Tender For Repair/Up gradation Of B/R Items To Water Supply Installation At Mil Stn Kota.; 1 Taking down cement plaster any description, on brick or stone walls, etc. including raking out joints, hacking for key & scrubbing down with water, etc. & removing rubbish off the premises/ MD land, complete all as specified and directed 2 M&L rendering 15 mm thick in CM 1:6 on brick masonry surfaces or on other than fair faces of brick masonry finished even and smooth without using extra cement complete all as specified and directed. 3 M&L 15mm thick rendering in cement mortar 1:4 to stone/ brick masonry wall surfaces or on other than fair faces of brick masonaryfinishedeven and smooth without using extra cementmixed with liquid water proofing compoundof cement complete all as specified and directed.Note : liquid water proofing compundshall be measured and paid seperately. 4 M&L rendering 5 mm thick in CM 1:3as on concerete surface on ceilings finished even and smooth without using extra cement complete all as specified and directed. 5 Dismantling of tiles in floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises / MD land , complete all as specified and directed. 6 M&L for coloured Glazed ceramic tiles of size 300x450mmx 6-7mmthick, as in dado / skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick cementmortar 1:4 complete all as specified and directed. 7 M&Lfor Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 but not exc 0.11 sqm etc. in floors over & including 15 mm thickcement screed bed of CM (1:6 ) etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. 8 M & L 25 mm thick PCC 1:2:4 type B-1, using 12.5 mm graded stone aggregate as in floors, surfaces finished fair and even complete all as specified and directed. 9 DismantlingStone sett paving like paver block,etc of any description or thicknesscomplete all as specified and directed. 10 Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness below or above ground levelincl removal of demolished material exc 1.5 km to 5 km, complete all as specified and directed . 11 M&L for 100 mm thick Cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub base, surfaces finished fair and even complete all as specified and directed. 12 Providing and laying 80 mm thick factory made cement concrete interlocking paver block glossy finish of M40 grade conforming to IS 15658: 2021 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 30 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. complete all as specified and as directed. 13 M & L for 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates, laid in alternate panel, finished surface even and fair including filling in position with 85/25 industrial grade bitumen mix filler of proportion 80 kg of hot bitumen, 1 kg of cement and 0.25 cubic metre of coarse sand as in plinth protection complete all as specified and as directed. 14 Demolition of cement concrete in any description and in any position, not otherwise specifically provided ,incl removal of demolished material exc 1.5 km to 5 km, complete all as specified and directed. 15 M&L Providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate,as in coping, tank platform,kerbswater trough & the like including weathering, slightly rounded or chamfered angles & throating, complete all as specified and directed. 16 M&L forProviding precast cement concrete in win-dow or door cills, lintels , cover slabs (man hole etc) ,type B-1 , 1:2:4(20 mm graded aggregate ), setting incement mortar 1 :4, including form work complete all as specified and as directed. 17 Demolition of cement concrete (reinforced) to roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work not exceeding 15 cm thickness & removal all rubbish material outside of MD Land complete all as specified and directed . 18 M&L for reinforced cement concrete (nominal mix) type B1 (1:2:4) using 20 mm graded stone aggregate as in chajjas /slab complete all as specified and directed. 19 M &L for 10mm dia and over mild steel TMT , cut to length ,bent to shape required including cranking and binding with and including mild steel wire (annealed) not less than 0.90mm dia as in mainbar and binders etc complete all as specified and directed. 20 M & L forform work to soffits of suspended slabs such as roof slabs, landings, stairecase , balcony ,chajjasn. exc. 20cm thick (horizontal or slopingfor rough finished concrete surface complete all as specified and directed. 21 Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc articles and removal all rubbish material outside of MD land complete all as specified and directed. 22 M & L for brick work with fly ash bricks, (Old size) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed. 23 Dismantling of 75mm bore cast iron drain pipe alongwith fittings and accessoriesjointed in cement mortar and taking out from walls, floors or fromtrenches, if required complete all as specified and directed. 