Second Tender For Supply Of Orthopedics And Dental Implants Second Tender For Supply Of Orthopedics And Dental Implants In Dr. Lnp Gmc Ratlam. , Orthopadics Department Implants Items , D.H.S. Plate Long Barrel (38 Mm) With Round Holes 1250, 1300, 1350, 1400 Angle; 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18 Holes , D.H.S. Plate Long Barrel (38 Mm)With D. C. Holes 1250, 1300, 1350, 1400 Angle; 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18 Holes , D.H.S. Plate Long Barrel (38 Mm) With Combi Holes 1250, 1300, 1350, 1400 Angle; 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18 Holes , D.H.S. Plate, Short Barrel (25 Mm)With Round Holes 1250, 1300, 1350, 1400 Angle; 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18 Holes , D.H.S. Plate, Short Barrel (25 Mm) With D. C. Holes 1250, 1300, 1350, 1400 Angle; 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18 Holes , D.H.S. Plate, Short Barrel (25 Mm) With Combi Holes 1250, 1300, 1350, 1400 Angle 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18 Holes , D.H.S Screw 22Mm Threading With Compression Screw (Top-Bolt). (36 Mm) 50 To 115 Mm, In 5Mm Increments , D.H.S. Screw 16Mm Threading With Compression Screw (Top-Bolt). 50 To 115 Mm, In 5Mm Increments , Pediatric D.H.S. Set , D.C.S Plate (950) With Round Holes 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20, 22, 24 Holes , D.C.S Plate (950) With D. C. Holes 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20, 22, 24 Holes , D.C.S Plate (950) With Combi Holes 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20, 22, 24 Holes Note:- The Implants Listed From Item No. 1 To 12 Should Be Supplied Along With All The Instruments Required For Insertion (For Which No Extra Charges/Rent Will Be Levied), Which Shall Be Returned Back After Completion Of The Operation, & Which Should Be Of The Same Company As The Implant, So As To Avoid Mismatch Between The Implant-Instrument Fitting. , Angle Blade Plate (950) With Round Holes Blade Size 50, 55, 60, 65, 70 & 75 Mm. 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18 Holes , Angle Blade Plate (950) With D. C. Holes Blade Size 50, 55, 60, 65, 70 & 75 Mm. 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18 Holes , Condylar Buttress Plate With Round Holes 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , Condylar Buttress Plate With D. C. Holes 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , Condylar Buttress Plate With Combi Holes 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes Note:- The Implants Listed From Item No. 13 To 17 Should Be Supplied Along With The Specific Instrumentation Required For Their Insertion (For Which No Extra Charges/Rent Will Be Levied), Which Shall Be Returned Back After Completion Of The Operation, & Which Should Be Of The Same Company As The Implant, So As To Avoid Mismatch Between The Implant- Instrument Fitting. , Trochanteric Stabilisation Plate To Be Used With Dhs , Contoured Locking Plate For Fracture Shaft Femur (Right & Left)- As Per Ao Specifications. 3, 5, 7, 9, 13, (Combi Holes) , Distal Femur Locking Compression Plate (Right & Left) Anatomical Pre-Shaped & Contoured With Self-Tapping Locking Head Screws; With Round Locking Holes For Metaphyseal Portion Of Plate & Combiholes For Shaft Of Plate. , Medial & Lateral Proximal Tibial Buttress Plate (T- & L- Shape)- As Per Ao Specifications. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , Proximal Medial Tibial Plate 3.5 Mm 1. Anatomically Pre Shaped And Low Profile. 2. Two Different Plate Design For Left And Right Side With Indication On Side Of Plate. 3. Plate Should Have 2 Mm Holes Forproximal Fixation With K-Wire And Sutures For Meniscal Repair. 4. Holes Should Accept 3.5 Mm Locking Head Or 3.5 Mm Standard Cortical Screws From 4 To 20Holes With Increment Of 2 Holes. , Proximal Lateral Tibial Locking Plate For 4.5 Mm Screws 1. Anatomically Pre Shaped And Low Profile Design, Two Different Plate Design For Left And Right With Indication On Plate. 