Providing Street Light At Village-Jaitpur, Yea Providing Street Light At Village-Jaitpur, Yea Wc-( E M -02) - Street Light Supply and erection of 8.5 M. long P.C.C. pole, confirming to IS 1678-1960, IS 343-1960 and IS 456-1964 grouted with 1:4:8 cement concrete (1 cment, 4 fine sand : 8 over burnt brick ballast of 40 mm nominal size) including the plinthing of pole. Complete with all material, labou, T&P etc. and also including cartage of pole from store to site of works. complete in all respect, as per the directions of the Engineer-in-charge.YEIDA SOR-33 2 Supply and fixing ofLED Street light Fittinghaving die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt. Confirming to IP 66protection complete in all respect (Bajaj, Crompton , Philips) PWD-2018 PS No-1421 Cat-AAA 3 S/E of ‘D’ clamps 50X6mm. flat iron on steel tubular pole / steel rail pole with bolts, nuts etc complete in all respect including with aluminium paint. PWD-2018 PS No-623 4 Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect.25amp TPN PWD-2018 PS-807 5 Supply, delivery, testing, laying of Al. conductor HDPE/XLPE insulated 1100V grade Arial Bunched Cable with Messenger wire as below on pole complete in all respect. (CCI, Gloster, Asian, Universal, NICCO, ICL, Diamond, Havells, Kalinga, Suraj, Delton Grandley & Polycab, make) Complete in all respect, as per the directions of the Engineer-in-charge. YEIDA SOR-76 (a) 2CX25 Sqmm. + 25 Sqmm. 6 Supply, delivery, testing, laying of Al. conductor HDPE/XLPE insulated 1100V grade Arial Bunched Cable with Messenger wire as below on pole complete in all respect. (CCI, Gloster, Asian, Universal, NICCO, ICL, Diamond, Havells, Kalinga, Suraj, Delton Grandley & Polycab, make) Complete in all respect, aas per the directions of the Engineer-in-charge.YEIDA SOR-76 (b) 3CX50 Sqmm. + 25 Sqmm+35 Sq mm. 7 S/F of 16sqmm. to 50 sqmm. L.T. A.B.C. connector on pole, complete in all respect.as per the directions of the Engineer-in-charge.YEIDA SOR-36 8 S/F of 40mm. dia 1.5mtr. Long G.I. pipe ‘B’ Class bracket with 2 Nos. ‘D’ clamps 50X6mm. flat iron on steel tubular pole / PCC pole with bolts, nuts etc. complete in all respect, as per the directions of the Engineer-in-charge. YEIDA SOR-35 9 S/F of palm or pin type copper tin plated cable socket (Lug) to the cable leads, insulating with tape & making connections etc. complete in all respects as per the directions of the Engineer-in-charge. PWD-2018 PS No-504 (a) 25 Sqmm. 10 S/F of palm or pin type copper tin plated cable socket (Lug) to the cable leads, insulating with tape & making connections etc. complete in all respects as per the directions of the Engineer-in-charge. PWD-2018 PS No-504 (b) 50 Sqmm. 11 Supply & Fixing of XLPE insulated, Copper un-armoured Control cable 1100V grade etc. Complete in all respects as per the directions of the Engineer-in-charge. make- CCI, Gloster, Asian, Universal, Nicco, ICL, Diamond, Havells & KEI YEIDA SOR-1 a) 3CX1.5 Sqmm. 12 Supply & fixing of L.T. Junction box on pole suitable for out door type operation of size 400x300x200 mm made of 3.0mm CRCA sheet complete in respect as per Annexure. Analysis of Rates 13 Supply & erection of screw tightener complete in all respect, as per the directions of the Engineer-in-charge.YEIDA SOR-37 14 Supply & fixing of stay insulator with stay wire complete in all respect,as per the directions of the Engineer-in-charge.YEIDA SOR-38 15 S/E of stay set at least 3.5 mtr away from the pole complete with galvanized 19mm dia x 1.800 mtr long stay rod. 30cmx30cmx6.3mm anchor plate thimble stay clamps, stay insulator 19mmx600mm double screw tightener. 