Modernization and System Augmentation works in KESCo namely viz. Supply and erection work related to construction of New Sub-stations, capacity enhancement of Power Transformer, additional Power transformer, 33 kV Lines, 11 kV Lines, Augmentation of 33 kV and 11 kV Lines, Reconductoring, Installation of new DT, Augmentation of DT, Construction of L.T. Lines with bare conductor and AB cable and Erection/replacement of Protection/Switching Devices/Switchgears -Rdss Modernization System Augmentation Work , Power Transformers , Supply Of 33/11 Kv Outdoor 10 Mva Power Transformer With Oltc, Rtcc Panel & Other Standard Accessories As Per Technical Specifications And Relevant Is. , Supply Of 33/11 Kv Outdoor 10/12.5 Mva Onaf Dual Rating Power Transformer With Oltc, Rtcc Panel & Other Standard Accessories As Per Technical Specifications And Relevant Is. , Supply Of 33/11 Kv Outdoor 20 Mvaonaf Power Transformer With Oltc, Rtcc Panel & Other Standard Accessories As Per Technical Specifications And Relevant Is. , 33 Kv Switchgear , Supply Of 33 Kv Gis Panels With 2 Line Bays, 2 Transformer Bays, One Bus Coupler Bay, Bus Pt, All Complete With Numerical Relays, Facility For Data Transmission And Remote Control Including Pt Raiser Panel, Any Other Equipment Required For Commissioning. , Supply Of 30 Kv, 1-Phase, 10 Ka Lightning Arrestor For Gis With All Accessories As Per Ts , Supply Of 36 Kv 1250 A Outdooor Vacuum Circuit Breaker Confirming To Iec 62271-100, Iec 62271-200 With Breaking Capacity Of 25 Ka For 3S And Making Capacity Of 62.5 Ka With All Required Mounting Structure And Standard Accessories Along With Ct Structure. , Supply Of 36 Kv 1250 A Indoor Vacuum Circuit Breaker With Crp (Outgoing) , Supply Of 36 Kv 1250 A Indoor Vacuum Circuit Breaker With Crp (Incomming) , Supply Of 36 Kv 1250 A Indoor Vacuum Circuit Breaker Bus Coupler With Adopter Panel/Trunk Chamber , Supply Of Control & Relay Panel For 33 Kv Feeder With Iec 61850 Scada Protocol Compatible & Numerical O/C And E/F Protection , Supply Of Control & Relay Panel For Double Power Transformer With Iec 61850 Scada Protocol Compatible Differential Protection , Supply Of Control & Relay Panel For Single Power Transformer With Iec 61850 Scada Protocol Compatible Numerical Differential Protection , Supply Of 33 Kv Gapless Metal Oxide Outdoor Lightning Arrestor, 30 Kv Rms Arrestor Rating , Supply Of 33 Kv Single Phase, Dead Tank Type Out Door Current Transformer (400/200/1-1 A) Having 0.5 Accuracy Class Confirming To Is:2705-1992 (Part I-Iv)/Iec- 185, Iec-60044 , Supply Of 33 Kv Single Phase, Dead Tank Type Out Door Current Transformer (200/100/1-1-1 A) Having 0.5 Accuracy Class Confirming To Is:2705-1992 (Part I-Iv)/Iec- 185, Iec-60044. , Supply Of 33 Kv /110V Single Phase, Dead Tank Type Out Door Oil Cooled Potential Transformer Confirming To Is 3156 , Supply Of Outdoor Type 33 Kv, 3-Phase, Triple Pole, Double Break, Gang Operated, Centre Rotating 800 A Line Isolators On Double Rod Turn & Twisting System Confirming To S: 9921(Part I To V) & Iec Publication No. 129 , Supply Of Outdoor Type 33 Kv, 3-Phase, Triple Pole, Double Break, Gang Operated, Centre Rotating 800 A Bus Isolators On Double Rod Turn & Twisting System Confirming To Is: 9921(Part I To V) & Iec Publication No. 129 , Supply Of 33 Kv 400Amp D.O. Fuse Set Along With Channel & Clamps , Supply Of Outdoor Type 33 Kv, 3-Phase, Triple Pole, Double Break, Gang Operated, Centre Rotating 800 A Line Isolators For Mid Line Four Pole Structures , 11 Kv Switchgear , Supply Of 11 Kv Gis Panels With 6 Line Bays, 2 Transformer Bays, 1 Station Transformer Bay & One Bus Coupler Bay, Bus Pt, All Complete With Numerical Relays, Facility For Data Transmission And Remote Control This Includes Pt Raiser Panel, Any Other Material Required For Commissioning.(Scada Compatible & 61850 Protocol Compliant Protection Relays) , Supply Of 12 Kv, 350 Mva, 1600 A, 25 Ka Incommer Panel Vcb (600-300/1-5-5A Three Core Ct)(Scada Compatible & 61850 Protocol Compliant Protection Relays) , Supply Of 12 Kv, 350 Mva, 1600 A, 25 Ka Incommer Panel Vcb (800-400/1-5-5A Three Core Ct) (Scada Compatible & 61850 Protocol Compliant Protection Relays) , Supply Of 12 Kv, 350 Mva, 1600 A, 25 Ka Outgoing Panel Vcb (400-200/5-5A Two Core Ct) With Same Make Vacuum Interrupter. (Scada Compatible & 61850 Protocol Compliant Protection Relays) , Supply Of 12 Kv, 350 Mva, 1600 A, 25 Ka Outgoing Bus-Coupler Panel Vcb (400-200/5-5A Two Core Ct) With Same Make Vacuum Interrupter. (Scada Compatible & 61850 Protocol Compliant Protection Relays) , Supply Of Adapter Panels For Inter-Connection Of Bus Bar Of 11 Kv Vcbs Of Different Designs , Supply Of 11 Kv 100 Amp D.O. Fuse Set Along With Channel & Clamps , Supply Of Outdoor Type 11 Kv, 3-Phase, Triple Pole, Double Break, Gang Operated, Centre Rotating 400 A Line Isolators (To Be Mounted On Pole) On Double Rod Turn & Twisting System Along With Gi Pipe And Handle Confirming To Relevant Is , Supply Of 9 Kv, 1-Phase, 10 Ka Lightning Arrestor For Gis With All Accessories As Per Ts , Power Cables , Supply Of 19/33 Kv 3Cx400 Sq. Mm Xlpe Cable , Supply Of 19/33 Kv 3Cx300 Sq. Mm Xlpe Cable , Supply Of 33 Kv 1Cx400 Sq. Mm Xlpe Cable , Supply Of 6.6/11 Kv 3Cx300 Sq. Mm Xlpe Cable , Supply Of 6.6/11 Kv 3Cx185 Sq. Mm Xlpe Cable , Supply Of 6.6/11 Kv 3Cx70 Sq. Mm Xlpe Cable , Heat Shrinkable Joints , Supply Of Heat Shrinkable Indoor Cable Termination Kit For 11 Kv 3Cx300 Sq.Mm. Cable , Supply Of Heat Shrinkable Outdoor Cable Termination Kit For 11 Kv 3Cx300 Sq.Mm. Cable , Supply Of Heat Shrinkable Outdoor Cable Termination Kit For 11 Kv 3Cx185 Sq.Mm. Cable , Supply Of Heat Shrinkable Indoor Cable Termination Kit For 33 Kv 3Cx400 Sq.Mm. Cable , Supply Of Heat Shrinkable Outdoor Cable Termination Kit For 33 Kv 3Cx400 Sq.Mm. Cable , Supply Of Heat Shrinkable Outdoor Cable Termination Kit For 33 Kv 3Cx300 Sq.Mm. Cable , Supply Of Heat Shrinkable Indoor Cable Termination Kit For 11 Kv 3Cx70 Sq.Mm. Cable , Supply Of Heat Shrinkable Outdoor Cable Termination Kit For 11 Kv 3Cx70 Sq.Mm. Cable , Supply Of Heat Shrinkable Straight Through Jointing Kit For 33 Kv Xlpe 3X400 Sqmm , Supply Of Heat Shrinkable Straight Through Jointing Kit For 11 Kv Xlpe 3X300 Sqmm , Poles , Supply Of 13 M Long Steel Tubular Poles With Welded Steel Base Plateand Of Designation410 Sp-71 (Is 2713 Pt I, Ii, Iii) And Bottom Galvanised As Per Is 2629 (1985) , Supply Of 11 M Long Steel Tubular Poles Bottom Galvinized With Welded Steel Base Plateand Of Designation410 Sp-55 (Is 2713 Pt I, Ii, Iii) And Bottom Galvanised As Per Is 2629 (1985) , Supply Of 9.5 M Long Steel Tubular Poles With Welded Steel Base Plateand Of Designation410 Sp-37 (Is 2713 Pt I, Ii, Iii) And Bottom Galvanised As Per Is 2629 (1985) , Supply Of 9 M Long Pcc Pole (M42 Concrete Grade) , Supply Of Lattice M+4 Galvanized Ms Tower Structure , Supply Of Hot Dipped Galvanized Rolled Joist Poles 152X152x 11.9 Mm With Base Plate 7 M ( H-Beam/Joist Girder) And Holes Punched At Required Positions , Supply Of Hot Dipped Galvanized Rolled Joist Poles 152X152 X11.9 Mm With Base Plate 4 M ( H-Beam/Joist Girder) And Holes Punched At Required Positions , Distribution Transformers & Accessories , Supply Of 11/0.4 Kv 63 Kva T/F With Breather, Conservators, Arcing Horns, Attached Mccb With Crca Protective Casing And Other Standard Accessories , Supply Of 11/0.4 Kv 250 Kva T/F With Breather, Conservators, Arcing Horns, Attached Mccb With Crca Protective Casing And Other Standard Accessories , Supply Of 11/0.4 Kv 400 Kva T/F With Breather, Conservators, Arcing Horns, Attached Mccb With Crca Protective Casing And Other Standard Accessories , Supply Of 11/0.4 Kv 250 Kva T/F With Breather, Conservators, Arcing Horns And Other Standard Accessories , Supply Of 11/0.4 Kv 400 Kva T/F With Breather, Conservators, Arcing Horns And Other Standard Accessories , Supply Of 11/0.4 Kv 400 Kva Compact Sub-Station With Inbuilt Ht/Lt Protection And All Standard Accessories , Supply Of Bushing Boots For Distribution Transformer , Supply Of T/F Fencingof Frame Size 3X2.4 Mtr. With Gate And Latch(Size Of Fencing May Vary As Per Site Conditions) Including Cost Of M.S. Angle Size 40X40x5 And M.S. Flat Size 50X6, Fixing Of Welded Steel Wire Fabric On Steel Frames By Welding Of 10 Swg Wire Fabric, Including Painting Of Two Coats Of Paint On Iron Based Surfaces With Ready Mixed Paint To Give Bus Green Shade Including Cleaning Of Oil And Dust. Additional Ms Strips 40X5 Sqmm Having Height Same As That Of Fencing To Be Placed Vertically On The Steel Wire Fabric At A Distance Of 0.5 M From One Another For Additional Reinforcement. , Supply Of T/F Fencingof Frame Size 3X2.4 Mtr. With Gate And Latch(Size Of Fencing May Vary As Per Site Conditions) Including Cost Of M.S. Angle Size 40X40x5 And M.S. Flat Size 50X6 Including Painting Of Two Coats Of Paint On Iron Based Surfaces With Ready Mixed Paint To Give Bus Green Shade Including Cleaning Of Oil And Dust. Additional Ms Strips 40X5 Sqmm Having Height Same As That Of Fencing To Be Placed Vertically On The Steel Wire Fabric At A Distance Of 75 Mm From One Another For Additional Reinforcement. , Supply Of Gi Cable Tray For Housing Of Lt & Ht Cables Of Size 300M Wise X 1500M Long , Supply Of L.T. Circuit 500 V /500 A( Tail-Less Unit) , Conductors , Supply Of 6/4.72 Mm+7/1.57 Mm (100 Mm² Al. Area) - Acsr Dog Conductor , Supply Of Acsr Panther Conductor , Supply Of Al59 Acs Covered Dog Conductor , Lt Xlpe Cables , Supply Of3.5 Cx25 Sq Mm. Xlpe , Supply Of 3.5 Cx240 Sq Mm. Xlpe Armoured Cable , Supply Of 3.5 Cx300 Sq Mm. Xlpe Armoured Cable , Supply Of 3.5 Cx120 Sq Mm. Xlpe Armoured Cable , Supply Of 3.5Cx70 Sq Mm Xlpe Armoured Cable , Supply Of 1Cx400 Sqmm.Xlpe , Supply Of 2Cx6 Sqmm.Xlpe Armoured Service Cable , Supply Of 2Cx10 Sqmm.Xlpe Armoured Service Cable , Supply Of 2Cx16 Sqmm.Xlpe Armoured Service Cable For Street Light , Supply Of 4Cx16 Sqmm.Xlpe Armoured Service Cable , Supply Of 4Cx25 Sqmm.Xlpe Armoured Service Cable , Supply Of 1Cx25 Sqmm.Xlpe , Supply Of Lt Cable Ferrules For Consumer Identification, Cable Tracing, Etc. Per Dt , Supply Of Aerial Bunched Xlpecable 3X120+1X95+1X16 Sqmm , Supply Of Aerial Bunched Xlpecable 3X150+1X125+1X16 Sqmm , Control Cables , Supply Of Control Cable 2 Cx2.5 Mm² , Supply Of Control Cable 4 Cx2.5 Mm² , Supply Of Control Cable 6 Cx2.5 Mm² , Supply Of Control Cable 10 Cx2.5 Mm² , Sub-Station Accessories , Supply Of Co2 Cylinder 4 Nos Of 4.5 Kgs Supply And Fixing Of Co2 Type Fire Extinguishers Capacity Confirming To Is 2878 Made Isi Mark (1 Set) , Supply Of Isi Make Abc Power Map 2 Kg Fire Extinguisher Mono Ammonium Phosphate Power 50, Stored Pressure Type, Complete With Pressure Guage And All Accessories Applicable On Class A,B,C Electrically Started Fler As Per Building Ssr. , Supply Of Synthetic Rubber Mats As Per Is 15652 In Control Room 2.5 Mm Thick , Supply Of 24 V, 80Ah, Ni-Cd Sealed Type Battery Set And All Other Accessories Complete. , Supply Of Float-Cum-Boost Battery Charger (Smps Based ) With Full Wave, Full Control Rectification, 50Hz Input Voltage For Charging 24V, 80 Ah Battery Along With Dcdb, Connectors, Surge Protection Device, Etc. Complete And Connection With 24 V, 80Ah Battery Set And Single Phase Ac Input Supply. , Supply Of Float-Cum-Boost Battery Charger (Smps Based ) With Full Wave, Full Control Rectification, 50Hz Input Voltage For Charging 24V, 80 Ah Battery , Supply Of 415V Ac Distribution Board/Panel Of Sheet Steelenclosed Cubical With Surge Protection Device Floor Mounting Type For Catering Auxiliary Power Supply Of The Substation Etc. , Supply Of 415V Ac Distribution Board/Panel Of Sheet Steelenclosed Cubical Without Surge Protection Device Floor Mounting Type For Catering Auxiliary Power Supply Of The Substation Etc. , Supply Of 24V Dc Distribution Board/Panel Of Sheet Steelenclosed Cubical , Supply Of Sand Bucket Stand With 6 Nos. Buckets. , Supply Of Ct /Pt Junction Box , Ms Items/Galvanized Items , Supply Of Pre-Fabricated Galvanized Steel Items Like V Cross Arm, Top Clamp, F/E Bracket, Clamps, Cross Bracings,Strain Plate, Guarding Channels, Back Clamp, Transformer Mounting Structure, Terminal Gantry Structute Etc Made Of Ms Channels (100X50x6mm), Ms Angle (65X65x6mm), M.S./G.I. Strip (50X6 Mm),M.S. Strip (75X8 Mm), Any Other Ms Material Not Inluded Elsewhere. All Materials Shall Be Of The Approved Size Duly Galvanisedfor Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. (Including Required Fabrication Work, If Any) , Supply Of Pre-Fabricated Non-Galvanized Steel Items Like Ms Channel, Ms Angle , M.S./G.I. Strip (50X6 Mm),M.S. Strip (75X8 Mm), Ms Rail Pole Non Galvanzied (For Power Transformer Placement) Ms Round(Non-Galvanized) Of 40 Mm Dia And 3000 Mm Long, Any Other Ms Material Not Inluded Elsewhere. All Materials Shall Be Of The Approved Size As Per Technical Specification, Approved Drawings And Scope Of Work. (Including