2. Round Metaphyseal Locking Holes And Combi Holes In Shaft Portion For Locking And Standard Screws. 3. Different Angulation In Proximal Part Of The Plate To Avoid Primary And Secondary Loss Of Reduction. 4. Should Be Compatible For Less Invasive Technique. 5. Holes Should Accept 5 Mm Locking Head Or 6.5 Mm Standard Cancellousl Screwsfrom 5 To 13Holes , L C P 3.5 Mm Proximal Lateral Tibial Plate 1. Anatomically Pre Shaped And Low Profile, Plate Should Havethree To Four 2 Mm Holes In Most Proximal Part For Fixation With K-Wire And Suture . 2. Should Have Holes For Four Convergent 3.5 Mm Locking Screws Designed To Allow Locking Screws To Support Medial Fragment, Plate Design Should Allow Screws In Head Of The Plate To Support The Subchondral Bone. 3. Shaft Portion Should Have Combi Holes To Accept 3.5 Mm Locking Head Screws And 3.5 Mm Standard Cortical Screw. 4. Should Be Available In Left And Right Sides With 4 To 16 Holes With 2 Hole Increments , L- Buttress Plates For Right & Left Side 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , L- Buttress Locking Plates For Right & Left Side 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , T- Buttress Plates For Right & Left Side 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , T- Buttress Locking Plates For Right & Left Side 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , Hockey Plate For Tibia (Right & Left) 5, 7, 9, 11, 13, 15, 17 Holes , Hockey Locking Plate For Tibia (Right & Left) 5, 7, 9, 11, 13, 15, 17 Holes , Contoured Medial/ Antero-Lateral Plate For Lower End Tibia 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , Distal Medial Tibial Locking Plates 2.7/ 3.5 Mm 1. Anatomically Pre-Shaped And Low Profile And Specific For Right And Left Side With Indication Of Side On Plate, Compatible With Less Invasive Fixation. 2. Rounded Edgesscrew Heads Should Be Received Into Distal Section Of Plate To Allow Multiple Locking Head Screw Placement Of 2.7/ 3.5 Mm To Provide Adequate Fixation Of Metaphyseal Portion Of Tibia, And Size 4 To 14 Holes With Increment Of 2 Holes. , Anterolateral Distal Tibial Locking Plate 3.5 Mm 1. Anatomically Pre Shaped And Low Profile And Specific For Right And Left Side With Indication Of Side On Plate. Plate Should Have Head Holes To Accept 3.5 Mm Locking Head Or Standard Cortical Or 4 Mm Standard Cancellous Screw. 2. Head Should Be Received Into The Plate. 3. Size From 5 To 21 Holes With Increment Of 2 Holes , Clover Leaf Plate 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , Clover Leaf Locking Plate 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , Cobra Head Plate 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , Cobra Head Locking Plate 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , Hook Plate 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , Hook Locking Plate 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , Proximal Humerus Locking Plate (Philos Plate) Anatomically Pre-Countoured Plates Should Have Precisely Fitting Sleeves For Precision Placement Of Screws. Should Accept 3.5 Mm Locking Head Screws. The Screws Provided Should Be Available From 26 To 60 Mm Length. The Head Of The Plate Should Have Holes For Securing Tuberosities To The Plate With Sutures. Should Have Low Profile Of The Screws Heads To Prevent Tissue Irritation. 3, 4, 5, 6, 7, 8, 9, 10, 12 Holes , Contoured Locking Plate For Distal End Humerus.(Prices To Be Quoted Separately For The Following 2 Items) 218. Anatomically Pre-Countoured Plates For Distal Medial Humerus For Anatomical Fit With Left & Right Version Should Have Precisely Fitting Sleeves For Precision Placement Of Screws. Should Accept Self-Tapping Locking Head Screws. The Shaft Portions Of The Plate Should Have Combi Holes. Should Have Low Profile Of The Screws Heads To Prevent Tissue Irritation. 3, 5, 7, 9 & 14 Holes 219. Dorso-Lateral Plates With & Without Lateral Support With Right & Left Versions Anatomically Pre-Countoured Plates The Shaft Portions Of The Plate Should Have Combi Holes Should Have Low Profile Of The Screws Heads To Prevent Tissue Irritation. 