Tender For Provision Of Defi Md Accn Forors At Gandhidham Mil Station. - Lump sum price worked out by the contractor for "BUILDING WORKS"as listed in Schedule ‘A’ Part-I representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 28 2 Lump sum price worked out by the contractor for "SITE CLEARANCE EXCAVATION & EARTH WORK "as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 29 3 Lump sum price worked out by the contractor for "INTERNAL WATER SUPPLY WORK "as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 30 4 Lump sum price worked out by the contractor for "INTERNAL ELECTRIFICATION WORK"as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 35 5 Lump sum price worked out by the contractor for "ROAD , PATH, CULVERT AND CATTLE TRAP WORK" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 42 6 Lump sum price worked out by the contractor for "SEWAGE DISPOSAL WORK"as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 44 7 Lump sum price worked out by the contractor for "AREA DRAINAGE WORK"as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES B/F from Sl page No. 46 8 Lump sum price worked out by the contractor for " SECURITY FENCING & GATE WORK"as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 49 9 Lump sum price worked out by the contractor for " STAND BY ELECTRIC SUPPLY WORK"as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 50 10 Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY WORK"as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 51 11 Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION WORK"as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 55 12 Sch "A" PART-XII (MISCELLANEOUS ITEMS) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under respective schedule. 13 INTERNAL WATER SUPPLYSupply and fixing of 15 mm bore fancy type chromium plated bib tap with wall flange, screwed for iron pipe or CPVC pipes or for ferrule and fixed complete all as specified and directed. Make -Jaquar ESSCO SERIES or technocommercial equivalent makes as per Appx "C". 14 Supply and fixing of 15 mm bore fancy type chromium plated pillar taps swan Neck tap with right hand operating Knob and fixed complete all as specified and directed. Make -Jaquar ESSCO SERIES or technocommercial equivalent makes as per Appx "C". 15 Supply and fixing of 15 mm bore fancy type chromium plated concealed stop cock, reduced body with adjustable wall flange, and fixed complete all as specified and directed. Make -Jaquar ESSCO SERIES or technocommercial equivalent makes as per Appx "C". 16 Supply and fixing of 15 mm bore fancy type chromium plated sink cock with swinging spout (wall mounted model) with wall flange and fixed complete all as specified and directed.Make - Jaquar ESSCO SERIES or technocommercial equivalent makes as per Appx "C". 17 Supply and fixing of 15 mm bore fancy type chromium plated angular cock, screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and directed.Make -Jaquar ESSCO SERIES or technocommercial equivalent makes as per Appx "C". 18 Supply and fixing of central Hole Basin Mixer with regular spout with popup waste system with 450 mm long braided hoses and fixed complete all as specified and directed.Make -Jaquar ESSCO SERIES or technocommercial equivalent makes as per Appx "C". 19 Supply and fixing of CP wall mixer 2 in 1 system with provision with central spout and connection for over head shower with divertor liver ISI marked complete all as specified and directed.Make -Jaquar ESSCO SERIES or technocommercial equivalent makes as per Appx "C". 20 Supply and fixing of overhead shower 114x114 mm of square shape single flow with rubit cleaning system ABS body crome plated with gray face plate with arm having swivel joint chromium plated complete all as specified and directed.Make -Jaquar ESSCO SERIES or technocommercial equivalent makes as per Appx "C". 21 Supply and fixing of two way angle cock chromium plated fancy type 15 mm bore complete all as specified and directed.Make -Jaquar ESSCO SERIES or technocommercial equivalent makes as per Appx "C". 22 Supply and fixing of health faucit (ABS Body) with 1000 mm long flexible mild steel tube 15 mm dia with wall hook complete all as specified and directed.Make -Jaquar ESSCO SERIES or technocommercial equivalent makes as per Appx "C". 