Providing And Fixing Of Facade Lighting Arangement In Sector-94 Underpass And City Center Underpass, Noida - SITC of Outdoor Architectural 1200mm LED Non Integral Linear Wallwash luminaire with System wattage not more than 30W, System efficacy =45LPW, CCT RGBW (W=3000K) with 4in1 LED chip for uniform illumination ensuring every LED in Luminaire reproducing same color at all time, System lumen output should not be less than 1800lm(±10%) with all RGBW channels ON, Fixture should be compatible with DMX512 and able to reproduce 16Million Colors with 256Step Dimming, Fixture should be compatible with Non-Integral 24V DC CV Driver Placed in IP Rated Box , Single piece Housing made of Extruded Aluminium with Aluminium End caps ensuring optimum thermal management, Heat Resistant Clear tempered Glass with Secondary PMMA lens with Available Precise Beam angles 10°X30° . Ingress Protection = IP66 with Impact Resistance = IK05. Remote type Driver should be high efficiency isolated constant voltage driver with Protection Class 1. Fixture should have inbuilt 4 channel decoder. Total Surge protection of 6KV Internal & 20KV or More Additional SPD, No-load protection, Over voltage protection, & Short circuit protection, Life 60,000 B Hrs@L70, CRI>80 (for While LED), THD<10% , PF>0.95, Voltage Range 140-270V AC, Operating Temp 0 to +50°C, Operating Humidity 10-90%, Fixture weight should not be more than 3KG (±5%) to avoid excessive load on facade structure. Fixture should come with min. 0.5Mtr. long loop in loop out cable with =IP66 connector, Light Engine PCB should be Metal Core PCB made of high grade Al 5052 with =70 micron copper thickness & 2 W/mk thermal conductivity for better life & thermal maintenance for light Engines. Manufacturer emblem/logo embossed into the Aluminium housing/End Caps to allow OEM identification & traceability till the life of the fixture. Suitable for mounting on surface using inbuilt mounting brackets with >180° tilt adjustment at site . Contractor should make necessary provisions for proper installation of 2 luminaires at site with exceptional workmanship considering all safety standards. Luminaire Dimensions for ref. L=1200mm, W=60mm(±5%), H=60mm(±5%) .Manufacturer should have BIS with R No. , LM79 from NABL Accredited Lab, TTC from NABL Accredited Lab, LM80, Photometric & illumination Code Diagram, Technical Data sheet soft copy for submission if requested by Engineer in-charge. Fixture should have Silver Grey/Black (As per selection by Engineer In-charge) Nano technology powder coating , Luminaire should comply with Performance & safety standards IEC 60598/ IEC60950 , IEC 60529, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015Make: Color Kinetics/LT/ Unilamp/Traxon/ Thorn ) Complete in all respects as per direction of E/I 3 SITC of Outdoor LED System wattage not more than 80W, System efficacy>100LPW (±5%), CCT=3000Kfor uniform illumination ensuring every LED in Luminaire reproducing same color at all time. Fixture should have Integral Driver Fixture should be compatible for DMX512 .Housing should be extruded Aluminium alloy ensuring optimum thermal management , Fixture should be available in diffused optics wi (As per approved concept & Site requirement). Secondary Lens should be of PMMA material & covered with Heat Resistance Toughened Glass / PC cover, Ingress Protection should not be less than IP66, Impact Resistance should be IK08 or more. Total Inbuilt and Additional Surge protection of more than or equal to 6KV Internal + 20KV Additional SPD along with other necessary protections No Load protection, Over voltage protection, Short circuit protection. LED Life should be 50,000 B Hrs@L70 B10, , PF>0.95, Operating voltage range 140-270V AC, Operating ambient Temp 0 to +50°C, Operating Humidity 10-90% Powder coating should be corrosion resistant Nano technology powder coating in Silver grey colour. Standard Power cable should have IP67 connector. Technical Data Sheet, Type test Certificate from In-House NABL accredited Lab should be submitted on request. Manufacturer/OEM emblem/logo should be embossed into the Aluminium housing to allow identification of OEM & traceability till the life of the fixture. Manufacturer/OEM should have complete manufacturing set up in