3, 5, 7, 9 & 14 Holes , Calcaneal Plate. , Calcaneal Locking Plates. , Clavicle Locking Plate- Antero-Superior Type , Clavicle Locking Plates- Anterior Type , Clavicle Hook Plate. , Elise Plate/ Contoured Plate For Distal End Radius. 3, 4, 5, 6, 7, 8, 9, 10 Holes , Locking Elise Plate/ Contoured Locking Plate For Distal End Radius. 3, 4, 5, 6, 7, 8, 9, 10 Holes , H-Plate. 3, 4, 5, 6, 7, 8, 9, 10 Holes , Y- Plate. 3, 4, 5, 6, 7, 8, 9, 10 Holes , D.C.P. Small. 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes , D.C.P. Narrow. 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , D.C.P. Broad. 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , L.C.D.C.P Small. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes , L.C.D.C.P. Narrow. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , L.C.D.C.P. Broad. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , L.C.P Small. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes , L.C.P. Narrow. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , L.C.P. Broad. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 18, 20 Holes , Semi Tubular Plates 4.5Mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes , Semi Tubular Plates 3.5Mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes , 1/3 Rd Tubular Plates 4.5Mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes , 1/3 Rd Tubular Plates 3.5Mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes , Quarter-Tubular Plates 2.7 Mm. 3, 4, 5, 6, 7, 8 Holes , Straight Mini Plates 2.0 Mm & 1.5 Mm. 20 Holes , Reconstruction Plates 3.5Mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes , Reconstruction Locking Plates 3.5Mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes , Reconstruction Plates 4.5Mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes , Reconstruction Locking Plates 4.5Mm. 3, 4, 5, 6, 7, 8, 9, 10, 12, 14 Holes , Cortical Screw 4.5 Mm (Tpi- 20). 14, 16, 18 …60 Mm, In 2 Mm Increments. , Cortical Screw 3.5 Mm (Tpi- 20). 8, 10, 12 …60 Mm, In 2 Mm Increments. , Cortical Screw 2.7 Mm (Tpi- 20). 6, 8, 10 …30 Mm, In 2 Mm Increments. , Locking Cortical Screw 5.0 Mm. 14, 16, 18 …60 Mm, In 2 Mm Increments. , Locking Cortical Screw 3.5 Mm. 8, 10, 12 …60 Mm, In 2 Mm Increments. , Fully Threaded Cannulated Cancellous Screws 4Mm. 25, 30 ….115 Mm, In 5 Mm Increment. , 16 Mm Threaded Cannulated Cancellous Screws 4 Mm. 25, 30 ….115 Mm, In 5 Mm Increment. , 32 Mm Threaded Cannulated Cancellous Screws 4 Mm 25, 30…….115 Mm, In 5 Mm Increment. , Fully Threaded Solid Cancellous Screws 4 Mm 25, 30…….115 Mm, In 5 Mm Increment , 16 Mm Threaded Solid Cancellous Screws 4 Mm 25, 30,…….115 Mm, In 5 Mm Increment , 32 Mm Threaded Solid Cancellous Screws 4 Mm 25, 30,…….115 Mm, In 5 Mm Increment , Fully Threaded Cannulatedcancellous Screws 6.5 Mm 25, 30,…….115 Mm, In 5 Mm Increment , 16 Mm Threaded Cannulated Cancellous Screws 6.5 Mm 25, 30,…….115 Mm, In 5 Mm Increment , 32 Mm Threaded Cannulated Cancellous Screws 6.5 Mm 25, 30,…….115 Mm, In 5 Mm Increment , Fully Threaded Solid Cancellous Screws 6.5 Mm (20 Tpi) 25, 30,…….115 Mm, In 5 Mm Increment , 16 Mm Threaded Solid Cancellous Screws 6.5 Mm (20 Tpi) 25, 30,…….115 Mm, In 5 Mm Increment , 32 Mm Threaded Solid Cancellous Screws 6.5 Mm (20 Tpi) 25, 30,…….115 Mm, In 5 Mm Increment , Fully Threaded Locking Cannulated Cancellous Screws 6.5 Mm 25, 30,…….115 Mm, In 5 Mm Increment , 16 Mm Threaded Locking Cannulated Cancellous Screws 6.5 Mm 25, 30,…….115 Mm, In 5 Mm Increment , 32 Mm Threaded Locking Cannulated Cancellous Screws 6.5 Mm 25, 30,…….115 Mm, In 5 Mm Increment , Fully Threaded Locking Solid Cancellous Screws 6.5 Mm 25, 30,…….115 Mm, In 5 Mm Increment , 16 Mm Threaded Locking Solid Cancellous Screws 6.5 Mm 25, 30,…….115 Mm, In 5 Mm Increment , 32 Mm Threaded Locking Solid Cancellous Screws 6.5 Mm 25, 30,…….115 Mm, In 5 Mm Increment , Washer Round, 13 Mm, 10 Mm, 7.0 Mm, 4.5 Mm. , Spiked Washer, 13.5 Mm, 8.0 Mm, 3.2 Mm. , Nut For 4.5 Mm Cortex Screw. , Malleolar Screw,4.5 Mm 15, 20, 25,………100 Mm , Herbert’S Screw Note:- The Implants