23 INTERNAL ELECTRIFICATIONSupply and fixing load line distribution board TPN vertical, 4 way gouble door type, fixed on wall semi flush with incoming MCCB 4 Poles 125 Amps, 16 KA, busbars, neutrakl link blanking plates complete all as specified and as directed. 24 Supply and fixing TV sockets complete with all accessories complete all as specified and as directed. 25 Supply and fixing PVC metal braided connection pipes for hot water supply with brass adopters 15 mm dia and 450 mm long complete all as specified and as directed. 26 Supply and fixing LED lamp B22 base 10 w Minimum lumen out put 950 lumens at 6500 K CCt for batten holders complete all as specified and as directed. 27 M & L for inverter point wiring for one light, ceiling fan and 5 Amp socket for each roomwith 2.5 sqmm,PVC insulated, unsheathed, single core multistandard copper conductor cable ( FRLS), 1100 volts grade including 2.5 Sqmm PVC insulated, unsheathed, copper conductor cable for earth continuity wire to be drawn through in and including PVC conduit medium grade ISI markedwith its acessories upto the main DBand 15 A switch socket combination with gang box flushed in wallfor inverter power supplycomplete all as specified and as directed. 28 S & F LED security light fitting made out of pressure die cast aluminium powder coated housing high impact resistant 4mm thick toughened glass cover and matrix of power LEDsinbuilt electronic driver up to 4KV surge protection fitted with adjustable pole adapter to enable on site tilt angle setting depending on road geometry CCT5500-6500 CRI greater than 70 , input power 30Woutput operating voltage 140-280V with connection by three core PVC insulatedmultistranded copper conductor sheathed cable of size 1.0 sq mmfixed with & including bracket made of GI pipe 40mm bore light grade, 1.6 mtr long bent to shape required with 2 no MS clamps of suitable size and length, nuts & boltscomplete all as specified and as directed. 29 SEWAGE DISPOSAL WORKM & L for construction of RCC septic tank 150 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 design mix in walls,base slab, baffle walls and roof slab including beams etc with vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter conventional type complete all as specified and directed. 30 M & L for Soakage wells having size 3.6m dia X 6.0m effective depth excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete all as directed and specified 31 M & L for On site Hume Pipe septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for 10 User complete all as specified and directed. 32 M & L for Soakage wells having size 2.4m dia X 3.0m effective depth excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete all as directed and specified. 33 SECURITY FENCING & GATESupply and fixing of CI wheel as rollers of 75 mm dia for gates complete all as specified and directed. 34 STAND BY ELECTRIC SUPPLY WORKSupplying, installing, testing and commissioning Disesel Engine driven generating set 415 volts, 3 phase, 4 wire, engine as per IS : 10001/10002 and alternator as per IS 13364 with inbuilt AMF panel complete with foundation as per design, control panel withnecessary meter and sound proof canopy as per CPCB norms of capacity 10 KVA with all tools & spares complete all as specified & directed and comprising of the following :- 35 (a) AMF Panel : The AMF panel microprocessor based shall be designed for Automatic ON mains failure operation of the generator sets and panel shall complete with interconnections, insulators, two numbers of earthing lugs & with suitable rating of MCCB at incoming & outgoing ends & shall incoroporate the followings :- (i) Electric contactor for both DG and main supply (ii)Main supply voltage monitor (iii) AMF logic unit having protection for over frequency, under frequency, over voltage, under voltage, low lube oil, & high water temp for engine (iv)Combined meter (MFM) for voltage, current, frequency, KVA, KWH snd PF (v) Battery charger consisting of Transformer, rectifier, DC volt meter, DC Ammeter, charging rate selector switch (vi)Auto/ manual mode switch (vii) MCB using for indicators & meters (viii) Hooter 24 volt DC (ix)Indicator for both DG & main supply (x) By pass arrangement 36 (b) Engine : Diesel Engine, direct injection, water cooled as per manufactured standard BHP @ 1500 RPM for continous duty of suitable for 15 KVA alternator with provision of 10% over load for one hour in every 12 hour running conforming to BS 5514/ISO 3046 standard, totally enclosed, electric start, compression ignition, 4 cylinder, 4 stroke.The engine shall consists of following specification :- Electrical starter motor 12v DC, Battery charging alternator Turbo charger, pulse tuned exhaust manifold, stainless steel exhaust flexible connectionRaditor cooling with turbo charged after coolingMechanical Fuel injection pumpElectrionic GovernorDual spin-on fuel filterResidential silencerDry type air cleanerShut-off coil with safety for LLOP/HWTFlywheel and housing to suit single bearing alternator(a)Ring spanners - 01 set(b)Screw Driver 5" to 12" - 01 set(c)Cutting plier 9" - 01 No(d)Hammer 2 LBS - 01Note : Rate of cable suitable size for connecting AMF panel to DG set deemed to be included in quoted rate 37 EXTERNAL WATER SUPPLYSupply, laying, jointing and testing of DI (Ductile iron) pressure pipes of size 150 mm dia bore with spigot and socket ends, centrifugally cast, class K-9,with cement mortar lining in inner side as per IS: 8329/2000 (latest revision) and other relevant standards and matallic zinc cozting followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) in any length with inside cement mortar laid in trenches including testing on completion complete all as specified and directed. 38 Supply, laying, jointing and testing of DI (Ductile iron) pressure pipes of size 150 mm dia bore with spigot and socket ends, centrifugally cast, class K-9,with cement mortar lining in inner side as per IS: 8329/2000 (latest revision) and other relevant standards and matallic zinc cozting followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) in any length with inside cement mortar laid in trenches including testing on completion complete all as specified and directed. 39 Supply, laying, jointing and testing of MS ERWpipes of size 200 mm dia bore with spigot and socket ends, centrifugally cast, as per IS: 1239 (latest revision) and other relevant standards and matallic zinc cozting followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) in any length laid in trenches including testing on completion complete all as specified and directed. 40 Supply and fixing of cast iron air valves with two air outlets 50 mm dia bore and fixing up in cast iron water supply mains including testing on completion complete all as specified and directed. 41 Supply, install, test and commissioning self priming centrifugal pumpset 10 HP foot mounted, fan cooled motor suitable for 415V, 3 phase, 50Hz, insulation class F, ambient of 50 C conforming to IS 12615 : 2011, IEC 60034-30-2008 and IP 65 protection, base plate, platform as per manufacturer drg, flexible joint, suction & delivery side complete all as specified and directed 42 Supply, install, test and commissioning self priming centrifugal pumpset 5 HP foot mounted, fan cooled motor suitable for 415V, 3 phase, 50Hz, insulation class F, ambient of 50 C conforming to IS 12615 : 2011, IEC 60034-30-2008 and IP 65 protection, base plate, platform as per manufacturer drg, flexible joint, suction & delivery side complete all as specified and directed 43 Material and labour for installing, testing and commissioning fully automatic soft starter panel for 10 HP submersible , outdoor type , double door , KIOSK type , IP - 55 ,locking arrangement, three phase, 430 V, 50 Hz,suiatble rating semiconductoer fuse, CRCA sheet 3 mm thick metal enclosure, duly powder coated and angle iron frame which is made out of 50x50x6 mm angle iron, factory fabricated cubical type weather proof, copper bus bar with sleeves as per colour coding ,Digital Volt meter and Amp meter , Multifunction meter , Indicator for RYB and ON & OFF , including all electric connection , mounting on floor, civil work, including following protection:-(i) Under voltage & Over Voltage (ii) Under load & Over load(iii) Single phase preventor(iv) phase reversal(v) Earth