Tender For Provision Of Rewiring In Md Accommodation At Nams.; 2 LIST OF WORKS FOR BUILDING WORKS 3 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed 4 Material and labour for glazed ceramic coloured tiles of size 450mm x 350mm x 7mm thick on vertical surface skirting, dados, risers to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, over and including rendering 10mm thick in cement mortar (1:3) complete all as specified and directed 5 Material and labour for Non-Skid ceramic colour tiles 7 to 8mm thick (Square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed 15mm thick rendering in CM 1:6 complete all as specified and directed 6 Taking up or down steel tubing and connections including cleaning for refixing or removeal to store for 15mm bore of pipe complete all as specified and directed 7 Taking up or down steel tubing and connections including cleaning for refixing or removeal to store for 20mm bore of pipe complete all as specified and directed 8 Supply & laying of CPVC pipes 20mm outer dia,SDR 11 & Plain CPVC SDR 11 fitting on wall/ ceiling or laying in floorsincluding all necessary fittings conforming to IS complete all as specified and directed 9 Supply & laying of CPVC pipes 25mm outer dia,SDR 11 & Plain CPVC SDR 11 fitting on wall/ ceiling or laying in floors including all necessary fittings conforming to IS complete all as specified and directed 10 Supply and fixing in repair, for 15mm bore fancy type central hole basin mixer with 135mm extension body fixed spout without popup waste system with 350mm long braided hoses of 15 degree flow angle complete all as specified and directed 11 Supply and fixing in repair, chromium plated single lever wall mixer 3-in-1 with connector for hand shower arrangement with connecting legs, wall flanges and wall brackets for hand shower complete all as specified and directed 12 Supply and fixing in repair, White Vitreous China wash down water closet one piece closet with integrated cistern, seat cover and twin flush fittings complete all as specified and directed. 13 Supply and fixing in repair, Vitreous China Wash Hand Basin, white, flat back, size 550 x 400 mm including brass coupling, mild steel brackets fixed to wall with pedestal etc. complete all as specified and directed. 14 Supply and fixing in repair, 8 mm dia brass, chromium plated health faucet (Hand shower) with 01 meter long flexible tube and wall hook complete all specified and directed. 15 Supply and fixing sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified 16 Supply and fixing in repair chromium plated glass corner (Corse) size 300mm x 300mm complete all as specified 17 Supply and fixing in repair looking mirror 600 x 450mm selected quality bevelled edges 5mm thick including aluminium frame mounted on 5mm thick block board including bracket and fixing arrangement complete all as specified and directed 18 Supply and fixing in repair, Bib tap 15 mm bore, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. 19 Supply and fixing in repair, PVC connection 15mm dia size and 450 mm long with 2 Nos check nuts with washers complete all as specified and as directed. 20 Supply and fixing PVC waste pipe 32mm bore of size 750mm to 900mm long complete all as specified and directed 21 Supply and fixing in repair, brass chromium plated tubular towel rail20 mm dia 60 cm long between flanges complete all as specified and directed. 22 Supply and fixing in repair, angle cock 15 mm bore fancy type chromium plated, with capstan head, high pressure, screwed down, screwed for iron pipe or for brass ferrule fixed to iron pipe complete all as specified and directed. 23 Supply and fixing in repair 15mm dia chromium plated concealed Angle/stop cock screwed down high pressure with crutch or butterfly handle & screw both end for iron pipe or for unions complete all as specified and directed 24 Supply and fixing in repair, CP, soap dish holder complete all as specified and directed. 25 Supply and fixing in repair, Soap Dispenser with glass bottle complete all as specified and directed. 26 Supply and fixing in repair, tumbler holder stainless steel complete all as specified and directed. 27 Supply and fixing in repair, chromium plated towel ring round with round flange of suitable size complete all as specified and directed. 28 Supply and fixing in repair, chromium plated overhead shower rose swivel type 125 mm with CP arms 300 mm long complete all as specified and directed 29 Supply and fixing in repair, chromium plated toilet paper holder with flap roll complete all as specified and directed. 30 Supply and fixing in repair, PVC (SWR) floor/ gully trap, square or round mounted, any type of size 125 x 100mm, setting and jointing with solvent cement (1:1) complete all as specified and directed 31 Taking down chowkats or frame with shutters of any description (without taking off shutters from the frames) not exc. 1.5 Sqm each complete all as specified and directed. 