7/4.00 mm G.I. stay wire etc. in1:3:6 cement concrete in all respect.as per the directions of the Engineer-in-charge.PWD-2018 PS No- 630. 16 Numbering of poles with combination of yellow and black colour paint etc. complete in all respects aas per the directions of the Engineer-in-charge.Analysis of Rates 17 HT Network Supply & erection of Steel tubular pole with 1/6 over all length of pole grouted with cement concrete in 1:3:6 (1 cement : 3 coarse sand : 6 stone ballast) including plinthing of pole 30 cm above the ground level, plastering of plinth including excavation back filling etc. The rates includes all materials labour & T&P. etc. required for proper completion of work as per direction of E/I. d) 410 SP-55, 11mtr. (Approx. wt. 232kg.) YEIDA SOR-24 18 S/F of HDPE. pipe 200mm dia PE-63/PN-4 including required material, T&P etc. complete in all respect, as directed by Engineer in chargeYEIDA SOR-19 19 S/F of 11 KV Polymeric pin insulator with pin on poles or anywhere specified including bolts to fasten on pole cap/cross arm with the poles.(Jaishree, BHEL,RR, Hindustan, Yamuna, AD, make) Complete in all respect, as per the directions of the Engineer-in-charge.YEIDA SOR-78 20 S/F of cross arm made of 100X50X6 mm M.S. channel 2.5 mtr. long on poles with packing, piece, M.S. clamp, Nut bolts etc. complete in all respect, as per the directions of the Engineer-in-charge.YEIDA SOR-30 21 Supply, Sagging, tensioning, jointing and bending of suitable size ACSR conductor conferming to I.S. specification including cost of aluminium wire and jointing sleeve required. The rates includes cost of material, labour, T&P etc. required for proper completion of work as per the directions of the Engineer-in-charge.PWD-2018 PS No- 627, a) Wesele conductor. 22 Supply & fixing of MS rod for earthing with 2.5 m long, solid, 20 mm dia hot dipped galvanised MS rod buried till the top reaches 1.7 mts. Below the GL complete with bolts & nuts & GI earth wire 7/14. Complete in all respects as per direction of the Engineer-in-charge. YEIDA SOR-52 23 S/E of stay set at least 3.5 mtr away from the pole complete with galvanized 19mm dia x 1.800 mtr long stay rod. 30cmx30cmx6.3mm anchor plate thimble stay clamps, stay insulator 19mmx600mm double screw tightener. 7/4.00 mm G.I. stay wire etc. in1:3:6 cement concrete in all respect.as per the directions of the Engineer-in-charge.PWD-2018 PS No- 630. 24 S/F of 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 Mtr. below ground level complete with 20 mm dia G.I. pipe & funnel for watering & one earthing lead of one no. 8 to SWG GI wire in 15mm dia G.I. pipe upto switch board (from apron to switch board the cost of GI pipe and GI wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of char-coal/coke & salt atleast 150 mm thick all-around etc. as per direction of Engineer-in-charge complete in all respects. PWD-2018 PS No-PS-702 25 Supply and laying of 25mmx3mm G.I. strip from earth electrode directly in the ground as required complete in all respect.as per the directions of the Engineer-in-charge.PWD-2018 PS No-716 26 S/F of 11 KV TPMO set of ‘Relco’ make or equivalent with insulators and other accessories required for proper completion of work.aas per the directions of the Engineer-in-charge.YEIDA SOR-56 27 S/F of 11 KV Drop-out type fuse set channel type of ‘Relco’ or equivalent make with insulators and other accessories required for proper completion of work.as per the directions of the Engineer-in-charge.YEIDA SOR-57 28 Supply, Installation, testing and commissioning of Outdoor type distribution transformer. Specification and also confirming to IS: 1180. Level-2as per the directions of the Engineer-in-charge.(a)63 KVA Aluminium wound YEIDA SOR-34
|