Tender For Provn Of Remote Control Cable Between Tech Buildings, Geyser In L/In Accn, Highmast Light In Domestic Area Along With Special Repair Of Wiring And Fittings Alongwith Associated Items; 1 Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 mtr depth for laying of cable and getting out in any type of soil.( Note :-Depth for excavation is 1 mtr and width is 0.5 mtr) 2 Removing of excavated surplus soil not exc 50 m and deposited where directed at a level not exc 1.5 m above the starting point. 3 Returning, filling in, including spreading, leveling, watering and well ramming in layer not exc 25 cm thick 4 M & L for sand cushioning to all around the cable protection of natural Tibba sand all as directed.(Note : Punning thickness will be measured and paid for payment purpose.) 5 S & L stone patti quarry faced Jodhpur type 4 to 5 cm thick and 25 to 30 cm wide putting on cable abutting to each other for cable protection all as directed. 6 M & L PCC 1:3:6 type C1 using 20 mm graded stone aggregate for pedestal of pole. Complete all as directed by Engineer-in-Charge. 7 M & L for kerB / road / path cutting for laying of cables upto required width and requried depth n.exc 1.5 mtr complete all as specified and directed. 8 Supply and laying of High density polyethylene pipes (HDPE) of pressure rating 6 Kgf/cm2 laid in trenches for size 95 MM borecomplete all as directed by Engineer-in-Charge. 9 Laying only of cable 2 core upto a maximum size of 1.5 Sqmm in ground complete.Note- Cable for above subject work will be provided by CCR Section of 5 FBSU, Necessary test certificate by OEM and testing of cable before and after laying will be the sole responsibility of CCR authorities. MES will not held responsible for any type of failure in system/ network or any damage/ non function of items/ accessories proposed to be connected.Continuity and IR test will be carried out by joint team of CCR and MES rep before and after laying of each section of cable and the same will be endorse in writting. 10 Fixing only of cable 2 core upto a maximum size of 1.5 Sqmm by using clamps , nuts and bolts on wall/ pole complete.Note- Cable for above subject work will be provided by CCR Section of 5 FBSU, Necessary test certificate by OEM and testing of cable before and after laying will be the sole responsibility of CCR authorities. MES will not held responsible for any type of failure in system/ network or any damage/ non function of items/ accessories proposed to be connected.Continuity and IR test will be carried out by joint team of CCR and MES rep before and after laying of each section of cable and the same will be endorse in writting. 11 Supply and fixingsheet metal enclosure for DBs single pole and neutralwith busbaras per sample complete all as specified and directed by Engineer in charge 12 Supply and fixingsingle pole MCB 16 Amp 240 v 10 KA C curvecomplete all as specified and directed by Eng-in-charge 13 Supply and fixing cable route indicator made of MS angle iron 50x50x6 mm and 0.90 mtr long and welded 10 cm dia 6 mm thick plate on top and embosed the letters as "AB CABLE" duly embedded in ground with PCC 1:2:4 type B1 all as directed 14 S&F metal unbreakable junction box (Dim- 1x1x0.3 RM)( with lock and key) duly paintedYellow colour out door type suitable for pole mountedincluding copper bus bar 2 pole x 10 amp complete with FI clamp, nuts, bolts, washers, MS angle 45X45X3 mm two length of1.8 mtr each for fixing of junction box complete 15 M &L for providing hard copy of line diagram of UG cable from alternate ATC to main ATC after laying of cable complete all as specified and directed. 16 M & L for boring of holes using HDD technique underpavementusing ultra sound technique and necessary machine complete all as directed . 17 S&F polycarbonate unbreakable junction box suitable for change over box 3 pole toggle switches with terminal block 12 nos pole as per sample complete with FI clamp & nuts, bolts, washers complete all as specified and directed by Engr-In-Charge. 18 Supply and Installation of Solar water heating system having vacuum tube outer diameter : 47 mm, temperature range: 60 degree C to 85 degree C, tank insulation: PUF 55 mm to 60 mm, Stand frame: Aluminium Polyster Powder coated, inner Tank material : stainless steel 316 L grade 0.7 mm, outer tank : aluminium polyster powder coated, electrical Back up: 3 KW each, method of welding: 37 mm, Vacuum Tube inner diameter; 480 mm, Tube length : 1800 mm and capacity : 300 litre per day capacitywith electrical heating back up complete all as specified and directed. 