Listed From Item No. 18 To 97 Should Be Supplied Along With All The Instruments Required For Insertion (For Which No Extra Charges/Rent Will Be Levied), Which Shall Be Returned Back After Completion Of The Operation, & Which Should Be Of The Same Company As The Implant, So As To Avoid Mismatch Between The Implant-Instrument Fitting. , Interlocking Femur Nail (As Per Ao Specifications) With Compatible Locking Bolts Diameterlength 8 Mm 340 To 440 Mm 9 Mm 340 To 440 Mm 10 Mm 340 To 440 Mm 11 Mm 340 To 440 Mm 12 Mm 340 To 440 Mm , Interlocking Solid Femur Nail (As Per Ao Specifications) With Compatible Locking Bolts Diameterlength 8 Mm 340 To 440 Mm 9 Mm 340 To 440 Mm 10 Mm 340 To 440 Mm 11 Mm 340 To 440 Mm 12 Mm 340 To 440 Mm , Recon Nail (Right & Left) (As Per Ao Specifications) With Compatible Locking Bolts Diameterlength 8 Mm 340 To 440 Mm 9 Mm 340 To 440 Mm 10 Mm 340 To 440 Mm 11 Mm 340 To 440 Mm 12 Mm 340 To 440 Mm , Proximal Femur Nail (P. F. N.) (As Per Ao Specifications) With Compatible Locking Bolts Diameterlength 8 Mm 340 To 440 Mm 9 Mm 340 To 440 Mm 10 Mm 340 To 440 Mm 11 Mm 340 To 440 Mm 12 Mm 340 To 440 Mm Trochanteric Entry Femur Nails With Compatible Locking Bolts Diameterlength 8 Mm 340 To 440 Mm 9 Mm 340 To 440 Mm 10 Mm 340 To 440 Mm 11 Mm 340 To 440 Mm 12 Mm 340 To 440 Mm , Supracondylar Nail (As Per Ao Specifications) With Compatible Locking Bolts Diameterlength 10 Mm 150,200,250,300 Mm 11 Mm 150,200,250,300 Mm 12 Mm 150,200,250,300 Mm , Interlocking Tibia Nail (As Per Ao Specifications) With Compatible Locking Bolts Diameter Length 8 Mm280 To 380 Mm 9 Mm280 To 380 Mm 10 Mm280 To 380 Mm 11 Mm280 To 380 Mm , Interlocking Distal Tibia Nail (As Per Ao Specifications) With Compatible Locking Bolts Diameter Length 8 Mm280 To 380 Mm 9 Mm280 To 380 Mm 10 Mm280 To 380 Mm 11 Mm280 To 380 Mm , Interlocking High/Upper Bent Tibia Nail (As Per Ao Specifications) With Compatible Locking Bolts Diameter Length 8 Mm280 To 380 Mm 9 Mm280 To 380 Mm 10 Mm280 To 380 Mm 11 Mm280 To 380 Mm , Interlocking Solid Tibia Nail (As Per Ao Specifications) With Compatible Locking Bolts Diameterlength 8 Mm280 To 380 Mm 9 Mm280 To 380 Mm 10 Mm280 To 380 Mm 11 Mm280 To 380 Mm , Expert Tibial Nail (As Per Ao Specifications) With Compatible Locking Bolts Diameterlength 8 Mm280 To 380 Mm 9 Mm280 To 380 Mm 10 Mm280 To 380 Mm 11 Mm280 To 380 Mm , Interlocking Humerus Nail (As Per Ao Specifications) With Compatible Locking Bolts Diameterlength 6 Mm 200 To 300 Mm 7 Mm 200 To 300 Mm 8 Mm 200 To 300 Mm , Interlocking Bolts(As Per Ao Specifications) Diameterlength 2.9 Mm 12 To 30 Mm 3.9 Mm 14 To 48 Mm 4.9 Mm 16 To 120 Mm , Proximal Bolt Recon (As Per Ao Specifications) Diameterlength 6.4 Mm 60 To 110 Mm , Proximal Bolt Recon Cannulated (As Per Ao Specifications) Diameterlength 6.4 Mm 60 To 110 Mm , Proximal Bolt P.F.N. Cannulated (As Per Ao Specifications) Diameterlength 6.4 Mm 60 To 110 Mm 8.0 Mm 60 To 120 Mm Note:- The Implants Listed From Item No. 98 To 112 Should Be Supplied Along With All The Instruments Required For Insertion (For Which No Extra Charges/Rent Will Be Levied), Which Shall Be Returned Back After Completion Of The Operation, & Which Should Be Of The Same Company As The Implant, So As To Avoid Mismatch Between The Implant-Instrument Fitting. , Kuntscher’S Nail 7, 8, 9, 10, 11, 12 Mm Diameter Note:- The Implant Listed In Item No. 113 Should Be Supplied Along With All The Instruments Required For Insertion (For Which No Extra Charges/Rent Will Be Levied), Which Shall Be Returned Back After Completion Of The Operation, & Which Should Be Of The Same Company As The Implant, So As To Avoid Mismatch Between The Implant-Instrument Fitting. , V-Nail Note:- The Implant Listed In Item No. 114 Should Be Supplied Along With All The Instruments Required For Insertion (For Which No Extra Charges/Rent Will Be Levied), Which Shall Be Returned Back After Completion Of The Operation, & Which Should Be Of The Same Company As The Implant, So As To Avoid Mismatch Between The Implant-Instrument Fitting. , Square Nail