fault(vi) Short circuit (vii) Unbalanced voltage (Negative phase sequence relay)(viii) Switching surge 44 Material and labour for installing, testing and commissioning fully automatic soft starter panel for 5 HP submersible , outdoor type , double door , KIOSK type , IP - 55 ,locking arrangement, three phase, 430 V, 50 Hz,suiatble rating semiconductoer fuse, CRCA sheet 3 mm thick metal enclosure, duly powder coated and angle iron frame which is made out of 50x50x6 mm angle iron, factory fabricated cubical type weather proof, copper bus bar with sleeves as per colour coding ,Digital Volt meter and Amp meter , Multifunction meter , Indicator for RYB and ON & OFF , including all electric connection , mounting on floor, civil work, including following protection:-(i) Under voltage & Over Voltage (ii) Under load & Over load(iii) Single phase preventor(iv) phase reversal(v) Earth fault(vi) Short circuit (vii) Unbalanced voltage (Negative phase sequence relay)(viii) Switching surge 45 Supply and fixing of cable PVC insulatedcopper conductor flat 3 core 16 sqmm 1100 volt complete all as specified and directed 46 Supply and fixing of cable PVC insulatedcopper conductor flat 3 core 10 sqmm 1100 volt complete all as specified and directed 47 Supply and fixing of foot valve conforning to IS 4038 100 mm diameter including strainer complete all as specified and directed 48 M & L for Construction of new PCC solid Masonary valve chamber of size 450 x 450 x 650 mm (Internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick 150 mm wide off sets alround over 100 mm thick hard core , 200 mm thick PCC solid block walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/Dense soil 3 mm thick MS sheet cover fixed on 50 mm X 50 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coaping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed. 49 M & L for Construction of new PCC solid Masonary valve chamber of size 1000 X1000 X 900 mm (Internal dimenssions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick 150 mm wide off sets alround over 100 mm thick hard core , 200 mm thick PCC solid block walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/Dense soil 3 mm thick MS sheet cover fixed on 25 mm X 25 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coaping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed. 50 Supply and fixing Water level Sensor suitable for 50000 Gln water Capacity Over head Tank Type-Hydrostatic, Range-0-4 Meter Output-4 to 20 Mili Amp complete all as specified by Engineer in Charge. 51 Supply and fixing Water level indicator 7 segment 4 digit LED dis play.Input-4 to 20 Mili Amp.Power Supply-230 Volt AC complete all as specified by Engineer in Charge. 52 EXTERNAL ELECTRIFICATIONSSupply, install, test and commisioning copper wound step down transformer, Level 2 ,outdoor type, including plinth PCC platformcomplete with stranded fittings, ONAN, Vector group DYN11, HT 11 KV, 3 phase, LT, 433 Volts 3 Phase, 4 wire all as per IS 1180 ( Part- I ) : 2014 and designed on minimum 5 star rating with EEL 03, consideration with off load tapings on primary side to vary secondary voltage +/- 5% with taping at every +/- 2.5%of capacity 315 KVA complete all as specified and including the following:- 53 (a) Three Nos porcelain bushings HT 11 KV with bushing rods, nuts and washers inside cable end box . (b) One cable box LV side consisting of 4 Nos porcelain with brass bushing rods, complete with nuts and washers with two nos cable gland of suitable size.(c) Oil conservator with filler type drain valve and oil level gauge.(d) Dehydrating breather with first fill of dehydrating agent.(e) Explosion vents.(f) Thermometer pocket on tank cover.(g) Rating plate and terminal marking plate.(h) The earthing terminal two Nos to tank to faciliate fixing of earth strip. 54 (j) Oil filling hole with cap/plug with connection plate complete.(k) Lifting hook. (l) Oil level gauge and oil drain filter valve. (m) air relief valve plug. (n) Detachable rollers(4 Nos). (o) Initial filling to transformer oil.NOTES:- (i) Contractor shall submit the technical drawing, constructional drawings, safety features drawing etc. for approval of accepting officer.