19 Supply and Installation of Solar water heating system having vacuum tube outer diameter : 47 mm, temperature range: 60 degree C to 85 degree C, tank insulation: PUF 55 mm to 60 mm, Stand frame: Aluminium Polyster Powder coated, inner Tank material : stainless steel 316 L grade 0.7 mm, outer tank : aluminium polyster powder coated, electrical Back up: 3 KW each, method of welding: 37 mm, Vacuum Tube inner diameter; 480 mm, Tube length : 1800 mm and capacity : 500 litre per day capacitywith electrical heating back up complete all as specified and directed. 20 Taking down carefully to existing copper/Aluminum point wiring (light,socket or power) complete includingfittings such as switches, ceiling roses, pendents, sockets, boxes, light fitting etc and removing from site and making good disturbed surfaces of walls, floors etc complete all as specified. 21 M&L for Point wiring concealed type with PVC insulated and unsheathed multistranded FRLSH copper conductor single core 1.5 Sqmm (nominalarea) cable using approved colour code as per IS drawing in and incl concealed PVC conduit (ISI Mark) of required size with all accessories including providing providing sunk cast pressed steel terminal boxes off size made out of 1.5mm thick MS sheet duly painted with black bitumen paint over a coat of red oxide primer and providing suitable size mounting plates complete accessories for mounting of modular switch/sockets alongwith copper earth wire PVC insulated & unsheathed multistranded (FRLSH) copper conductor cableof size 1.5 Sqmm as continous earth wire connected to common earth and earth dolly complete all as specified. 22 One light / Fan / Bell point controlled by one way switch 6/5 Amp . 23 One light point controlled by two way switch 6/5 Amp . 24 One 3 pin socket outlet 6/5 Amps on the same board with other switches 25 One 3 pin 6/5 Amp socket outlet controlled by one switch onindependent board 26 M&L Point wiringof Power point concealed type contolled by one 15 Amp switch independent with PVC insulated and unsheathed multistranded FRLSH copper conductor single core 2.5 Sqmm (nominalarea) cable using approved colour code as per IS drawing in and incl concealed PVC conduit (ISI Mark) of required size with all accessories including providing providing sunk cast pressed steel terminal boxes off size made out of 1.5mm thick MS sheet duly painted with black bitumen paint over a coat of red oxide primer and providing suitable size mounting plates complete accessories for mounting of modular switch/sockets alongwith copper earth wire PVC insulated & unsheathed multistranded (FRLSH) copper conductor cableof size 2.5 Sqmm as continous earth wire connected to common earth and erth dolly complete all as specified and as directed. 27 S&F in repair switch piano flush modular type (ISI marked), single pole, one way 6/5 Amp, 240 Volts complete all as specified & directed. 28 S&F in repair switch piano flush modular type (ISI marked), single pole, two way 6/5 Amp, 240 Volts complete all as specified & directed. 29 S&F in repair switch piano flush modular type (ISI marked), single pole, one way 16/15 Amp, 240 Volts complete all as specified & directed. 30 S&F in repair switch socket combination 2 in 1, 3 pin, 6/5 Amp piano flush modular type (ISI marked),240 Volts complete all as specified & directed. 31 S&F in repairsocket2 in 1, 3 pin, 16/15 Amp piano flush modular type (ISI marked),240 Volts complete all as specified & directed. 32 S&F in repairswitch socket combination 2 in 1, 3 pin, 16/15 Amp piano flush modular type (ISI marked),240 Volts complete all as specified & directed. 33 S&F in repair lamp holder insulatedbodywith back plate suitable for batten fittings complete all as specified & directed. 34 S&F in repairceiling rose, surface bakelite, three terminals complete all as specified & directed. 35 S&F in repair stepped type electronic fan regulator flush modular type complete all as specified & directed. 36 S&F in repair Bell push piano modular type one way 6/5 Amp, 240 volt complete all as specified & directed. 37 S&F in repair Bell electric AC 240 volt, 50 HZ complete all as specified & directed. 