24 Dismantling of 100mm bore cast iron drain pipe alongwith fittings and accessoriesjointed in cement mortar and taking out from walls, floors or fromtrenches, if required complete all as specified and directed. 25 S&F PVC (SWR) pipes 75 mm soil, waste & vent pipes, in any length with or without ears, with lead joints, laid in floors / walls with clamp complete all as specified and directed. 26 S&F PVC (SWR) pipes 110 mm soil, waste & vent pipes, in any length with or without ears, with leadjoint fixed to walls with clamp complete all as specified and directed. 27 S&FPVC (SWR) 75 mm Bends (any radius),diminishing pieces or tapers (large bore measured) with oval excess door complete all as specified and directed. 28 S&F PVC (SWR)110 mmBranch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval excess door complete all as specified and directed. 29 Taking up or down 15mm steel tubingand connections including cleaning for refixing or removal complete all as specified and directed 30 Taking up or down 20 mm steel tubingand connections including cleaning for refixing or removal complete all as specified and directed by Engr-in-Charge 31 S & F for 15 mm dia steel water tubing galvanized medium grade concealed in all type wallwith all fittings, fixed to walls and ceiling or in floor complete all as specified and directed. 32 S & F for20 mm dia steel water tubing, galvanized, medium gradeconcealed in all type wallwith all fittings,fixed to walls and ceiling or in floor complete all as specified and directed. 33 Taking down existingwater proofing roof treatment of all description and scrapping and properly cleaning of the surface to remove loose particles with wire brushesn incl demolition of old padding complete all as specified and directed. 34 M &L for PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregrate laid over roof slab after applying cement slurry for filling undulationations finished even and smooth without using extra cement complete all as specified and directed. 35 M&L screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:4, over RCC roof slabs / chajja for laying water proofing treatment mixed with using Approved water proofing liquid @ 150 ml per bag of cement complete all as specified and directed by Engineer-in-Charge.(Note : Water proofing liquid shall be measured and paid separately) 36 supply ofIntegral water proofing Liquid complete all as specified and directed. 37 M&L for cleaning of roof slab including picking, sweeping clean and washing down with water to remove dust, dirt etc and Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over cold applied bituminous primer conforming to IS 3384 @ of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer’s instructions, complete all as specified and directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, applied@1.20 Kg/Sqm over a coat of cold applied bituminous primer conforming to IS:3384 @ 0.40 Kg/Sqm. (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii)The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv)In case of stone masonry parapet wall etc a groove of size 25mmx25mm (minimum) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimney/other vertical surfaces and polymeric membrane inserted in groove and sealed with paving bitumen. (v) Cost of above aspects is deemed to be included in quoted rates. 38 Taking down chowkats or frames not exceeding 1.5 Sqm each with shutter (without taking off shutter from the frame) including iron mongry and removing from site complete all as specified and directed. 39 Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutter (without taking off shutter from the frame) including iron mongryand removing from site complete all as specified and directed. 40 Taking down shutter of any description exc. 1 sqm but n.exc 2 sqm eachincluding iron mongry and removing from site complete all as specified and directed. . 41 S & F 35mm thickIInd Class Hard wood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treatedcomplete all as specified and directed. 42 S & F 35mm thick IInd Class Hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed. Note :- S & F Glass/gauge shall be measured and paidseparately 43 S & F for Factory made Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing as applicable to item 08095 given in SSR Part – II (2020) complete all as specified and directed. 44 S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppy and fixing in the frame at site complete all as per specifications and drawings as applicable to item 08080 given in SSR Part – II. 45 Easing of steelwindow / ventilator (area n. exceeding 1.00 sqm) cleaning throughly and greasing the shutter hinge and handle complete all as specified and directed. 46 S & F for steel windows conforming to IS-1038 with side hung shutters including box type hinges with 2 Nos MS 100mm size tower bolt over MS flat iron for each openable leaf & Z section handle and steel peg stay complete with glazing bars, guard bar,tower bolt, dovetailed or weldedcomplete all as specified and directed.Note :-(i) Window size and pattern wherever required and directed by engr -in chage(ii) Glass / gaugeshall be measured and paid for separately). 