32 Supply and fixing factory made solid PVC moulded door shutter with wood free solid board, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 5mm thick 3D wood laminated moulded PVC sheet polyurethane painted on the front and back face with 19 gauge thickness using MS square tubing, supply and fixing of 19mm x 19mm frame structure complete all as specified and directed 33 Supply and fixing solid PVC door frame of size 95mm x 50mm made out of 5mm wooden grain colour, laminated both side colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed 34 Supply and fixing 100mm size butt hinges, mild steel cold rolled medium weight fixed screws to wooden frame or with welding to steel frame all as specified and directed 35 Supply and fixing aluminium handle cast type anodised 150mm size ISI mark complete all as specified and directed 36 Supply and fixing 100mm long aluminum anodised barrel tower bolts of extruded section and fixed ISI marked complete all as specified and directed 37 Supply and fix anodised aluminium powder coated frame any colour minimum coating 50 micron three track windows/ventilators with one or more rebates including joining cleat for fixing etc. complete and making good to disturbed surface with cement concrete 1:2:4 and cement mortar 1:4 complete all as specified and directed.Note :- Sheet glass, wire cloth, etc shall be measured and paid separately 38 Supply and fixing 4mm thick figured glass, pin headed type and glazing with oil putty in square n.exc 0.5 Sqm each panes complete all as specified and directed 39 E/M WORKS 40 Taking down carefully existing point wiring of any type (i.e. on wooden batten, surface conduit, casing capping or concealed conduit except existing concealed conduit) complete for light, fan, socket or power point with fittings and fixtures such as ceiling rose, electric fittings, holders, switches, sockets wooden batten, conduit etc including accessories such as wooden gutties/ rawal plug, screws etc including removing materials from site for taking credit of unserviceable items and re-fixing the serviceable items as per schedule and making good disturbed surface of walls, floors etc, complete all as specified and directed.Notes :-(i) The existing conduit of concealed wiring will not be removed from site and same will be reused for point wiring under respective item hereunder.(ii) The qty of serviceable/ unserviceable items will be ascertained by the BOO detailed by GE and serviceable items (such as LED fittings/LED tube and bulb /ceiling/ Exhaust Fans and geysers) will be re-fixed under respective item hereunder and unserviceable items such as switches, sockets, ceiling rose, holders, brackets, bulkhead fittings, LED fittings, MCB DBs, sunken boxes and fixtures etc. shall be issued to contractor under schedule of credit all as specified and directed. 41 Material and labour for point wiring with 1.5 Sqmm single core PVC insulated unsheathed copper FRLS multi stranded conductor cable in and including existing PVC conduit inclusive of tees, bend, elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc with white laminated 3mm thick hylam sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sqmm FRLS cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster with paint & including taking down existing point complete all as specified and directed for One light point controlled by one, one way switch 5 Amps. 42 Material and labour for point wiring with 1.5 Sqmm single core PVC insulated unsheathed copper FRLS multi stranded conductor cable in and including concealed PVC conduit of size not less than 20mm ISI marked inclusive of tees, bend, elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc with white laminated 3mm thick hylam sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sqmm FRLS cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster with paint complete all as specified and directed for One light/ fan/ exhaust fan point controlled by one, one way switch 5 Amps 43 All as per Srl item No. 41.00 here-in-before but one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board. 44 All as per Srl item No. 41.00 here-in-before but using 2.5 Sqmm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 Amps switch socket combination point including necessary running of 2.5 Sqmm copper conductor flame retardant PVC wire as earth continuity conductor alongwith wiring and connecting to the common earth dolly. 45 Supply and fixing switch piano type single pole 5 Amp, 230 Volts complete all as specified and directed 46 Supply and fixing switch piano type single pole 15 Amp, 230 Volts complete all as specified and directed 47 Supply and fixing socket outlet 2 in 1, 5 pin, 5 Amp, 230 Volts complete all as specified and directed 48 Supply and fixing socket outlet 2 in 1, 5 pin, 5/15 Amp, 230 Volts complete all as specified and directed 49 Supply and fixing ceiling rose, surface bakelite with 3 terminals, ISI marked for batten fitting complete all as specified and directed 50 Material and labour for submain wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sqmm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessories ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and directed Note : Two runs of 6 Sqmm cable, one run of 6 Sqmm cable and one run of PVC conduit will be measured as one unit. 51 Material and labour for submain wiring with 1100 Volt grade two single core FRLS wire PVC insulated and unsheathed cable with stranded copper conductor 4 Sqmm drawn into and including electrical grade PVC conduit not less than 25mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surface of wall as per existing including 4 Sqmm multi-stranded copper conductor as earth wire in green colour including taking down old unserviceable submain wiring complete all as specified and directed Note : Two runs of 4 Sqmm PVC FRLS multi-stranded copper cable wire and one run of 4 Sqmm PVC FRLS multi-stranded copper cable earth wire and one run (01 meter) PVC conduit of suitable size ISI mark will be measured as one unit length. 