38 S&Fin repair LED tube light fitting 4" long, 20/18 Watt single phase 230 V with illumination efficiency more than 120 Lumen/Watt, 3000K/6000K, decorative tuneable white browse through mood changing colour options type slim ultra bright LED polycarbonate tube fixture with extruded heat shrink, environmental friendly energy efficientwith very high efficiency to give glare free lightat light source incl integrated electronic drivercomplete all as specified and directed. 39 S&F in repair Light mirror light fitting 2" long, 10/20 Watt single phase 230 V with illumination efficiency more than 120 Lumen/Watt, 3000K/6000K, decorative tuneable white browse through mood changing colour options type slim ultra bright LED polycarbonate tube fixture with extruded heat shrink, environmental friendly energy efficientwith very high efficiency to give glare free lightat light source incl integrated electronic drivercomplete all as specified and directed. 40 S&F wall mounted decorative ornamental type light fitting complete with driver, holder, LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete incl dismentling taking down unsv fitting any type comple all as specified and directed. 41 S&F in repair environmental friendly, ultra modern, energy saving, surface mounted decorative hexagon LED bulk head 10Wincluding connecting up with 0.5 sqmm two core copper flexible conductor cable complete all as specified and directed. 42 S&F in repair LED inverter lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF not less than 0.85 (min) complete all as specified and directed . 43 S&F in repair LED inverter lamp 9 watt, CDL, B-22 cap, (Pin type), 230V, PF not less than 0.85 (min) complete all as specified and directed . 44 S&FLED building security light 25 Watt, 230 V new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 with high power LEDs as light source with electronic driver and connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable including taking down old LED light along with all accessories complete all as specified and directed. 45 Supply and fixing security light Bracket made out of galvanised steel light grade pipe of 32mm dia 0.8 mtr long bend to an angle of 120 degree with 02 Nos clamp made out of 25mm x 5mm flat iron with nuts, bolts and washers painting with two coats of synthetic enamel paint over a coat of red oxide primer including taking down complete all as specified and directed. 46 M&L for sub main wiringwith two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC Conduit concealed type of suitable size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly including cutting chases in brick/block/stone wall wherever necessary, replastering and making good to match with existing surfaces and taking down unserviceable one complete all as specified and directed.NOTE: (a)Two run of cable with one run of earth wire and one run of conduit ISI Marked will be measured as one length. (b) Unit rate includes for cutting chases for cunduits and sunken boxes and making good. 47 M&L for sub main wiringwith two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sqmm (Nominal area) drawn through in and including PVC Conduit concealed type of suitable size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sqmm as earth lead and connected to earth dolly including cutting chases in brick/block/stone wall wherever necessary, replastering and making good to match with existing surfaces and taking down unserviceable one complete all as specified and directed.NOTE: (a)Two run of cable with one run of earth wire and one run of conduit ISI Marked will be measured as one length. (b) Unit rate includes for cutting chases for cunduits and sunken boxes and making good. 48 S&F MCB DB CRCA sheet powder coated VTPNDB LL 4 way double door factory made suitable for incorporating MCB as out going and MCCB as incoming including connecting incoming and outgoing cables and flush to wall by making the hole in the wall and fixing the DB with cement work and plastering to match with existing surfaces incl taking down existing unsv DB of any size complete all as specified and as directed. 49 S&F MCB DB CRCA sheet powder coated SPN 8 way double door factory made suitable for incorporating MCB as out going connecting incoming and outgoing cables and flush to wall by making the hole in the wall and fixing the DB with cement work and plastering to match with existing surfaces incl taking down existing unsv DB of any size complete all as specified and as directed. 