(ii) The contractor shall intimate for factory inspection for routine tests as per IS & ANSIC57.12.90 (latest revision) in the OEM factory in presence of representative nominated by the accepting officer before dispatch from factory, tests after installation shall also be carried by SEI for which GE will intimate through proper channel. (iii) Foundation as per manufacturer design shall deemed to be included in the quated rate. 55 Supply and lay PVC insulated PVC sheather cable , electric control cable with stranded copper conductor of size 2.5 sqmm 2 core 1100 volts grade complete all as specifiedand directed. 56 M & L for cable route indicator shown "HT UG cables" painted in brown colour and root of cable with aero made of CI in suitable eleiptical shape and fixed in MS rod 12mm dia 70 cm long ( all word embosed) and embaded in PCC block of size 30 x 30 x 60cm in ground complete all as specifiedand directed. 57 Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box factory fabricated out door cubicle/KIOSK typetotally enclosed outer cage made out of 3 mm thick sheet metal and inner compartments of 3.0 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and aluminium bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set including connecting the following (Main panel). Note:- Rate of earthwork and PCC work are deemed to be inclusive in this item. 58 INCOMMING(a) Aluminium suitable for 900 Amps = TPN-01 set (b) MCCB 4 Pole thermal magnetic release 415 volts 600 A 36 KA-01(incoming), (c) Digital voltmeter 0 to 500V with selector switch - 01 No(d) Digital Ammemeter 0 to 200 Amps with CT coils and selector switch - 01 No(e) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three) (f) Multi functional meter - 01 NosOUTGOING (a) MCCB 4 pole thermal magnetic release 415 Volts 250 A, 36 KA- 01 (for FP-3)(b) MCCB 4 pole thermal magnetic release 415 Volts 200 A, 36 KA - 01 ( FP - 2)(c) MCCB 4 pole thermal magnetic release 415 Volts 63 A, 16 KA - 01 ( FP - 1) 59 Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box factory fabricated out door cubicle/KIOSK typetotally enclosed outer cage made out of 3 mm thick sheet metal and inner compartments of 3.0 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and aluminium bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set including connecting the following (LT panel No - 1)(a) Aluminium Bus Bar suitable for 200 Amp, TPN - 01 setNote: Rate of earthwork and PCC work etc are deemed to be inclusive in this item. 60 INCOMMING (a) MCCB 4 pole thermal magnetic release 415 Volts 63 A, 16 KA - 01 ( FP - 1) (b) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three)(c) Digital voltmeter 0 to 500V with selector switch - 01 No(d) Digital Ammemeter 0 to 200 Amps with CT coils and selector switch - 01 No (e) Multi functional meter - 01 Nos OUTGOING (a) MCCB 4 pole thermal magnetic release 415 Volts 20 A, 16 KA - 02 ( Guard Room - 1 , Shoping Complex - 1) (b) MCCB 3 pole thermal magnetic release 415 Volts 32 A, 16 KA - 01 ( Meditation Center)(c) MCB SPN 240 Volts 10 A, 10 KA - 01 ( MES Complaint Cell) (d) MCB TPN 415 Volts 10 A, 10 KA - 02 ( Street Light)(f) Digital Timer with contactor - 02 Nos 61 Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box factory fabricated out door cubicle/KIOSK typetotally enclosed outer cage made out of 3 mm thick sheet metal and inner compartments of 3.0 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and aluminium bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set including connecting the following (LT panel No - 2) Note: Rate of earthwork and PCC work etc are deemed to be inclusive in this item. 62 INCOMMING (a) Aluinium Bus Bar suitable for 350 Amp, TPN - 01 set (b) MCCB 4 pole thermal magnetic release 200 A, 36 KA -01 (Incoming)(c) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three)(d) Digital voltmeter 0 to 500V with selector switch - 01No(e) Digital Ammemeter 0 to 200 Amps with CT coils and selector switch - 01 No (f) Multi functional meter - 01 Nos OUTGOING (a) MCCB 3 pole thermal magnetic release 63A,16 KA -04(b) MCB SPN ,10 A , 10 KA -04 63 Supply, installation, testing and commissioning weather and vermin proof L.T. feeder pillar box factory fabricated