52 Supply and fixing in replacement sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface to match with existing colour of wall including taking down of existing DB complete all as specified and directed 53 Supply and fixing sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface to match with existing colour of wall complete all as specified and directed 54 Supply and fixing MCB SPN 32-40 Amp, 240 Volts breaking capacity 10 KA complete all as specified and directed 55 Supply and fixing MCB SP 5-32 Amp, 240 Volts breaking capacity 10 KA complete all as specified and directed 56 Supply and fixing metal clad box suitable for 230 Volt 50 Hz AC supply three pin with MCB SP 20/32 Amps including removal of old unserviceable one complete all as specified and directed 57 Supply and fixing water heater storage type (Geyser) vertical/ Horizontal type as per site requirement with inner container of capacity 25 Ltrs, electrically operated, AC 230 Volts, BEE 5 Star rated, ISI marked including 04 Nos of hold fastener nuts required suitable size fixed in brick wall, PVC connection pipe hot & cold for Officer, JCO’s and OR Md Accncomplete all as specified and directed 58 Supply and fixing ceiling fan, 230 Volts, 1200mm sweep min air delivery 210 CFM with service valve of the fan 6.0 BEE, 5 star rated with brushless direct current motor (BLDC) type with necessary accessories with fan regulator and electrical connections from ceiling rose to fan terminal complete all as specified and directed 59 Supply and fixing Air circulated fan, 230 Volts single phase, 50 Hz, 300mm sweep, PVC body, high speed motor for better air delivery smooth oscillation, aerodynamically designed & balanced propeller type blades superior low voltage performance complete with all accessories all as specified and directed 60 Supply and fixing decorative wall mounted luminaire made out of polycarbonate with unbreakable globe suitable for LED bulb and provision of LED bulb 1x9/10 Watt complete with all accessories all as specified and directed 61 Supply and fixing energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP-66 for bldg. security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35/ 36 watts with pre-wired and necessary mounting arrangements and provision of 2.5 Sqmm three core copper conductor cable multi-stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5m long bend to required shape with clamps, nut, bolts complete all as specified and directed 62 Supply and fixing fresh air fan PVC body 250mm with louvers size including making of hole/ opening in wall complete all as specified and directed 63 Supply and fixing exhaust fans metal body AC single phase 230/240V of size 300mm sweep with louver and including making of hole/ opening in wall complete all as specified and directed 64 Fixing only of geyser (Electric Water heater storage type) of capacity 25 Ltr, kept in safe custody as per srl No. 39.00, after B/R repairs. Note: Cost of minor petty items if required such as nut bolt/ PVC pipe is included in quoted rate 65 Supply and fixing in replacement wall mounted decorative ultra slim LED tube light fitting 1x10 watt(2’) batten for surface mounted, anodized extruded polycarbonate, environmental friendly high lumen 6500K output fitting, 230 Volts and with installation complete with all accessories internally pre-wired and necessary mounting arrangements, provision of new 3 core multi-stranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed 66 Material and labour for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel including 15mm dia medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron ppe light grade 20mm dia, PCC chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate No. 3 of SSR Part-I including excavation and earth work in any type of soil/ strata and testing on completion complete all as specified and directed.Note : GI earth wire 4mm dia and 15mm dia protection pipe upto 7.5m from earth plate is deemed to be included in rate quoted. 67 Supply, Install, testing and commissioning LT Distribution Panel (CPRI Approved) cubicle type IP-56 wall mounted, indoor type conforming to IS-5039 of 1983, factory fabricated made out of 2mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of size not less than 1100 x 600 x 300mm to accommodate all accessories/ fittings compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulated with colour coated heat shrinkable sleeve and shall be mounted on DMC supports. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC and having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves.A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painted with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment , front & back opening type, and fixing 2 Nos danger notice plate with letter , figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following (For Officer Md Accn) :-(a) Aluminium Bus bar for 3 phase 4 wire system of 4 x 150 A rated insulated copper strip mounted on resin cast insulator in independent compartment having front openable shutter - One Set. (b) MCCB, four pole, 415 Volt, 100 Amps, 25 KA with adjustable overload setting - 01 No. (c) MCB DP 40 to 63 Amp,10KA-04 Nos (d) MCB SP 10 A - 01 No (e) Indicator lamp LED in Red/Yellow/Blue colour- one set of three. 