Tender For Civil, Electrical And Mgps Works For Renovation Oficu - Govind Singh Govt.Hospital, Ranikhet; 1 CIVIL WORKS 2 PAINTING 3 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 4 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 5 Finishing with Deluxe Multi surface paint system for interiors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm 6 FRP DOOR 7 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 8 Providing and fixing to existing door frames. 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 9 PLUMBING 10 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 11 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour. 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. 12 Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. weighing not less than 105 gms. 13 CURTAIN WORK 14 Window & Door Curtain fabric weight shall be up to 250-275 (±5%) gsm Composition of fabric shall be polyester yarn I.E. 300 denier fast colour sink age shall be (±5%) Weft and warp shall be polyester / cotton polyester mix Rate quoted for fully stitched Curtain with top nepha with punch holes after lining bucramreinforced with SS / PVC islets and lower nepha 200mm double turned 15 Providing and fixing of vertical/roller blinds width 100 mm regular quantity made from 100 % polyster/Fibre yarn coated with fade resistant polymer to ensure complete opaquety with zero light transmittance, having suitable coating on exterior, including all fixtures and fittings complete in all respect as per design and instruction of Engineer in-charge and as per site conditions. The colour will be approved by the competent authority Make-MAC/VISTA/NOVA or any equivalent make. 16 FURNITURES 17 Providing & Fixing mid back chair .The seat & back are made up of 12mm thick hotpressed plywood, upholstered with fabric & moulded with Polyurethane foam seat and back covers. The back foam should designed with contouredlumbar support for extra comfort .The seat has extra thick foam on front edge to give extra comfort.Mid back size 475 mm Width x 580 mm Height mm. And seat size 470 mm Width x 480 mm Thepolyurethane foam should bemoulded with density = 45 kg/m3 and hardness = 16 +/2 kg on hampdem machine at 25% compression .Armrest are injection moulded from black copolymer polypropylene. The mechanism should befixed 360 degree revolving type,Upright position locking, tilt tension adjustment, seat back tilting ratio 1:3. The pneumatic height adjustment has an adjustment stroke of 12 cm. The pedestal should be injection moulded in black 33 % glass filled in nylon 66 with 5 nos twin wheel castors. The pedestal should be 66.3 cm pitch-center diameter. 18 Providing & Fixing normal chair .The seat has extra thick foam on front edge to give extra comfort.Mid back size 475 mm Width x 580 mm Height mm. And seat size 470 mm Width x 480 mm Thepolyurethane foam should bemoulded with density = 45 kg/m3 and hardness = 16 +/2 kg on hampdem machine at 25% compression .Armrest are injection moulded from black copolymer polypropylene. The mechanism should befixed 360 degree revolving type,Upright position locking, tilt tension adjustment, seat back tilting ratio 1:3. The pneumatic height adjustment has an adjustment stroke of 12 cm. The pedestal should be injection moulded in black 33 % glass filled in nylon 66 with 5 nos twin wheel castors. The pedestal should be 66.3 cm pitch-center diameter. 19 Providing & Fixing 3 seater stainless steel chair. Silver colour with seating capacity 3 SS 201 grade (or better) steel perforated seat sheet and back rest and arm rest. Suitable for heavy public use. Should be ISO certified manufacturer. Width of seat 52cm to 55cm, height from ground 79cm. 20 Providing and fixing in position U shaped NURSING STATION unit with granite top of size 4000X600X1200 MM as per the approved drawing made up of 18 mm thick Marine Plywood conforming to IS:710 both side laminated top ,bottom, side, shelf ,vertical , skirting , drawer facia ,drawer back , drawer side etc.. with 18 mm thick door and 9 mm thick both side laminated drawer bottom and back panel including necessary approved hinge, telescopic slide ,multipurpose lock ,hanger rod of 25mm dia 16 gauge nickel plated MS Pipe ,2nos. tower bolt of barrel type having size 150 x 10mm, 4 nos. magnetic catcher triple strip vertical type of approved quality, 128 mm handle , kd/minifix fitting, edges to be sealed with PVC edge bending tape 2.00 mm thick of approved brand fixture and finishing etc.. complete job. as per approved shade and colour and as per Architecture drawing and Engineer in Charge. . 21 ELECTRICAL WORKS 22 Wiring through PVC conduit 23 Wiring for circuit/submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.