Required Fabrication Work, If Any) , Supply Ofms Nuts, Bolts With Washers(Duly Galvanised) As Per Technical Specification, Approved Drawings And Scope Of Work (Off Size). , Supply Of Gi Pipe For External Area Of Small Cable To Houses(50Mm Dia) , Supply Of Gi Pipe For External Area Of Small Cable To Houses (40 Mm Dia) , Supply Of Gi Pipe For Cable Riser(150 Mm Dia) , Insulators , Supply Of 11 Kv Disc Fitting B & S Type (70 Kn) For Bearing Weight Of Dog Conductor , Supply Of Polymeric 11 Kv Disc Insulators B&S Type 70 Kn. , Supply Of Porcelain 11 Kv Disc Insulators B&S Type 70 Kn. , Supply Of 11 Kv Polymerpin Insulators 10 Kn With Gi Pin , Supply Of 11 Kv Porcelain Pin Insulators 10 Kn With Gi Pin , Supply Of 33 Kv Polymer Pin Insulator With Gi Pin , Supply Of 33 Kv Porcelain Pin Insulator With Gi Pin , Supply Of 33 Kv Disc Fitting B & S Type (70 Kn) For Bearing Weight Of Panther Conductor , Supply Of Disc Fitting For Covered Conductor , Supply Of Disc Insulators For Covered Conductors , Supply Of Hdpe Spacers For Covered Conductors , Supply Of Lt Pin Insulator With Gi Pin , Supply Of Lt Shackle Insulator With Shackle Strip , Pole Accessories , Supply Of Dead End Clamps With Eye-Hook And Holding Clamp Required For Stp/Pcc Pole(Insulated) , Supply Of Suspension Clamps With Eye-Hook And Holding Clamp Required For Stp/Pcc Pole(Insulated) , Supply Of Lt Insulated Piercing Connectors Of 25-150 Sqmm Size For Energizing Distribution Kiosk/Box , Supply Of Lt Insulation Piercing Connectors Of 25-120 Sqmm Size For Energizing Distribution Kiosk/Box , Supply Of New Galvanised Stay Set With Anchor Plate (200X200x6mm), 50X8mm Stay Clamp, Stay Guy Insulator, Nut Bolts, 2 No Turn Buckles, 1.8 M Long, 16 Mm Diameter Solid Gs Stay Rod & 7/3.15 Mm Dia Gi Stranded Wire Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. , Supply Of Spike Earthing 2540Mm Longmade Of 20Mm Gi Solid Rod. , Supply Of Suitable 33 Kv Brackets/Cross Arms With Adequate Insulating Materials And Any Other Minor Accessories Required For Single M+4 Tower , Supply Of 8 Swg Gi Wire , Supply Of L.T. Neutral Bare Connector. , Supply Of Ci Packing (Galvanised) As Per Site Requirement. , Supply Ofdanger Plate , Supply Ofg.I. Barbed Wire , Supply Of Stone Pad 300X300mm For Pcc Pole , Distribution Boxes , Single Phase Crca Ms Deep Drawn Distribution Box With Clamps With And All Accessories. , Three Phase Crca Ms Deep Drawn Distribution Box With Clamps With Lug And All Accessories. , Supply Of Crca Ms Deep Drawn Junction Box With 1500 Mm Long Gi Pipe 40 Mm Dia With Clamp And Ms Angle Stand (For Street Light Connection) , Supply Of Single Phase Smc Distribution Box With Clamps. , Supply Of Three Phase Smc Distribution Box With Clamps. , Supply Of Outdoor Type Lt Distribution Box With A Rupturing Capacity Of 50 Ka At 415 Volt Called For Individual Items (Cpri Approved Manufacturer) Openable In Front & Back Suitable For 3 Phase, Four Wire, 50 Hz Ac Supply & An Ambient Temperature Of 45 Deg. C. The Cubicle Should Be Weather Proof, Dust Proof, Bremen Proof And In Closer Protection Shall Be Ip-65 As Per Is 2147- 1962 And Is-8623 The Panels & Switches Boards Shall Be Fabricated Out Of 2Mmcrca Sheet Steel & Provided With 2 Mm Hinged Door Including Suitable Foundation, Main Lt Panel At Substation- 400 Kva (Type A-2) (Incomer - 1 Set Of 800 Amp.Acb With Inbuilt Mpr Released With (On/Off Indicating Light) (Metering On Incomer- 1 Set Of Digital Ammeter With Ass) (1 Set Of Digital Voltmeter With Vss) (1 Set Of Led Type Phase Indication Light (22.5 Mm) With Control Mcbs) (Outgoing - 6 Sets Of 250 Amp. Tp Mccb With Spreader & Extended Handle (5No.+1No. Capacitor Panel)) (2 Sets Of 100 Amp. Tp Mccb With Spreader & Extended Handle) , Supply Of Outdoor Type Lt Distribution Box With A Rupturing Capacity Of 50 Ka At 415 Volt Called For Individual Items (Cpri Approved Manufacturer) Openable In Front & Back Suitable For 3 Phase, Four Wire, 50 Hz Ac Supply & An Ambient Temperature Of 45 Deg. C. The Cubical Should Be Weather Proof, Dust Proof, Bremen Proof And In Closer Protection Shall Be Ip-65 As Per Is 2147- 1962 And Is-8623 The Panels & Switches Boards Shall Be Fabricated Out Of 2Mm Sheet Steel & Provided With2mmhinged Door Including Suitable Foundation, Main Lt Panel At Substation- 250 Kva (Type A-3) (Incomer - 1 Set Of 630 Amp. Acb With Inbuilt Mpr Released With (On/Off Indicating Light) (Metering On Incomer- 1 Set Of Digital Ammeter With Ass) (1 Set Of Digital Voltmeter With Vss) (1 Set Of Led Type Phase Indication Light (22.5 Mm) With Control Mcbs)) (Outgoing - 5 Sets Of 250 Amp. Tp Mccb With Spreader & Extended Handle (4No.+1No. Capacitor Panel)) (2 Sets Of 100 Amp. Tp Mccb With Spreader & Extended Handle) , Supply Of Outdoor Type Lt Distribution Box With A Rupturing Capacity Of 50 Ka At 415 Volt Called For Individual Items (Cpri Approved Manufacturer) Openable In Front & Back Suitable For 3 Phase, Four Wire, 50 Hz Ac Supply & An Ambient Temperature Of 45 Deg. C. The Cubical Should Be Weather Proof, Dust Proof, Bremen Proof And In Closer Protection Shall Be Ip-65 As Per Is 2147- 1962 And Is-8623 The Panels & Switches Boards Shall Be Fabricated Out Of 2 Mm Crca Sheet Steel & Provided With 2 Mm Hinged Door Including Suitable Foundation, Main Lt Panel At Substation- 160 Kva (Type A-4) (Incomer - 1 Set Of 400 Amp. Acb With Inbuilt Mpr Released With (On/Off Indicating Light) (Metering On Incomer- 1 Set Of Digital Ammeter With Ass) (1 Set Of Digital Voltmeter With Vss) (1 Set Of Led Type Phase Indication Light (22.5 Mm) With Control Mcbs) (Outgoing - 4 Sets Of 250 Amp. Tp Mccb With Spreader & Extended Handle (3No.+1No. Capacitor Panel)) (2 Sets Of 100 Amp. Tp Mccb With Spreader & Extended Handle) , Supply Of Outdoor Type Feeder Pillar Panel To Be Made Of 2Mm. Crca Sheet & Covers Will Be 2 Mm Crca Sheet Duly Powder Coated Paint Including Suitable Foundation With 400 Amp. Aluminum Bus Bar(Type B-1) With (On/Off Indicating Light) (Metering On Incomer- 2 Set Of Digital Ammeter With Ass) (2 Set Of Digital Voltmeter With Vss) (2 Set Of Led Type Phase Indication Light (22.5 Mm)Having : 2 No Incomer 250Amp With Changeover Facility.6 Set Of Out-Going 100 Amp Hrc Fuse With Suitable Housing. , Supply Of Outdoor Type Feeder Pillar Panel To Be Made Of 2Mm. Crca Sheet & Covers Will Be 2 Mm Crca Sheet Duly Powder Coated Paint Including Suitable Foundation With 300 Amp. Aluminum Bus Bar(Type B-2) With (On/Off Indicating Light) (Metering On Incomer- 2 Set Of Digital Ammeter With Ass) (2 Set Of Digital Voltmeter With Vss) (2 Set Of Led Type Phase Indication Light (22.5 Mm)Having : 2 No Incomer 250Amp With Supply Changeover & Isolation Facility.5 Set Of Out-Going 100 Amp Hrc Fuse With Suitable Housing. , Supply Of Outdoor Type Feeder Pillar Panel To Be Made Of 2Mm. Crca Sheet & Covers Will Be 2 Mm Crca Sheet Duly Powder Coated Paint Including Suitable Foundation With 300 Amp. Aluminum Bus Bar(Type B-3) With (On/Off Indicating Light) (Metering On Incomer- 2 Set Of Digital Ammeter With Ass) (2 Set Of Digital Voltmeter With Vss) (2 Set Of Led Type Phase Indication Light (22.5 Mm)Having : 2 No Incomer 250Amp With Supply Changeover & Isolation Facility.4 Set Of Out-Going 100 Amp Hrc Fuse With Suitable Housing. , Supply Of Lockable Distribution Box Along Withbar Lock Of Size 450X450mm Including Suitable Foundation With Bus Baramp. 140Tpn To Feed Up To 10 Houses (Type C). Panel To Be Made Of 2Mm. Crca Sheet , Earthing , Supply Ofgi Pipe 40 Mm Dia B-Class 20 Feet Deep For Earthing , Sectionalizers/Fault Passage Indicators , 33 Kv Fpi (Non-Communicable) With All Required Mounting Material , 11 Kv Fpi(Non-Communicable) With All Required Mounting And Commissioning Material , Supply Of 11 Kv ,400 A De-Linking Switch With Required Ms Structure To Be Monunted On Pole , 11 Kv Gang Operated Devices With Required Channel And Other Mounting Material , Supply Of Cable End Termination Using Total Double Compression Brassglands And Crimping Type Aluminum Thimbles Size For L.T. Cables. , 3.5 Cx300 Sq Mm. Xlpe , 3.5 Cx240 Sq Mm. Xlpe , 3.5 Cx120 Sq Mm. Xlpe , 3.5 Cx70 Sq Mm. Xlpe , Hdpe/Pvc Pipe , Supply Ofhdpe Pipe 120 Mm Dia To Be Laid By Horizontal Drilling For Under Ground Piping (Trenchless) At Road Cross Of Above Cable. , Supply Of Pvc Pipe Heavy Gauge 40 Mm Dia (Under Ground Area) Pipe For Small Cable To Houses , Air Circuit Breakers , Supply Of Lt Acb 630A On Dts With Mounting Structure , Supply Of Lt Acb 800A On Dts Having Capacity Greater Than Or Equal To 400 Kva , 33 Kv Gis/Ais Bay , Erection Of 33 Kv Gis Bay By Using Standard Equipments/ Material As Per Upptcl Norms Either By Themself Or By Upptcl In Accordance To Proforma Invoice Provided By Them. , Erection Of 33 Kv Ais Bay By Using Standard Equipments/ Material As Per Upptcl Norms Either By Themself Or By Upptcl In Accordance To Proforma Invoice Provided By Them. , Erection Of 33/11 Kv Gis S/S , Construction Of Power T/F Plinth Suitable For 10 Mva 33/11Kv T/F In Size Of 3.5 X 3.5 X 1.5 Mtr.By Digging Of Pit In Size Of 4.0 X 4.0 X 1.2 Mtr. Of Cc Work And At Bottom In Size Of 4.0 X 4.0 X .15 Mtr. With Ratio Of 1:3:6, Its Proper Ramming And Curing Thereafter Brick Work In Size Of 3.5 X 3.5 X 0.8 Mtr. With 1 : 4 Cc Sand Ratio, Thereafter Cc Work On Top In Size Of 3.5 X 3.5 X .25 Mtr. Thereafter Plastering All Around The Open Portion, Grouting Of Rail And M.S. Angle In Top Cc Work And Its Proper Curing. Reinforcement By Mesh Of Steel Tmt Bar Of Size 12Mm. , Erection, Testing And Commissioning Of 10 Mva, 33/11 Kv Power T/F Along With Radiators, Conservator Tank, Vent Pipe, Rtcc Panel In Control Room And All Other Accessories On Main Tank After Placement Of Rail Pole 3 M Long Including Erection Of Required Number Of Ct/Pt Junction Box And Oil Filling And All Other Related Work/Supply Required For Succesful Commissioning. , Erection, Testing And Commissioning Of 33 Kv Gis Panels With 2 Line Bays, 2 Transformer Bays, One Bus Coupler Bay, Bus Pt, La Etc. All Complete With Numerical Relays, Facility For Data Transmission And Remote Control Including Pt Raiser Panel Etc. And Any Other Auxillary Items Required For Commissioning Along With Supply If Required. , Erection, Testing And Commissioning Of 11 Kv Gis Panels With 6 Line Bays, 2 Transformer Bays, 1 Station Transformer Bay & One Bus Coupler Bay, Bus Pt, La,Etc. All Complete With Numerical Relays, Facility For Data Transmission And Remote Control Including Pt Raiser Panel Etc. And Any Other Auxillary Items Required For Commissioning Along With Supply If Required. , Erection Of 24 V, 80Ah, Ni-Cd Sealed Type Battery Set And All Other Accessories Complete. , Erection Of Float-Cum-Boost Battery Charger (Smps Based ) With Full Wave, Full Control Rectification, 50Hz Input Voltage For Charging 24V, 80 Ah Battery Alongwith Dcdb, Connectors, Surge Protection Device, Etc. Complete And Connection With 24 V, 80Ah Battery Set And Single Phase Ac Input Supply. , Erection Of 415V Ac Distribution Board/Panel Of Sheet Steelenclosed Cubical With Surge Protection Device Floor Mounting Type For Catering Auxiliary Power Supply Of The Substation,Etc. Including Supply Of Wires And Any Other Materials Required. , Erection, Testing And Commissioning Of 63 Kva, 11 Kv/0.415 Kv Station Transformer Along With All Accessories Such As Do Fuse, Bushing Boots, Ht/Lt Side Connections From S/S Panel And Upto Ac Distribution Box(Excluding Laying), Etc. As Per Ts Along With Supply Of Copper L-Joints For Lt Bushing And Any Other Accessories Required. , Erection Of Switchyard Earthing Mat And Near Control Room For 33 Kv Equipments For Double Transformers Of Gis S/S And Related Switchyard Equipments Using Ms Round Bar Of 40 Mm Dia By Pegging And Driving It 50Cm Below Ground Level Including All Fabrication Work Erection Of Required No. Of Delta And Connection Of Equipments With This Mat Using 75X8 Ms Strips. , Erection Of Mounting Structures For Switchyard Euipments, Then Mounting Of Equipments Along With Grouting, Foundation Plinth, Painting Etc And Any Other Required Work , Construction Of Control Cable Trench By Brick Work, Edges By 40X5 Mm Ms Angle & Plastering With Trench Cover Having 40X5 Mm Ms Angle Edges As Per Standard Specifications. , Laying Of Control Cable For Both Transformers In Switchyard And Control Room Including Ferruling, Glanding And Connections With The Equipments , Erection Of Double Pole Structures Including Grounting (1:3:6 Cc Mixture), Foundation Plinth (1:2:4 Cc Mixture), Pole-Painting Along With Fixing Of Channels, Pin Insulators, Gi Pipe, Danger Board, Barbed Wire, Earth Wire, Spike Rod, Stay Set, Etc.As Per Approved Drawing And Standard Specification Of Uppcl/Resspo. , Laying Of 33 Kv/11 Kv/Lt Cable Including Mounting On Pole, Ms Structures, Etc. By Digging Of Trench At Standard Depth And Using Sand, Bricks, Etc As Per Approved Drawing And Standard Specification Of Uppcl/Resspo. , Erection, Mounting And Connection Of