For Ulna 2, 2.5, 3, 3.5 Mm Diameter , Square Nail For Radius 2, 2.5, 3, 3.5 Mm Diameter Note:- The Implants Listed In Item No. 115 & 116 Should Be Supplied Along With All The Instruments Required For Insertion (For Which No Extra Charges/Rent Will Be Levied), Which Shall Be Returned Back After Completion Of The Operation, & Which Should Be Of The Same Company As The Implant, So As To Avoid Mismatch Between The Implant-Instrument Fitting. , Rush Nail. 2.5, 3, 3.5 Mm Diameter. Note:- The Implant Listed In Item No. 117 Should Be Supplied Along With All The Instruments Required For Insertion (For Which No Extra Charges/Rent Will Be Levied), Which Shall Be Returned Back After Completion Of The Operation, & Which Should Be Of The Same Company As The Implant, So As To Avoid Mismatch Between The Implant-Instrument Fitting. , Ender’S Nail. 3.5, 4, 4.5 Mm Diameter. , Titanium Elastic Nailing System (Tens). Note:- The Implant Listed In Item No. 118 & 119 Should Be Supplied Along With All The Instruments Required For Insertion (For Which No Extra Charges/Rent Will Be Levied), Which Shall Be Returned Back After Completion Of The Operation, & Which Should Be Of The Same Company As The Implant, So As To Avoid Mismatch Between The Implant-Instrument Fitting. , Non Fenestrated Bipolar Prosthesis 37, 39,…………….51, 53 Mm , Fenestrated Bipolar Prosthesis 37, 39,…………….51, 53 Mm , Bipolar Prosthesis With Modularity Component Typesize (I) Stem 1. Modularsmall,Medium,Large (Ii) Head1. Modular Size 39,41,43……….59 Mm Varying Neck Lengths With Increments Of 2.5 Mm To 3.5 Mm. Bipolar With Fixed Neck Length Component Typesize (I) Stemstandard (Ii) Head39,41,43……….59 Mm , Thompson Endo-Prosthesis. 37, 39, 41, 43, 45, 47, 49, 51, 53 Mm. , Long Stem Austin Moore Prosthesis 37, 39,……………………..51, 53 , Short Stem Austin Moore Prosthesis 37, 39,……………………..51, 53 , Austin Moore Endo-Prosthesis. 37, 39, 41, 43, 45, 47, 49, 51, 53 Mm. , Austin Moore Endo-Prosthesis Xl Finish. 37, 39, 41, 43, 45, 47, 49, 51, 53 Mm. Note:- The Implant Listed From Item No. 120 & 127 Should Be Supplied Along With All The Instruments Required For Insertion (For Which No Extra Charges/Rent Will Be Levied), Which Shall Be Returned Back After Completion Of The Operation, & Which Should Be Of The Same Company As The Implant, So As To Avoid Mismatch Between The Implant-Instrument Fitting. , Bone Cement (Price Tobe Quoted Separately For The Following 4 Items) 1. High Viscosity Poly Methyl Meth-Acrylate 40Gms With Working Time Of 5-6 Min. 2. Medium To Low Viscosity Poly Methyl Meth-Acrylate 40Gms. 3. High Viscosity Poly Methyl Meth-Acrylate 40Gms With Working Time Of 5-6 Min With Gentamycin. 4. Medium To Low Viscosity Poly Methyl Meth-Acrylate 40Gms With Gentamycin. Cement Gun Should Be Provide By The Dealer As Loan Instruments Without Extra Charges During Total Hip Replacement Surgeries. Cost Of Disposable Nozzle To Be Provided Separately . Cement Stopper Size …7,8,9……To………….16Mm , Calcium Sulphate Bone Substitutes , Cemented Totalhip Replacement Charnley’S Cemented Thr – *Stem Should Be As Per Standard Charnley’S Design With Metal Of Sufficient Strength To Withstand Life-Time Use In The Patients. Different Sizes And Offsets To Be Quoted. *Cup Of Polyethylene High Density High Molecular Weight Highly Cross Linked With Anti-Oxidative Manufacturing & Storing Process (To Increases The Shelf Life) With Different Offsets. *Cup Sizes : - 38 To 60 Mm Outer Diameter. *Cemented Thr With Polished Taper Stem With Tapering On Both Planes *Should Be Having Different Sizes To Cater For Small Stature, Thin Built Patient & Dysplastic Hip As Well As Large Hips. *Modularity For Neck Length And Head Sizes 22, 28, 32 And 36 Mm. *Acetabular Component Should Be Metal Backed As Well As All Poly. *Metal Back Should Have Modularity To Use Polyethylene As Well As Ceramic. *All Polyethylene Liner As Well As Cups Should Be Made Of Highly Cross-Linked Highmolecular Weight Polyethylene With Measures To Prevent Oxidation . *The Metal Used For Stem Should Be Of High Tensile Strength