure Ipap/Epap From, 4 To 25 Cmh2o Or Greater, Cpap From, 4 To 20 Cmh2o, With Credit Card Memory, Must Accompany Reusable Trachea Or Circuit, Tracheostomy Adapter, Register With Anvisa Of The Equipment. Quarterly Technical Visits With A Physiotherapist To Monitor The Use And Functioning Of The Equipment And Change Disposables When Necessary., Rental Of An Oxygen Concentrator. Minimum Gas Flow: Flow Rate Of 0.5 To 5 Liters Per Minute. Minimum Oxygen Concentration At Maximum Flow: 93% +/- 3% Maximum Acoustic Noise Level Produced By The Compressor: 50Dba. The Device Must Have Casters, Allowing Easy Movement. Device For Flow Control In Increments Equal Or Less Than 0.5 Liter Per Minute. Have Filters To Remove Dust, Bacteria And Other Particles. Alarm System To Indicate Defects And Complications, Such As O2 Pressure Drop, Electrical Power Failure, Low O2 Purity, O2 Concentration Outside Of Parameters. Electrical Supply: Units Must Be Made Available For The 127 Volt, 60 Hz And 220 Volt 60Hz Network, Depending On The Electrical Installation Of The Patients Residence. Maximum Power Of 350 Watts, With Variation Of Up To 5%. Equipment Degree Of Protection Ipx1 Or Ip21. Equipment For Continuous Operation. Accompanied By An Auxiliary Oxygen Cylinder Of 4 To 10 M³ To Be Kept As A Safety Reserve Next To Each Concentrator, Which Must Have A Cart Or Support And Regulating Valves With A Pressure Gauge, Humidifiers, 7-Meter Extension Cords, Adult And/Or Childrens Face Masks , Masks For Adult And/Or Childrens Tracheostomy, Adult Silicone Nasal Cannulas And/Or Childrens, As Accessory Items. The Backup Cylinder Will Only Be Used In Cases Of Power Outage Or Failures That Impair The Functioning Of The Oxygen Concentrator, It Cannot Be Used As A Primary Source Of Oxygen, Only For Emergencies. Quarterly Technical Visits With A Physiotherapist To Monitor The Use And Functioning Of The Equipment And Change Disposables When Necessary., Rental Of An Oxygen Concentrator. Minimum Gas Flow: Flow From 1.0 To 10 Liters Per Minute. Minimum Oxygen Concentration: 92 +/- 4%. Maximum Acoustic Noise Level Produced By The Compressor: 55Dba. Have Casters, Allowing Easy Movement. Device For Flow Control In Increments, Equal Or Less Than 1.0 (One) Liter Per Minute. Have Filters For Dust Removal, Such As O² Pressure Drop, Low O² Purity, O² Concentration Outside The Parameters. Electrical Supply: Units For A 127 Volt Network Must Be Made Available, Depending On The Electrical Installation Of The Patients Residence (If The Residence Only Has 220 Volts 60Hz Voltage And Does Not Have Equipment Available At That Voltage, An Additional Power Transformer Can Be Provided.
|