Tender For Special Repair To Bldg No P-811, T-524, T-525 And T-345 At Mil Station Sgnr.; 1 Dismantlingwall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed. 2 Dismantling Plain or corrugated steel sheeting, any gauge,thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. 3 Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc, including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed. 4 S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. 5 S&F mild steel roof trusses (framed), trussed, purlins, crane gantries, rails, cleats and fastenings and heaving bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats and brackets etc complete all as specified and as directed. 6 S&F 0.63mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed. 7 Demolition of brick work built in cement mortar of any descriptioncomplete all as specified and as directed. 8 M&L for brick work with fly ash bricks (old size), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed. 9 Taking down cement plaster on internal/external brick or concrete wall etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed. 10 M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in CM 1:4 in two layers of 10mm and 5mm , 2nd layer 5mm is to be mixed with integral water proofing compound and finished fair and even without using extra cement as external plaster on walls complete all as specified and as directed.Note : Water proofing compound shall be measured and paid seperately under respective items of this BOQ. 11 M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in CM 1:6 finished even and smooth without using extra cement as internal plaster on walls complete all as specified and as directed. 12 Supply only Integral water proofing compound (WPC), conforming to IS and as approved, complete all as specified and as directed. 13 M&L for preparation of new plastered surfaces of external walls and applying two coat of exterior emulsion paint (weather coat) over a coat of alkali resistance primer and one coat of 1mm thick wall care putty for finishing the surfaces smooth complete all as specified and as directed. 14 M&L for preparation of new plastered internal wall surfarces & applying two coat of interior acrylic emulsion over a coat of alkali resistance primer and one coat aof 1mm thick wall care putty for finishing the surfacing smooth complete all as specified and as directed. 15 M&L for preparation of old painted steel surfaces over 10cm width or girth and applyibg two coat of synthetic enamel paint complete all as specified and as directed. 16 M&L for prepariont of new steel surfaces over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. 17 M&Lfor 100 mm thick cement concrete 1:4:8, type D2 (Using 40mm graded stone aggregate) as in fillings/ mass concrete and sub floors etc complete all as specified and as directed. 18 M&L for 60mm thick (M-35 grade)Machine pressed precastrubber moulded concretecoloured interlocking paver block any shape and size confirming to IS 15468-2006with grey cement and pigment complete all as specified and as directed. 19 M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. 20 M&L for anodised aluminium snap grid frame work for false ceilingincluding Gypsum Board 12mm thick in ceiling fixed with hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm longincluding painting with two coat of interior acrylic emulsion over a coat of primer etc complete all as specified and as directed. 21 S&F anodised aluminium grill, having mesh size 75mmx75mm made out 4mm wide and 3mm thick aluminium section with MS hooks of 6mm round bars two numbers each side insert into the jambs/cill complete all as specified and directed including taking down old existing grills of any pattern and size complete all as specified and directed. 22 M&L for complete removal of existing treatment and finishing the walls with textured exterior paint of required shade new work two or more coats applied @ 3.28 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20kg/10 sqm complete all as specified and as directed. 23 S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed. 24 Supply and fixing door closer hydraulically regulated designation No. 2 universal type aluminium body, (diecast) suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 Kgs complete all as specified and as directed. 25 S&F mild steel Mortice lock, vertical type, size 100 mm, 4 lever complete all as specified and as directed. 26 Taking down chowkhats or frames with shutter (without taking off shutters from the frame ) exc 1.5 Sqm but not exceeding 4 sqm each complete all as specified and as directed. 27 Taking down steel window / ventilators of any size and pattern complete all as specified and as directed. 28 M&L for powder coatedaluminium frames for doors, windows withone or moe rebates including jointing cleats for fixing etc.including powder coating minimum (thickness of powder coating shall be 50 micron) complete all as specified and as directed. 29 S&F in repair powder coated anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed. 30 S&F powder coated aluminiumwindowsand ventilator shutters,side hung type, without sash bars aluminium saction weighing 0.55 kg/RM including necessary jointing cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fitting such as peg stay 150mm long (1 no) hinges type B21 100 mm long (2 No) suitable handle (1No) complete all as specified and as directed. 31 S&F 5.0mm sheet glass ordinary quality and glazing with oil putty in square exc 0.5 sqm in each plane complete all as specified and as directed. 32 S&F 4.0 mm thick figured glass, pin head type and glazing with oil putty or fixed with beads in suqares n.exc 0.5 Sqm in each pane complete all as specified and as directed. 33 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. 34 M&L for Double Charged, Stain free Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tile exceeding 0.42 sqm but n exc 1.00 Sqm in floors etc. set and jointed in neat cement slurry and pointed in epoxy groute to match including 15mm thick screed in CM 1:6 complete all as specified and as directed. 