Repairing & rejuvenation of electro-mechanical accessories for Bhangadali W/S scheme Pump house no -1 in Binpur-I block under Jhargram Mechanical Division, PHE. Dte.- Supply and delivery of following material at site:-102 mm. dia 0-10 kg/cm² range wall mounted pressure gauge complete with brass cock & other fittings as per direction of E.I.C for tubewell outside the pump house.Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024.with latest amendments. 2 102 mm. dia. wall mounted depth gauge capable to measure direct reading in feet with 6mm steel air pipe with socket (assembly should be 50mtr. long) including supply of one good quality hand pump hand pump for tubewell outside the pump house. (This cost includes 15 mm. dia. G.I. Pipe approx. 90 ft. length and specials) Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024.with latest amendments. 3 M.S fabricated split type suitable tube well cover as per tube well housingwith necessery clamping arrangementincluding provision of holes for column pipe ,air pipe and cable entry etc. all complete as per direction of E.I.C 4 Anti-snapping safety device for above pump by supplying suitable size. Nylone rope of required length (double) including supply of all necessary materials as required. 5 1.1 KV Grade 415 V, 2 core 10 sq.mm. PVC sheathed XLPE insulated Al. armoured cable conforming to IS:7098 (PART-1) 2011 with latest amendmends as applicable.Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024.with latest amendments. 6 50 mm dia, P.N. 1.0, CIDF Non return valve conforming to IS: 5312, part-I. Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024.with latest amendments. 7 50 mm dia, P.N. 1.0, CIDF sluice valve (non-rising) conforming to IS: 14846.Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024.with latest amendments. 8 50 mm dia ,PN-1.0 CIDF wafer typebutterfly valve.Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024.with latest amendments. 9 50mm dia heavy type suitable length CI/MS Black pipes (for common delivery header,backwash line for pump under sl no-1, along with necessary bends, specials, fittings , viz flanges, bolts, nuts, gaskets, concentric enlarger , MS dismenteling joint, for connecting main pipe line etc. including providing MS/Bricks/PCC support for laying of pipes, valves as required to make the installation complete. (This includes the cost of S/D of delivery header & short piece of required length to connect the delivery pipe line) 10 230 V MCC cum PDB (1-3 HP with DOL, Direct Online starter) having changeover for bypass arrangement with minimum 2mm thickness and degree of protection IP-54, conforming toIS-8623 with suitable Bus bar, Digital Voltmeter Ammeter, Contactor, delay timer, MCB, Valve Actuator,starter etc. with PLC logic as detailed in attached technical specification.Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024.with latest amendments. 11 10KVA, single phase, oil cooled type having unbalance 115-289V input voltage and 230 V(± 1%) output voltage, auto/manual servo voltage stabilizer with U/V,O/V,O/L protection with MCBat output side &input MCCB, Ammeter Bell etc. As per IE Rules and as per technical specification. Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024.with latest amendments. 12 LED street light luminarie IP 66 LM6-HPDC Housing Street light aerodynamically designed with better thermal management/ Potted driver is to be provided,the luminaire and housing should be from the same manufacturer(cat no- BRP052 LED 045 CW SLMR FG S1 PSU GR ,System Efficacy greaterthan 100 lumen/watt) Make-Philips OR Equivalent and same techinal specification ofHavells.The manufacturer has to provide LM79/LM80 reports corresponding to the luminaire/LED Chip along with type test Certificate.Respectively the luminaire manufacturer should have an in house NABL Accredited testing facility. 13 6-32 Amp Amp,10 kA, 240/415V, 50 Hz SP MCB conforming to IS / IEC: 60898-1, "C" characteristics. (6 Amp- 1 nos., 16 Amp-1 no.)Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024.with latest amendments. 14 10 Amp,10 kA, 240/415V, 50 Hz SPN MCB conforming to IS / IEC: 60898-1, "C" characteristics.Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024.with latest amendments. 15 6 way SP&N Double Door horizontal Distribution Board (I/C 2 + O/C 4) conforming to IS 13032 & IS 8623 and IP42/43. Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024.with latest amendments. 16 63 Amp. 2 pole on load change over switch Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024.with latest amendments. 17 63 Amp,240V, 50 Hz Double pole main switch conforming to IS / IEC: 60947-3, "C" characteristics with enclosure.Make :- .Make: havells/standard/ any other approved make. 18 63 Amps,4 Way Wall mounted Busbar chember (Copper).Make: havells/standard/ any other approved make. 19 63 Amp, 240/415 V Porcelain fuse unit (Base & Bridge) Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024.with latest amendments. 20 Hard wooden board (450mm X 304.8 mmx 2 mm thick) 21 Installation of itemLaying of cable on wall/surface incl. S & F of MS saddles with earthing attachment in 10 SWG GI (Hot Dip) wire, making holes etc. as necy. mending good damages and painting all complete as per direction of E.I.C. 22 Supplying and fixing of compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry ofcable .all complete as per direction of E.I.C. 23 Finishing the end of cable by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materialsall complete as per direction of E.I.C. 24 Making internal wiring/electrification of the Pump house by (2x 22/0.3 (1.5 sqmm) + 1x 22/0.3 (1.5 sqmm) single core PVC insulated multistrand FRLSH Grade flexible copper wire through 20 mm PVC conduit pipe/casing by supplying one no. 40 Amp, 10kA, 240/415V,50 HzSPN/DP MCB Isolator conforming to IS / IEC: 60947-3, "C" characteristics. (As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019) with required module PVC Board & piano key type switch. (ave. run 6 mtr). i) LED Tube set point-2 nos., Bulk Head light point- 1 no., 5 pin 6 Amps. Plug point- 1 no., 16 Amp socket & switch- 1 no, indicator- 1 no. each,with necy. earthing arrangement & one fan point (Total point 6 nos. points) including drawing power by suitable gauge (2.5 mm2) of copper wire from installed cut-out to SPN/DP MCB within DB through 20 mm PVC casing capping (precision make) as per direction of EIC (fittings should be of Philips make & wiring should be with continuous earthing arrangement and 20W two nos. 4 ft long LED tube light setsPHILIPS Astra Line, one no. bulk head (Endura WT202W LED6S NW PSU S2 PC), one no. 0-4 step fan regulator (Humfree), fittings etc to be supplied by agency). 25 Installation, testing & commisioning of above supplied Pumping Machinery, MCC,valves etc by jointing submersible cable within the tubewell situated outside the pump house by making derrick arrangement by assembling the column pipes properly and fitting, fixing the pressure gauge, depth gauge, air pipe etc. in position and erection of delivery line & wash out line with the C.I specials and Tee including mending damages goods etc.all complete as per direction. This also includes the charges for laying submersible cable from tubewell to control panel by underground and saddle on wall and connection with required feeder of panel all complete. 26 Making required nos. of brick pillar 0.25 mtr. X 0.25 mtr. For supporting of valves and pipes with 12 mm thick plaster and net cement finish complete. 27 S&F of 3" dia 1.5 mt minipole with baseplate to be fixed on rooftop incl. S&F of 1.5 mtr long arm bracket (removable type) incl. CC (6:3:1) muffing(450X450X600) with 3 mm thick neat cement finish & painting incl. S&F of 200x150x100 mm 16 SWG GI loop box with necessary power connection by3x 22/0.3 (1.5 Sq.mm) (2 nos. P&N and 1 no. ECC) "FRLSH" PVC insulated & unsheathed copper wire (Approved make) in 20 mm size PVC rigid conduit "FRLSH" (Precision make) incl. necy. fittings as required as per direction of EIC. 28 (a) Earthing with 50 mm ISI mark medium diameter G.I. pipe 3.64 mm thick x 3Mtr. (10ft.) long and 1 x 4 SWG G.I. wire (4Mtr.long) 13 mm diameter x 80mm (3inch) long G.I. Bolts, double nuts, washer including S & F of 15mm diameter G.I. pipe protection (1 Mtr. Long) to be filled with bitumen partly below ground level to an average depth of 3.65Mtr.(12ft.) below the ground level and restoring the surface duly rammed.i) For soft soil by ISI Medium GI pipe. 29 (b) Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm diaholes on the GI pipe. 30 (c) Extra for treatment of soil by salt and charcoal coke for pipe electrode. 31 (d) Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.Length of busbar is 0.5 mtr. 32 Add GST @ 18 % 33 Add Cess @ 1 %
|