Bids Are Invited For Customized Amc/Cmc For Pre-Owned Products - Procurement And Supply Of Digital Radiograp ... in India
Tender Notice
TenderID
88754406
Tender Brief
Bids Are Invited For Customized Amc/Cmc For Pre-Owned Products - Procurement And Supply Of Digital Radiography System Along With Turnkey; --; Comprehensive Maintenance Contract (Cmc); Not Applicable; No 1. X-Ray Machine A. Machine: 1 Completely Int
Bids Are Invited For Customized AMC/CMC for Pre-owned Products - PROCUREMENT AND SUPPLY OF DIGITAL RADIOGRAPHY SYSTEM ALONG WITH TURNKEY; --; Comprehensive Maintenance Contract (CMC); Not Applicable; No 1. X-ray Machine A. Machine: 1 Completely Integrated (integrated generator and Image acquisition) Digital Radiography system suitable for radiography application for Veterinary purpose 2 Do all the general radiological applications on table (Small Animals) and Detector stand for Large Animal X-Ray on standing position. 3 High frequency Digital Radiography system with rotating anode X-Ray tube, 3D ceiling suspended stand with manual movements & Detector stand with inbuilt fixed FPD. B. High frequency generator: 1.Latest technology Generator with HT tank and of high frequency 40 KHz or more. 2. Automatic exposure control for constant power output with minimum 80 kW or higher. 3 KV range should be 40KV-150KV in IKV/step, mA output should be 1000mA, 800 mA @ 100KV, should have overloading protection. mA range should be from 1 mA to 500mAs. C. X-Ray Tube: 1. A Dual focus Rotating Anode X-Ray tube. 2. Focal spots of tube should be: small focus 0.6 and Large focus 1.2 3. Large anode Heat storage capacity of 300KHU or more. 4. Collimator: Geared manual collimator with LED light source with high LUX output. 5. HV Cable: 1 Pair of HV Cable of suitable length. D. Tube Stand: 1. Ceiling mounted stand with 3D manual movements of the tube head covering a huge area. 2. Manual movement in longitudinal and transverse & Motorized Vertical movement controlled from panel mounted on Tube collimator assembly. 3. Tube stand with actuator based/telescopic noiseless swift motorized up/down movement. 4. Tube head Rotation (along vertical axis): ± 18. E. Table for small animals: Mobile diagnostic table should be provided. 1. Dimensions: 1900mm or more Length, 660mm or more Width and 721mm or Less Height. 2. Locks available on front wheels for table stability during exposure. 3. Maximum weight bearing capacity for the table-180 Kg. F. Detector stand on railings: Floor mounted detector stand should have Flat Panel Detector for lung and skeleton X-Ray examinations, éser friendly design & handling. 1. Detector stand have provision to do chest radiography with and without grid. 2. The bucky rotation movement of Panel detector 0-90. 3. Longitudinal movement: >1850mm. G. Flat Panel Detector (Singlr detector for Detector stand): 1. Flat panel type Detector with A-Si (Amorphous Silicon) and Csl (Caesium Iodide) as scintillator. 2. Size of detector: 43cm x 43cm 3. Active image matrix: 3K x 3K. 4. Image depth 16bit. 5. Panel size should be 139um. 6. Detector resolution: 3.3 lp/mm. 7. DQE (Detector quantum Efficiency)- more than 65%. 8. 01 No. additional detector fitted in protective cover for doing lying down X-rays of animals. H. Operating Station/Work Station: X-Ray Image control console with fully integrated system with following features: 1. Digital Display of KV & mAs. 2. KV & mAs increase & decrease control on Graphical User Interface (G.U.I.). 3. Ready and X-Ray ON indication on G.U.I. 4. Self diagnostic program which can diagnose and display error messages such as KV error, Filament error & Tubes Thermal Overload. 5. Anatomical Programming Radiography (i.e. APR): Preprogrammed parameters of body Anatomy which helps the user to select exposure parameters based on body parts, examination view and size of the animal. It should be computer based system (full system integration), so any number of Organ Programming combinations is possible. User can define his own Organ Parameters and can edit the existing parameters to the satisfaction and comfort level. 6. A 2-step hand switch with dual action for exposure release with retractable cord should be provided for taking images from a safer distance. 1. Image Acquisition Software: Software Characteristics (should be from the same manufacturer): 1. Software provided complete control of all image capture functions within the examination room. It enhances the entire workflow by delivering diagnostic image instantly. It also allows user to transfer X-Ray images electronically to remote workstations, image archives, and printers, also has an excellent performance on image quality control such as: Main Features Digital image processing technology Preview image in less than 5 seconds. Exam specific Algorithms image processing for consistent image quality of all body parts. Present image processing tools for different anatomy Image cropping Image mirror, rotate. Image annotation Add image accept/reject comments Rejected images achrival with provision of converting them to Accepted images. Separate log for Rejected, Accepted and Printed and Veterolegal images. True size for printing. Hard disc capacity for image storage>3000 images. Inbuild CD/DVD/Flash Drive Writer facility. Excellent Maintainability Remote online system diagnosis Remote online software upgrade Image quality control tools Easy and quick Offset and gain calibration with bad pixel removal algorithm. Full DICOM 3.0 Compatibility Get DICOM work list DICOM Print DICOM store Support DICOM MPPS Workstation along with monitor: 1 No. 19 LCD/TFT monitor provided. J. Power supply requirement: 1. 