And Fatigue Strength Like Cobalt-Chrome. , Uncemented T.H.R. *The Stem Of The Femoral Component Should Have Double Taper Geometry With Plasma Hydroxy-Appetite Coating With At Least Thickness Of The Coating Of 100 To 200 Microns Or Porous Coated With Sufficient Pore Size And Thickness Of Porous Coating To Have Optimal Bony Ingrowth. *The Stem Should Accept Metal (Cobalt- Chrome) As Well As Ceramic Head (Alumina With Zirconia) *There Should Be Modularity Regarding Size Of Head & Neck Length. *Cup Of Polyethylene High Density High Molecular Weight Highly Cross Linked With Anti-Oxidative Manufacturing & Storing Process (Toincreases The Shelf Life) With Different Offsets. Preferably The Cup Should Have Longer Posterior Wall With Flange For Cement Pressurization. *Metal Back Cup With Plasma Hydroxy-Appetite Coating With Design To Lock Into The Host Bone To Provide Primary Fixation With Provision For Screw Fixation *Should Accept Liners Made Up Of Highly Cross-Linked High Molecular Weight Poly-Ethylene & Delta Ceramic (Alumina With Zirconia). *The Femoral Head Should Be Made Up Of Cobalt-Chrome Or Delta-Ceramic And Should Have Different Neck Length. *Metal Screws For Fixation Of Metal Cup. *The Whole System Should Have Modularity & Inter-Changeability. *The Prices Should Be Quoted Separately For Stems, Cups Liners Of Polyethylene And Ceramic As Per Specifications Mentioned Above And As Well As For Metal & Ceramic Heads Of Different Sizes As Per Specifications Quoted Above. , Revision T.H.R. *Revision Stem, Modular Straight Cylindrical And Double Tapered, Porous & Hydroxy-Appetite Coated Of Different Lengths. *The Diameter And Length Of The Stem Should Be Variable With A Provision To Address Curve Of The Femur With Long Stem. *Modularity Should Be Provided For Version, Offsets, Calcar Loss And Neck Length. *Revision Cups To Be Provided With Large Diameter Of Upto 65 Mm With Augments For Bone Loss In The Form Of Cages And Metal Rings, As Well As, Wedges. All These To Be Quoted Separately. , Total Knee Replacement All Polyethylene & Metal Back Mobile Bearing & Fixed Bearing Knees Highly Polished Tibial Tray To Prevent Back Wear In Fixed Bearing Knee. Adequate Sizes & Modularity Of Tibial Insert To Be Provided. Pateller Component Should To Be Quoted Separately Cruciate-Retaining/ Cruciate-Scarificing Designs. For Revision, Constraint Designs With Intramedullary Extension . Designs For Achieving High Flexion. All Components Should Be Separately Quoted. Note:- 1. Company Should Be Us-Fda /Ce/ Gmp Certified.. 2. Should Provide A Technician Intraoperatively Wherever Applicable. 3. Should Provide Suitable Size Cutting Saw With Drills (Pneumatic/Electric) , Wherever Applicable. 4. Should Provide All The Complementary Instrumentation And Trials Given/Provided By The Manufacturing Company For The Application Of Implant During Operation. 5. Catalogue/ List Of These Instrumentation And Trials Should Be Included In Tender Quotations. 6. The Cemented And Uncemented Hips Should Have Modularity For Interchangeability Of Cups, Heads And Stems. 7. Only Those Joint Designs To Be Sent Which Have Had A Proven Field Record Of Longevity As Substantiated By Published Literature, The Tenderer Should Provide The Required Documents , Regular Shoulder Prosthesis & Reverse Shoulder Prosthesis (Prices To Be Quoted Separately) 35 Mm, 39 Mm , Total Elbow Prosthesis Regular And Custom Made , Radial Head Prosthesis 16 Mm X 4 Mm X 6 Mm 18 Mm X 4 Mm X 6 Mm 18 Mm X 5 Mm X 6 Mm 20 Mm X 5 Mm X 8 Mm Note:- The Implants Listed In Item No. 134 To 136 Should Always Be Supplied Along With The Suitable Instrumentation (For Which No Extra Charges/Rent Will Be Levied), Which Shall Be Returned Back After Completion Of The Operation, & Which Should Be Of The Same Company As The Implant, So As To Avoid Mismatch Between The Implant- Instrument Fitting. , Continuous Loop Endobutton – Titanium Made Continuous Loop Endobutton One Size Titanium Buttonwith Multiple Pre-Measured Loop Sizes Of 15, 20, 25, 30, 35, 40Mm Lengths. Preloaded With