68 Notes :- (i) The LT panel board will be fixed to the wall in the place of existing U/S panel Bd with suitable no of fastener and lugs, PVC insulated connectors , PVC sleevesincluding necessary civil work reqd to re-fix the panel as per std Engg practice and make the good disturbed surface to match with existing specification of wall.(ii)Taking down of 4 old serviceable meter, recording of meter reading and re-fixing the same meter in new panel in their respective qtr is included in quoted rate.(iii) LT panel board shall be type tested from CPRI for 4000 Amp with breaking capacity not less than 65 KA & IP 56 as per IS 5039 Part-I & II. (A copy of valid CPRI type test report to be enclosed while obtaining approval from GE).(iv) SLD diagram for LT Panel will be got approved from GE before placing the order and final diagram will be fixed on the front and rear door.(v) Rate for the same is deemed to included in the quoted rates. 69 Supply, Install, testing and commissioning LT Distribution Panel (CPRI Approved) cubicle type IP-56 wall mounted, indoor type conforming to IS-5039 of 1983, factory fabricated made out of 2mm thick CRCA sheet outer & 2mm thick CRCA sheet inner of size not less than 1100 x 600 x 300mm to accommodate all accessories/ fittings compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulated with colour coated heat shrinkable sleeve and shall be mounted on DMC supports. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC and having provision for termination of incoming and outgoing cables. All extension links/ interconnections shall be colour coated sleeves.A detachable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painted with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment , front & back opening type, and fixing 2 Nos danger notice plate with letter , figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following (For JCO/ OR Md Accn) :-(a) Aluminium Bus bar for 3 phase 4 wire system of 4 x 100 A rated insulated copper strip mounted on resin cast insulator in independent compartment having front openable shutter - One Set. (b) MCCB, four pole, 415 Volt, 63 Amps, 25 KA with adjustable overload setting - 01 No. (c) MCB DP 40 to 63 Amp,10KA-04 Nos (d) MCB SP 10 A - 01 No (e) Indicator lamp LED in Red/Yellow/Blue colour- one set of three . Notes :- (i) The LT panel board will be fixed to the wall in the place of existing U/S panel Bd with suitable no of fastener and lugs, PVC insulated connectors , PVC sleevesincluding necessary civil work reqd to re-fix the panel as per std Engg practice and make the good disturbed surface to match with existing specification of wall. 70 (ii)Taking down of 4 old serviceable meter, recording of meter reading and re-fixing the same meter in new panel in their respective qtr is included in quoted rate.(iii) LT panel board shall be type tested from CPRI for 4000 Amp with breaking capacity not less than 65 KA & IP 56 as per IS 5039 Part-I & II. (A copy of valid CPRI type test report to be enclosed while obtaining approval from GE).(iv) SLD diagram for LT Panel will be got approved from GE before placing the order and final diagram will be fixed on the front and rear door.(v) Rate for the same is deemed to included in the quoted rates. 71 Supply, laying, testing and commissioning LT underground cable 1100 Volts grade, XLPE insulated and PVC sheathed heavy duty of size 50 Sqmm 3.5 core armoured with multi stranded aluminium conductor laid in pipes, trenches/ ducts, on poles etc of size complete all as specified and directed 72 Supply, laying, testing and commissioning LT underground cable 1100 Volts grade, XLPE insulated and PVC sheathed heavy duty of size 35 Sqmm 3.5 core armoured with multi stranded aluminium conductor laid in pipes, trenches/ ducts, on poles etc of size complete all as specified and directed 73 Supply, laying, testing and commissioning LT underground cable 1100 Volts grade, XLPE insulated and PVC sheathed heavy duty of size 25 Sqmm 4 core armoured with multi stranded aluminium conductor laid in pipes, trenches/ ducts, on poles etc of size complete all as specified and directed 74 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells pipes etc not exceeding 10 sqm on plan and not exceeding 1.5m depth in soft/loose soil etc complete all as specified and directed. 75 Returning, filing in, excavated soil including spreading, levelling, watering and well rammingin layers not exceeding 25cm etc complete all as specified and directed. 76 Removal of excavated materials not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed. 77 Material and labour for sand cushioning for underground cable with locally available sand for protection of cable including spreading and consolidations complete all as specified and directed 78 Supply and laying in trenches dry well burnt locally available sub class ‘B’ bricks over sand cushioning for protection of cable complete all as specified and directed 79 Supply, laying and fixing double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints, sockets, elbows, bends and end caps size of DWC pipe 63mm outer dia and 50mm inner dia all as specified and directed 80 Material and labour for boring of holes under road, pavement, hard-standing by trenchless ultra sound technology/ manual all as per site requirement complete all as specified and directed 81 Supply and laying GI steel tubing, 50mm bore, light grade with all fittings, laid in trenches/ under roads/ along pole/ wall for protection of cable/ GI wire/ GI strip etc complete all as specified and directed
|