Heat Shrinkable Joints At Poles, Equipments, Structures, Etc. , Erection And Placement Of Fire Extinguisher, Sand Buckets With Stand, Earth Mat, Etc At Suitable Locations , Boring And Lowering Of Class-B 40 Mm Dia 20 Feet Long Gi Pipe And Connections With The Power Transformers(80 Feet Deep At 3 Points And Connection With Ms Round Bar Delta) And Other Equipments(60 Feet Deep) As Per Standard Practices Including All Necessary Fabrication Works And Construction Of 3 Earth Pits Each For Both Power Transformers , Levelling Of Switchyard After Back-Filling Of Soil And Using Stone Ballast For Top Surface Including Supply Of All Related Materials , Erection Of 33/11 Kv Ais S/S , Construction Of Power T/F Plinth Suitable For 10/12.5 Mva 33/11Kv T/F In Size Of 3.5 X 3.5 X 1.5 Mtr.By Digging Of Pit In Size Of 4.0 X 4.0 X 1.2 Mtr. Of Cc Work And At Bottom In Size Of 4.0 X 4.0 X .15 Mtr. With Ratio Of 1:3:6, Its Proper Ramming And Curing Thereafter Brick Work In Size Of 3.5 X 3.5 X 0.8 Mtr. With 1 : 4 Cc Sand Ratio, Thereafter Cc Work On Top In Size Of 3.5 X 3.5 X .25 Mtr. Thereafter Plastering All Around The Open Portion, Grouting Of Rail And M.S. Angle In Top Cc Work And Its Proper Curing. Reinforcement By Mesh Of Steel Tmt Bar Of Size 12Mm. , Erection, Testing And Commissioning Of 10/12.5 Mva, 33/11 Kv Power T/F Along With Radiators, Conservator Tank, Vent Pipe, Rtcc Panel In Control Room And All Other Accessories On Main Tank After Placement Of Rail Pole 3 M Long Including Erection Of Required Number Of Ct/Pt Junction Box And Oil Filling And All Other Related Work/Supply Required For Succesful Commissioning. , Erection, Testing And Commissioning Of 33 Kv Vcb And Any Other Auxillary Items Required For Commissioning Along With Supply If Required Includingearthing By Extending And Welding, Painting Ms Flat 50X6. , Erection, Testing And Commissioning Of 33 Kv Feeder/ Single Transformer Control Relay Panel And Any Other Auxillary Items Required For Commissioning Along With Supply If Required. , Erection, Testing And Commissioning Of 33 Kv Double Transformer Control Relay Panel And Any Other Auxillary Items Required For Commissioning Along With Supply If Required. , Erection, Testing And Commissioning Of 11 Kv Vcb(I/C,O/G And Bus Coupler) And Any Other Auxillary Items Required For Commissioning Along With Supply If Required. , Erection Of 24 V, 80Ah, Ni-Cd Sealed Type Battery Set And All Other Accessories Complete. , Erection Of Float-Cum-Boost Battery Charger (Smps Based ) With Full Wave, Full Control Rectification, 50Hz Input Voltage For Charging 24V, 80 Ah Battery Alongwith Dcdb, Connectors, Surge Protection Device, Etc. Complete And Connection With 24 V, 80Ah Battery Set And Single Phase Ac Input Supply. , Erection Of 415V Ac Distribution Board/Panel Of Sheet Steelenclosed Cubical With Surge Protection Device Floor Mounting Type For Catering Auxiliary Power Supply Of The Substation,Etc. Including Supply Of Wires And Any Other Materials Required. , Erection, Testing And Commissioning Of 63 Kva, 11 Kv/0.415 Kv Station Transformer Along With All Accessories Such As Do Fuse, Bushing Boots, Ht/Lt Side Connections From S/S Panel And Upto Ac Distribution Box(Excluding Laying), Etc. As Per Ts Along With Supply Of Copper L-Joints For Lt Bushing And Any Other Accessories Required. , Erection Of Switchyard Earthing Mat For Double Transformer And Related Switchyard Equipments Using Ms Round Bar Of 40 Mm Dia By Pegging And Driving It 50Cm Below Ground Level Including All Fabrication Work And Erection Of Required No. Of Delta And Connection Of Equipments With This Mat Using 75X8 Ms Strips. , Erection Of Bus Bar Gantry Using Rail Poles Icluding Grouting, Painting, Etc. For 2 Different 33 Kv Sources Having Provision Of Inter-Operability Using A Bus Isolaor Along With Erection Of Lower And Upper Bus Bar Using Panther Conductor Including Supply Of Pg Clamps,T-Connector, Disc Fittings For Panther, Etc. As Per Standard Specifications And Other Required Material , Erection Of Required Number Of Mounting Structures For Switchyard Euipments Such As Vcb, La, Isolator, Cable Support Structure, Neutral Structures, Post Insulator Structures, Ct, Pt Etc., Then Mounting Of Equipments Along With Grouting, Foundation Plinth, Painting Etc And Any Other Required Work As Per Standard Specifications, Approved Drawings, Uppcl Norms , Construction Of Control Cable Trench By Brick Work, Edges By 40X5 Mm Ms Angle & Plastering With Trench Cover Having 40X5 Mm Ms Angle Edges As Per Standard Specifications. , Laying Of Control Cable For Both Transformers In Switchyard And Control Room Including Ferruling, Glanding And Connections With The Equipments , Erection Of Double Pole Structures Including Grounting (1:3:6 Cc Mixture), Foundation Plinth (1:2:4 Cc Mixture), Pole-Painting Along With Fixing Of Channels, Pin Insulators, Gi Pipe, Danger Board, Barbed Wire, Earth Wire, Spike Rod, Stay Set, Etc.As Per Approved Drawing And Standard Specification Of Uppcl/Resspo. , Laying Of 33 Kv/11 Kv/Lt Cable Including Mounting On Pole, Ms Structures, Etc. By Digging Of Trench At Standard Depth And Using Sand, Bricks, Etc As Per Approved Drawing And Standard Specification Of Uppcl/Resspo. , Erection, Mounting And Connection Of Heat Shrinkable Joints At Poles, Equipments, Structures, Etc. , Erection And Placement Of Fire Extinguisher, Sand Buckets With Stand, Earth Mat, Etc At Suitable Locations , Boring And Lowering Of Class-B 40 Mm Dia 20 Feet Long Gi Pipe And Connections With The Power Transformers(80 Feet Deep At 3 Points And Connection With Ms Round Bar Delta) And Other Equipments(60 Feet Deep) As Per Standard Practices Including All Necessary Fabrication Works And Construction Of 3 Earth Pits Each For Both Power Transformers , Levelling Of Switchyard After Back-Filling Of Soil And Using Stone Ballast For Top Surface Including Supply Of All Related Materials , Capacity Augmentation Power Transformer , Dismantling Of Existing Power Transformer After Draining Out Radiator And Conservator Oil, Shifting From The Plinth And Transporation To Kesco Stores And Safely Place All Parts In Kesco Store In A Reusable Conditionincluding Any Civil/Fabrication Work Required For Removing Obstacles In Path Of Dismantling/Erection Of Power Transformers , Dismantling Of The Existing Small Sized Plinth To Make Space For Large Sized 10/12.5/20 Mva Power Transformer , Construction Of Power T/F Plinth Suitable For 10/12.5 Mva 33/11Kv T/F In Size Of 3.5 X 3.5 X 1.5 Mtr.By Digging Of Pit In Size Of 4.0 X 4.0 X 1.2 Mtr. Of Cc Work And At Bottom In Size Of 4.0 X 4.0 X .15 Mtr. With Ratio Of 1:3:6, Its Proper Ramming And Curing Thereafter Brick Work In Size Of 3.5 X 3.5 X 0.8 Mtr. With 1 : 4 Cc Sand Ratio, Thereafter Cc Work On Top In Size Of 3.5 X 3.5 X .25 Mtr. Thereafter Plastering All Around The Open Portion, Grouting Of Rail And M.S. Angle In Top Cc Work And Its Proper Curing. Reinforcement By Mesh Of Steel Tmt Bar Of Size 12Mm. , Construction Of Power T/F Plinth Suitable For 20 Mva 33/11Kv T/F In Size Of 4.0 X 4.0 X 2.0 Mtr.By Digging Of Pit In Size Of 4.5 X 4.5 X 1.5 Mtr. Of Cc Work And At Bottom In Size Of 4.5 X 4.5 X 0.30 Mtr. With Ratio Of 1:3:6, Its Proper Ramming And Curing Thereafter Brick Work In Size Of 4.0 X 4.0 X 1.0 Mtr. With 1 : 3 Cc Sand Ratio, Thereafter Cc Work On Top In Size Of 4.0 X 4.0 X .0.40 Mtr. Thereafter Plastering All Around The Open Portion, Grouting Of Rail And M.S. Angle In Top Cc Work And Its Proper Curing. Reinforcement By Mesh Of Steel Tmt Bar Of Size 16 Mm. , Erection, Testing And Commissioning Of 10/12.5 Mva, 33/11 Kv Power T/F Along With Radiators, Conservator Tank, Vent Pipe, Rtcc Panel In Control Room And All Other Accessories On Main Tank After Placement Of Rail Pole 3 M Long Including Erection Of Required Number Of Ct/Pt Junction Box And Oil Filling And All Other Related Work/Supply Required For Succesful Commissioning. , Erection, Testing And Commissioning Of 20 Mva, 33/11 Kv Power T/F Along With Radiators, Conservator Tank, Vent Pipe, Rtcc Panel In Control Room And All Other Accessories On Main Tank After Placement Of Rail Pole 3 M Long Including Erection Of Required Number Of Ct/Pt Junction Box And Oil Filling And All Other Related Work/Supply Required For Succesful Commissioning. , Erection Of Switchyard Earthing Mat For A Single Transformer And Related Switchyard Equipments Using Ms Round Bar Of 40 Mm Dia By Pegging And Driving It 50Cm Below Ground Level Including All Fabrication Work And Erection Of Required No. Of Delta And Connection Of Equipments With This Mat Using 75X8 Ms Strips. , Erection, Grouting And Painting Of Isolator Structure With 1:3:6 Cc 25 Mm Brick Ballast In Required Size In Proper Alignment And Making Plinth Of All Structure In 1:2:4 Cc Mix With 20 Mm Stone Grit, 15 Cm Ground Level To Smooth Finish And Its Proper Curing Including Cost Of Cement, Mounting Of Isolator And Connection With Earth Mat , Erection, Grouting And Painting Of Post Insulator/L.A./C.T/P.T Structure/Cable Support Structure With 1:3:6 Cc 25 Mm Brick Ballast In Required Size In Proper Alignment And Making Plinth Of All Structure In 1:2:4 Cc Mix With 20 Mm Stone Grit, 15 Cm Ground Level To Smooth Finish And Its Proper Curing Including Cost Of Cement, Mounting Of Insulator/L.A./C.T/P.T. And Connection With Earth Mat , Erection, Grouting And Painting Of Neutral Support Structure With 1:3:6 Cc 25 Mm Brick Ballast In Required Size In Proper Alignment And Making Plinth Of All Structure In 1:2:4 Cc Mix With 20 Mm Stone Grit, 15 Cm Ground Level To Smooth Finish And Its Proper Curing Including Cost Of Cement And Connection With Earth Mat , Erection, Testing And Commissioning Of 33 Kv Feeder/ Single Transformer Control Relay Panel And Any Other Auxillary Items Required For Commissioning Along With Supply If Required. , Erection, Testing And Commissioning Of 11 Kv Vcb(I/C Or O/G Or Bus Coupler Or Adapter Panel ) And Any Other Auxillary Items Required For Commissioning Along With Supply If Required. , Extension Of Main Bus Bar Gantry/ Erection Of Upper Bus Bar For Additional Power Transformer Including Required Grouting, Painting, Erection Of Lower Bus, Etc. And Connection With Earth Mat. , Construction Of Control Cable Trench By Brick Work, Edges By 40X5 Mm Ms Angle & Plastering With Trench Cover Having 40X5 Mm Ms Angle Edges As Per Standard Specifications. , Laying Of Control Cable For Single Transformer In Switchyard And Control Room Including Ferruling, Glanding And Connections With The Equipments , Laying Of 33 Kv/11 Kv/Lt Cable Including Mounting On Pole, Ms Structures, Etc. By Digging Of Trench At Standard Depth And Using Sand, Bricks, Etc As Per Approved Drawing And Standard Specification Of Uppcl/Resspo. , Erection, Mounting And Connection Of Heat Shrinkable Joints At Poles, Equipments, Structures, Etc. , Boring And Lowering Of Class-B 40 Mm Dia 20 Feet Long Gi Pipe And Connections With The Power Transformers(80 Feet Deep) And Connection With Ms Round Bar Delta, If Required For Neutral Earthing. , Boring And Lowering Of Class-B 40 Mm Dia 20 Feet Long Gi Pipe And Connections With The Switchyard/Control Room Equipments (60 Feet Deep). , Levelling Of Switchyard After Back-Filling Of Soil And Using Stone Ballast For Top Surface Including Supply Of All Related Materials , 11 Kv Overhead Line Works , Excavation Of Pole Pit (Of Depth 1/6Th Of Pole Length)Per Scope Of Work, Approved Drawings And Specifications: , 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 (Is 2713, Pt I, Ii, Iii 1980) And Bottom Galvanised As Per Is 2629 (1985) , 9.5 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 37 (Is 2713, Pt I, Ii, Iii 1980) And Bottom Galvanised As Per Is 2629 (1985) , Erection Of Following Types Of Poles(For All Types Of Single/Double/Tri/Four Pole Structures) For 11 Kv Overhead Line By Providing And Installing Danger Plate, Anti-Climbing Devices (Barbed Wire), Earthing Material (Spike Rod & 8Swg Gi Wire), Red Oxide & Aluminium Paint, Pole Numbering Including Cement Concrete Foundation Or Refilling By Bolders Using Cement Concreting Foundation 1 Part Cement, 3 Part Sand, 6 Part 40 Mm Size Stone Aggregate Chips (1:3:6)Or/And 200 Mm Average Size Bolders Mixed With Excavated Earth Etc. Along With 250 Mm Dia X 12 Inch Size Muffing Using Cement Concrete Of 1:2:4(1 Part Cement, 2 Part Coarse Sandand 4 Parts 20 Mm Aggregate Stone Chip)As Per Scope Of Work, Approved Drawings And Specifications: , 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 (Is 2713, Pt I, Ii, Iii 1980) And Bottom Galvanised As Per Is 2629 (1985) For Single Ckt Line , 9.5 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 37 (Is 2713, Pt I, Ii, Iii 1980) And Bottom Galvanised As Per Is 2629 (1985). , Erection Of Complete Stay Set With Gi Stay Wire (7X3.15 Mm Dia), Binding Of Stay Wire, By Providing Guy Stay Insulator (2 Nos.) And 0.2 Cmt Concreting 1 Part Cement, 3 Part Sand, 6 Part 40 Mm Size