out door cubicle/KIOSK typetotally enclosed outer cage made out of 3 mm thick sheet metal and inner compartments of 3.0 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and aluminium bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set including connecting the following (LT panel No - 3)(a) Aluminium bus bar suitable for 400 Amps, TPN - 01 setNote: Rate of earthwork and PCC work etc are deemed to be inclusive in this item. 64 INCOMMING (a) MCCB 4 pole thermal magnetic release 415 Volts 250 A, 36 KA- 01 (for FP-3) (b) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three) (c) Digital voltmeter 0 to 500V with selector switch - 01No(d) Digital Ammemeter 0 to 200 Amps with CT coils and selector switch - 01 No (e)Multi functional meter - 01 Nos OUTGOING (a) MCCB 3 pole thermal magnetic release 63 A,16 KA -05 (b) MCB SPN ,10 A , 10 KA -05 65 Supply, installation, commissioning and testing of company makeAutomatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 150 KVAR in 6 steps (50 KVAR fix compensation + 25 KVAR x 2 Nos + 20 KVAR x 2 Nos + 10 KVAR x 1 No ) complete with relays, capacitor banks for automatic operation to power factor above 0.95. The panel should be complete with TP air break contacts of capacitor contacts of duty with suitable swicthgear, MPP heavy duty shunt capacitor impregnatd, having rated voltage of 440 V type with internal electrical swicth gear each element as per IS 13340-1993/IS 13341-1992, IEC 60831 Part I & 2 of outdoor type double door (KIOSK type) complete with interconnections with suitable size of copper wiring, PVC insulated unarmoured cable and PVC sheath etc as required. The panel shall be made out of 3 mm thick CRCA shett powder coated with angle frame of size 50X50X6 mm cubical type including interconnetion wiring, indicating lamps etc confirimng to IP 42 specifications including grounding of panel as per electrical standards, electrical connections shall be made by using proper thimbles/lugs, cable gland complete all as specified and directed as follows:Note: Rate of earthwork and PCC work etc are deemed to be inclusive in this item. 66 INCOMMING (a) 350 Amps 36 KA TPN MCCB, TMD (O/L & S/C release ), Ics = 100 % Icu, positive isolation with stranded extended rotary handle, spreaders, 3 phase barrier, double break contacts, sealable transperant cover on trip unit- 01 No(b) Digital voltameter with primary / secondary PT programmable with selector switch - 01 No(c) Digital ammeterwith primary / secondary CT programmable with selector swicth - 01 No(d) LED indication lamps (RYB) - 01 Set.(e) 5 stage APFCR - 01 No(f) TPN sleeved copper busbar 400A, Neutral busbar shall be capacity (50 KA)-01 set OUTGOING (a) Accessories for 50 KVAR fixed compensation capacitor bank - MCB, TP, 160 Amp, 36 KA.(b) Accessories for 25 KVAR capacitor bank - capacitor duty contactor (AC6b) 63 KVAR with damping resistors which limit xinrush current, 440 volt, 3 ph, 50 Hz, coil-220 lac & MCB TP 20 Amp, 10 KA, D curve. Note:- (a) Ventilating fans of required size to dissipate the heat liberated by capacitor units complete with automatic swicthing ON and OFF of fans depending upon the temperature of panel, 230 V AC, 2650 RPM, 160 Cum/h, flying leads. Panel shall have silicon based fire/heat resistance coating. fire retarding DMC/SMC filling for the opening around the busbar near to the sectional barriers and door interlocking for all compartments - 01 lot. All Accessories pre wired with suitable size copper conductor cable insulated with fiber glass insulation to with stand. (b) high temperature, housed in cubical panel (CPRI approved) made out of 3.00 mm thick MS sheet factory made duly powder coateed front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer. 67 Supply and fixing pole mounted thermoplastic cable junction box for street light with IP-66 protection, halogen free and weather proof with metric knockouts for cable entry for outdoor installation of size 200mm x 160mm x 98mm with front door opening system including terminals for one incoming and two outgoing cables of size 16 sqmm 4 core, one MCB SP 3 to 6 Amp 240V AC with mounting clamp of flat iron, nut, bolt and washers complete all as specified and directed
|