Polyester Braid Suture (#5 Leading Suture & #2 Flipping Suture) , Low- Profile Cancellous Screws Titanium Made Low Profile Head To Reduce Soft Tissue Irritation 6.5 Mm Diameter Screw 25, 30, 35, 40Mm Lengths , Spiked And Suture Washers Washer 14 And 18 Mm , Tibial Post Fixation Screw Titanium Made Dia 6.5 Mm And 30 Mm Length , Shaver Blades And Burrs (Ss Alloy / Platinum Tip) Single Cutting:Razor Sharp Toothed Inner Blade No Teeth On Outerwindow 4Mm, 4.5 Mm 5Mm 5.5Mmstraight And Angled Double Cutting:The Narrow Gap Between Inner And Outer Cutting Surfaces 4Mm, 4.5 Mm 5Mm 5.5Mm Straight And Angled Resector:4Mm, 4.5 Mm 5Mm 5.5Mm Straight And Angled Burrs Barrel Burrs4mm, 4.5 Mm 5Mm 5.5Mm6 Flute And 12 Flute Round Burrs 4Mm, 4.5 Mm 5Mm 5.5Mm6 Flute And 12 Flute , Spiked Ligament Staple Titanium Made Small And Large , Cannulated Cross Pin Titanium Made 30Mm , Cannulated Interference Screws- Roundheadtitanium/Bio Absorvable • Standard 4.5Mm Hex For Easier Insertion And Removal. •In Diameters 8Mm, 9Mm, 10Mm And 11Mm. •In Lengths 20Mm, 25Mm, 30Mm And 35Mm. , Cannulated Interference Screws- Fully Threaded Titanium/Bio Absorvable •In Diameters 8Mm, 9Mm, 10Mm And 11Mm. •In Lengths 20Mm, 25Mm, 30Mm And 35Mm , Braided Composite Suture (I.E. Bio Fiber /Fiber Wire) • Multi-Strand, Long Chain Ultra-High Molecular Weight Polyethylene (Uhmwpe) Core With A Braided Jacket Of Polyester And Uhmwpe • Tapered ,Cutting ,Reverse Cutting And Diamond End ,3/8 Circle And ½ Circle •White; White/Blue; White/Green Colours. • Usp Size 2/ Ep Size 5. • Length 38 Inches/90 Cms. , Braided Polyester Suture( I.E.Ethibond ) •Braided, Sterile, Surgical Suture Composed Of Poly (Ethylene Terephthalate). •Prepared From Fibers Of High Molecular Weight, Long-Chain, Linear Polyesters Having Recurrent Aromatic Rings As An Integral Component. • Coated With Polybutilate Or Poly {Oxy-1, 4 Butanediyloxy (1, 6-Dioxo-1, 6 Hexanediyl) • 2-0 And 5-0 With 4 Strands , 5Mmsynthetic, Braided, Non-Absorbable Suture (I.E. Mersilene Tape) From Fibers Of High Molecular Weight, Long-Chain, Linear Polyesters , Titanium Interference Screws For Acl Repair. Sizes 8 Mm, 9 Mm, 10 Mm, 11 Mm, 12 Mm. , Titanium Endo-Button. , Titanium Endo-Disc. Note:- The Implants Listed From Item No. 137 To 151 Should Always Be Supplied Along With The Suitable Instrumentation (For Which No Extra Charges/Rent Should Be Levied), Which Shall Be Returned Back After Completion Of The Operation, & Which Should Be Of The Same Company As The Implant, So As To Avoid Mismatch Between The Implant- Instrument Fitting. , A. O. Open Clamps. 2.5, 3.5, 4.5 Mm. , A. O. Closed Clamps. 2.5, 3.5, 4.5 Mm. , Cylindrical/ Universal Clamps. 2.5, 3.5, 4.5 Mm. , Rod To Rod Clamp. , Transverse Clamp. , Cortical Schanz Pin 4.5 Mm. , Cortical Schanz Pin 4.0 Mm. , Cortical Schanz Pin 3.5 Mm. , Cortical Schanz Pin 3.0 Mm. , Cortical Schanz Pin 2.5Mm. , Cancellous Schanz Pin 5 Mm. , Cancellous Schanz Pin 6 Mm. , Tubular Rod. , Connecting Rod. 4, 5, 8, 10, 11 Mm Diameter. 4”, 6”, 8”, 10”, 12”, 14”, 16”, 18”. 100- 200 Mm With 50 Mm Of Increment. , A.O. Type External Fixator R/U. , Finger Distractor. , Radius Ulna Distractor. , Rail Road Fixator For Femur/ Tibia. Note:- The Implants Listed From Item No. 152 To 169 Should Always Be Supplied Along With The Suitable Instrumentation (For Which No Extra Charges/Rent Should Be Levied), Which Shall Be Returned Back After Completion Of The Operation, & Which Should Be Of The Same Company As The Implant, So As To Avoid Mismatch Between The Implant- Instrument Fitting. , Illizarov’S Ring Fixator. Half Ring. 80, 100, 120, 140, 160, 180, 200, 220, 240 Mm. , Italian Femoral Arches 900, 1200. 80, 100, 120, 140, 160, 180, 200, 220, 240 Mm. , Multiple Fixation Clamps. , Schanz Pin Fixation Bolts. , Oblique Supports. , Threaded Rods. 8 Mm Diameter. 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450 Mm. , Telescopic Rods. 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 Mm. , Male & Female Post. 2, 3, 4, 5 Hole Set. , Male & Female Hinges. 1 Hole Set. , Connection Plates. 