47 S&Fsteel ventilator with top hung shutter and bottom fixed type shutter including hinges, steel peg stay, guard bar complete all as specified and directed. 48 Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. 49 S&F 3 mm thick sheet glass ordinary quality n exc 0.5 sqm each pane complete all as specified and directed. 50 Supply only Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed. 51 S&F in renewal of Stainless steel wire cloth, 0.36mm nominal dia of wire & average width of aperture 1.40mm & fixed to wodden door shutters complete all as specified and directed. 52 Supply only Stainless steel wire cloth, 0.36mm nominal dia of wire & average width of aperture 1.40mm & fixed to wodden door shutters complete all as specified and directed. 53 S & F 250 mm long Stainless steel, sliding door bolt with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded section & fixing blots & sliding bolts of extruded section or cast stainless steel alloy & fixed complete all as specified and directed. 54 S & F Stainless Steel butt hinges 100mm size, fixed with screws complete all as specified and directed. 55 S & F Stainless steel pressed handles, oval type, 100mm size fixed with screws complete all as specified and directed. 56 S & F Stainless steel pressed handles, oval type,150mm size fixed with screws complete all as specified and directed. 57 S & F Stainless steel barrel tower bolts, , with bright bolt and fixed tower bolts of extruded section, 200mm long complete all as specified and directed. 58 S & F of300mm, ordinary rat tail rod patternMild steel springs including roller and roller plate complete all as specified and directed. 59 M & L cutting holes in stone masonrywalls in cement mortar for inserting holdfasts & making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed. 60 M & L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and fastening and fixing complete FE 290 Gde E-165 complete all as specified and directed. 61 Demolition of stone slabs of any description or thickness in floors, aprons etc incl removal of demolished material exc 1.5 km to 5 km complete all as specified and directed. 62 M&L for Granite15- 16 mm thick (of any type) work (table rubbed and polilshed) in steps, jambs, pillars, window-cills, cooking platforms and like neat cement slurry including pointing in white cment (1:2) using marble dust with admixture of pigment to match with shade of granite over & including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed. 63 M&L for polishing / grinding / finishing of old existing marble /granite / Kota stone flooring where ever required to give high gloss finish complet all as specified and directed. 64 M&L for machine cut kota stone slab flooring 20-25mm thick in floor over 20mm thick cement screed bed of CM (1:4 ) laid and jointed with grey cement slurry mixed with pigment to match theshade of the slab including rubbing and polishing complete all as specified and directed. 65 M & L for 18 to 20 mm thick machine cut Kota stone in risers of steps, skirting, dado and pillar laid on and including backing layer of 10 mm thick in cement mortar 1:4, laid and jointed, pointed with grey cement slurry, mixed with pigments to match the sheds including rubbing and polishing complete all as specified and as directed. 66 M & L framed work such as grills, gratings, etc., with ends of bar shoulder &/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks with Angle, MS sheet Flat iron & similar work conforming to Fe 290 GDE -E-165 complete all as specified and as directed. 67 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required & dismantling of old kerb stone complete all as specified and as directed. 68 M&L for preparation of newly plastered surfaces of wall andapplying Two or more coatsof 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.Make :- ASIAN (Ultima Protect/ Nerolac Excel 12/ Berger Life long 10). 69 M& L for complete removal of existing treatment on old plastered surfaces of walls andapplying Two or more coatsof 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on wall /concrete surface complete all as specified and directed. Make :- ASIAN Ultima Protect/ Nerolac Excel 12/ Berger Life long 10).Note - The work will be carried outin RCC OHT & heightapprox 18 to 25 m & cost of this aspects is deemed to be included in quoted rates. 70 M/L for Complete removal of existing treatment of old plastered surfaces of walls andapplying Two or more coatsof 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. 71 M&L for preparation of newly plastered plastered surface ofwalland applying two coat of Cement Base Paintwhite or tinted of approved shade complete all as specified and directed. 