(Make:Havells/Finolex/V-guard/Polycab)2X1.5 sq.mm + 1X1.5 sq.mm earth wire 24 Wiring for circuit/submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.(Make:Havells/Finolex/V-guard/Polycab)2X2.5 sq.mm + 1 X2.5 sq mm earth wire 25 Telephone wiring in existing conduit: 26 Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair 27 Modular boxes, bases & cover plate: 28 Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.3 module 29 Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.6 module 30 Modular type switch/socket: 31 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 5/6 Amps switch 32 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.3 pin 5/6 Amp socket outlet 33 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.15/16 Amps switch 34 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.6pin 15/16 Amps (universal) socket outlet 35 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.Telephone socket outlet 36 S/F PVC conduit: 37 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(ISI Make)25 mm 38 S/F OF SP MCB 39 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.6/32 A SP MCB 40 EARTHING 41 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. 42 S/F of TPN RCBO 43 Supplying and fixing following rating, four pole, (three phase and neutral) 415 volts RCBO, having a sensitivity current upto 100/300 milliamperes in the existing MCB PDB complete with connections, testing and commissioning etc. as required.(Make: Legrand/Havells/HPL)63 A 4P RCBO 100mA 44 Supplying and fixing following rating, four pole, (three phase and neutral) 415 volts RCBO, having a sensitivity current upto 100/300 milliamperes in the existing MCB PDB complete with connections, testing and commissioning etc. as required.(Make: Legrand/Havells/HPL)32 A 4P RCBO 100mA 45 Supply and fixing of single phse 240 V Calling bell with its all accessories 46 Supply, installation and fixing of Corded Landline Phone with caller ID and speaker phone 47 Supply and installation of Co2 Fire Extinguisher (Trolley Mount - Wheel Operating) Type 4.5KG with MS clamps etc. for fixing on wall/wooden partition with 01 year warranty. I.S. No. 13849. 48 MGPS Works 49 Replace all the damaged outlet valves, Zone valves 50 Oxygen Manifold: Middles and bottom frames of the cylinder bank shall be provided to fit both round and flat bottom cylinder safely plant size oxygen 10+10 Oxygen cylinder manifold. 51 The existing Vacuum/Air compressor units shall be installed properly on metal frame on PCC platform. Appropriate size of Air dryer for compressed air shall be supplied and installed working pressure 15Kg/cm2 , Dew point: 40 degree 52 Drain valves with piping shall be provided in the vacuum receiver tank capacity 1000 litters, Receiver Type:-Vertical type with inlet, outlet and Drain provisions(valve) 53 Vacuum Bacteria FilterA bacterial filter would be fitted between each pump and the reservoir, which have replaceable elements and 6 each shall be capable of passing the total design flow. The filters would be arranged such that one filter can be taken out for servicing without interrupting or restricting the vacuum service as a whole. The filters would have a penetration not exceeding 0.05% when tested by the sodium flames test in accordance with BS 3928. Moisture traps would also be fitted on each leg. These may be combined with the filter units. The traps would have removable transparent drain bowls which can be removed without affecting plan operation. The bowls would be serializable by using moist stream at 2.2 bar and 138 degree Celsius in porous load sterilizer.Ensure that all copper piping’s shall be properly installed and clamping/saddles shall be provided as appropriate places Ensure that all the copper pipings shall be properly installed and clamping/saddles shall be provided as appropriate places. 54 Additional isolation valves of Appropriate size of the pipe for Oxygen, Air and Vacuum shall be installed maximum of 55 Suitable sized vertical DB with incomer as isolator and RCCB, Outgoing as TP MCB should be provided 56 Suitable sized incoming cables for vertical DB 57 Suitable sized outgoing cables for 4 nos of 5 Hp motors and 2 nos of Dryer unit 58 DOL starter should be placed in appropriate frame. The earthing of the electrical installations shall be checked and ensure the resistance as per IEC standards 59 Should be supplied necessary LED lights and power socket with proper wiring and Suitable sized MCBs. 60 The flooring of the plant room shall be renovated with appropriate thickness of PCC and plastering to remove cracks 61 Should be supplied IV stand.
|