India with In-house capability of Housing, PCB & Driver Manufacturing and In-House NABL Accredited LAB for Electrical & photometry testing. Luminaire should comply with Performance & safety standards IEC 60598/ IEC60950 , IEC 60529, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015 4 Supply, installation, testing & commissioining of Universe (1024 Channels) DMX controller with following features & specifications: This is built on the latest generation of lighting controllers and combines all recent innovations. Designed for DIN rail mounting, this is the perfect solution for midrange lighting installations. Delivered with 1024 DMX channels.The lighting levels, color and effects can be programmed from a PC, Mac, Android, iPad or iPhone using software from our website.Its Key Features includes • DMX Stand Alone controller • Up to 2 x DMX512 universes (1024 channels) • RDM compatible • USB & Ethernet connectivity for programming/ control • Stand Alone mode with 99 scenes • Play scenes in 5 areas / zones • microSD slot • 8+3 dry contact trigger ports • Test scenes rotary switch • Windows/Mac software to set dynamic colors/effects • iPhone/iPad/Android remote and programming apps • cloud ompatibility.Technical Data Input Power 12v DC (8-15V range), Output Protocol DMX512 , Programmability PC, Mac, Android, iOS, Connections-USB-C Ethernet Screw terminals for DMX / RDM Universes, 8+3 Contact ports, 12v power-in Battery holder (CR2032), microSD slot Memory SD Card ,Environment IP20 / to 0 to +50°C, Buttons Rotary switch ,OS Requirements Mac OS X 10.8-10.14 Windows 7/8/10 Standards CE, ETL, Low voltage, EMC, and RoHS compliance with 5 year waranty complete in all respect as per direction of E/I. Make: Color Kinetics/LT/ Unilamp/Traxon/ Thorn ) Complete in all respects as per direction of E/I 5 Programming & Commisioning Charges of above all Lights with different Scenes complete in all respect as per approved by Noida officials 6 Supply, installation, testing & commissioining of 3port DMX Splitter(Din rail Mountable)with following features & specifications: DMX signal splitter enables branching in complex DMX installations. The combination of a large number of receivers in series can be troublesome, therefore it was possible to create branching DMX tracks using a splitter.With Splitter, it possible to split the DMX input signal into 6 independent branches. The individual outputs are galvanically isolated from input and between each other. The output signals are appropriately reinforces, which guarantees correct operation of the entire installation. DMX Splitter is manufactured in a housing adapted for mounting on standard DIN 35mm rails. Specification - Power Supply-DC12- 24V,DMX Channels--512,Nos. of DMX Inout-1 & output-6,Optical Isolation of DMX Lines,Built-in Terminatior,breakdown voltage of the isolation>1000V,current consumption-<500mA with 5 year waranty complete in all respect as per direction of E/I. 7 Supply, installation, testing & commissioining of 2 port DMX Splitter(Din rail Mountable)with following features & specifications: DMX signal splitter enables branching in complex DMX installations. The combination of a large number of receivers in series can be troublesome, therefore it was possible to create branching DMX tracks using a splitter.With Splitter, it possible to split the DMX input signal into 6 independent branches. The individual outputs are galvanically isolated from input and between each other. The output signals are appropriately reinforces, which guarantees correct operation of the entire installation. DMX Splitter is manufactured in a housing adapted for mounting on standard DIN 35mm rails. Specification - Power Supply-DC12- 24V,DMX Channels--512,Nos. of DMX Inout-1 & output-2,Optical Isolation of DMX Lines,Built-in Terminatior,breakdown voltage of the isolation>1000V,current consumption-<500mA with 5 year waranty complete in all respect as per direction of E/I 8 Supply , Installation , Testing & Commissioning of 4 core .5 sq mm DMX Cable Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single corecable in surface/ recessed medium class PVC conduit as required 9 Operation and Maintenance of above all lights, controller, splitters and other all equipments