Tender For Construction Of Guard Room, Main Gate & Fencing In D.C Residence In Revenue Colony, Rohtak.; 1 Earth work in excavation in foundations, trenches, etc. in all kinds of soils, not exceeding 2 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30 meters. (HSR 6.6) 2 Cement concrete 1:6:12 with stone aggregate 20 mm nominal size in foundation and plinth. (HSR 10.33) 3 Cement concrete 1:1-1/2:3 with stone aggregate 20 mm Nominal size for reinforced concrete work for walls exceeding 20mm thickness (straight and curved) beams, girders, stairs, columns, (square or rectangular ) battens and lintels etc. excluding steel reinforcement but including centring and shuttering , laid in position ,complete in all respects (HSR.10.86+10.95,a) 4 Cement concrete 1:1-1/2:3 with stone aggregate 20mm Nominal size for reinforced concrete work in footing, strips, foundations, beams, rafts, pedestals and approach slabs of bridges etc.excluding steel reinforcement but including centring and shuttering ,laid in position ,complete in all respects (For work upto 1.5 metres below ground level).(HSR 10.90+10.95,a) 5 First class brick work laid in cement sand mortar1:4 in foundation and plinth. (HSR.11.4) 6 First class brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level(HSR.11.9) 7 12 mm thick cement plaster 1:4 on walls (HSR 15.5) 8 15 mm thick cement plaster 1:4 on the rough side of single or half brick wall (HSR 15.10) 9 Applying pink primer or aluminium priming coat on wood work including preparation of surface, knotting and stopping etc. (HSR 16.2) 1st quality 10 Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 16.3) 1st quality 11 Applying priming coat with metal primer on new steel or iron work including preparation of surface. (HSR 16.9) 1st quality 12 Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surfaces. (HSR 16.25) 1st quality 13 Providing two coats of exterior acrylic emulsion paint. ( HSR 16.79) 14 (b) 1st quality 15 Providing and applying two coats white cement based putty over plastered surface and grinding the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material labour charges scaffolding sundries etc. complete (J.K/Birla make)(HSR 16.81) 16 Wrought iron and mild steel (using angles, flats, square bars, tee and channels) ladders, grills, gratting frames, window guards, iron doors openable or fixed staircase or parapet or any other type of railing, gates and tree guard etc., including cost of screws and welding rods or bolts and nuts complete fixed in position. (HSR 18.12) 17 Steel reinforcement TMT bars FE-500 EQR / FE-500 D grade or more for RCC work, where no included in the complete rate of RCC including straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position complete in all respects for all heights/depths/storeys/basements etc. (HSR 18.22). Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps.From the length so measured, the weight of reinforcement shall be calculated in tones on the basis of IS:1732.Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing, shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 18 N.S ITEMS CIVIL WORK 19 Providing and fixing of round barbed wire fencing and five nos. straight wire i/c providing and fixing 35x35x5mm MS angles @ 9 feet centre to centre complete in all respect.(N.S) 20 Providing & fixing 8mm thick ultra deziner cement bonded particle ply termite proof, fire resistant, moisture resistant (ISI 4276-1995) and (62%, cement, 28% wood, 10% chemicals) including all accessories and labour complete in all respect.(N.S) 21 Providing & fixing 12mm thick ultra cement bonded particle ply termite proof, fire resistant, moisture resistant (ISI 4276-1995) and (62%, cement, 28% wood, 10% chemicals) including all accessories and labour complete in all respect.(N.S)
|