supply of Laboratory Machine And Equipment , Melting Point Apparatus , Melting Point In 250Ml Beaker Silicon Oil Bath. Max Temp 300-350 Dgc, Teflon Dish Cover For Holding Heater, Capillary Stand,3 Capillaries Holes, Sensor & Thermometer, 12V Long Lasting Immersion Heater Connected To Transformer In Order To Give Quick Heating & Fine Calibration, No Shock Hazard, Built In Heavy Duty Magnetic Stirrer & Heavy Duty Magnet Used For Trouble Free & Uniform Stirring, Glare Free Back Side Illumination & Magnifying Viewing Glass & 3 Way Rotary Switch To Control Heating Rate For Diff Stage Of M.P. Plus Additional Regulator For Further Heating Control. 3 Capillaries Stand & Provision To Keep 6Mm Glass Boiling Tube. Provided With 1 Pkt Of Capillaries & 1 Boiling Tube. , Water Purification System (Milli Q Water) , Water Purification System Capable Of Independently Dispensing Both Type I And Type Ii Water. Type Ii Able To Use Tap Water As Feed (Able To Accept Upto 2000 Micro Siemens Conductivity Tap Water Should Be Treated In A Pre-Treatment Cartridge For Efficient Removal Of Particles, Colloids, Free Chlorine And Hardness Reverse Osmosis Step Should Be Water Conservative And Should Ensure Constant Flow Rate And Optimal Water Quality All The Cartridges Used Should Have Considerable Life Should Have Electro Deionisation Or Other Equivalent Or Superior Technology For Removal Of Ions The Resin Beads Used Should Be Of Superior Quality And Should Not Degrade By Exposure To Harsh Chemicals The Resin Beads Should Be Able To Be Continuously Regenerated Without Affecting Its Quality The Module Should Be Able To Continuously Regenerate Its Beads Used. Thereby Effectively Reducing Operational Cost The Cartridges Should Be Easily Replaceable The Replacement Cartridges Should Not Be Very Expensive The Equipment Should Have A Low Maintenance Cost The Generated Water Should Be Treated With Uv To Destroy Bacteria, Before It Is Stored In The Storage Tank The Storage Tank Should Be Capable Of Maintaining The Purity Of Stored Water A Vent Filter Should Be There For Preventing Airborne Contamination. Biofilm Formation Should Be Prevented The Water Dispenser Should Be Designed Such That Various Small Filters/Cartridges Can Be Connected For Obtaining Specific Quality Water For Different Research Needs (Ultra Pure Water Free Of Particulates, Pyrogens, Nucleases, Vocs, Endocrine Disruptors And Organics For Lc. Should Be Able To Dispense Pre Assigned Volume Of Water Production Rate Minimum 5L/H Should Have Calibrated Meters For Continuous Monitoring And Display Of Water Quality Parameter Should Have Certificate Of Calibration From Recognized International Agencies Should Have Certificate Of Conformity From Recognized International Agencies Should Meet Internationally Recognized Safety Norms Prompt Services Should Be Available A Minimum Warranty For One Year. Amc Terms & Conditions Beyond The Warranty Period To Be Specified Three Separate Quote Should Be Made: - 1) Water Purification System For Type I Quality Water. 2) Water Purification System For Type Ii Quality Water. 3) An Integrated Water Purification System Capable Of Producing And Dispensing Both Type I And Type Ii Water. Type I Water With The Following Properties O Resistivity (M?-Cm) = 18.2M?•Cm @ 25 Deg C O Conductivity (?S/Cm) < 0.055 ?S/Cm O Toc =5Ppb O Bacteria 0.22?M) < 1 O Chloride (Ppb) < 1 O Total Silica (Ppb) < 3 O Flow Rate = 2L/Min • Type Ii Water With The Following Property O Resistivity (M?-Cm) = 12-15 M?