72 M&L for preparation of old plastered or unplastered surface ofwall including cornices etc. by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and removal of vegetation and applying two coat of Cement Base Paintwhite or tinted of approved shade complete all as specified and directed. 73 M& L for complete removal of existing treatment on old plastered surfaces of walls & applying two coats of distemper oil emulsioncomplete all as specified & directed. 74 M & L for preparation of newly plastered surfaces& applying two coats of distemper oil emulsion on ceilings / walls complete all as specified & directed. 75 M& L for complete removal of existing treatment on old plasteredsurfaces of ceiling& applying two coats of distemper oil emulsion on ceilings / walls complete all as specified & directed. 76 M&L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coatof red oxide zinc chrome primer complete all as specified anddirected. 77 M&L for preparation of new or previously untreated wooden or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over and including one coatof pink primer complete all as specified and directed. 78 M&L preparation old untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over complete all as specified anddirected. 79 M&L for preparation of old painted wooden or wood based surfaces of any description over 10 cm in width or girth when unconnected with other painting or when painted in a diferenttint and applying two coat of synthetic enamel paint over complete all as specified and directed. 80 S& F PVC (SWR) vent cowls for 110 mm bore complete all as specified and directed. 81 S&FPVC (SWR) 75mm dia of outlet floor trap, plain with grating including jointing with solvent complete all as specified and directed. 82 S&F in repairs vitreous china wash basin with pedestal white flat back size 550x400 mm including 32 mm dia connector, 32mm size waste fittings, brass chromium plated, waste pipe, with long screwed shanks and fly nuts, flange end, bedded in red lead cement and other fixed complete including cutting for and pinning in ends of bracket or erecting stand etc complete all as specified and directed. 83 S&F in repairs vitrous china squatting pan orrisa pattern, size 580x440 white with integral foot rests or out going pipe and toflushing pipe, antisyphonage pipe etc complete all as specified and directed. 84 S & F 110mm PVC (SWR)sanitary connection socket to fit WC out-letcomplete all as specified and directed. 85 S&F in repairs, PVC low level cistern 10 litres capacity, valve less, symphonic action type with float, handle including 32mm dia PVC flush pipe of polyethylene of low or high density & bracket etc complete all as specified and directed . 86 S&F in repair bib taps 15mm bore standard of PTMT any colour high pressure screwed for Iron pipe and fixed. (Minimum weight 15mm-90gm screwed for iron pipe or forunion etc complete all as specified and directed. 87 S & F in repairs 15mm bore PVC connections, with PTMT nuts of length 450mm complete all as specified and directed. 88 S&F in repair 15mm bore angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms) for iron pipe or for union complete all as specified and directed. 89 S&F in repair 20mm bore stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed. 90 S&F 500 litres,Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top, white in colour) hoisted and fixed in position all as specified in SSR Part complete including taking down old unserviceable water tank all as specified and directed by Engineer-in-Charge.Note : PVC tanks shall be ISI marked and minimum three layar. 91 S&Fin repairs 20mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and directed. 92 S & F in repairs15 mm bore Pillar tapsfancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without letteredwith long screwed shanks and fly-nuts, screwed for ironpipe and fixed complete all as specified & directed. 93 Dismantling RCC/Wooden fencing Post any section, including taking out embedded portion and making good disturbed ground; posts embedded in natural ground complete all as specified and directed. 94 Dismantling fencing wire mesh, any typecomplete all as specified and as directed. 95 Dismantling structural steel work including doors, gates, postbut excluding framed truss etc complete all as specified and directed. 96 Excavating in post holes (or similar holes) each n exc 0.5 cu. m, and getting out, in soft / loose soil, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, making good complete all as specified and directed. 97 M & L for MS work such as angle iron fencing post struts and flat iron fillets etc of grade Fe 290 Gde E-165 ISI marked including drilling holes punching, splitting ends to secure chain link fencing or fixing of barbed wire to post including all necessary cutting, welding, drilling, bolting or riviting etc complete all as specified and directed. 