installed by working agencies including replacing of defective lights and other parts, changing of design and defect Libeality period with theft liabelity also complete for 2nd year. 10 Operation and Maintenance of above all lights, controller, splitters and other all equipments installed by working agencies including replacing of defective lights and other parts, changing of design and defect Libeality period with theft liabelity also complete for 3rd year. 11 Supply and laying of 40 mm dia heavy duty (2mm thick) PVC conduit complete with bends and other acessories as required and 14 SWG fish steel wire etc. in slab alongwith reinforcement, before concreting and plastering etc. complete in all respects.P.S No. 284(A). 12 Supply and laying of 25 mm dia heavy duty (2mm thick) PVC conduit complete with bends and other acessories as required and 14 SWG fish steel wire etc. in slab alongwith reinforcement, before concreting and plastering etc. complete in all respects.P.S No. 282(A). 13 Supplying and laying of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. Clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respects. the armouring of the cable shall be properly connected with the earth conductor by clamps etc.(Grandlay, Skytone,Gloster, KEI, Havells make) 14 (1) 4 Sq.mm. x 4 Core(PS No. 501) 15 (2) 6 Sq.mm. 4 Core(PS No. 501) 16 (3) 25 Sq.mm. 3.5 Core(PS No. 501) 17 (4) 50 Sq.mm. 3.5 Core(PS No. 501) 18 S/F of Palm or Pin type copper tin plated cable socket (lugs)to the cable lead insulation with tape and making connections complete as per direction of E/I. P.S. No. 504 19 1- 4 sq. mm 20 2- 6 sq. mm 21 3- 16 sq. mm 22 4- 25 Sq.mm. 23 5-50 Sq.mm. 24 S/Laying of90 mm dia (OD 90 mm & ID 76 mm nominal) size of (DWC) HDPE Pipes ISI marked along wigh all accessories like socket, bend, couplers etc. conforming to IS 14930, Part-II complete with filling and cutting, jointing etc. direct in ground ( 75 cm below ground level) including excavation and refilling the trench pat excluding sand cushioning and protective covering etc. Complete in all respects. Rex/Duraline/Time/CPE make. as per DSR 2016 item no. 14.16.2 page no. 49 25 Supply and fixing of 40 Amp TPNcapacity of automatic street light cubical control panel painted with anti corrosive alkali and acid proof paint crossing of time switch TSO 100 series with contractors, HRC fuse, isolating swtich metering instrument & instrument box with CTs etc. in case of TPN, Complete in all respects. as per PS No. 807f 26 Supply and buring of safe earthing electrode T-19 (Hot dip galvanized), length up to 2000mm outer type 50mm, inner pipe, 22mm terminal dia 12mm, outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip galvanization up to 100 micron filled with crystalline conductive mixture(CCM) having anti corrosive & conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good micture of retaining capicity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25x3 G.I. strip will be extra as per PS No. 725A 27 Supply of Steel Tubular Pole 11 M long designated 410-SP-56 . complete in all respects as per direction of E/I. .(UPERC P-30) 28 Errection of metallic pole of following length in cement concrete 1:3:6 ( 1cement:3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required above 10.0 mtr and upto 12 mtr (Electrical DSR 2018 I. n. 11.3.4) 29 Supply and erection of overhead line with ACSR Conductor (Dog & Raccoon) poles / service bracket including binding etc.complete in all respects. P.S. No. 627 30 Painting of the electric pole with 2 Coats of aluminium paint over red oxide primer complete in all respects. P.S. No. 634 31 Supplying of channel iron 75mmx40mmx6mm(7.14 Kg Per mtr) pole top bracket/cross arm for single 11 kV overhead line conductor complete with 50mmx6mm flat iron clamp, bolts, nuts and washer including drilling holes for insulator pins bolts and nuts etc, and painting with primer and finish paint as required (Electrical DSR-2018 item no. 13.2 pg.44) 32 S/E of straight MS Channel 50x100 mm. (9.2 Kg/M) 2.60 M long as per design with required clamps made of M.S. flat of size 50x6 mm. with nut & bolts etc. as per direction of E/I. .