Stone Aggregate Chips (1:3:6) As Per Technical Specifications, Approved Drawings And Scope Of Works Including Digging Of Suitable Pit. , Erection, Testing & Commissioning Of Pre-Fabricated Galvanized Steel Items Like V Cross Arm, Top Clamp, Dc Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Etc Made Of Gs Channels, Gs Angle, Gs Flats Of Given Sizes For Over Head Structures And Gs Nuts, Bolts & Washersincluding Painting By Red Oxide & Aluminium Paint As Per Technical Specification, Approved Drawings And Scope Of Work. , Erection, Testing And Commissioning Of 11 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work Including Supply Of Suitable Winding, Any Other Material Required , 11 Kv Pin Insulator With Gi Pin , 11 Kv Disc Insulator(For Bare/Covered Conductor) 70Kn With Strain Hardware , Laying Out, Tensioning, Binding Of Conductor And Tightening Of Stays And Stringing, Testing And Commissioning Of Acsrconductor/Covered Conductor Of Following Sizes Including Jointing Sleeves, Helical Formed Fittings, Jumpering And By Providing & Erecting Pg Clamps Etc As Required As Per Approved Drawings, Scope Of Work And Technical Specifications. This Includes Double Circuit Line As Well Existing Single Circuit To Double Circuit As Well. , 6/4.72 Mm+7/1.57 Mm (100 Mm² Al. Area) - Acsr Dog Conductor , 11 Kv Covered Conductor Including Required Accessories , Dismantling Of Existing Pole,Overhead Line Conductor & Fittings And Depositing To Employer Store , Old Dog/Weasel Conductor With All Fittings , Old 11/9.5/9 Mtr Stp Pole , Strengthening Of Existing Damaged Pole By Providing And Welding 1.2Mtr Long 3 No Ms Angle 65*65*6Mm And Carrying Out Required Grouting And Pole Plinth Activities As Per Approved Drawing And Technical Specification. , Erection Of 8 Swg Gi Wire For Guarding By Providing Gi Nut, Bolts & Washers, Turn Buckle Etc , 11 Kv Ug Line Work , Excavation Of Additional Pole Pit (Of Depth 1/6Th Of Pole Length) As Per Scope Of Work, Approved Drawings And Specifications: , 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 (Is 2713, Pt I, Ii, Iii 1980)And Bottom Galvanised As Per Is 2629 (1985) , 9.5 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 37 (Is 2713, Pt I, Ii, Iii 1980) And Bottom Galvanised As Per Is 2629 (1985) , Erection Of Following Types Of Poles For 11 Kv Overhead Line By Providing And Installing Danger Plate, Anti-Climbing Devices (Barbed Wire), Earthing Material (Spike Rod And 8Swg Gi Wire), Red Oxide & Aluminium Paint, Pole Numbering Including Cement Concrete Foundation Or Refilling By Bolders Using Cement Concreting Foundation 1 Part Cement, 3 Part Sand, 6 Part 40 Mm Size Stone Aggregate Chips (1:3:6) Volume 0.5 Cub Mtr. Or/And 200 Mm Average Size Bolders Mixed With Excavated Earth Etc. Along With 250 Mm Dia X 12 Inch Size Muffing Using Cement Concrete Of 1:2:4(1 Part Cement, 2 Part Coarse Sandand 4 Parts 20 Mm Aggregate Stone Chip)As Per Scope Of Work, Approved Drawings And Specifications: , 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 (Is 2713, Pt I, Ii, Iii 1980) And Bottom Galvanised As Per Is 2629 (1985). , 9.5 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 37 (Is 2713, Pt I, Ii, Iii 1980) And Bottom Galvanised As Per Is 2629 (1985) , Erection Of Complete Stay Set With Gi Stay Wire (7X3.15 Mm Dia), Binding Of Stay Wire, By Providing Guy Stay Insulator (2 Nos.) And 0.2 Cmt Concreting 1 Part Cement, 3 Part Sand, 6 Part 40 Mm Size Stone Aggregate Chips (1:3:6) As Per Technical Specifications, Approved Drawings And Scope Of Works Including Digging. , Erection, Testing And Commissioning Of 11 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. , 11 Kv Pin Insulator With Gi Pin , Erection, Testing & Commissioning Of Pre-Fabricated Galvanized Steel Items Like V Cross Arm, Top Clamp, Dc Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Etc Made Of Gs Channels, Gs Angle, Gs Flats Of Given Sizes For Over Head Structures And Gs Nuts, Bolts & Washersincluding Painting By Red Oxide & Aluminium Paint As Per Technical Specification, Approved Drawings And Scope Of Work. , Laying Of 11Kv Cable Through Hdd Method Including Digging Of Pit (Without Pipe) , Laying Of 11 Kv Cable In Air(Pole To Pole) , Laying Of 11Kv Cable Through Hdd Method Including Digging Of Pit (With G.I. Pipe) , Laying Of 11Kv Cable Through Molling Method Including Digging Of Pit , Digging Of Trench .3 Mtr Wide 1.1 Mtr To 1.5 Mtr Deep For Laying Of Pipe And Cable , Normal Soil , Soft Rock/ Kharanja , Hard Rock / Metallic Road/ Rcc , Laying Of Gi Pipe 6 Dia In Above Digged Trench And For Raising Cable On Double Pole/Structure , Laying Of 11 Kv Cable Through Above Pipe , Laying Of Cable In Above Digged Trench And Also Mounting Upto Line By Using Bricks/ Sand &Stone Pad As Per Rec Norms , Making Andmounting Of Heat Shrinkable Jointing Kit For 11 Kvxlpe Cable , Digging Suitable Pit And Making Straight Through Joint 11 Kv Xlpe Cable , Making Of Straight Through Joint , Laying Of 11 Kv Cable With Channel/Pipe Support From Bottom Upto Pole Top , Distribution Transformers Works , Excavation Of Pole Pit (Of Depth 1/6Th Of Pole Length)Per Scope Of Work, Approved Drawings And Specifications: , 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 (Is 2713, Pt I, Ii, Iii 1980) And Bottom Galvanised As Per Is 2629 (1985) , 4 Mtr Long Joist Girdar Pole (1.5 Mtr Below Ground Level) , Erection Of Following Types Of Poles For 11 Kv Overhead Line By Providing And Installing Danger Plate, Anti-Climbing Devices (Barbed Wire), Earthing Material (Spike Rod & 8Swg Gi Wire), Red Oxide & Aluminium Paint, Pole Numbering Including Cement Concrete Foundation Or Refilling By Bolders Using Cement Concreting Foundation 1 Part Cement, 3 Part Sand, 6 Part 40 Mm Size Stone Aggregate Chips (1:3:6) Volumeor/And 200 Mm Average Size Bolders Mixed With Excavated Earth Etc. Along With 250 Mm Dia X 12 Inch Size Muffing Using Cement Concrete Of 1:2:4(1 Part Cement, 2 Part Coarse Sandand 4 Parts 20 Mm Aggregate Stone Chip)As Per Scope Of Work, Approved Drawings And Specifications: , Erection Of 4 Mtrjoist Gurader Pole ( 1.5 Mtr Below Ground Level) , Erection Of Double Pole Structures Including Grouting (1:3:6 Cc Mixture), Foundation Plinth (1:2:4 Cc Mixture), Pole-Painting Along With Fixing Of Channels, Pin Insulators With Pin,Disc Insulator Along With Fitting, Gi Pipe, Danger Board, Barbed Wire, Earth Wire, Spike Rod, Etc.As Per Approved Drawing And Standard Specification Of Uppcl/Resspo. , Erection Of Double Pole Structure With Existing Single Pole Including Grouting (1:3:6 Cc Mixture), Foundation Plinth (1:2:4 Cc Mixture), Pole-Painting Along With Fixing Of Channels, Pin Insulators, Disc Insulators, Gi Pipe, Danger Board, Barbed Wire, Earth Wire, Spike Rod, Etc.As Per Approved Drawing And Standard Specification Of Uppcl/Resspo. , Erection, Testing & Commissioning Of Earthing By Inserting Gi Earthing Spike 2540 Mm Long Made Of 20Mm Solid Rod As Per Approved Drawings, Scope Of Work And Technical Specifications , Erection Of 8 Swg Gi Wire For Earthing And Guarding By Providing Gi Nut, Bolts & Washers, Turn Buckle Etc , Erection Of Complete Stay Set With Gi Stay Wire (7X3.15 Mm Dia), Binding Of Stay Wire, By Providing Guy Stay Insulator (2 Nos.) And 0.2 Cmt Concreting 1 Part Cement, 3 Part Sand, 6 Part 40 Mm Size Stone Aggregate Chips (1:3:6) As Per Technical Specifications, Approved Drawings And Scope Of Works Including Digging Of Suitable Pit. , Construction Of T/F Plinth, Suitable For Mounting Of Distribution Transformer Size Of The Plinth Will Be 1.2X1.2X1.2 Meter Solid With Brick Work. 75 Mm Thick C.C. In Ratio 1:3:6 With Cement, Coarse Sand And Brick Ballast Laid On The Base And 75 Mm Thick Done On All The Exposed Sides To The Plinth. , Erection And Fabrication Of T/F Fencingof Frame Size 3X2.4 Mtr. With Gate And Latch(Size Of Fencing May Vary As Per Site Conditions) Including Cost Of M.S. Angle Size 40X40x5 And M.S. Flat Size 50X6, Fixing Of Welded Steel Wire Fabric On Steel Frames By Welding Of 10 Swg Wire Fabric, Including Painting Of Two Coats Of Paint On Iron Based Surfaces With Ready Mixed Paint To Give Bus Green Shade Including Cleaning Of Oil And Dust. Additional Ms Strips 40X5 Sqmm Having Height Same As That Of Fencing To Be Placed Vertically On The Steel Wire Fabric At A Distance Of 0.5 M From One Another For Additional Reinforcement And Grouting Of Ms Angle With 1:3:6 Ratio (Capable Of Bearing All Load Of Fencing) , Erection And Fabrication Of T/F Fencingof Frame Size 3X2.4 Mtr. With Gate And Latch(Size Of Fencing May Vary As Per Site Conditions) Including Cost Of M.S. Angle Size 40X40x5 And M.S. Flat Size 50X6 Including Painting Of Two Coats Of Paint On Iron Based Surfaces With Ready Mixed Paint To Give Bus Green Shade Including Cleaning Of Oil And Dust. Additional Ms Strips 40X5 Sqmm Having Height Same As That Of Fencing To Be Placed Vertically On The Steel Wire Fabric At A Distance Of 75 Mm From One Another For Additional Reinforcement Including Of Grouting Of Ms Angle With 1:3:6 Ratio (Capable Of Bearing All Load Of Fencing) , Erection Of Lt Circuit 500A/500V On Pole With Proper Fitting Clamping And Connection With Transformer Using Single Core/Three Core Cable. , Erection Of Do Fuse Set On Double Pole Structure Including Required Fabrication Of Ms Items. , Laying Of 11 Kv Cable Pole To Polewith Proper Clamping And Sagging On Pole. , Erection Of 250/400 Kva Distribution Transformer Including Proper Connection Of Ht, Lt Side With Al Lug , L Connector. , Making Andmounting Of Heat Shrinkable Jointing Kit For 11 Kv 3X70/185 Sqmm Xlpe Cable , Erection Of Bushing Boot On 11 Kv Side Of Transformer , 40 Feetdeep Bore Separate Earthing ( 1 Neutral + 1 Body ) Including Laying And Connecting Of Gi Strip With Transformer Body/Neutral With The Gi Pipe , Dismantling Of 63/100/160/250 Kva Distribuiton Transformer Including Opening Of Existing Ht/Lt/Neutralconnection And Depositing To Employer Store With Proper Safety. , Erection And Commissioning Of Lt Acb , Making Suitable Foundation Plinth (1:2:4 Cc Mixture), Connection With Dt And Lt Circuit Using Al Lug And Single Core Cable With Crimping Tool And Other Required Accessorries. , Earthing Of Lt Acb , 40 Feet Deep Bore Gi Pipe Earthing Including And Connection With Acb By Using Al Lug, Proper Tightening With Nut And Boult. , Compact S/S Works , Construction Of T/F Plinth Suitable For Mounting Of Css Size And Housing Of 11 Kv And Lt Cable , 4 No , 40 Feet Deep Bore Gi Pipe Earthing Including And Connection With Dt And Rmu, And Substation By Using Al Lug, Proper Tightening With Nut And Boult Complete In All Respect , Erection And Commissioning Of 11/0.4 Kv Compact Packaged Substation Incuding Conection On Ht/Lt Side With Proper Tightening Of Connections By Using Lugs And Other Sundary Items. , Digging Of Trench .3 Mtr Wide 1.1 Mtr To 1.5 Mtr Deep For Laying Of Pipe And Cable , Normal Soil , Soft Rock/ Kharanja , Hard Rock / Metallic Road/ Rcc , Laying Of 11 Kv/ Lt Cable In Above Digged Trench And Also Mounting Upto Line By Using Bricks/ Sand &Stone Pad As Per Rec Norms , Making Andmounting Of Heat Shrinkable Jointing Kit For 11 Kv 3X70 Sqmm Xlpe Cable , 33 Kv Over Head Line Work , Excavation Of Pole Pit (Of Depth 1/6Th Of Pole Length)Per Scope Of Work, Approved Drawings And Specifications: , 13 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 (Is 2713, Pt I, Ii, Iii 1980) Andas Peris 2629 (1985) , 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 (Is 2713, Pt I, Ii, Iii 1980) Andas Peris 2629 (1985) , Erection Of Following Types Of Poles(Including Single/Double Triple/Four Pole Structures)For 33 Kv Overhead Line By Providing And Installing Danger Plate, Anti-Climbing Devices (Barbed Wire), Earthing Material ( Spike Rod & 8Swg Gi Wire), Red Oxide & Aluminium Paint, Pole Numbering Including Cement Concrete Foundation Or Refilling By Bolders Using Cement Concreting Foundation 1 Part Cement, 3 Part Sand, 6 Part 40 Mm Size Stone Aggregate Chips (1:3:6) And 200 Mm Average Size Bolders Mixed With Excavated Earth Etc. Along With 250 Mm Dia X 12 Inch Size Muffing Using Cement Concrete Of 1:2:4(1 Part Cement, 2 Part Coarse Sandand 4 Parts 20 Mm Aggregate Stone Chip)As Per Scope Of Work, Approved Drawings And Specifications: , 13 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 (Is 2713, Pt I, Ii, Iii 1980) And Bottom Galvanised As Per Is 2629 (1985) , 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 (Is 2713, Pt I, Ii, Iii 1980) And Bottom Galvanised As Per Is 2629 (1985). , Conversion Of Existing Single Ckt Line To Double Circuit Line. , Erection, Testing & Commissioning Of Pre-Fabricated Galvanized Steel Items Like V Cross Arm, Top Clamp, Dc Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Etc Made Of Gs Channels, Gs Angle, Gs Flats Of Given Sizes For Over Head Structures And Gs Nuts, Bolts & Washersincluding Painting By Red Oxide & Aluminium Paint As Per Technical