3 Phase, 400 Volts AC 50Hz with line resist 0.2 Ohms. Line Regulation ±10% 2. Suitable rating UPS for the software system should be provided. 3. Servo Voltage Stabilizer of Suitable rating for complete to be provided. 4. Lead Glass of Size 3*4 Ft. Acessories:- 5 Nos. Lead aprons of 0.5 MM lead equivalence and 3 fold lead protection barrier. 2 Digital Radiograph y System 1. The system should have online UPS for Console Workstation software and printer with minimum back up time of 30 minutes. 2. It should have complete processing unit including 19 HD monitor and all relevant software for radiographic use of Veterinary purpose 3. One additional CPU with Graphic and video card along with HD monitor 21 for acquiring the X-ray Images and interpretation along with UPS should be supplied. 4. The system should have storage disk of 1 Tera byte or more, 5. Networking for the unit with main reporting room along with ready DICOM interface and networking capability with PACS/RIS/HIS System should be provided. 6.1 No. 2 tray dry Chemistry Camera Printer should be supplied with the machine. 7. The unit should be as per AERB safety standards. 8. The X-ray machine should have wireless flat panel X-ray detector which should be able to do all routine radiography examination. 9. Minimum pixel should be 140 micron or less. A/D conversion of 16 bits minimum should be present. 10. The detector should have ingress protection of IPI or better. 11. System should be supplied with DR protective sleeve for use in large animals such that the panel is protected and does not get damaged while placing it under recumbent large animal. 3. Instructions and regulatory approvals 1. The main unit must have USFDA/European CE approval form a notified body 2. Company should have previous record of similar or same unit in Veterinary/Government institutions in state of Punjab or Northern India. 3. The company/firm should not be blacklisted/debarred either in Government Departments/Agencies in State of U.T., Chandigarh, Any State or Central Government Department/Agencies etc. as on the date of submission of the bid in the present tender. 4. Company should provide list of installations along with supply order, customer contact details. 5. Company must submit original catalogue and product data sheet conforming specifications along with the tender. 4 Installations. Warranty. CMC. etc 1. Company should have service center in Punjab/Chandigarh/North India, please furnish details. 2. Complete unit should have comprehensive warranty of 2 years 3. Complete transportation, delivery, installation (including laying of HT cables, if any) and commissioning, handing over shall be done by the firm. 4. Firm must quote comprehensive Maintenance contract ( CMC) price of post warranty period for the next 3 years. 5. Complete formalities for procuring the AERB permission and ready to use licenses will be firms responsibility after receiving the order. 6 QA certification after every two years will be firms responsibility in warrantee and CMC period. 7 Training to the staff is to be provided after installation.5 Turn key work 1. Any civil and electrical work to install the machine will be responsibility of the supplier. 2. Firm shall also be responsible to modify the assigned area for installation of 1000 mA large animal X-ray machine as per requirements of radiological safety guidelines. 3. Lead glass 3x4 Ft should be supplied with the machine and its installation will be firms responsibility. 4. Lead lining work for doors and windows is to be done by firm. 5. The firm should provide adequate Air Conditioners for maintaining the ambient temperature in the X-ray exposure room and console room 6. The firm should provide rubber padding for the floor of X-ray exposure room. 7. The company have right to visit the site before quoting the tender under approval of the Medical Officer of Health, Municipal Corporation, Chandigarh 8. The supplier should ensure that the above said equipment is ready to use without any additional financial liabilities. 6 Accessories 1. The Machine should be supplied with a Lead Aprons -5 nos b Thyroid shield-2 nos C Gonad Shield-2 nos dLead Gloves-2 pair e Lead Google-2 nos., of reputed brand. 2 The lead lined items are to be supplied after the approval from-Commissioner Municipal Corporation Chandigarh Total Quantity :
Contact Information
Other Detail
View Original Notice/Document
Oops !! Document too Old so now not available !!
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 88754406
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.