98 M & L for 1:2:4 ,type D2,, 40 mm graded aggregate as in foundations , fillings & mass concrete etc for post hole complete all as specified and directed. 99 Supply only Chain link fencing of MS GI wire mesh of size 100 x 100 mm, 4 mm dia of GI wire made upto into mattresses or cages, lapped wired including staple etc, ISI marked (IS-2721) complete all as specified and directed. 100 Fixing only Chain link fencing of any mesh size or any type including line wire to any type of standard rails/supports etc and straining bolts etc including provision of binding wire complete all as specified and directed. 101 S & F MS Screw bolts with hexagonal or square head at one end and screwed the other end or screwed both ends, each washers and one hexagonal square nut length of bolts shall not exceed 5cm dia of bolt shall be 5-10mm complete all as specified and directed. 102 Supply onlyMild steel round bars conforming to Gde I (IS: 432 part-I) 10mm dia and over, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia as in chain link fencing complete all as specified and directed. 103 S & F Galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to angle iron securing or laying at crossing etc complete all as specified and directed. 104 M&L for painting to steel surfaces of any description not exceeding 10cm width orgirth with two coats of synthetic enamel paint over one coat of zinc chromate primer when uncon-neeted with other painting or when painted in bar of fencing/ flate iron including preparation of new steel surfaces etc. complete all as specified and directed. 105 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. 106 Returning, filling including spreading, levelling, watering and ramming in layers not exceeding 25cm thick complete all as specified and directed. 107 Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. 108 M & L for cement concrete in foundation, mass concrete type D-2 1:4:8 (40mm graded crushed stone aggregate) complete all as specified and directed. 109 M & L for form work to sides of concrete foundations, footings, bases of columns, sides & soffits of foundation and plinth beams and similar work for rough finished flat surfaces of concrete complete all as specified and directed. 110 M & L for form work to sides of square or rectangular columns, pillars, posts and struts for rough finished surfaces of concrete complete all as specified and directed. 111 M & L for RCC nominal mix(using 20 mm graded crushed stone aggregates) as in foundations, footing, plinth beams, bases for columns and mass concrete complete all as specified and directed.Note :- Reinforcement to be measured and paid separately under appropriate item of BOQ. 112 M & L for RCC nominalmix(using 20 mm graded stone aggregates) in columns, pillars, posts & struts complete all as specified and directed.Note :- Reinforcement to be measured and paid separately under appropriate item of BOQ. 113 S & F of mild steel TMT bars 5 to 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. 114 S&F in renewal of sign boards with stainless steel frame of any required size with3mm thick ACP sheetsone side visibility with digital art work (letter, numbers, signs, symbols etc) reflective type incl necessary electric arragement as deemed necessary. frame pole shall be fix in PCC(1:2:4) , 20mm graded stone aggregate complete all as specified and directed.Note - (i)Writing letter, numbers, signs, symbols etc deemed to be included in quoted rates.(ii)SS frame shall be measured and paid separately under appropriate item of BOQ. 115 Material & Labour for providing and fixing stainless steel (Grade 304) railing/ frame made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing/ frame with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size and location complete all as specified and directed. 116 M&L for taking downrolling shutters, cleaning thoroughly,greasing the moving parts like ball bearing,Helical springs,guide channels ets of the existing rolling shutters including making straight guide channel and replacing the damaged parts if required like spring,ball bearing etc to make the rolling shutter fully functional complete all as specified and directed. 117 S&F steel rollingshutters without ball bearing including top cover anchoring rod,hasp and staple including all necessary fitting and one coat of primer, erected in position push pull or mannual type thickness of laths 1.00 mm including taking down old unserviceable rolling shutters complete all as specified and directed. 118 S&F of safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed. 119 Dismantling plain or corrugated steel sheeting any gauge thickness including nanital or similar pattern roof covering complete all as specified and directed. 120 M & L Steel work as in trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 complete all as specified and directed. 121 S&F pre painted galvalume aluminium zink coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and washers as specified.
|