Specification, Approved Drawings And Scope Of Work. , Erection Of 8 Swg Gi Wire For Guarding By Providing Gi Nut, Bolts & Washers, Turn Buckle Etc , Erection Of Complete Stay Set With Gi Stay Wire (7X3.15 Mm Dia), Binding Of Stay Wire, By Providing Guy Stay Insulator (2 Nos.) And 0.2 Cmt Concreting 1 Part Cement, 3 Part Sand, 6 Part 40 Mm Size Stone Aggregate Chips (1:3:6) As Per Technical Specifications, Approved Drawings And Scope Of Works Including Digging Of Suitable Pit. , Erection, Testing And Commissioning Of 33 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. , 33 Kv Pin Insulator With Gi Pin , 11 Kv Disc Insulator 70Kn , 11 Kv Disc Fitting , Laying Out, Tensioning, Binding Of Conductorand Stringing, Testing And Commissioning Of Acsrconductor/Covered Conductor Of Following Sizes Including Jointing Sleeves, Helical Formed Fittings, Jumpering And By Providing & Erecting Pg Clamps Etc As Required As Per Approved Drawings, Scope Of Work And Technical Specifications , 6/4.72 Mm+7/1.57 Mm (100 Mm² Al. Area) - Acsr Dog Conductor , 33 Kv Covered Conductor Including Required Accessories , Dismantling Of Existing Pole ,Overhead Line Conductor & Fittings And Depositing To Employer Store , Old Weasel/Dog/Panther Conductor , 13/11 Mtr Stp Pole , Strengthening Of Existing Damaged Pole By Providing And Welding 1.2Mtr Long 3 No Ms Angle 65*65*6Mm And Carrying Out Required Grouting And Pole Plinth Activities As Per Approved Drawing And Technical Specification. , Construction Of New 33 Kv Ug Lines , Excavation Of Pole Pit (Of Depth 1/6Th Of Pole Length)Per Scope Of Work, Approved Drawings And Specifications: , 13 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 (Is 2713, Pt I, Ii, Iii 1980) And Bottom Galvanised As Per Is 2629 (1985) , 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 (Is 2713, Pt I, Ii, Iii 1980) And Bottom Galvanised As Per Is 2629 (1985) , Erection Of Following Types Of Poles(Including Single/Double Triple/Four Pole Structures)For 33 Kv Overhead Line By Providing And Installing Danger Plate, Anti-Climbing Devices (Barbed Wire), Earthing Material ( Spike Rod & 8Swg Gi Wire), Red Oxide & Aluminium Paint, Pole Numbering Including Cement Concrete Foundation Or Refilling By Bolders Using Cement Concreting Foundation 1 Part Cement, 3 Part Sand, 6 Part 40 Mm Size Stone Aggregate Chips (1:3:6) And 200 Mm Average Size Bolders Mixed With Excavated Earth Etc. Along With 250 Mm Dia X 12 Inch Size Muffing Using Cement Concrete Of 1:2:4(1 Part Cement, 2 Part Coarse Sandand 4 Parts 20 Mm Aggregate Stone Chip)As Per Scope Of Work, Approved Drawings And Specifications: , 13 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 (Is 2713, Pt I, Ii, Iii 1980)And Bottom Galvanised As Per Is 2629 (1985). , 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 (Is 2713, Pt I, Ii, Iii 1980) And Bottom Galvanised As Per Is 2629 (1985) , Erection Of Complete Stay Set With Gi Stay Wire (7X3.15 Mm Dia), Binding Of Stay Wire, By Providing Guy Stay Insulator (2 Nos.) And 0.2 Cmt Concreting 1 Part Cement, 3 Part Sand, 6 Part 40 Mm Size Stone Aggregate Chips (1:3:6) As Per Technical Specifications, Approved Drawings And Scope Of Works Including Digging. , Erection, Testing And Commissioning Of 33 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. , 33 Kv Pin Insulator With Gi Pin , 11 Kv Disc Insulator 70Kn , 11 Kv Disc Fitting , Erection, Testing & Commissioning Of Pre-Fabricated Galvanized Steel Items Like V Cross Arm, Top Clamp, Dc Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Etc Made Of Gs Channels, Gs Angle, Gs Flats Of Given Sizes For Over Head Structures And Gs Nuts, Bolts & Washersincluding Painting By Red Oxide & Aluminium Paint As Per Technical Specification, Approved Drawings And Scope Of Work. , Laying Of 33Kv Cable Through Hdd Method Including Digging Of Pit (Without Pipe) , Laying Of 33Kv Cable Through Hdd Method Including Digging Of Pit (With G.I. Pipe) , Laying Of 33 Kv In Air(Pole To Pole) , Laying Of 33 Kv Cable Through Molling Method Including Digging Of Pit , Digging Of Trench .3 Mtr Wide 1.1 Mtr To 1.5 Mtr Deep For Laying Of Pipe And Cable , Normal Soil , Soft Rock/ Kharanja , Hard Rock / Metallic Road/ Rcc , Laying Of Gi Pipe 6 Dia In Above Digged Trench And For Raising Cable On Double Pole/Structure , Laying Of 33 Kv 3X300/400 Sqmm Cable Through Above Pipe , Laying Of Cable In Above Digged Trench And Also Mounting Upto Line By Using Bricks/ Sand &Stone Pad As Per Rec Norms , Laying Of 33 Kv Cable Upto Pole , Making Andmounting Of Heat Shrinkable Jointing Kit For 33 Kv 3X300/400 Sqmm Xlpe Cable , Digging Suitable Pit And Making Straight Through Joint 33 Kv 3X300/400 Sqmm , Making Of 33 Kv Straight Through Joint , 33 Kv Line On Lattice Pole , Erection Of Lattice Ms Structure Tower 16 M Height Including, Suitable 33 Kv Brackets With Fixable Spacers Of Adequate Insulating Materials , Other Minor Accessories Required, Polymeric Pin And Disc Insulators Including Grouting (1:1.5:3 Cc Mixture Min 2 Cubicmtr ), Foundation Plinth (1:2:4 Cc Mixture), 40 Feet Deep Bore Earthing , Laying Of Insulated Covered Conductor On M+4 Tower With Proper Sagging, Including Erection Of All Required Accessorries , 33 Kv Mid Line Isolator , Erection Of 33 Kv Isolator With Structure Including Grouting Of Ms Structure (1:3:6 Cc Mixture ), Fabrication,Painting And Other Work Required For Erection. , Erection/ Fixing Of 33 Kv Fuse Set With Structure Includingfabrication And Other Work Required For Erection. , Excavation Of Pole Pit (Of Depth 1/6Th Of Pole Length)Per Scope Of Work, Approved Drawings And Specifications: , 13 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 (Is 2713, Pt I, Ii, Iii 1980) And Bottom Galvanised As Per Is 2629 (1985) , Erection Of Following Types Of Poles(Including Single/Double Triple/Four Pole Structures)For 33 Kv Overhead Line By Providing And Installing Danger Plate, Anti-Climbing Devices (Barbed Wire), Earthing Material ( Spike Rod & 8Swg Gi Wire), Red Oxide & Aluminium Paint, Pole Numbering Including Cement Concrete Foundation Or Refilling By Bolders Using Cement Concreting Foundation 1 Part Cement, 3 Part Sand, 6 Part 40 Mm Size Stone Aggregate Chips (1:3:6) And 200 Mm Average Size Bolders Mixed With Excavated Earth Etc. Along With 250 Mm Dia X 12 Inch Size Muffing Using Cement Concrete Of 1:2:4(1 Part Cement, 2 Part Coarse Sandand 4 Parts 20 Mm Aggregate Stone Chip)As Per Scope Of Work, Approved Drawings And Specifications: , 13 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 (Is 2713, Pt I, Ii, Iii 1980) Andas Peris 2629 (1985) And Bottom Galvanised As Per Is 2629 (1985) , Erection, Testing And Commissioning Of 33 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. , 33 Kv Pin Insulator With Gi Pin , 11 Kv Disc Insulator 70Kn , 11 Kv Disc Fitting , Earthing Arrangement As Per Technical Specificatons,Approved Drawings And Scope Of Work. , Earthing With 40 Feet Deep Bore Gi Pipe Earthing Including Connection ,Proper Tightening With Nut And Boult. , Laying Of Single Core33 Kv ,1X400 Sqmm Cable Pole To Polewith Proper Clamping And Sagging On Pole. , 33/11 Kv S/S Switchgear , Erection, Testing And Commissioning Of 33 Kvindoor Vcb Incommer/Outgoing /Bus Coupler/ With Crp And Any Other Auxillary Items Required For Commissioning Along With Supply If Required Including Dissconneting And Reconnecting Of Existing Earthing By Extending And Welding, Painting Ms Flat 50X6. , Dismantling Of 33 Kv Vcb Including All Required Activity And Depositing Of Material At Employer Store. , Dismantling Of 33 Kv Crp Including All Required Activity And Depositing Of Materials At Employer Store. , Erection, Testing And Commissioning Of 33 Kv Feeder/ Single Transformer Control Relay Panel And Any Other Auxillary Items Required For Commissioning Along With Supply If Required Including Dissconneting And Reconnecting Of Existing Earthing By Extending And Welding, Painting Ms Flat 50X6. , Erection, Testing And Commissioning Of 33 Kv Double Transformer Control Relay Panel And Any Other Auxillary Items Required For Commissioning Along With Supply If Required Including Dissconneting And Reconnecting Of Existing Earthing By Extending And Welding, Painting Ms Flat 50X6. , Erection, Testing And Commissioning Of 33 Kv Vcb And Any Other Auxillary Items Required For Commissioning Along With Supply If Required Including Dissconneting And Reconnecting Of Existing Earthing By Extending And Welding, Painting Ms Flat 50X6. , Erection, Testing And Commissioning Of 11 Kv Vcb(I/C,O/G And Bus Coupler) And Any Other Auxillary Items Required For Commissioning Along With Supply If Required Including Dissconneting And Reconnecting Of Existing Earthingby Extending And Welding, Painting Ms Flat 50X6. , Erection, Testing And Commissioning Of 11 Kv Adapter Panel , Dismantling Of 11 Kv Vcb Including All Required Activity And Depositing Of Employer Store. , Erection Of 24 V, 80Ah, Ni-Cd Sealed Type Battery Set And All Other Accessories Complete. , Erection Of Float-Cum-Boost Battery Charger (Smps Based ) With Full Wave, Full Control Rectification, 50Hz Input Voltage For Charging 24V, 80 Ah Battery , Connectors, Surge Protection Device, Etc. Complete And Connection With 24 V, 80Ah Battery Set And Single Phase Ac Input Supply. , Erection Of 415V Ac Distribution Board/Panelincluding Supply Of Wires And Any Other Materials Required. , Erection Of Dc Distribution Board/Panel Including Supply Of Wires And Any Other Materials Required. , Erection And Commissioning Of Newly Erected Ct Along With Connection To Marshelling Box,Connection With Earth Strip And Other Activity Required For Successful Commissioning , Dismantling Of Existing Ct And Deposit Of Material At Employer Store. , Erection And Commissioning Of Newly Erected Pt Along With Connection To Marshelling Box, Connection With Earth Strip And Other Activity Required For Successful Commissioning , Dismantling Of Existing Pt And Deposit Of Material At Employer Store. , Erection Of Lightening Arrestor Including Connection With Earth Strip , Dismantling Of Non-Function La And Depsoit Of Material In Kesco Store , Laying Of Control Cable For In Switchyard And Control Room Including Ferruling, Glanding And Connections With The Equipments , Laying Of 11 Kv Cable Including Mounting On Pole, Ms Structures, Etc. By Digging Of Trench At Standard Depth And Using Sand, Bricks, Etc As Per Approved Drawing And Standard Specification Of Uppcl/Resspo. , Erection, Mounting And Connection Of Heat Shrinkable Joints At Poles, Equipments, Structures, Etc. , Lt Line Work Aerial Bunch Cable , Excavation Of Pole Pit (Of Depth 1/6Th Of Pole Length)Per Scope Of Work, Approved Drawings And Specifications: , 9 M Long Pcc Pole , Erection Of Pccpoles Along With Stone Padfor Lt Overhead Line By Providing And Installing Danger Plate, Anti-Climbing Devices (Barbed Wire),Pole Numbering Including Cement Concrete Foundation Or Refilling By Bolders Using Cement Concreting Foundation 1 Part Cement, 3 Part Sand, 6 Part 40 Mm Size Stone Aggregate Chips (1:3:6) As Per Scope Of Work, Approved Drawings And Specifications: , Erection Of Galvanized Stay Set With 50X8 Mm Stay Clamp, Stay Guy Insulator, Nut Bolts, 2 Nos Turn Buckles , 1.8 M Long, 16 Mm Diamater Solid Gs Stay Rod And 7/3.15 Mm Dia Gi Stranded Wire Etc As Required By Providing 0.2 Cum Cement Concrete As Per Approved Drawing, Techhnical Specification And Scope Of Work Including Digging Of Suitable Pit. , Erection, Testing And Commissioning Of New Aerial Bunched Xlpe Cable, Tension Clamps For Dead End, Suspension Clamps, Clamps For Neutral,Neutral Bare Connector, Piercing Connectors Type-I & Type-Ii 16 Mm Dia Ms Nuts And Bolts, Pole Clamps, Spring Loaded Bus Bar Suitable For Single Phased And Three Phase Systems Etc. As Required As Per Technicla Specification, Approved Drawing And Scope Of Work. , Erection Of Aerial Bunched Xlpecable 3X120+1X95+1X16 Sqmm With All Assecessiories. , Erection Of Aerial Bunched Xlpecable 3X150+1X125+1X16 Sqmm With All Assecessiories. , Erection & Commissioning Of Single Phase Crca Ms Deep Drawn Distribution Box With Clamps With 1X25 Sqmm Xlpe Cable ,Lug And All Accessories. , Erection & Commissioning Of Three Phase Crca Ms Deep Drawn Distribution Box Ith Clamps With 1X25 Sqmm Xlpe Cable ,Lug And All Accessories. , Erection & Commissioning Of Single Phase Smc Distribution Box With Clampsith Clamps With 1X25 Sqmm Xlpe Cable ,Lug And All Accessories. , Erection& Commissioningof Three Phase Smc Distribution Box Ith Clamps With 1X25 Sqmm Xlpe Cable ,Lug And All Accessories. , Erection, Testing & Commissioning Of Earthing By Inserting Gi Earthing Spike 2540 Mm Long Made Of 20Mm Solid Rod As Per Approved Drawings, Scope Of Work And Technical Specifications , Erection Of 8 Swg G.I. Wire For Earthing , Shifting Of Existing Consumer Connection To Newly Erected Ab Cable Line/Dog Conductor Line , Single Phase Connection , Three Phase Connection , Lt Line Work With Acsr Dog Conductor , Excavation Of Additional Pole Pit (Of Depth 1/6Th Of Pole Length) In Soft Rock/ Mettalic Road/ Rcc / Kharanjaas Per Scope Of Work, Approved Drawings And Specifications: , 9.5 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 37 (Is 2713, Pt I, Ii, Iii 1980) And Bottom Galvanized As Peris 2629 (1985) , Erection Of Following Types Of Poles For Lt Overhead Line By Providing And Installingdanger Plate Anti Climbing Devices (Barbed Wire), Red Oxide & Aluminium Paint Including Cement Concrete Foundation Or Refilling By Bolders Using Cement Concreting Foundation 1 Part Cement, 3 Part Sand, 6 Part 40 Mm Size Stone Aggregate Chips (1:3:6) Volume 0.5 Cub Mtr. Or/And 200 Mm Average Size Bolders Mixed With Excavated Earth Etc. Along With 250 Mm Dia X 12 Inch Size Muffing Using Cement Concrete Of 1:2:4(1 Part Cement, 2 Part Coarse Sandand 4 Parts 20 Mm Aggregate Stone Chip)As Per Scope Of Work, Approved Drawings And Specifications. , 9.5 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 37 (Is 2713, Pt I, Ii, Iii 1980) And Bottom Galvanized As Peris 2629 (1985) , Erection, Testing & Commissioning Of Pre-Fabricated Galvanized Steel Items Like Lt Bracket,Clamp,Bracket, Clamps,Gs Nuts, Bolts & Washersincludingas Per Technical Specification, Approved Drawings And Scope Of Work For Pcc Pole , Erection, Testing & Commissioning Of Earthing By Inserting Gi Earthing Spike 2540 Mm Long Made Of 20Mm Solid Rod As Per Approved Drawings, Scope Of Work And Technical Specifications , Erection Of 8 Swg G.I. Wire For Earthing , Erection Of Complete Stay Set With Gi Stay Wire (7X3.15 Mm Dia), Binding Of Stay Wire, By Providing Guy Stay Insulator (2 Nos.) And 0.2 Cmt Concreting 1 Part Cement, 3 Part Sand, 6 Part 40 Mm Size Stone Aggregate Chips (1:3:6) As Per Technical Specifications, Approved Drawings And Scope Of Works Including Digging Of Suitable Pit. , Erection, Testing And Commissioning Of Lt Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. , Pin Insulator With Gi Pin/ Shackle Insulator With Strip , Laying Out, Tensioning, Binding Of Conductor And Tightening Of Stays And Stringing, Testing And Commissioning Of Acsrconductor/Covered Conductor Of Following Sizes Including Jointing Sleeves, Helical Formed Fittings, Jumpering And By Providing & Erecting Pg Clamps Etc As Required As Per Approved Drawings, Scope Of Work And Technical Specifications , 6/4.72 Mm+7/1.57 Mm (100 Mm² Al. Area) - Acsr Dog Conductor , Strengthening Of Existing Damaged Pole By Providing And Welding 1.2Mtr Long 3 No Ms Angle 65*65*6Mm And Carrying Out Required Grouting And Pole Plinth Activities As Per Approved Drawing And Technical Specification. , Line Switching And Isolation , Erection And Commissioning Of 33 Kv Fpi Including Required Accessories , Erection And Commissioning Of 11 Kv Fpi Including Required Accessories , Erection, Fabrication & Commissioning Of Pre-Fabricated Channels, Back Clamp, Etc Made Of Gs Channels, Gs Angle, Gs Flats Of Given Sizes For Over Head Structures And Gs Nuts, Bolts & Washers As Per Technical Specification, Approved Drawings And Scope Of Work. , Erection And Commissioning Of Gang Operated Devices On Pole Including All Fitting, Making Connection With Existing Line Using Jumper Of Insulated Dog, And Al Lug Etc And Other Required Work For Commissioning As Per Standard Specifications, Approved Drawings, Uppcl Norms , Erection And Commissioning Of Dissconnecting Link On Pole Including All Fitting, Making Connection With Existing Line Using Jumpher, Insulated Dog, And Al Lug Etc And Other Required Work For Commissioning As Per Standard Specifications, Approved Drawings, Uppcl Norms , Mounting Of Horizontal Isolator On The Structure Along With Grouting, Foundation Plinth, Painting, Earthing, Making Connection With 11 Kv Line Etc And Any Other Required Work As Per Standard Specifications, Approved Drawings, Uppcl Norms , Conversion Of Exisiting Lt Bare Conductor Line Into Lt Under Ground Network. , Erectionof Cable End Termination Using Total Double Compression Brassglands And Crimping Type Aluminum Thimbles , Digging Ofpits After Due Survey With The Help Of Utility Detector Of Existing Electrical/Telephonic Cable/And Other Utilites Of Public Utilites Departmentand Laying And Commissioning Of Cables Of Size 3.5 Cx300/240/120/70 Sq Mm. Xlpe By Manual Drill (By Making Moles) , Digging Of Pits After Due Survey With The Help Of Utility Detector Of Existing Electrical/Telephonic Cable/And Other Utilites Of Public Utilites Departmentand Laying And Commissioning Of Cables Of Size 3.5 Cx300/240/120/70 Sq Mm. Xlpe Through Hdd Method With The Help Of Hdd Machine , Digging Of Trench By Open Trench Method After Due Survey With The Help Of Utility Dectector Of Existing /Telephonic Cable And Other Utilites Of Public Utilites Departmentand Laying And Commissioning Of Cables Of Size3.5 Cx300/240/120/70 Sq Mm. Xlpe , Back Filling And Conversion Of The Road Into Motorable Status Again , Laying Of Hdpe Pipe Of Various Sizes By Horizontal Drilling For Under Ground Piping (Trenchless) For Above Cable At Road Crossing Min. Depth Of Pipe Shall Be 1.5 Mtr. Below Surface 110 Mm. Dia. , Laying Of Gi Pipe Of 50Mm Dia (External Area) , Laying Of Gi Pipe Of 40Mm Dia (External Area) , Laying Of Pvc Pipe Heavy Gauge 40 Mm Dia (Under Ground Area) , Erection Of G.I. Strip/M.S. Strip Of Size 25X3/50X6 Sqmm Connectingpannel With Spike Rod/Deep Bore Earthing Arrangement Including Required Bolting/Welding , Dismantling Of Existing Lt Overhead Line Including Stp Poles, Bare Conductor/A.B. Cable, Pole Accessories And Transportation Of Dismantled Materials To Kesco Store. , Laying Of Aluminum Armored Xlpes Cables Size 2X6 Sq Mm. Upto Consumer Meter , Laying Of Aluminum Armored Xlpes Cables Size 2X10 Sq Mm. Upto Consumer Meter , Laying Of Aluminum Armored Xlpes Cables Size 2X16 Sq Mm. Upto Street Light Point , Laying Of Aluminum Armored Xlpes Cables Size 4X16 Sq Mm. Upto Consumer Meter , Laying Of Aluminum Armored Xlpes Cables Size 4X25sq Mm. Upto Consumer Meter , Installation, Testing & Commissioning Of Outdoor Type A-2/A-3/A-4 Lt Distribution Box Including All Civil Work Required As Per Specification And Approve Drawings , Installation, Testing & Commissioning Of Outdoor Type B-1/B-2/B-3 Lt Feeder Pillar Panelincluding All Civil Work Required As Per Specification And Approve Drawings , Installation, Testing & Commissioning Of Lockable Distribution Box Along With Bar Lock Of Size 450X450 Mm Including Suitable Foundation With Bus Bar 140 Amp. Tpn To Feed Up To 10 Houses (Type C)Mounting With G.I. Angle Of Size 65X65x6mm , Erection, Testing And Commissioning Of Street Light Junction Box And Connection Of Street Lamps Of Nagar Nigam , Boring Upto 40 Feet And Erection Of Gi Pipe 40Mm Dia B-Class 40 Feet Long For Connection With Type-A/B Fsp Panel Along With Supply Of G.I. Strip Of Size 50X6 Sqmm , Erection, Testing & Commissioning Of Earthing By Inserting Gi Earthing Spike 2540 Mm Long Made Of 20Mm Solid Rod As Per Approved Drawings, Scope Of Work And Technical Specifications , Preparation And Submission Of 2 Sets Of Detailed Printed Drawing/Auto Cad Drawing / Pdf (Along With Digital Copy) Of L.T. Network Of Each D.T. Depicting Location Of L.T. Cables And All Panels(Type-A,B And C) And Separate List For All Connections On Type C Panels In Excel Format , Pole Insulation , Supply And Erection Of Insulation Material On 33 Kv/ 11 Kv/ Lt Pole In Market Area. , Switch Yard Extension , Dismantling Of Minor Civil / Ms Structure And Levelling Of Yard, Erection Of Barbed Wire Fence With Mid-Supporting Structures And Small Gate. , Levelling Of Switchyard After Back-Filling Of Soil Including Supply Of All Related Materials , Charges For Railway Crossing Permission , Charges For Highway Crossing Permission , Construction Of Control Room Building, Boundary Wall, Security Wall, Gate, Approach Road, Water Supply Sanitary & Associated Civil Works At 33/11 K.V. New Sub-Station , Clearing Jungle Including Uprooting Of Rank Vegetation, Grass, Brush Wood, Trees And Saplings Of Girth Up To 30 Cm Measured At A Height Of 1 M Above Ground Level And Removal Of Rubbish Up To A Distance Of 50 M Outside The Periphery Of The Area Cleared. (Csi 2.31) , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/ Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And For All Lift, As Directed By Engineer-In-Charge.(Csi 2.6.1) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources(Csi 4.1.8) , Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.Mild Steel And Medium Tensile Steel Bars(Cs I 5.22.1) , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level :1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources(Csi 5.1.2) , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Of:1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources)Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement (Csi5.2.2) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In:Cement Mortar 1:6 (1 Cement : 6 Coarse Sand( Csi6.1.2) , Supplying And Filling In Plinth Withsand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete.(Csi 2.27) , Earth Filling Under Floors And/Or Corporation Area Including Cost Of Earth Obtainedwith In 8 Km Distance Outside Corporation Area Including All Taxes (If Any) Andits Carriage Including Watering, Ramming In 20 Cm Layers And Dressing Of Earth Etc. All Complete. (Old Csi No. 4.10) , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 And For All Lift.(Csi2.25) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources).(Csi5.3) , Concreting Of 40 Mm Thick Rcc Trench Covers In Mild Steel Framework With Rcc 1:1.5:3 In Cement, Coarse Sand And 2Cm Gaugegraded Hard Stone Ballast With 3Mm Thick Floating Coat Of Neatcement Finish On Top Of Cover Complete With All Labour, Materials And Placing The Same In Proper Position At Required Location Of Cable Trench Within The Substation Area. (Old Csi No. 5.18) , Placing Of Trench Cover Of All Size In Proper Position Including Transportation From Different Places Within The S/S Area Including All Labour, T&P Etc. Required For Proper Completion Of The Work As Per Direction Of Engineer - In - Charge. (Csi No. 20.11) , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete Csi 5.9.1 , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Suspended Floors, Roofs, Landings, Balconies And Access Platform(Csi5.9.3) , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilever (Csi5.9.5) , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Columns, Pillars, Piers, Abutments, Posts And Struts. (Csi5.9.6) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand):(Csi6.4.2) , Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete.(Csi10.2) , 12 Mm Cement Plaster Of Mix :1:6 (1 Cement: 6 Course Sand) External Plastic Are For Height Upto 10M From Ground Level In Less Otherwise Stated.(Csi13.4.2) , 15 Mm Cement Plaster Of Mix :1:6 (1 Cement: 6 Course Sand) External Plastic Are For Height Upto 10M From Ground Level In Less Otherwise Stated.(Csi13.5.2) , 12 Mm Cement Plaster Of Mix :1:4 (1 Cement: 4 Course Sand) Finished With A Floating Coat Of Neat Cement Of Mixenternal & External Plaster Are For Height Upto 10M From Ground Level In Less Otherwise Stated.(Csi13.7.2) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:1½:3 (1 Cement: 1½ Coarse Sand (Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources).(Csi4.1.2) , Kota Stone Slab Of 25 Mm Thickflooring Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1Cement : 4 Coarse Sand) :(Csi11.26) , Providing And Laying 60Mm Thick Faciory Made Cement Concrete Interlocking Paver Block Of M -30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Line Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge.(Csi16.68) , Providing And Laying Rectified Glazed Ceramic Floor Tiles Of Size 300X300 Mm Or More (Thickness To Be Specified By The Manufacturer), Of 1St Quality Conforming To Is : 15622, Of Approved Make, In All Colours, Shades, Except White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing With Grey Cement Slurry @ 3.3 Kg/ Sqmincluding Pointing The Joints With White Cement And Matching Pigments Etc., Complete.(Csi11.40) , Providing And Laying Polished Granite Stoneslab Colour Of Black, Cherry/Ruby Red Or Equivalent Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing , Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge.(Csi11.56.1) , Providing Edge Moulding To 18 Mm Thick Marble Stone Counters, Vanities Etc., Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge.Granite Work., (Old Csi No. 28.19) , S/F Galvanized Mosquitos Proof Heavy Quality Iron Wire Gauge (14X24) Over Window Frames And Including Supply Of C.P. Teak Wood Battens 8Cm X 1Cm. And Including Supply And Fixing Of Necessary Screws, All Materials,Labour Andt&P Etc. Required For Proper Complete. (Old Csi No.8.44) , Providing And Fixing G.I. Chain Link Fabric Fencing Made Of G.I. Wire Of Dia 4 Mm Of Required Width In Mesh Size 50X50 Mm Including Strengthening With 2 Mm Dia Wire Or Nuts, Bolts And Washers As Required Complete As Per The Direction Of Engineer- In-Charge.