Construction Work – Pte Szántó Energy Modernization Of The Building. Energetic Modernization Of Building B In János Szántó Kovács Street Of The University Of Pécs. The Purpose Of The Renovation Is To Improve The Energy Quality Of The Building. The Main Quantitative Data Regarding The Procurement: - 4869 M2 Facade Thermal Insulation - 458 Facade Windows And Doors Replaced - 4318 M2 Floor Area For Office Building Vrf System Architecture: The Building Will Receive Subsequent Thermal Insulation Thermal Insulation Of The Facades - 15 Cm Xps 300 Wb - Or Technically Equivalent - On A General Plinth. On The General Facade, 15 Cm Eps At-H80 - Or Technically Equivalent - With Partially Glued Clinker Covering, 15 Cm Rockwool Insulation At A Height Of 60 Cm (The Size Of A Board) At The Door And Window Eyebrows. In The Case Of Certain Surfaces, The 16 Cm Rock Wool, Eps At-H80 - Or Technically Equivalent - Thermal Insulation May Also Appear In Places (See Marked Places In The Design Documentation). Furthermore, In The Case Of The Southern End Wall And Elevator House, For Fire Protection Reasons, The Entire Facade Is Made With A 15 Cm Rockwool Thermal Insulation System. The Surface Design And Coloring Of The Building Should Match The Color Use Of The Surrounding Dormitory Buildings, As Well As Surface Designs Similar To The Existing Facade According To The Spaces. Subsequent Thermal Insulation Of The Attic - 30 Cm Rock Wool - 0.039 W/M2k. According To The Agreement, The Area Between The Chair Posts In The Attic Will Be Covered With A Walkable Surface (Plank Covering), And After The Attic Lighting Is Dismantled, A Fireproof Slab Seal Will Be Made. The Layers Of The Flat Roofs Will Be Renovated With 16 Cm Pir - 0.023 W/M2k - New Thermal Insulation And Bituminous Waterproofing. Subsequent Waterproofing In The Soil Is Not Made. The Facade Windows (454 Units) And The Roof Level Windows Will Be Replaced. Shading Will Be Solved With Blinds. - Window Pvc, 3-Layer Glazing, Uw - 1,100 W/M2 K - Window Metal, 3-Layer Glazing, Uw - 1,200 W/M2 K - Window Velux - Or Technically Equivalent - 0.78/0.98 Uw - 1,100 W/ M2 K - Window Velux - Or Technically Equivalent - 0.78/1.40 Uw - 1.100 W/M2 K - Metal Double-Leaf Door, Uw - 1.200 W/M2 K - Installation Of New Blinds On The Specified Windows And Re-Installation Of The Old External Shades. Mechanical Engineering: The Existing Radiator System In The Building Is In Operation. The Thermal Energy Is Supplied By District Heating, The Heating Center Was Modernized A Few Years Ago, And Is Not Affected By The Current Modernization. Before Installing The New Fittings, The Radiators And Then The Entire System Must Be Washed With Chemical Water (With Sentinel X400 - Or Technically Equivalent - Additive, 1% Concentration), After Washing, The Radiators Must Be Reinstalled Together With The New Fittings. The Air Conditioners Will Be Removed From The Facade, Because The Building Will Have A Central Cooling System. In The Szántó B Building And The Neck Member Building Part, A Clivet - Or Technically Equivalent - Type 2-Pipe Vrf System Is Planned, Divided Into 21 Systems. The Indoor Units Are Cassette (Q4an-2-Xmi D28 - Or Technically Equivalent -, Q4an-2-Xmi D36 - Or Technically Equivalent -, Q4an-2-Xmi D52 - Or Technically Equivalent -) And High-Wall (Gwmn-2-X
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 88467944
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.