Tender For Provision Of Otm Accommodation Of Rou At Saugor; 1 Note:-Please refer schedule "A" notesbefore quoting the tender.(ii) Amount of Schedule of credit shall be deducated off line by the department. 2 GENERAL SUMMARY 3 Lump sum price worked out by the contractor for BUILDING WORK as listed in Schedule ‘A’ Part-I (Ref prepriced schedule attached separately). 4 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’Part- II (Ref prepriced schedule attached seperately) 5 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’Part- III (Ref prepriced schedule attached seperately) 6 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’Part- IV (Ref prepriced schedule attached seperately) 7 Lump sum price worked out by the contractor for EXTERNAL ELETRICWORKS as listed in Schedule ‘A’Part- V (Ref prepriced schedule attached seperately) 8 Lump sum price worked out by the contractor for ROAD PATH & CULVERT WORKSas listed in Schedule ‘A’Part- VI (Ref prepriced schedule attached seperately) 9 Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule ‘A’Part- VII(Ref prepriced schedule attached seperately) 10 Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’Part-VIII(Ref prepriced schedule attached seperately) 11 Lump sum price worked out by the contractor for RETAINING WALL WORKS as listed in Schedule ‘A’Part-IX(Ref prepriced schedule attached seperately) 12 Lump sum price worked out by the contractor for FENCING, GATE AND COMPOUND WALL WORKS as listed in Schedule ‘A’Part-X(Ref prepriced schedule attached seperately) 13 Lump sum price worked out by the contractor for LIGHTING PROTECTION WORKSas listed in Schedule ‘A’Part-XI (Ref prepriced schedule attached seperately) 14 Lump sum price worked out by the contractor for DEMOLITION/ DISMANTLING WORKSas listed in Schedule ‘A’Part-XII (Ref prepriced schedule attached seperately) 15 Lump sum price worked out by the contractor for EXCAVATION, EARTH WORK AND SITE DEVELOPMENT WORKSas listed in Schedule ‘A’Part-XIII (Ref prepriced schedule attached seperately) 16 SCH "A" Pt - XIV (MISCELLANEOUS ITEMS) 17 INTERNAL ELETRIFICATION WORKS NOTE:- For items of internal Electrifications notes given at the beginning of Sch ‘A’ Part-III (internalElectrification Works) shall also be applicable. 18 M&L point wiring for lightpoint wiring complete with 2x 1.5 Sq.mm PVC insulation unsheathed muilt-starnded FRLSH copper conductor 1100 Volts grade for phase & neutral draw through in and including not less than 20 mm dia & 1.8 mm thick PVC conduit and conduit accessories, concealed in walls and terminated to and including provision of modular flush boxes adequate size & thick ness not less than 1.6mm with modular metal frame plate and white cover for housing switch, sockets, regulators etc, including 1.5 sqmm PVC insulated unsheathed multi-stranded FRLSH copper conducotor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for the following points .NOTE;-The quoted rate is deemed to inclusive of cost of metal flush boxes, modular white cover plate and blank plate. 19 (a) One light point controlled by one way 6A modular switch. 20 (b) One fan point controlled by one way6A modular switch. 21 (c) One Exhaust fan point controlled by one 6 Amps one-way modular switch 22 (d) One Wall fan point controlled by one 6 Amps one-way modular switch 23 (e) One Bell Buzer point controlled by one 6 Amps bell push switch 24 (f)One Socket Outlet contolled by 6 Amps modular switch on Independent board 25 (g) One Socket Outlet controlled by 6 Amps modular switch on same board 26 All as per Sl item No. 4.01 above, but with cable 2.5 sqmm for phase and neutral & 2.5 sqmm for earth continuity complete for 6/16 Amps socket point 27 M & L for Point wiring using approved colour coding as per IS ( Red, Black and Green for single phase circuits) with multi-stranded copper conductor 1.5 Sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, in stove enamelled steel conduit and conduit accessories concealed in wall/roof/floor etc. ISI marked , including PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dully complete all as specified and directed by Engr-in-Charge. 28 (a)One light point controlled by one 6/16 amps one way flame proof switch. 29 (b)One Fan point controlled by one 6/16 amps one way flame proof switch. 30 (c)One Exhaust Fan point controlled by one 6/16 amps one way flame proof switch. 31 (d) One Socket Outlet controlled by 6/16 Amps flame proof switch on same board 32 All as per Sl item No. 4.10 above, but with cable 2.5 sqmm for phase and neutral & 2.5 sqmm for earth continuity complete for 6/16 Amps Flame prrof socket point 33 S&F Wall mounted fan , plastic body, AC single phase 230V, 400mm sweep copper wound with connecting three core cable from ceiling rose complete all as specified and directed by Engr-in-Charge. 