(Csi16.70.1) , Providing And Fixing Factory Made Isi Marked Steel Glazed Doors, Windows And Ventilators,Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) Side /Top /Centre Hung, With Beading And All Members Such As F7d,F4b, K11 B And K12 B Etc. Complete Of Standard Rolled Steel Sections, Joints Mitred And Flash Butt Welded And Sash Bars Tenoned And Riveted, Including Providing And Fixing Of Hinges, Pivots, Priming Coat Of Approved Steel Primer, But Excluding The Cost Of Other Fittings,Glass Panescomplete All As Per Approved Design, (Sectional Weight Of Only Steel Members Shall Be Measured For Payment).(Csi10.11.1) , Renewing Panes Of 4.8 To 5.7 Mm Glass Including Supply Of Glass With Putty And Brads Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work.(A) Glass Of 5 Mm Thick. (Csi No. 20.04) , Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws.( Csi9.20.1) , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer- In-Charge) Of Total Coated Thickness 0.50Mm (Base Metal Of Minimum 0.45Mm Thickness With Total Coating Thickness Of 0.05Mm) With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In- Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required.(Csi12.50) , S/F Welded Wire Mesh Size 75X25mm And Rectangularmade Out Of 10 Swg Over M.S. Angle Frame With M.S. Flat Welded As Required Including Cost Of Drilling Holes, Washer Welding Etc As Required Including Cost Of All Material, Labourand T&P Etc. Required For Proper Completion Of Work . Except Cost Of M.S Angle And Flat. ( Old Csi No. 9.22) , Arranging And Spreding 75 Mm Thick Broken Grit 20 Mm (Granite Stone)Uniformfor Turfing Over 100Mm Thick Base Course Of C.C. In 1:4:8 (1Cement:4Coarse Sand: 8, 40Mm Stone Ballast) Top Finish By Brooming Of Cement Mortar 1:4(1Cement: 4 Coarse Sand) Including Supply Of All Materials, Labour And Tools And Plants Etc. Required For Proper Completion. (Csi No. 29.2) , Add For Plaster Drip Course/ Groove In Plastered Surface Or Moulding To R.C.C. Projections. (Csi5.30) , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete.(Csi13.80) , Distempering With 1St Quality Acrylic Distemper (Ready Mixed) Having Voc Content Less Than 50 Gram/Litre, Of Approved Manufacturer And Of Required Shade And Colour All Complete To Achieve Even Shade And Colour :New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Having Voc Content Less Than50 Gram/Litre.(Csi 13.41.1) , Finishing Walls With Textured Exterior Paint Of Required Shade :New Work (Two Or More Coats Applied @ 3.28 Ltr/10 Sqm) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20Kg/10 Sqm. (Csi13.45.1) , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture (Csi 13.62.1) , Supply And Filling Brick Bat In Soak Pit Including All Labour,Material And T&P Etc Complete. (For 01 Soak Pit)Nsi Ref No. 6.23 , Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved.(Csi15.60) , Supply And Fixing Of Syntex Or Equivalent Make Water Storage Tank Including All Materials, Labours, T&P Etc Required For Proper Completion Of Work. ( Old Csi No. 26.12) , Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete :25 Mm Nominal Bore.(Csi18.18.3) , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes Of 25 Mm Diahaving Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.(Csi18.9.3) , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes Of 20 Mm Diaconceled In Wall Including Cutting And Making Good The Wall Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.(Csi18.8.2) , Providing And Laying Swr,110 Mm Dia Pvc ( Finolex Or Equivalent ) Pipe Including Cost Of Excavation, C.C Etc Including Its Jointing And Connection, All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work. ( Old Csi No. 27.29 C) , Providing And Fixing Water Closet Squatting Pan (Indian Type W.C. Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever) Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests.(Csi17.1.1) , Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps.(Csi17.7.1) , Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430X260x350 Mm Or 340X410x265 Mm Sizes Respectively.(Csi17.23) , Providing And Fixing P.V.C. Waste Flexible Pipe Of 40 Mm Dia Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. (Csi17.28.2.2) , Providing And Fixing 100 Mm Sand Cast Iron Grating For Gully Trap.(Csi17.29) , Supply And Fixing Cp Nahani Trap India Make Of Heavy Approved Quality Complete With Ci Grating,Includingsupply Of All Materials,Labour And T&P Etc. Required For Proper Completion Of The Work. (Csi No. 27.21A) , Providing And Fixing Soap Dish Chromium Plated With Brackets Fixed To Wooden Cleats With Brass Screws Including Supply Of All Materials,Labour And T&P Etc.Required For Proper Completion Of The Work. (Old Csi No. 27.19) , Providing And Fixing 600 Mm X 20 Mm Size C.P. Brass Towel Rail Of Approved Qualityincluding Bracketsincluding Supply Of All Materials,Labour And T&P Etc. Required For Proper Completion Of The Work And Cutting And Making Good The Wall Plaster Etc. Required For Work. (Old Csi No. 27.17) , Providing And Fixing 600 Mm X 450 Mm Beveled Edge Mirror Of Atul,Kiran Makeglass With Indian Polish 6.50 Mm Thick Complete With Back Of 600 Mm X 450 Mm X 6 Mm Hard Board Sheet Fixed To Wooden Cieats With C.P. Brass Screws And Washers Including Supply Of All Materials, Labour And T&P Etc.Required For Proper Completion Of The Work. (Old Csi No. 27.15) , Supply And Fixing Cp Nahani Trap India Make Of Heavy Approved Quality Complete With Ci Grating,Includingsupply Of All Materials,Labour And T&P Etc. Required For Proper Completion Of The Work. (Old Csi No. 27.21B) , Providing And Fixing Unplasticised P.V.C. Connection Pipe With Ptmt Nuts, Collar And Bush Of Approved Quality And Colour.15 Mm Nominal Bore With 45 Cm Length.(Csi18.74.2) , Providing And Fixing C.P. Brass Bib Cock Of Approved Quality Conforming To Is:8931 :15 Mm Nominal Bore (Csi18.49.1) , Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is:8931 15 Mm Nominal Bore.(Csi18.53.1) , Providing And Fixing Gun Metal Gate Valve 25 Mm Nominal Bore With C.I. Wheel Of Approved Quality (Screwed End) :(Csi 18.17.1) , Providing And Fixing Cp Brass Cp Brass Piller Cock 15 Mm Dia. Heavy Quality ( 400Gm) ( L & K And Equi.) Fittings, Isi Mark Heavy Quality Including Supply Of All Materials, Labour And T&P Required For Proper Completion Of Work. ( Old Csi No. 26.16 J) , Wiring Point For Light With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable In Pvc Conduit With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Wire Drawn Inside The Conduit Concealed In Wall, Gp Box, Piano Type Switch And Ceiling Rose/Angle/ Batten Holder On 3 Mm. Thick Phenolic Laminated Backelite Sheet Etc. Complete In All Respect As Per Direction Of E/I. (Pwd131-C) , Wiring Point For Plug With 1 Sq. Mm.Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable In Pvc Conduit Conceled In Wall With 1.5 Sq. Mm. Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Wire Drawn Inside The Conduit On Surface, Piano Type Switch And Ceiling Rose/Angle/ Batten Holder On 3 Mm. Thick Phenolic Laminated Backelite Sheet Etc. Complete In All Respect As Per Direction Of E/I. (Pwd134-C) , Wiring Point For Fan /Fresh Air Fan (Light Duty Exhaust Fan)With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Single Core Copperconductor Cablein Pvc Conduit Conceled In Wall With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Wire Drawn Inside The Conduit Piano Type Switch And Ceiling Rose/Angle/ Batten Holder On 3 Mm. Thick Phenolic Laminated Backelite Sheet Etc. Complete In All Respect As Per Direction Of E/I. (Pwd123-C) , Supply And Fixing Of Power Plug With 15A/250 Volt Flush Type Switch And 5 Pin 15A/250V Flush Type Universal Socket In Suitable M.S. Box Of 175Mm X 100Mm X 50Mm Size With Phenolic Laminated Bakelite Sheet Cover 3Mm Thick Fixed With Brass Machine Screw And Cup Washer. (Pwd1139) , Supply And Wiring Of Submain With Two Number 4 Sq.Mm. Frlsh Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Dia Pvc Conduit On Surface, With One Number 2.5 Sq. Mm. Multistrand Copper Drawn In Conduit Complete In All Respect. (Pwd216-C) , Supply And Fixing Of Led Tube Light Batten Fitting Suitable For Up To 1 X 22 Watt Led Tube Light On Surface Complete In All Respect.(Csi29.135) , Supply And Fixing Of 5 Blade Exhaust Fan Ventile Air Dx 225 Mm Of Havellsor Equivalent Make Including All Material, T&P Etc Required For Proper Completion Of Work As Approved By Engineer In Charge.(Csi29.133) , Supply And Fixing Of 3 Blade Ceiling Fan 1200 Mm Of Havells Or Equivalent Including All Material, T&P Etc Required For Proper Completion Of Work As Approved By Engineer In Charge.(Old Csi No. 28.39) , S/R Of Regulator For Ceiling Fan Of Gec Or Equivalent Make Including Cost Of All Labour Material, T&P Etc. Required For Proper Completion Of The Work. ( Csi22.60B) , S&F Of 6 Amp To 32 Amp. Mcb (10 Ka) C Curve. (Pwd C.S.I.No. 1002-B) , S&F Of 100 Amp. Four Pole Change Over Switch On 40Mm X 40Mm X 6Mm Angle Iron Frame, Including The Cost Of Labour, T&P, Painting And Other Material Required For Proper Completion Of The Work As Per Direction And Satisfaction Of Engineer In Charge. (Pwd C.S.I. No. 378) , Supply And Fixing Of Led Street Light Fitting Having Dia Cast Aluminum Body And Diffuser With Driver Set Suitable For 110 To 130 Watt. Confirming To Ip 66 Production Complete In All Respect. (Pwd1424) , Providing And Fixing Circular/ Hexagonal Cast Iron Or M.S. Sheet Box For Ceiling Fan Clamp, Of Internal Dia 140 Mm, 73 Mm Height, Top Lid Of 1.5 Mm Thick M.S. Sheet With Its Top Surface Hacked For Proper Bonding, Top Lid Shall Be Screwed Into The Cast Iron/ M.S. Sheet Box By Means Of 3.3 Mm Dia Round Headed Screws, One Lock At The Corners. Clamp Shall Be Made Of 12 Mm Dia M.S. Bar Bent To Shape As Per Standard Drawing.). (Csi10.18) , Pre-Construction Anti-Termite Treatment, By Creating A Barrier Under And Around The Columns Pits, Foundation Trenches, Under Floors, Junctions Of Walls &Floors, Around The External Perimetre Of Building, Expansion Joints, Surrounding Of Pipes And Conduits Etc. (Plinth Area Of The Building At Ground Floor Only Shall Be Measured As Per I.S. 6313 (Part Ii 1981))With Eldrine Emulsifiable 0.2% Concentration Or Any Other Approved Material Such As Heptachlore Or Chlordance Will Be Used. The Consumption Of Emulsion Shall Be (I) Foundation And Masonary @ 5 Ltrs/Sqm, (Ii) Back Fills In Immediate Contact Of Foundation@ 7.5 Ltrs. / Sqm, (Iii) Top Surface Of Plinth Filling @ 5 Ltrs / Sqm, ( Iv) Junction Of Walls & Floors @ 7.5 Ltrs / Sqm, (V) Soil Along External Perimetre Of Building @ 7.5 Ltrs / Sqm (Vi) Under Apron Of The Building @ 5 Ltrs. /Sqm. The Rates Includes Cost Of All Materials, Labour, Equipments, T&P Complete.(Csi29.41) , Cleaning And Dressing Of Site For Tube Well Boring Including Cost Of All Labour, Materials And T&P Required Forproper Completion Of Work. (Old Csi No. 19.03) , Drilling For 200 Mm Dia Bore Fromrom 0 M Bgl To 90 M Bgl Work To Be Completed As Per Direction Of Engineer I/C .(Old Csi19.04G I) , Drilling For 200 Mm Dia Bore Fromrom 90M Bgl To 120 M Bgl Work To Be Completed As Per Direction Of Engineer I/C .(Old Csi19.04G Ii) , Lowering Of Tube Well Assembly Alongwith Shrouding With Pea Gravels, Testing, Verticality Of Tube Well And Washing Of The Tube Well From G.L. To90 Meter B.G.L. The Cost Including All Labour, Materials, T&P Required For Proper Completion Of Work But Excluding The Cost Of Slotted Pipe/ Plain M.S/Pvc.Pipe Assembly And Pea Gravel.(Old Csi No. 19.05I) , Lowering Of Tube Well Assembly Alongwith Shrouding With Pea Gravels, Testing, Verticality Of Tube Well And Washing Of The Tube Well From 90. To 120Meter B.G.L. The Cost Including All Labour, Materials, T&P Required For Proper Completion Of Work But Excluding The Cost Of Slotted Pipe/ Plain M.S/Pvc.Pipe Assembly And Pea Gravel.(Old Csi No. 19.05Ii) , Providing160mm Dia Plain Pvc Casing Pipes (Aroma /Supreme) (Pressure10 Kg./ Sqcm.) For Making Tubewell Assembly And Cartage To Boring Site, Including Cost Of All Labour, Materials And T&P Required For Assembly Making And Proper Completion Of Work. (Old Csi No. 19.09) , Providing 160Mm Dia Slotted Pvc Casing Pipes (Aroma /Supreme) (Pressure10 Kg./ Sqcm.) For Making Tubewell Assembly And Cartage To Boring Site, Including Cost Of All Labour, Materials And T&P Required For Assembly Making And Proper Completion Of Work. (Old Csi No. 19.09) , Development Of Tubewell By O.P. Unit (5 Hp To 10 Hp Submersible Pump Set), Including Bringing Column Pipe For The Op Unit, Assembling, Electric Connections, Running For Required Period, Dismentling And Taking Out & Carrying Away And Cleaning The Site With Cost Of All Labour, Materials, T&P And Fuel / Electricity Charges Etc Required For Proper Completion Of Work And As Per Direction Of Engineer-In-Charge. (Old Csi No. 19.14) , Supply And Fixing Ofms Ring Of Heavy Quality Of 150 Mm Dia Including Cost Of All Materials, Labour And T&P Etc Required For Proper Completion Of Work.