50 S&F MCB SPN having braking capacity 10 KA, 35 to 60 Amp, 240 volts "C" curve incl taking down unserviceable one complete all as specified and as directed. 51 S&F MCB single pole having braking capacity 10 KA, 6 to 32 Amps 240 volts "C" curve incl taking down unserviceable one complete all as specified and as directed. 52 S&F MCCB 100 Amps, Four Pole,16 KA, 415 Voltincl taking down unserviceable one complete all as specified and as directed. 53 S&F Square shaped surface suspended mounted environment friendly new generation asthetically ultra modern with high brightness LEDs as light source LED Flat panel, 36 watt, 2"x2"size, complete with driver and all accessories and including connecting up to with two core copper flexible conductor cable incl dismentling taking down unsv fitting any type complete all as specified and directed. 54 S&F Square shaped recess suspended mounted environment friendly ultra low depth and light weight new generation asthetically ultra modern with high brightness LEDs as light source LED Flat panel, 36 watt, 2"x2"size, complete with driver and all accessories and including connecting up to with two core copper flexible conductor cable incl dismentling taking down unsv fitting any type complete all as specified and directed. 55 S&F round shaped recess/surface suspended mounted slim fit down lighter having latest edge lit LED techonology environment friendly, 18 watt complete with driver and all accessories and including connecting up to with two core copper flexible conductor cable incl dismentling taking down unsv fitting any type complete all as specified and directed. 56 S&F Square shaped recess/surface suspended mounted environment friendly new generation asthetically ultra modern with high brightness LEDs as light source LED Flat panel, 40 watt, 1"x4"size, complete with driver and all accessories and including connecting up to with two core copper flexible conductor cable incl dismentling taking down unsv fitting any type complete all as specified and directed. 57 S&F decorative hanging type surface suspended mounted hexagonal environment friendly new generation asthetically ultra modern with high brightness LEDs as light source to large hexagonal meticulously welded to resemble uniform light softens up to over all light source and exemplifies illumination on a grand scale, 40 watt, complete with driver, hanging wire assembly and all accessories and including connecting up to with two core copper flexible conductor cable incl dismentling taking down unsv fitting any type complete all as specified and directed. 58 S&F LED Cylinder surface mounted light with black powder coated aluminum housing and pressure die-cast heat sink having high efficiency with high brightness LEDs as light source, 30 watt, complete with driver and all accessories and including connecting up to with two core copper flexible conductor cable incl dismentling taking down unsv fitting any type complete all as specified and directed. 59 S&F in replacement Post top energy saving, LED post-top Aesthetically designed IP 65 LED post top with aluminium enclosure, powered with high power LEDs as light source and die casted heat sink exhibits classic Victorian look with symmetrical light distribution and excellent heat dissipation for long life of capacity 50 Watt, 6500K complete all as specified and as directed by Engr-in-charge. 60 M&L for surface sub main wiringwith two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduitsize with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 1.0 sqmm as earth lead and connected to earth dolly including taking down unserviceable one and making good to disturbed surfaces complete all as specified and directed. NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length. 61 S&F in replacement indoor type LED Step wall lighting specially designed for auditorium complete all as specified and directed. 62 S&F in replacement indoor type LED Sign Light Box wall lighting specially designed for auditorium welcome/exit gate or as per directed specifications complete all as specified and directed. 