34 Supply & fixing flame proof exhaust fan of size 300 mm sweep,motor 0.25 HP,1440 RPM, AC single phase 230V with blades , frame andlouver,complete all as specified and directed by Engr-in-Charge. 35 Supply & fixing flame proof Ceiling fan of size 1200 mm sweep,motor 0.25 HP,1440 RPM, AC single phase 230V with blades , complete all as specified and directed by Engr-in-Charge. 36 Supply & Fixing flame proof down light 40 watt, cool day white, IP-65 protection & not less than 100 Lm/watt complete all as specified and directed by Engr-in-Charge. 37 S&F Sheet metal enclosure for pre wired distribution board double door, vertical type powder coated triple pole & Neutral (VTPN) 4 way with out MCCB, three phase 415 volt with 200 Amps rated tinned electrolytic copper bus bar with neutral link complete concealed in wall complete all as specified and directed by Engr-in-Charge. 38 S&F Sheet metal enclosure for pre wired distribution board double door,powder coated triple pole & Neutral (TPN) 4 way with out MCCB, three phase 415 volt with 200 Amps rated tinned electrolytic copper bus bar with neutral link complete concealed in wall complete all as specified and directed by Engr-in-Charge. 39 S&F Sheet metal enclosure for pre wired distribution board double door,powder coated triple pole & Neutral (TPN) 6 way with out MCCB, three phase 415 volt with 200 Amps rated tinned electrolytic copper bus bar with neutral link complete concealed in wall complete all as specified and directed by Engr-in-Charge. 40 S & F LED Security light fitting 25 Watt, system luman efficacy of LED not less than 120 luman/W, PF> 0.95, THD < 10%, colour temprature 6000 to 6500K, CRI > 70, system lumen not less then 3000 Lm, made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens with toughed glass having bottom separate driver compartment with IP 66 Protection and Impact resistant of IK 07 etc and all accessories previewed complete including mounting bracket of 40 mm inner dia light grade GI pipe of required length and shape incl bending, forging or welding etc and suitable bolts and nuts with washers, including connecting with PVC insulated multi stranded copper flexible cable of size 0.5 sqmm three core from ceiling rose to fitting complete all as specified and directed by Engr-in-Charge. 41 S&Ftelephone/ TV socket with shutter, 1 module including modular cover plate, metal flush box (16 Gauge) concealed in wall/roof complete all as specified and directed by Engr-in-charge. 42 Supply & fixing PVC conduit not less than 25 mm dia & 1.8 mm thick for laying of television/teliphone/DTH/ Data Cable, complete all as specified and directed by Engr-in-Charge. 43 Supply & Fixing medium way down light 80 Watt ceiling mounted PDC housing with system efficiancy not less than 125 lumans/ watt, cool white complete all as specified and directed by Engr-in-Charge. 44 Supply & Fixing dragon incandescent light 60 wattcomplete all as specified and directed by Engr-in-Charge. 45 Supply & Fixing Flood Light 150 watt, system luman efficiancy not less than 120 Lm/watt, PF>0.95, THD< 10%, CCt 6000 to 6500K, CRI>70, made up of pressure dia cast aluminium housing with high efficiancy LED as lighting source and lens with toughhed glass, IP-67 including suitable size bracket & suitable size three core copper cable complete all as specified and directed by Engr-in-Charge. 46 EXTERNAL WATERSUPPLY WORKS NOTE:- For items of EXTERNAL WATER SUPPLY WORKS notes given at the beginning of Sch ‘A’ Part-IV (EXTERNAL WATER SUPPLY WORKS) shall also be applicable. 47 M & L for DI fittings as in bends (any type, radius and angle) Tapers and y type, (straight, bends increasing, or double socket etc. (Tee pieces single branch, ‘Y’ junction, double branch, cross (all socket or socket and spigot) collars caps and plugs etc. complete all as specified and directed. 48 Supply, laying, connecting, jointing and testing centrifugally cast (Spun) Ductile iron pressure pipe 150mm dia ISI marked confirming to IS-8329-2000(Reaffirmed 2005 edition 4.1) of following size with socket spigot ends, suitable for “Plus on joints (Tyton Joint)” each standard working lengths supplied with rubber gaskets duly ISI marked for water supply class K-9 with socket with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe without polyethylene sleeves but including “Push on Joint” supplied with ISI marked EPDM rubber gasket conforming to IS-5382-1985 (reaffirmed 2003) laid in trenches complete all as specified and directed. 49 Supply, laying, connecting, jointing and testing centrifugally cast (Spun) Ductile iron pressure pipe 80mm dia ISI marked confirming to IS-8329-2000(Reaffirmed 2005 edition 4.1) of following size with socket spigot ends, suitable for “Plus on joints (Tyton Joint)” each standard working lengths supplied with rubber gaskets duly ISI marked for water supply class K-9 with socket with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe without polyethylene sleeves but including “Push on Joint” supplied with ISI marked EPDM rubber gasket conforming to IS-5382-1985 (reaffirmed 2003) laid in trenches complete all as specified and directed. 