35 M&L for Double Charged, Stain freeVirified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tile exceeding 0.42 sqm but n exc 1.00 Sqm in skirting/dado etc. set and jointed in neat cement slurry and pointed in epoxy groute to match including 15 mm thick rendering in CM 1:4 complete all as specified and as directed. 36 M&L for granite (of any type) 16 to 20 mm thick(table rubbedand polished) in cooking platforms and like in cement mortar 1:4including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 15mm of screed bed in CM 1:6 complete all as specified and as directed. 37 M & L 20mm thick Granite (of any type) tiles machine cut, in skirting /dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete including 15mm of screed bed in CM 1:4 complete all as specified and as directed. 38 Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed. 39 S&F flat ironfor wind ties,plates (plain or chequered) channels, posts, square cut or notched (ordinary and counter sunk) forming holesetcFe 410 -W (Gde- E- 250) quality- A complete all as specified and as directed. 40 S&F mild steel screw bolts (machine made) with hexagonal or square head at one end, and screwed the other,or screwed bothend to be fitted with washer and one hexagonal/ square nut not exceeding 5cm long and dia of neck 11 to 15mm complete all as specified and as directed. 41 M&L for light shade Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed in CM 1:6 complete all as specified and as directed. 42 M&L for preparation ofnewly plastered surface of wall any description and applying twocoats of interior acrylic emulsion over1 mm thick wall care putty over a coat of chalk whiting layer on plastered surfaces preparatory complete all as specified and as directed. 43 M&L for preparation of new plastered surfaces of wall and applying two coats of exterior acrylic emulsion over 1mm thick wall putty over one coat of alkali resistantprimer complete all as specified and as directed. 44 M&L for preparation of old surface including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and removing all dirt and dust by watering making surface even and smooth and then applying two coats of exterior acrylic emulsionover over1 mm thick wall putty well prepared old decorated plastered surface etc complete all as specified and as directed. 45 M&L for preparation of old decorated wall surfacesby brooming down or steel wire brushing,scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spotsand then applying two coat of interior acryulic emulsion over1 mm thick wall puttycomplete all as specified and as directed. 46 M&L for preparation of old painted wooden surfaces of any description over 10cm width or girth not otherwise described and applying onecoats of synthetic enamel paint complete all as specified and as directed. 47 S&F solidPVC wall Lining consisting of 5mm thick plain colour PVC sheetinclusive of solvent cement and fixing at site on PVC including 5 mm thick PVC sheet fillet of width 35 mm for wall panelling inclusive of fixing to wall to makwe PVC frame as per specification and drawing complete all as specified and as directed. 48 Demolition of reinforced cement concrete of any description and in any position not other wise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and as directed. 49 M&L providingreinfoced cement concrete (nominal mix) in cement concrete 1:2:4 Type B1(20mm graded aggregate)as chajjasetcand similar workcomplete all as specified and directed by Engineer-in-Charge.(Note : The rate quoted shall be deemed to include use and waste of necessary form work) complete all as specified and as directed. 50 M&L TMT bar 10 mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed. 51 M&L for brick work with sub class "B" bricks (old size) straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and as directed. 52 All as per Srl item No. 51 except bricks complete all as specified and as directed. 53 Taking down carefully aluminium point wiring (light, fan, socket or power, bell complete fitting such as sockets, ceiling roses, pendants, batten holders, regulators and making good the disturbed surfaces of wall, floors, ceiling in CM 1:3 etc complete all as specified and directed. 54 M & Lfor concealed conduit point wiring complete for light/ fan on independent /combine boardwith cable 1.5 sqmm (Nominal area) FRLSHPVC insulated multistranded unsheathed copper conductor,drawn in and includingPVC Concealed conduitpipe medium grade 20 mm dia, pipe hooks , elbows, juction covers and junction boxes , aftercutting in wall chasing for conduits and sinking"s for GI metal flush boxes suitable lengthandthickness alongwith 3mm thick sheet for mounting, switches, sockets,fan regulatorwith cover plate with frame and making the gooddisturbed surfaces of wallin CM 1:3 with white wash or existing colour including provision ofcontinuousearth continuity conductoralong with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switchand connected to commonearth dolly,complete all as specified and directed. 55 All as per Srl item No -54 here in before but for one switch socket combination5/6 amp on independent board complete all as specified and directed. 56 All as per Srl item No -54 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed. 57 All as per Srl item No. -54 here in before but for one switch socket combinationt 6 pin 5/ 15 Amps on independent board with copper conductor 2.5 Sqmm alongwith 2.5 sqm earth continuity conductor complete all as specified and directed. 58 S & F switch piano flush type 5/6 Amps single pole one way complete all as specified and directed. 59 S & F switch socket combination 5 pin, type 5/6 Amps flush type complete all as specified and directed. 60 S & F switch socket combination 6 Pin, 5/16 Amps flush type complete all as specified and directed. 61 S & F Socket outlet 5 pin 5 Amps flush type complete all as specified and directed. 62 S & F ceiling rose surface bakelitethree terminalscomplete all as specified and directed. 63 S & F in replacement of existing light fitting withLED batten W LED batten with "Eye Soft" technology & glarefree diffuser for perfect application in modern homes or aliminium housing andintegrated electronic driver,20 watt having input voltage AC90-300V, 50 Hz , 6500K, and all other accessories including connection with flexiblecable copper conductortwin coreof size 23/.2 mm upto ceiling rose/connector complete all as specified and directed. 