•Cm @ 25 Deg C, Or More O Conductivity (?S/Cm) 0.22?M) < 5 O Chloride (Ppb) < 5 O Total Silica (Ppb) < 3 O Flow Rate = 2L/Min , Rotarod , Base Unit Dimensions Should Be :362(W) X 240(D)X400 (H) Mm, 1 Drum(250 Mm Diameter) Composed By A Rod (60Mm Diameter) And 4 Lines( 75 Mm Wide) , Should Come With Built-In Rs 232(Usb) Port For Data Transfer To A Computer Through The Seda Com Software. Renewable Hood (150Mm Height) Avoiding Interference Between Animals Running In Adjustment Lanes Base Unit Characteristics Perspex, Arnite (Lanes) . Operating Volatage Mustbe 220 V.50/60Hz. Constant Speed Mode (Run) Speed :4-40Rpm. Acceleration Mode (Acc) 4-40Rpm In Acceleration Time Of 30Sceonds(Standard Procedures) And Also 1,2,5, Or10 Minutes , Rotary Vaccum Evaporator , Digital Vapor Temperatures Indicator With Sensor With Approximately 4 Liters Water Bath Capacity Of 30-270 Rpm. Bath Temperature Range Of +5 To 180°C Temperature Accuracy Of ±2°C. Dimension Of Heating Bath Dimensions 23 X 130Mm , Microprocessor Controlled Stability Chamber With Vs-04 Voltage Stabilizer (Gmp Model) , Internal Volume 200 Liters,No Of Shevlves 02,Int. Demensions W X D X H(Mm) 660 X 655 X 450,Ext. Demensions W X D X H(Mm)800 X 1095 X 1020,Temperature Control Microprocessor Tempararure Range 10 To 60?C ± 1? C,Humadity Range 40 To 95 % ± 3%,Inner Chamber Material Stainless Steel 316 Asis (Non Magnetic),Outer Body Material Powder Coated Crca, Stainless Steel 304 Asis(Non Magnetic),Digital Display Of Temperature &Humidity, Menu Driven 10 Program Memory,Safety Thermostat To Prevent Over Heating, Audio Visual Alarm Warning Of Temp. &Rh Variation And Low Water Level, Built In Safety Circuit, Which Cuts Off Systems &Stops Unit In Case Of Manufacture Of Microprocessor,Centronics Interface For Keeping Hard Copy Of Temp. Humadity, Time &Date Rs.485Interface To Tranfer Data To Pc For Further Analysis,Non Volatile Memory For Data Storage Up To 25000 Record, Adjustable Print Interval, High Voltage Safety Cutoff For Unit Protection, Validation Protocol For Iq,Oq,Pq As Per Ich Guidlines, Minimum Three Years Warranty Followed By Three Years Amc , High Pressure Homogenizer , Equipment Capable Of Processing For Applications Like Nano Emulsions , Cellulose Fibres, Fine Particle Deagglomeration, Liposomes, Cell Disruption Studies On Bacteria, Algae And Yeast Cells Etc.System Having Hydraulic Constant High Shear Homogenizer To Prepare Stable Nano-Emulsions, Nano-Dispersions And For Microencapsulation Studies.Minimum Sample Volume: The System Should Be Capable Of Processing Low Volume Samples 20 Ml Or Less.Flow Rate : Approx. 60 – 100 Ml/Minute Or More. Operating Pressure:System Is Capable To Generate Pressure Up To 30,000 Psi Or Higher.System Should Have Fixed Geometry Interaction Chamber To Generate High Shear Preferably Made Of Hard Material Like Diamond For Long Life.The Homogenization System Should Have Micro Channels Of Fixed Orifice Which Should Not Change With Change In Pressure. Should Have Digital Pressure Control & Display Along With Recirculation Assembly Allows Continuous Flow To Feed Reservoir.System Should Be Coupled With Single Pass Cooling Coil For Cooling Of Product System Must Automatically Stop Processing Product Without Exceeding Set Operating Pressure Upon Accidental Downstream Pipeline Closure.Should Have Pressure Piping For Reliable Cleaning Without Machine. Glass Inlet Reservoir Isassembly. Should Be Provided Min 300Ml To 500Ml.Processed Product Should Have Uniform Particle Size Distribution.Should Have Appropriate Certification To The Equipment Complying To Safety And Quality (Ce).Necessary Certificate Must Be Enclosed The Vendor Must Supply Appropriate Documents Specifying Their Users In Higher Academic Institutions Or Industry In India For Similar Application.All Processes Must Be Repeatable & Preferably Guaranteed To Scale Up To Pilot And/Or Production Volumes For The Same Pressure Range.Comprehensive Training On Operation, Handling, Data Analysis And Maintenance Should Be Provided To 5-7 Teachers And Students For 5 Days During Installation. A Certificate Will Be Required From The Original Instrument Manufacturer That Technical Support Along With All Essential Spares Will Be Provided / Made Available For At Least 10 Years After The Expiry Period. Amc Will Cover Main Instrument As Well As All Accessories Supplied With The Main Instrument.The Vendor Must Supply The Latest Clearly Readable Original Printed Copy Of Brochure Produced By The Original Equipment Manufacturer (Oem) Listing All Specifications Of The Equipment/System. Minimum Three Years Warranty Followed By Three Years Amc
|