5, 6, 7, 8 Holes. , Twisted Plates. 5, 6, 7, 8 Holes. , Illizarov’S Wires Bayonet Type. 1.5, 1.8, 2.0 Mm. , Illizarov’S Wires Olive Type. 1.5, 1.8, 2.0 Mm. , Connecting Bolt. , Connecting Nut 10 Mm. , Wire Fixation Bolts Cannulated. , Wire Fixation Bolts Slotted. Note:- The Implants Listed From Item No. 170 To 186 Should Always Be Supplied Along With The Suitable Instrumentation (For Which No Extra Charges/Rent Should Be Levied), Which Shall Be Returned Back After Completion Of The Operation, & Which Should Be Of The Same Company As The Implant, So As To Avoid Mismatch Between The Implant- Instrument Fitting. , Jess External Fixator Set. , Pelvic C Clamp. , Nails For Pelvic C Clamp. , Steinman Pin. 3, 3.5, 4, 4.5, 5 Mm. , Denham Pin. 3, 3.5, 4, 4.5, 5 Mm. , Kirschner Wire Double Ended Trocar Tip/ Threaded Tip. Diameter 1, 1.5, 2, 2.5, 3 Mm. Length 6”, 9”, 12”. Note:- The Implants Listed In Item No. 192 Should Always Be Supplied Along With The Suitable Instrumentation (For Which No Extra Charges/Rent Should Be Levied), Which Shall Be Returned Back After Completion Of The Operation, & Which Should Be Of The Same Company As The Implant, So As To Avoid Mismatch Between The Implant- Instrument Fitting. , S.S. Wire Reel. 16 To 28 Gauze. Note:- The Implants Listed In Item No. 193 Should Always Be Supplied Along With The Suitable Instrumentation (For Which No Extra Charges/Rent Should Be Levied), Which Shall Be Returned Back After Completion Of The Operation, & Which Should Be Of The Same Company As The Implant, So As To Avoid Mismatch Between The Implant- Instrument Fitting. , Knowel’S Pin. , A.M. Pin. , Giglisaw Wire. , Titanium Pedicle Screw & Rod Set (Mri- Compatible). , Titanium Cage (Mri- Compatible). 10Mm, 13Mm, 16 Mm, 19 Mm. , Titanium Staple (Mri- Compatible). , Titanium Transverse Connector (Mri- Compatible). , Titanium Mono- Axial Screws (Mri- Compatible) 5.3 Mm30 Mm, 35 Mm, 40 Mm, 45 Mm. 6.0 Mm30 Mm, 35 Mm, 40 Mm, 45 Mm. , Titanium Poly- Axial Screws (Mri- Compatible) 5.3 Mm30 Mm, 35 Mm, 40 Mm, 45 Mm. 6.0 Mm30 Mm, 35 Mm, 40 Mm, 45 Mm. , Titanium Mono- Axial And Poly- Axial Pedicle Screws Compatible Rod (Mri- Compatible) , Hartsheel Implants For Spine (Mri- Compatible). , Cervical Plates (Mri- Compatible). , Harrington Rod System (Mri- Compatible). , Mono Axial Locking Screw 4.5 Mm, 5.5 Mm, 6.5 Mm Diameter 30-50 Mm With 5 Mm Of Increment , Mono Axial Locking Screw 6.5 Mm Diameter (Iliac Screw) 60 – 75 Mm With 5 Mm Of Increament , Cross Link (Inter Connector) 5 Mm , Cervical H-Plate Ordinary Hole4 Hole 20 – 35 Mm With 2.5 Mm Of Increament , Cervical H-Plate Ordinary Hole6 Hole 35 – 55 Mm With 2.5 Mm Of Increament , Cervical H-Plate Ordinary Hole8 Hole 47.5 – 65 Mm With 2.5 Mm Of Increament , Cervical Spine Locking Plate 5 Hole 25, 29, 33 Mm , Cervical Spine Locking Plate 8 Hole 37, 41, 45 Mm , Drummonds Wire Without Button , Drummonds Wire With Button , Sublaminar Wire 12” , Sublaminar Wire 18” Note:- The Implants Listed From Item No. 197 To 217 Should Always Be Supplied Along With The Suitable Instrumentation (For Which No Extra Charges/Rent Should Be Levied), Which Shall Be Returned Back After Completion Of The Operation, & Which Should Be Of The Same Company As The Implant, So As To Avoid Mismatch Between The Implant- Instrument Fitting. , Disposable Pulse Lavage Tubings. , Dental Department Implants Items , Drill Bits (1Mm) , Drill Bits (1.5Mm) , Drill Bits (2Mm) , Drill Bits (2.5Mm) , Stainless Steel Wire (26 Gauge) , Erich Arch Bar , Titanium Plates With Bar & Without Bar 4 Hole Titanium Plate (1.5Mm, 2Mm, 2.5Mm) , Titanium Plates With Bar & Without Bar 2 Hole Titanium Plate (1.5Mm, 2Mm, 2.5Mm) , Titanium Plates With Bar & Without Bar Continous Plate Titanium Plate (1.5Mm, 2Mm, 2.5Mm) , Titanium Plates With Bar & Without Bar L Shaped Titanium Plate (1.5Mm, 2Mm, 205Mm) , Titanium Screw (Should Be Cross Hole) 1.5Mm (4Mm, 6Mm, 8Mm, 10Mm) , Titanium Screw (Should Be Cross Hole) 2 Mm(4Mm, 6Mm, 8Mm, 10Mm) , Titanium Screw (Should Be Cross Hole) 2.5Mm (4Mm, 6Mm, 8Mm, 10Mm)
|