50 M & L for construction of brick masonry valve pit chamber for the size of 900x 900x1000 cm including necessary earth work, PCC coping plastering on internal surface of valve pit. Framed work for the valve pit chamber cover made of MS sheet angle equal angle 40x40x5 mm and MS sheet 3mm thick confirming to Fe410-o and Fe310-o including welding cutting hinges locking arrangement complete and two coated synthetic paints applied on the valve pit cover and MS frame work complete all specified in drawing and directed by Engr-in-charge 51 EXTERNAL ELETRICWORKS NOTE:- For items of EXTERNAL ELECTRIC WORKS notes given at the beginning of Sch ‘A’ Part-V (EXTERNAL ELETRIC WORKSshall also be applicable. 52 Supply and fix junction box Single Pole and neutral enclosure compression gland2with connector and clamp for pole mounting with two nos of nut bolt and washers and socket complete of size not less than 12"x10"x4" complete all as specified by Engineer -in- Charge. 53 Supply and fix in replacement of time switches for street lights control for 3 KW Single Phaserating consists of the following items :- (a) Lumens sensor model No -02EC-3KW1P or equivalent(b) contactorAC3 20 Amps per phase - 01 No (c) Incoming MCB of 20 Amps per phase- 01 Nos (d) Outgoing MCB of 20 Amps per phase - 01 Nos (e) complete single phase circuit wiring 54 S & F oftubing galvanised 40 mm bore light gradeISI marked bent to the shape of bracket 1.2 Mtr in length for mounting of street light fitting and fixed on pole with clamp and nut, bolt and washerwith two coat paint complete all as directed. 55 M&L for supply, install, connecting and commissioning ofCPRI approved main LT distribution panel board IP-54 (Main Panel) , outdoor type, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4 Nos insulated bus bar each made of high conductivity aluminium suitable for 630 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following. (Main Panel)(A) INCOMING(i) MCCB, 4 Pole, 415V, 50HZ 320 Amps with rupturing capacity 36 KA-01Nos (B) OUTGOING(i) Digital Multifuction meter withselector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED type Phase indicator lamps for three phases set of three - 01 set(iii) Busbar chamber having insulatedAluminium busbar, each suitable for 630 Amps for three phases and neutral -01 set(iv) MCCB, 4 Pole,415V, 50HZ 125 Amps with rupturing capacity 25 KA-01 Nos(v) MCCB, 4 Pole,415V, 50HZ 100 Amps with rupturing capacity 16 KA-03Nos(vi) MCCB, 4 Pole, 415V, 50HZ 63 Amps with rupturing capacity 10 KA-03Nos(vii) MCB, 4 POLE of capacity32 AMPS,10 kA at 415V = 01 56 M&L for supply, install, connecting and commissioning ofCPRI approved main LT distribution panel board, IP-54(Accilaries) , outdoor type, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4 Nos insulated bus bar each made of high conductivity aluminium suitable for 200 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following. (LT Panel No 3)(A) INCOMING(i) MCCB, 4 Pole, 415V, 50HZ 100 Amps with rupturing capacity 16 KA-01Nos (B) OUTGOING(i) Digital Multifuction meter withselector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED type Phase indicator lamps for three phases set of three - 01 set(iii) Busbar chamber having insulated aluminium busbar, each suitable for 200 Amps for three phases and neutral -01 set(iv) MCCB, 4 Pole,415V, 50HZ 63 Amps with rupturing capacity 10 KA-01 Nos(v) MCB, TPN,415V, 50HZ 63 Amps with rupturing capacity 10 KA-01 Nos(vi) MCCB, 4 POLE of capacity40 AMPS,10 kA at 415V = 01(viii) MCB, SPN of capacity16 AMPS,10 kA= 05 57 M&L for supply, install, connecting and commissioning ofCPRI approved main LT distribution panel board, IP-54(adm block) , outdoor type, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4 Nos insulated bus bar each made of high conductivity copper suitable for 200 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following. (LT PANEL No 1)(A) INCOMING(i) MCCB, 4 Pole, 415V, 50HZ 125 Amps with rupturing capacity 25 KA-01Nos (B) OUTGOING(i) Digital Multifuction meter withselector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED type Phase indicator lamps for three phases set of three - 01 set(iii) Busbar chamber having insulated aluminium busbar, each suitable for 200 Amps for three phases and neutral -01 set(iv) MCCB, 4 Pole,415V, 50HZ 63 Amps with rupturing capacity 10 KA-01 Nos(v) MCB, 4 POLE of capacity40 AMPS,10 kA at 415V = 02(vi) MCB, SPN of capacity 32 AMPS,10 kA= 02 58 M&L for supply, install, connecting and commissioning