Tender For Thermal And Cold Insulation Services In Mfl During 2024 To 25.; 1 Application of insulation including insulated wool, wire netting, and 22G Aluminium Sheet on pipelines, vessels, tanks and other equipment. Thickness of Insulation up to 1” 2 Application of insulation including insulated wool, wire netting, and 22G Aluminium Sheet on pipelines, vessels, tanks and other equipment. Thickness of Insulation -1½” 3 Application of insulation including insulated wool, wire netting, and 22G Aluminium Sheet on pipelines, vessels, tanks and other equipment. Thickness of Insulation -2” 4 Application of insulation including insulated wool, wire netting, and 22G Aluminium Sheet on pipelines, vessels, tanks and other equipment. Thickness of Insulation -2½” 5 Application of insulation including insulated wool, wire netting, and 22G Aluminium Sheet on pipelines, vessels, tanks and other equipment. Thickness of Insulation -3” 6 Application of insulation including insulated wool, wire netting, and 22G Aluminium Sheet on pipelines, vessels, tanks and other equipment. Thickness of Insulation -3½” 7 Application of insulation including insulated wool, wire netting, and 22G Aluminium Sheet on pipelines, vessels, tanks and other equipment. Thickness of Insulation -4” 8 Application of insulation including insulated wool, wire netting, and 22G Aluminium Sheet on pipelines, vessels, tanks and other equipment. Thickness of Insulation -6” 9 Application of insulation including insulated wool, wire netting, and 22G Aluminium Sheet on pipelines, vessels, tanks and other equipment. Thickness of Insulation -8” 10 Application of insulation including insulated wool, wire netting, and 22G Aluminium Sheet on pipelines, vessels, tanks and other equipment. Thickness of Insulation -10” 11 Application of insulation including insulated wool, wire netting, and 22G Aluminium Sheet on pipelines, vessels, tanks and other equipment. Thickness of Insulation -12” 12 Application of insulation including insulated wool, wire netting, asbestos, cement plaster, water proof compound etc., on pipelines, vessels, tanks and other equipment. Thickness of Insulation up to -1” 13 Application of insulation including insulated wool, wire netting, asbestos, cement plaster, water proof compound etc., on pipelines, vessels, tanks and other equipment. Thickness of Insulation -1½” 14 Application of insulation including insulated wool, wire netting, asbestos, cement plaster, water proof compound etc., on pipelines, vessels, tanks and other equipment. Thickness of Insulation -2” 15 Application of insulation including insulated wool, wire netting, asbestos, cement plaster, water proof compound etc., on pipelines, vessels, tanks and other equipment. Thickness of Insulation -2½” 16 Application of insulation including insulated wool, wire netting, asbestos, cement plaster, water proof compound etc., on pipelines, vessels, tanks and other equipment. Thickness of Insulation -3” 17 Application of insulation including insulated wool, wire netting, asbestos, cement plaster, water proof compound etc., on pipelines, vessels, tanks and other equipment. Thickness of Insulation -3½” 18 Application of insulation including insulated wool, wire netting, asbestos, cement plaster, water proof compound etc., on pipelines, vessels, tanks and other equipment. Thickness of Insulation -4” 19 Application of insulation including insulated wool, wire netting, asbestos, cement plaster, water proof compound etc., on pipelines, vessels, tanks and other equipment. Thickness of Insulation -6” 20 Application of insulation including insulated wool, wire netting, asbestos, cement plaster, water proof compound etc., on pipelines, vessels, tanks and other equipment. Thickness of Insulation -8” 21 Application of insulation including insulated wool, wire netting, asbestos, cement plaster, water proof compound etc., on pipelines, vessels, tanks and other equipment. Thickness of Insulation -10” 22 Application of insulation including insulated wool, wire netting, asbestos, cement plaster, water proof compound etc., on pipelines, vessels, tanks and other equipment. Thickness of Insulation -12” 23 Application of insulation including ceramic blanket, wire binding and 22G/24G Aluminium sheet in pipe lines vessels tanks and other equipment. Thickness of insulation – 2” 24 Application of insulation including ceramic blanket, wire binding and 22G/24G Aluminium sheet in pipe lines vessels tanks and other equipment. Thickness of insulation – 4” 25 Application of Thermone on Steam Tracing Lines 26 Application of insulation on fixed type of valve boxes and flange boxes.Add 3”, 2” and 3” for valves, flanges and expansion bellows respectively of the corresponding pipelines and convert it into square metres. 27 Application of insulation on removable type of valve boxes and flange boxes or Inspection doors. 28 Application of 22G Aluminium cladding only 29 Application of insulation on INLET PIGTAILS with 1” thickness insulating wool, blanket or mattresses finished with aluminium sheet metal cladding. 30 Application of aluminium sheet metal cladding for 1” INLET PIGTAIL 31 Steam Tracer lines with 22G x ¾” wire netting and 0.1mm aluminium foil to be wrapped before insulating the pipelines. 32 Application of ½” thick x 0.9m x 1.2m insulating wool only for INLET PIGTAIL TOP FLANGES. 33 Removing and refixing of insulation on 1” Bottom Pigtails. 34 Providing in existing lines hinged type Inspection door lid with insulation for monitoring at specified locations. 35 Application of Insulation for valves fabric removal type (Pillow) 25 mm Thick per layer, 4 layers insulation and stitching with SS wire (material supplied by MFL) upto 6" 36 Application of Insulation for valves fabric removal type (Pillow) 25 mm Thick per layer, 4 layers insulation and stitching with SS wire (material supplied by MFL) above 6" to 14" 37 Application of Insulation for valves fabric removal type (Pillow) 25 mm Thick per layer, 4 layers insulation and stitching with SS wire (material supplied by MFL) above 14" 38 Application of Insulation for valves fabric removal type with fabric cloth withstanding 500°C (Pillow) - 25 mm thick per layer, 4 layers insulation and stitching with SS wire (with contractors own material) - Upto 6" 39 Application of Insulation for valves fabric removal type with fabric cloth withstanding 500°C (Pillow) - 25 mm thick per layer, 4 layers insulation and stitching with SS wire (with contractors own material) - Above 6" to 14" 40 Application of Insulation for valves fabric removal type with fabric cloth withstanding 500°C (Pillow) - 25 mm thick per layer, 4 layers insulation and stitching with SS wire (with contractors own material) - Above 14" 41 Removal of old insulation only up to 100 mm thickness (25,50, 75 & 100) 42 Removal of old insulation only - 125 mm thickness 43 Removal of old insulation only - 150 mm thickness 44 Removal of old insulation only - 175 mm thickness 45 Removal of old insulation only - 200 mm thickness 46 Removal of old insulation only - 250 mm thickness 47 Removal of old insulation only - 300 mm thickness 48 Removal of old insulation only - 400 mm thickness 49 Removal of old insulation only - 450 mm thickness 50 Manpower Rate for normal working hours (8 Hours) 51 Working after Office Hours, Sundays & MFL Paid Holidays (per Hour) 52 Supply of materials on need basis in emergency cases(Percentage increase over the original bill value) 53 "Z" Block removal and fixing and all sides packing with ceramic blanket 54 Ceramic Blanket packing in Z Block area/ header 55 Packing in between blocks by 6 mm Ceramic Blanket / Board 56 Skirting Job for Reformer tube bottom
|