(Csi29.43E) , Supply And Fixing Of Pvc. Bail Plug Of Heavy Quality Of 110 Mm Dia Including All Labour Material & T&P.(Csi29.46A) , Supply And Fixing Of Pvc Top Plug Of Heavy Qualityof 160 Mm Dia Including All Labour Material & T&P. (Csi29.47A) , Supply And Fixing Of 1.20M Long Holding Support Clamps For 300 To 100Mm Dia Tube Well Pipes. Made Out Of Ms Flats, Pairs Of Bolt-Nuts Etc Complete With All Material, Labour, T&P.(Old Csi No. 19.21) , Supply And Stacking Pee Gravelproperly At Levelled Ground For Measurement As Directed By Engineer I/C, Including All Labour, T&P Required For Proper Completion Of Work.(Old Csi No.19.25) , Supply & Installation Ofsubmersible Pump Of K.S.B/ Calama. Or Eqt. Make Of 3 Hp Outlet 50 Mm Dia. Or More, Head 60/24, Discharge 6000/14000 Lph Including Cost Of Labour, T&P And Material Required For Completion Of Work. (Csi29.55D) , Supply & Installation Of Electrical Control Panel Of L&T / Havells Or Equivalent Make For Submersible Pump / Pumpset For 3 H.P Pump Set Single Phase Containing Contractor Relay Condenser. (Csi29.54C) , Supply And Fixing Of Submersible Cable Havelsor Equivalent Make, For Submersible Pumpof 2.5 Mm2 For Pumpabove 1 Hp And Up To 3 Hpcomplete In All Respect.(Old Csi No.19.33 B ) , Supply & Fixing Of Steel Wire Rope Forsubmersible Pump Including Cost Of Labour, T&P And Material Required For Completion Of Work.(Csi 29.56) , Supply And Fixing Of G.I. (B Class ) Column Pipes Of 40 Mm Dia Jtc/ Jindal Make With Column Coupling Socket As Required For Proper Completion Of Workincluding All Labour Material & T&P. (Old Csi No. 19.22) , Lowering Of M.S. Column Pipe Of 40 To 50 Mm Diain Tubewell Including Supply Of Nuts, And Bolts, Packing And Also Carriage Of Pipe From Workshop To Site Including All Labour, T&P Etc. Required For Proper Completion Of The Work.(Old Csi No.19.27 B ) , Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required.(Dsr El No 5.6) , Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required.(Dsr El No 5.12) , Control Room Extention At Existing 33/11 K.V. Sub- Station , Demolishing R.C.C. Work Manually/ By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In- Charge.(Csi15.3) , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.(Csi15.7.4) , Demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge.(Csi 15.2.1) , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And For All Lift, As Directed By Engineer-In-Charge.(Csi 2.6.1) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources(Csi 4.1.8) , Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.Mild Steel And Medium Tensile Steel Bars(Cs I 5.22.1) , Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level :1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources(Csi 5.1.2) , Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Of:1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources)Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement (Csi5.2.2) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In:Cement Mortar 1:6 (1 Cement : 6 Coarse Sand( Csi6.1.2) , Earth Filling Under Floors And/Or Corporation Area Including Cost Of Earth Obtainedwith In 8 Km Distance Outside Corporation Area Including All Taxes (If Any) Andits Carriage Including Watering, Ramming In 20 Cm Layers And Dressing Of Earth Etc. All Complete. (Old Csi No. 4.10) , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 And For All Lift.(Csi2.25) , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources).(Csi5.3) , Concreting Of 40 Mm Thick Rcc Trench Covers In Mild Steel Framework With Rcc 1:1.5:3 In Cement, Coarse Sand And 2Cm Gaugegraded Hard Stone Ballast With 3Mm Thick Floating Coat Of Neatcement Finish On Top Of Cover Complete With All Labour, Materials And Placing The Same In Proper Position At Required Location Of Cable Trench Within The Substation Area. (Old Csi No. 5.18) , Placing Of Trench Cover Of All Size In Proper Position Including Transportation From Different Places Within The S/S Area Including All Labour, T&P Etc. Required For Proper Completion Of The Work As Per Direction Of Engineer - In - Charge. (Csi No.20.11) , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete Csi 5.9.1 , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Suspended Floors, Roofs, Landings, Balconies And Access Platform(Csi5.9.3) , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilever (Csi5.9.5) , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Columns, Pillars, Piers, Abutments, Posts And Struts. (Csi 5.9.6) , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand):(Csi6.4.2) , Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete.(Csi10.2) , 12 Mm Cement Plaster Of Mix :1:6 (1 Cement: 6 Course Sand) External Plastic Are For Height Upto 10M From Ground Level In Less Otherwise Stated.(Csi13.4.2) , 15 Mm Cement Plaster Of Mix :1:6 (1 Cement: 6 Course Sand) External Plastic Are For Height Upto 10M From Ground Level In Less Otherwise Stated.(Csi13.5.2) , 12 Mm Cement Plaster Of Mix :1:4 (1 Cement: 4 Course Sand) Finished With A Floating Coat Of Neat Cement Of Mixenternal & External Plaster Are For Height Upto 10M From Ground Level In Less Otherwise Stated.(Csi13.7.2) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:1½:3 (1 Cement: 1½ Coarse Sand (Zone-Iii) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources).(Csi4.1.2) , Kota Stone Slab Of 25 Mm Thickflooring Over 20 Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) :(Csi11.26) , S/F Galvanized Mosquitos Proof Heavy Quality Iron Wire Gauge (14X24) Over Window Frames And Including Supply Of C.P. Teak Wood Battens 8Cm X 1Cm. And Including Supply And Fixing Of Necessary Screws, All Materials,Labour Andt&P Etc. Required For Proper Complete. (Old Csi No.8.44) , Providing And Fixing Factory Made Isi Marked Steel Glazed Doors, Windows And Ventilators,Fixing With 15X3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Block 15X10x10 Cm Of C.C. 1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) Side /Top /Centre Hung, With Beading And All Members Such As F7d,F4b, K11 B And K12 B Etc. Complete Of Standard Rolled Steel Sections, Joints Mitred And Flash Butt Welded And Sash Bars Tenoned And Riveted, Including Providing And Fixing Of Hinges, Pivots, Priming Coat Of Approved Steel Primer, But Excluding The Cost Of Other Fittings,Glass Panescomplete All As Per Approved Design, (Sectional Weight Of Only Steel Members Shall Be Measured For Payment).(Csi10.11.1) , Renewing Panes Of 4.8 To 5.7 Mm Glass Including Supply Of Glass With Putty And Brads Including Supply Of All Materials, Labour And T&P Etc. Required For Proper Completion Of The Work.(A) Glass Of 5 Mm Thick. (Csi No. 20.04) , Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 (Part I) Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters.35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws.( Csi9.20.1) , Providing And Fixing Precoated Galvanised Iron Profile Sheets (Size, Shape And Pitch Of Corrugation As Approved By Engineer- In-Charge) Of Total Coated Thickness 0.50Mm (Base Metal Of Minimum 0.45Mm Thickness With Total Coating Thickness Of 0.05Mm) With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Suppliedin Single Length Upto 12 Metre Or As Desired By Engineer-In- Charge. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required.(Csi12.50) , Pre-Construction Anti-Termite Treatment, By Creating A Barrier Under And Around The Columns Pits, Foundation Trenches, Under Floors, Junctions Of Walls &Floors, Around The External Perimetre Of Building, Expansion Joints, Surrounding Of Pipes And Conduits Etc. (Plinth Area Of The Building At Ground Floor Only Shall Be Measured As Per I.S. 6313 (Part Ii 1981))With Eldrine Emulsifiable 0.2% Concentration Or Any Other Approved Material Such As Heptachlore Or Chlordance Will Be Used. The Consumption Of Emulsion Shall Be (I) Foundation And Masonary @ 5 Ltrs/Sqm, (Ii) Back Fills In Immediate Contact Of Foundation@ 7.5 Ltrs. / Sqm, (Iii) Top Surface Of Plinth Filling @ 5 Ltrs / Sqm, ( Iv) Junction Of Walls & Floors @ 7.5 Ltrs / Sqm, (V) Soil Along External Perimetre Of Building @ 7.5 Ltrs / Sqm (Vi) Under Apron Of The Building @ 5 Ltrs. /Sqm. The Rates Includes Cost Of All Materials, Labour, Equipments, T&P Complete.(Csi29.41) , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete.(Csi13.80) , Distempering With 1St Quality Acrylic Distemper (Ready Mixed) Having Voc Content Less Than 50 Gram/Litre, Of Approved Manufacturer And Of Required Shade And Colour All Complete To Achieve Even Shade And Colour :New Work (Two Or More Coats) Over And Including Water Thinnable Priming Coat With Cement Primer Having Voc Content Less Than50 Gram/Litre.(Csi 13.41.1) , Finishing Walls With Textured Exterior Paint Of Required Shade :New Work (Two Or More Coats Applied @ 3.28 Ltr/10 Sqm) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20Kg/10 Sqm. (Csi13.45.1) , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture (Csi13.62.1) , Disposal Of Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved.(Csi15.60) , Wiring Point For Light With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable In Pvc Conduit With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Wire Drawn Inside The Conduit Concealed In Wall, Gp Box, Piano Type Switch And Ceiling Rose/Angle/ Batten Holder On 3 Mm. Thick Phenolic Laminated Backelite Sheet Etc. Complete In All Respect As Per Direction Of E/I. (Pwd131-C) , Wiring Point For Plug With 1 Sq. Mm.Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cable In Pvc Conduit Conceled In Wall With 1.5 Sq. Mm. Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Wire Drawn Inside The Conduit On Surface, Piano Type Switch And Ceiling Rose/Angle/ Batten Holder On 3 Mm. Thick Phenolic Laminated Backelite Sheet Etc. Complete In All Respect As Per Direction Of E/I. (Pwd134-C) , Wiring Point For Fan /Fresh Air Fan (Light Duty Exhaust Fan)With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Single Core Copper Conductor Cablein Pvc Conduit Conceled In Wall With 1.5 Sq. Mm.Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Wire Drawn Inside The Conduit Piano Type Switch And Ceiling Rose/Angle/ Batten Holder On 3 Mm. Thick Phenolic Laminated Backelite Sheet Etc. Complete In All Respect As Per Direction Of E/I. (Pwd123-C) , Supply And Fixing Of Power Plug With 15A/250 Volt Flush Type Switch And 5 Pin 15A/250V Flush Type Universal Socket In Suitable M.S. Box Of 175Mm X 100Mm X 50Mm Size With Phenolic Laminated Bakelite Sheet Cover 3Mm Thick Fixed With Brass Machine Screw And Cup Washer. (Pwd1139) , Supply And Wiring Of Submain With Two Number 4 Sq.Mm. Frlsh Pvc Insulated 1100 V Grade Multistrand Single Core Copper Conductor Cable In 20 Mm Dia Pvc Conduit On Surface, With One Number 2.5 Sq. Mm. Multistrand Copper Drawn In Conduit Complete In All Respect. (Pwd 216-C) , Supply And Fixing Of Led Tube Light Batten Fitting Suitable For Up To 1 X 22 Watt Led Tube Light On Surface Complete In All Respect.(Csi29.135) , Supply And Fixing Of 5 Blade Exhaust Fan Ventile Air Dx 225 Mm Of Havellsor Equivalent Make Including All Material, T&P Etc Required For Proper Completion Of Work As Approved By Engineer In Charge.(Csi29.133) , Supply And Fixing Of 3 Blade Ceiling Fan 1200 Mm Of Havells Or Equivalent Including All Material, T&P Etc Required For Proper Completion Of Work As Approved By Engineer In Charge.(Old Csi No. 28.39) , S/R Of Regulator For Ceiling Fan Of Gec Or Equivalent Make Including Cost Of All Labour Material, T&P Etc. Required For Proper Completion Of The Work. ( Csi22.60B) , S&F Of 6 Amp To 32 Amp. Mcb (10 Ka) C Curve. (Pwd C.S.I. No. 1002-B) , S&F Of 100 Amp. Four Pole Change Over Switch On 40Mm X 40Mm X 6Mm Angle Iron Frame, Including The Cost Of Labour, T&P, Painting And Other Material Required For Proper Completion Of The Work As Per Direction And Satisfaction Of Engineer In Charge. (Pwd C.S.I. No. 378) , Supply And Fixing Of Led Street Light Fitting Having Dia Cast Aluminum Body And Diffuser With Driver Set Suitable For 110 To 130 Watt. Confirming To Ip 66 Production Complete In All Respect. (Pwd1424) , Supply And Fixing 10Sqmm Alluminium Cable Required For Proper Complection Of Work.(Nsi) , S&F Of 40 Amp Dp Mcb (10 Ka) C Curve. (Pwd C.S.I. No. 1010-B) , Providing And Fixing Circular/ Hexagonal Cast Iron Or M.S. Sheet Box For Ceiling Fan Clamp, Of Internal Dia 140 Mm, 73 Mm Height, Top Lid Of 1.5 Mm Thick M.S. Sheet With Its Top Surface Hacked For Proper Bonding, Top Lid Shall Be Screwed Into The Cast Iron/ M.S. Sheet Box By Means Of 3.3 Mm Dia Round Headed Screws, One Lock At The Corners. Clamp Shall Be Made Of 12 Mm Dia M.S. Bar Bent To Shape As Per Standard Drawing.). (Csi10.18)
|