Medical Oxygen, Purity 99.5, Supplied In Cylinders With Capacity From 2 To 10 M³, Medical Oxygen Type G5 (Postatil), Supplied In Cylinders With Capacity From 0.3 To 1.0 M³, Rental Of Cylinders For Medicinal Gases, Rental Oxygen Concentrator Capacity Of 5 Liters/Min., Rental Of Oxygen Concentrator Oxygen Capacity Of 10 Liters/Min., 11/11/2024, Rental Of Pressure Regulating Valve With Flowmeter Or Adjustable Pressure Regulating Valve For Medicinal Oxygen., Rental Of Kit For Oxygen Therapy Composed Of 01 Fixed Pressure Regulator With Flowmeter Or With Adjustable Pressure For Medical Oxygen01 Mask For Oxygen Therapy Or Glasses Type Nasal Catheter01 Plastic Humidifier01 Silicone Extender01 Transport Trolley For Oxygen Cylinder (Cylinder With Capacity Of 3 To 50 Liters)., Monthly Rental Of Medical Compressed Air Generation System. The System Must Be Composed Of 02 (Two) Rotary Screw Type Compressors, 7.5 Hp Engine, 125 Psi Working Pressure, Three-Phase 220V Voltage, 60 Hz Frequency. The Medical Air System Must Follow The Technical Standards And Recommendations Of Abnt Nb12188 Of The Ministry Health Ordinance Rdc50 Of February 21, 2002. The System Must Meet A Minimum Effective Production Capacity Of 45 M³/H At A Working Pressure Of 8 Bar. Of Medical Vacuum Generation. The System Must Be Composed Of 02 (Two) Vacuum Generating Units, Rotary Vane Type, Air Cooled, Single Stage, Minimum Flow 40M³/H, Operating Vacuum 690Mmhg, Effective At Sea Level Medical Vacuum System Must Follow Technical Standards And Recommendations From Abnt Nb12188, From The Ministry Health Ordinance Rdc50 Of February 21, 2002Visual And Audible Alarm System That Can Operate With The Hospitals Emergency Electrical System, In The Event Of A Breakdown Or Power Outage, The Pump Must Be Controlled By An Electrical Panel, Direct Start, Equipped With Contactors, Relays , Luminous Indicators, Timers And Selectors For Manual Or Automatic Operation Inversion Protectors Phase, Under And Overvoltage, Phase Lack Indicator And Automatic Inversionvertical Cylindrical Reservoir In Carbon Steel, Minimum Capacity 500 Liters, Equipped With Drains, Ball And Check Valves, Vacuum Gauges And Vacuum Switches, Tubes And Connections, 08 Vibrastop Installation Of Two Bacteriological Filters In Parallel, Upstream Of The Reservoir, With Capacity To Remove Particles Greater Than 0.1 (One).(According To Notice), Provision Of Corrective And Preventive Maintenance Service For A Centralized System Of Medicinal Gases And Oxygen Therapy Equipment (Oxygen, Compressed Air, Vacuum And Nitrous Oxide), With Supply And Exchange Of Equipment Spare Parts.
|