((UPERC P-30) 33 Supplying and erection of 11kV pin insulator complete with large steel head G.I. Pin, nuts & washer etc. as required (DSR-2018 item no. 13.10 pg.46) 34 Supplying and erection of 11kV Disc insulator for 11kV overhead line with galvanised inculator fitting, ball and socket type and complete with galvanised strain clamp, bolts, nuts& washer etc. as required (DSR-2018 item no. 13.11 pg.45) 35 S/F of 11 KV TPMO Relco/Rama/Azad make 9 Nos. insulator of Jai shree/BHEL/ Rama/ Rastriya make complete in all respects as per direction of E/I.(UPERC page no. 48) 36 S/F of out door type 11KV fuse set Relco/Rama/Rastriya make with insulator Jai shree/BHEL make complete in all respects as per direction of E/I..(AOR) 37 S/E Testing & Commissioning of 63 KVA Al. wound outdoor type Transformer as per ISS. Complete in all respects Make : P.M./Kanohar/LD Power/Paramix as per direction of E/I..(RESPO page no. 51) 38 Supply & erection of overhead line with G.I. wire no. 8 to 4 SWG on poles/serivce bracket including binding etc. complete in all respect. as per PS No. 628 39 Supply and burrying of 75 mm Dia 3 Mtrs. Long Electrode casted with maintenance free, conductive concrete, non corrosive mixture ( Ultra low Resistive carbon 0.001 ohm/Mtr) in the ratio of 3:1:1 (marconite : cement : water) on M.S. Rod wiih hole (16 mm diameter X3 Mtrs ) will be vertically installed for earthing with 1 Mtr G.I strip (25 mm X 2.5mm) connected with SS nut bolt. The earth electrode will be installed into the 100 mm pit up to 3000 mm depth. noraml soil will be used as backfill material.t. as per PS No. 729C 40 Supply of 185sq. mm 3 cofehigh conductivity aluminium strand compacted circular conductor XLPE armoured 11 KV Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment at a depth of 900 mm. below ground level over a cushion of 100 mm. thick sand around and protect with brick on sides and top of cable shall be properly connecting with the earth conductor by clamps etc. with the cost of all material, labour, T&P etc. required for proper completion of the work. (CCI/ Gloster/ ICL/ Grandley/ Havells/Diacab/KEImake)(UPERC 2019 Pg-28) 41 Laying of One number PVC insulated and PVC sheathed/ XLPE power cable of 11KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.(DSR elect 2018 Item.N.8.3.2/P31) Above 120 Sqmm and upto 400 Sqmm 42 Supplying and making 185 sq. mm outdoor cable type 11KV Jointing kit Heat shrinkable type for 11 KV Cable including cost of all material, labour, T & P etc. for proper completion make (Rahychem/Denson/Casseal as per direction of UPERCP 26) 43 S/Laying of heavy density poly ethylene pipes ISI marked anti rediant grade OD 160mm dia PN-8 PE 100 (PE 400) grade as per IS code 4984 with excavation at a depth of 1.20 Mtr below ground level i/c the cost of cutting of pipes for making up to length and making joints complete all respects as per direction of E/I. (creator poly extrusion/duraline/rex/times/ naranderplast/pioneer make). (AOR) 44 S/F of 6 dia G.I. pipe B class for cable duly duly clamped with support by 1 no. with clamps for 20x3mm MS flat, bolt, nuts and washer required for proper completion of work (UPERC P-47) 45 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer over the plasterwd wall surface to prepare the surface even and smooth completed. burzer, JK, Birla or Similar make (AOR) 46 Finishing wall with acrylic smooth exterior paint of required shade . New work two coat or more applied @ 1.67 ltr per 10 sqm over and including priming coat of exterior primer applied rate @ 2.20kg per 10 sqm(SOR) 47 Repair of plater of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting patches in proper shape, raking out joints in preapring in plastring. The wall surface with white cement base polymer modified self curring mortar, including disposal of rubbish all complete as per direction of E/I (SOR) 48 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. 49 Providing and laying of200mm dia 6mmthickness through trenchless method including jointing of pipe, excavation of thrust pit and receiving pit of required size with all T & P and the excavation & back filling with compaction complete as per specification for road crossing by H.D.D machine method pipoe will be installed at minumum depth 2M to 3 m below the ground surface or downward as per site condition in required slope.(AOR)
|