64 S&F security light fitting LED TYPE 25 watt with all necessary acessories, Clear transparent acrylic cover, prewire suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed. 65 Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. 66 S&F Decorative, wall insulated body with back plate for conduit fittings complete all as specified and directed. 67 S & F angle holder insulated body with back plate for conduit fittings complete all as specified and directed. 68 S&F LED lamp 9W for angle holder complete all as specified and directed. 69 S & F in repair compact & decorative energy efficient LED mirror light fitting with antiglare diffuser and decorative end caps suitable for 1X10 watt fitting 2 ft version including LED lamp 20 watt complete all as specified and directed. 70 S & F in replacement recess mounting 2 x 2 feet 36 watt LED luminaire with powder coated CRCA housing with LEDs seamless front frame with high transmission acrylic cover and fixed electronic driver (surge protector) all as specified and directed. 71 S&F metal body exhaust fan of 300 mmsweep ,230 volt, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVCsheathed copper conductorflexible cable 24/0.2mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to distubed wall in cement mortar (1 :4) white washing matching with existing colour etc complete all as specified and directed. 72 S&F exhaust fan made of sturdy engineering plastic of 250mm sweep 240 volt complete with louvers and shutter and mounted in suitable opening arrangement in wall and connectiong up including 3 core PVC insulated PVC sheathed coper conductor flexible cable 24/0.2mm from ceiling rose to fan complete including breakign of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to distubed wall in cement mortar (1:4) white washing matching with existing colour etc. comlete all as specified and directed. 73 S & F stepped type fan regulator not less than 120 watt for ceiling fan 1200/1400m sweep complete all as specified and directed. 74 S & F in replacement of sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLSH stranded copper conductor drawn in and including steeldia 25mm “medium quality” conduit including 6.00 Sqmm (Nominal Area) copper cableas earthcontinuity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and coversincluding necessary connections, PVCflexible pipes are used in pannel board while connecting the cable complete all as specified and directed. (Note : PVC cable and PVC conduit shall be ISI marked.) 75 S & F in replacement of sub-main two single core PVC copper conductor unsheathed wire multi stranded 4 sqmm FRLSH inlcluding cutting chasing and grouting PVC pipe including Tee, Elbow, Bend etc and inlduing 4.00 sqmm copper conductor single core wire connected by common earth all sepcified inlduing 20mm dia concealed PVC conduite, medium grade, ISI marked complete all as specified and directed. (Note : PVC cable and PVC conduit shall be ISI marked.)(Note : Two lengths of 4.0 sqmm cable and one length of 4.0 sqmm earth cabel alongwith PVC conduite will be measured as one running length) 76 Taking down fan, ceiling cable end, dismantling blades and removing fan sand blades to store complete all as specified and directed. 77 M&L for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed. 78 Hanging only ceiling fan (M.D. Supply) and connectiong up including provision of cable from ceiling rose or connector to fan complete all as specified and directed. 79 S&F ceiling fans AC single phase 230/240 V of size 1200mm sweep without regulator having Min air delivery 210 CFM with services value 6.00 BEE 5 star rated with brushless direct current motor (BLDC) complete with electrical connection providing three core round flexible copper conductor cable of suitable size complete all as specified and directed. 80 S & F sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 ways, 240 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed. 81 S & F sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted TP & N 4 ways, 415 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed. 82 S & F MCB ‘C’ series type suitable for 240 volts, AC supply 40 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. 83 S & F MCB ‘C’ series type suitable for 415 volts, AC supply 40 Amps, T P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. 84 S & F MCB ‘C’ series type suitable for 240 volts, AC supply 32 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. 85 S & F MCB ‘B’ series type suitable for 240 volts, AC supply5/6 to 32 Amps , single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. 86 S & F MCB ‘B’ series type suitable for 415 volts, AC supply25 to 63 Amps , three pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. 87 M & L for Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mmthick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of plate not less than 1.5 Mtr below ground level , connecting to GI earth lead 4 mm dia GI earth wire ,by means of bolts,nuts and washers of GIand protection by provisionof GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20 mm grade stone aggregate with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 gs /Sqmm ) and frame of angle iron 25mmX25mmX6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape ,GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed ontop edge of earth plate common salt and charcoal filling test point made out of 40 mmX 8 mm FI with fixing arrangement ,funnel, wire mesh and earth work inhard dense soil ,returning filling in and removal of surplus soil to a distance not exceeding50 mtrs all as per electric plate no.3 of SSR part 1 and connecting to earth test point including taking out unserviceable earthing with all acessories all as specified or indicated including testing on completion all as specified and directed. 88 Taking down and refixing wall mounted fan 400mm sweep, 240 volt complete al specifeid and directed. 89 Taking down and refixing of air circulare complete al specifeid and directed.
|