ofCPRI approved main LT distribution panel board, IP-54 (S/Line Accn) , outdoor type, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4 Nos insulated bus bar each made of high conductivity aluminium suitable for 200 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following. (LT PANEL No 4)(A) INCOMING(i) MCCB, 4 Pole, 415V, 50HZ 125 Amps with rupturing capacity 25 KA-01Nos (B) OUTGOING(i) Digital Multifuction meter withselector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED type Phase indicator lamps for three phases set of three - 01 set(iii) Busbar chamber having insulated aluminium busbar, each suitable for 200 Amps for three phases and neutral -01 set(iv)MCB, 4 POLE of capacity40AMPS,10 kA at 415V = 02(v) MCB, SPN of capacity32 AMPS,10 kA= 02 59 M&L for supply, install, connecting and commissioning ofCPRI approved main LT distribution panel board, IP-54 (Bulk store half part, WT) , outdoor type, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4 Nos insulated bus bar each made of high conductivity aluminium suitable for 200 Amps, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following. (LT PANEL No. 2)(A) INCOMING(i) MCCB, 4 Pole, 415V, 50HZ 63 Amps with rupturing capacity 16 KA-01Nos (B) OUTGOING(i) Digital Multifuction meter withselector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED type Phase indicator lamps for three phases set of three - 01 set(iii) Busbar chamber having insulated aluminium busbar, each suitable for 200 Amps for three phases and neutral -01 set(iv) MCCB, 4 Pole of capacity40 AMPS,10 kA at 415V = 02(v) MCB, SPN of capacity 32 AMPS,10 kA= 02 60 S&F in HT cable route indicator made of RCC M15 (Noiminal Mix) ( using 12.5mm nominal size crushed stone aggregate) of size 200mm (Length)X200mm (Width)X1200mm (Height) duly painted with cement base and written in white colour with lettering MES HT cable /HT straight Joint using two coats of synthetic enamel paint in black colour and including necessary earthwork and excavation, embedded in PCC block foundation in M15 (Nominal Mix)(using 20 nominal graded crushed stone aggregate) of size 400mm x 400mm x 300mm complete all as specified and as directed. 61 SEWAGE DISPOSAL WORKSNOTE:- For items of SEWAGE DISPOSAL WORKS notes given at the beginning of SCHEDULE "A" PART -VIII (SEWAGE DISPOSAL WORKS) shall also be applicable. 62 S & F of DWCPE (double wall corrugated) sewagepipe SN-8 ISI Mark as per IS 16908Part Ii 2013 laid in trenches joined and tested as per manufactures instruction complete all as specified and directed for the following size:- 63 (a)150 MM bore pipe 64 (b) 200 MM bore pipe 65 Construction ofBrick Septic Tank of 150 Users includingexcavation, in any type of soil, PCC foundation, walls of fly ash brick masonry with top cover of M25 concrete including intercepting chamber and screen chamber made ofBrick masonary in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCI complete as specified (TD No CEBZ/TD/77/2011 Sheet 1/3 to 3/3) 66 Construction of Soakage well includingexcavation, in any type of soil, PCC foundation walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made ofBrick masonary in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats3.00m depth x 3.00m effective depth for150 Users complete all as specified and directed (Drg NoCEBZ/TD/78/2011 sheet 1/2 to 2/2. 67 Fencing, Gate and Comound Wall WorksNOTE:- For items of Fencing, Gate and Comound Wall Works notes given at the biginning of Schedule "A" Part-X (Fencing, Gate and Comound Wall Works)shall also be applicable. 68 Provision of steel gate of size 8.0 mtr wide all as shown in on drg No CEBZ/TD/104/2011 Sheet No 1/3 to 3/3 with MS work confirming to Fe 290 Gde E-165 including gate pillar and necessary earthwork etc. complete all as specified and directed.Note:- Contractor shall make provision of gate light, however gate light shall be measured an paid separately as per requirement. 69 Excavation earth work and site development wotksNOTE:- For items of Excavation earth work and site development wotks notes given at the beginning of SCHEDULE "A" PART -XIII (Excavation earth work and site development wotks) shall also be applicable. 70 Approved earth filling with approved soil brought from outside MD land filling in tranches or paving laid in layers not exceeding 25 cm thick spread, levelled rammed including watering etc. complete all as specified and directed. 71 Internal Water Supply WorksNOTE:- For items of Internal Water Supply Works notes given at the beginning of SCHEDULE "A" PART -II (Internal Water Supply Works) shall also be applicable. 72 S&F of two way bib tabs, cast copper alloy fancy type with crutch or butterfly handle, screwed down, screwed for 15mm dia iron/CPVC pipe or for brass ferrule and fixed complete all as specified and directed.
|