63 M&L for Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit nbot less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below notmal ground level, connected to galvanised earth lead wire 4.0mm dia by means of suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1,precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI wire protection pipe 25mm bore up to main board complete as shown in electrical plate No 3 of MES schedule Part-I 2009, connected to earthing testing point complete all as specified and testing on completion complete all as specified and as directed. Note:- The units rate including the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 25mm GI pipe (light grade) for watering 25mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made. 64 Supply of 15 meter High mast Lighting tower, Suitable for wind speed of 180 km/hr (maximum) with detailed Technical specifications as mentioned below:Thickness: Top- 3 mm & Bottom- 4 mmDiameter: Top-150 mm & Bottom-360 mm Cross section of High Mast- 20 sided Polygon, with stress slip fit joints. Lantern Carriage- 40 Nb Erw Class-B M.S Pipe, 600 mm Long diameter of Carriage ring (In 2 segments) with 9 Arms Welded, suiitable for 9 Nos. of Fixture type- 250Watt Led Flood light Winch Capacity- Double drum winch having Capacity of 500 Kg Height of high mast-15 Meters metal protection Treatment- Hot Dip Galvanised As per is- 4759/ is 2629 and Thickness of galvasnization must be 70 Microns Average Non Flame Proof TypeMotor 1.5 Hp Integral Type Reversible Also for automatic operation of lowering and raising lanternCarriag SS wire ropes-Total -5 Nos (3 Nos for lantern and 2 Nos for Double drum wich) 6 mm316 grade Ss Hoisting Ropes of 7/19 Trailing Cable- 1 per Mast (5 Core 25 sq mm) Lighting finial 1200 mm G.I Foundation bolt having 850 mm lengths along with washers and nuts, lightnening Arrester wiht Led Aviation light Single Dome including feeder pillar/ Control Panel Note: Rates of Foundations are as per Oem including on qouted rates. 65 Supply and fixing LED street flood light fitting 250 watt elegently disingned, pressure die cast aluminium housing in powder coated finish IP-66, Lumen efficacy>=120/Lm/W and total Limens Output Must be + 30,000 lumens or more, Operating Voltage Range 120-270, P.F>0.95, Dimensions of the fitting shall not be less than 345 Mm x 345 Mm x 70 Mm (Higher dimensions can be accepted), Cct -5700K, Surge Protector of 10 KV inside fitting, Dirver of the fitting shall be potted type only for vibration proof performance with over voltage protection & other features Like-APFC for Power factor correction, inbuilt surge arrester (In dirver)4 KV, over voltage protection> 300 VAC, 440 V withstand for continous 8 Hrs. both fixture and driver must have separate bis marked registration with clearly mentio0ned on fixture & as well as on driver. the manufacturer of the led fiting shall have inhouse nabl accrediated lab & contractor shall furnish same along with Lm-79, Lm80, test report etc.oncliding making connection with 3 core X 2.5 sqmm FLRSH wire, all as per directed by Engineer-in-charge 66 M&L for supplying, laying , connecting and tersting in trenches, under floors/roads or on walls Cable XLPE insulated screened PVC bedded galvanised steel strips or wire armoured, electric power cables (heavy duty) ISI marked with stranded aluminium conductor 1100 volts grade of 25 sqmm 4 core all as per specified anddirected by Engineer-in-charge. 67 M&L earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cm x 60cm x 6.0mm thick, buried directly vertically in ground in a pitdepth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 25 x 4 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel.Earthing strip shall be protected by galvanised iron or steel pipe 32 mm bore light grade and connected to continuous earth wire on pole / test point. The earthing shall be of inclusive of excavation & earth work in any type of soil/strata,charcoal dust common salt, PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe medium grade for watering complete all as specified and directed.Note: (i)Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any additional length shall be paid seperately. (ii) Ontesting after completion, if the desired earth resistance is not obtained, the earthing will be redone at no extra cost by the contractor 68 S&F galvanised iron strip of size 25 x4 mm as earth continuity conductor buried in ground or fixed to wall/floor/ground provided with porcelain insulators space no less than 0.5 mtrs complete all as specified and directed. 69 Supply and fixing LT cable route indicator cast ironof suitable size mounted on 40 x 40 x 3 mm angle iron with height of 1.5 metre along with LT cable trench including planting in ground with PCC complete all as specified and directed by Engineer-in-charge.
|