(L1) 6510.82571-Diaphragm, Use: Stethoscope Headset, Units. Measurement: Unitary, (L2) 6511.73325-Electrode, Type: Straight Knife, Use: Surgical Procedures, Measurement: 150Mm, Material: Stainless Steel Rod, Coated With Heat Shrinkable Spaghetti, Additional Features: Monopolar, (L3) 6511.71166-Sensor Proximal Flow, Type: Neonatal, Use: Lung Ventilator, (L4) 6511.71167-Proximal Flow Sensor, Type: Pediatric, (L5) 6601.78900-Blood Collection Tube, Material: Glass, Capacity: 1.0Ml To 2.0Ml, Color: Red Cap , Packaging: Box With 24 Units, Additional Features: Other Information In Accordance With The Term Of Reference And/Or Technical Description Of The Process, 11/22/2024, (L6) 6510.25669-Vacuum Gauge From 0 To 76 Cm Hg, With Manometer Designed For Exclusive Coupling To A Vacuum Network To Control Suction From Pumps Vacuum, Intended For Aspirating Secretions, In Polypropylene, Reservoir Made Of Thermoplastic Material For Aspiration, Autoclavable, With A Completely Smooth Texture So As Not To Retain Particles After Cleaning, Must Have A Raised Scale, With A Minimum Capacity Of 400Ml, (L7) 6510.25672-Pressure Regulator For Oxygen Cylinder, With Flowmeter, Has The Function Of Reducing The Output Pressure At Gas Stations. Consumption Of Medicinal Gases For Working Pressure Of 3.5 Kgf/Cm², Flowmeter To Control And Indicate The Flow Of Oxygen To Be Supplied To Patients, Must Have A Body Made Of Polished And Chromed Brass, Floating Needle System Made Of Brass, Part Polished And Chrome-Plated Exterior, Interior With Chemical Cleaning Treatment, Steering Wheel Made With Insert Brass Internal Injected Later With High-Resistance Thermoplastic (Nylon) In Standard Color According To Abnt Standard 254, Output Connection Made Of Chromed And Differentiated Brass According To Abnt Standard 257, Input Connection (Niple) Made Of Polished And Chromed Brass, Standardization According To Standard 254 Abnt, Confec Nut With Metallic Insert And Chrome Plated With Treatment Cleaning Chemical And Subsequently Injected In High-Resistance Thermoplastic With Standardized Colors According To Standard 254 Abnt, Confec Measuring Tube In Transparent And Unbreakable Polycarbonate Double Conical With Scale From 0 To 15 Liters/Minute With An Expanded Scale From 0 To 7 And Linear From 7 At 15 Liters/Minute, Garnish Made In Transparent Polycarbonate And Unbreakable Stainless Steel Ball Float, Also With The Function Of Controlling The Flow Of Gas To Be Administered To The Patient, Reducing Valve Made Of Polished Brass, Chromed, Completely Clean And Free Of Grease/Oils And Stainless Steel, Inlet And Outlet Connections, Standardized Abnt, Easy-To-Read Pressure Gauge With Scale 0-315 Kgf/Cm2.Input Pressure: Up To 200 Kgf/Cm², Output Pressure: 3, Manometer: High Pressure And Dual Scale Of Kgf/Cm² From 0 - 315, Additional Features: Allow The Option For Long Or Short Cables
|