Tender For supply installation testing and commissioning Of Dg Set And Electric Wiring Work At Gas Operated Crematorium In Municipal Board Aburoad , Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (Is:694) On Surface Isi Marked ( Is:14927 P - Ii ) Virgin Material Upvc Trunking & Its Accessories, Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earth Terminal/ Surface Moulded Virgin Material Upvc Modular Box , 10 A Modular Switch,Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose/Holder /3 Way Connector, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter-53, 54 & 56 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Short Point (Up To 3 Mtr.) , Medium Point (Up To 6 Mtr.) , Wiring Of 3/5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade(Is:694) On Surface Isi Marked ( Is:14927 P - Ii ) Virgin Material Upvc Trunking & Its Accessories, Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earth Terminal/ Surface Moulded Virgin Material Upvc Modular Box, Modular 10A Switch, 3/5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheets & Electrical/ Wiring Accessories Refer Chapter-53, 54 & 56 For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr. On Board , S&F Following Sizes Of Isi Marked ( Is:14927 P - Ii ) Virgin Material Upvc Trunking Along With Accessories Like Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc. On Surface With Screws, Expansion Fasteners As Required. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr32 Mm X 12 Mm , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr. 2 X 2.5 Sq. Mm. + 1X1.5Sqmm , 4 X 4.0 Sq.Mm , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Horizontal Type Double Door ( Metal / Glazed )Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Powder Painted Complete With Reversible Door (For Double Door Db Only )100 Amp. Insulated Copper Bus Bar/Shorting Link , Copper Neutral Link, Copper Earth Link , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar,Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr. Metal Door (Three Phase) Ik-09 And Ip-43 With Metal End Box. 4 Way , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Of Load And Site Requirement) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted In Existing Distribution Board/Sheets, Minimum Electrical Operation 20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A & Above Rating Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr. Single Pole Mcb (With B/C Curve Tripping Characteristics) 6 A To 32 A Rating , Triple Pole Mcb (With B/C Curve Tripping Characteristics) 6 A To 32 A Rating , Four Pole Mcb (With B/C Curve Tripping Characteristics) 6 A To 32 A Rating , Plate Earthing As Per Is:3043 With Hot Dipped G.I. Earth Plate Of Size 600Mm X 600Mm X 6.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 20 Mm Dia. G.I. B Class Watering Pipe ,Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. And Embodying The Pipe Complete With Alternate Layers Salt And Coke/ Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In-Charge During Site Visit And Ensure To Enter In Measurment Book.All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "A" Attached With This Bsr . , Supply & Laying Following Size Earth Strip In Horizontal Or Vertical Run In Surface By Means Of Earth Strip Dmc Insulator Including Riveting/ Soldering/ Welding, Jointing Shall Be Done By Overlapping And With 2 Set Of Brass (For Cu Strip) / Gi (For Gi Strip) Nut Bolt & Spring Washer Spaced At 50Cm Making Connection Etc. As Required.All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "A" Attached With This Bsr . 32Mm X6mm G.I.( Hot Dipped ) Strip , Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground/Surface/Recess Including Riveting, Soldering, Saddles, Making Connection With Gi/Cu Purity Purity >95% Thimble Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "A" Attached With This Bsr . 10 Swg G.I. ( Hot Dipped ) Wire , Providing & Fixing Of 450 Mm Sweep Oscillating Type Wall Mounting / Pedestal Type Fans With Three Speed, On And Off Position, Sintered Iron Bush Oil Impregnated, With Metal Front And Back 120 Or More Ribs Guard; Three No. Aluminium Blades, Minimum Air Delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./Min/Watt, Noise Level Should Be <= 75 Db, Power Consumption <= 120 Watts, Motor Protection Through Thermal Overload Protection Device, Including Fixing With Anchor Bolts, Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "A" Attached With This Bsr . Wall Mounting Type With Adjustable Vertical Angle , Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Powder Coated Extruded Aluminium Housing With In Built Driver , System Lumen Efficacy = 110 Lm/Watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,Thd < 10% , P. F.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79 & Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "A" Attached With This Bsr . 1170Mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm , Providing & Fixing Of Energy Efficient /Energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm/Watt Output ,Pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°K / 4000°K / 5700°K /6000°K/6500°K (As Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (Lm79/Lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In-Charge . For Additional Technical Parameters Of Product/ Work, Refer Annexure "A" Attacheded With This Bsr. 15 Watt , Providing & Fixing Of Iso Certified Company Made On Load Change Over Switch, Front Handle Operated, Four Pole 415 V As Per Pwd Specification For Electrical Works Conforming To Is/Lec 60947-3 : 1999 Including Connections , Testing Etc. As Required .In The Following Rating. Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted . All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "A" Attached With This Bsr . With Sheet Steel Enclosure Made Out From Crca Sheet Door 1.2Mm & Body 1.6Mm Thick, Powder Quoted, Door Locking System Allow Opening Of Door In Off Position Only With 2 Nos External Earthing Points. 63 A , Sitc Of Radiator Cooled And Turbo Charged Silent Dg Set (As Per Latest Cpcb Emission Norms) Having Specifications As Per A, B, C, D, E, F,G,H & I A) 1500 Rpm Diesel Engine Conforming To Bs:649/5514 Of Suitable Bhp (Up To 82.5 Kva 6 Cylinder Or Below Required, 125 Kva & Above Ratings 6 Cylinder Or Above Required ) Capable Of Taking 10% Over Loading For One Hour After 12 Hours Of Continuous Operation., Dry Exhaust Mainfold With Hospital Grade Silencer And Catalytic Convertor(Isolated From Main Dg Chamber), Up To 3 M Exhaust Piping (With Lrb Insulation & Alum. Cladding ) As Required . B) Ac Brush Less Spdp Alternator Conform To Bs 5000 (Part 99) Or Is/Iec 60034-1. . Alternator Shall Be Self Regulated With Standard Alternator Protection( Over Voltage , Over Speed & Under Voltage, Under Speed Warning & Shutdown).Engine & Alternator Mounted On A Common Base Frame & Coupled Through A Flexible Coupling Or Close Coupled C) Cpcb / Arai Approved Standard Canopy With Weatherproof, Powdercoated Accoustic Enclosure For Dg Set For Sound Attenuation Fabricated From 1.6 Mm Crca Sheet Steel (Structure) With Sidewall Fabricated From 1.6 Mm Crca Sheet & Filled With Glasswool (96Kg/M3) / Foam. As Per Is8183 The Doors Of 28/40/50/85Mm Thick As Perrating And Fabricated From 1.6Mm Crca Sheet Packed With Accoustic Material, All Doors/Opening Are Sealed With Neoprene /Epdngaskets. The Dg Set Has Inbuilt / External In Fuel Tank To Run 6 To 8 Hrs As Per Oem Standard, With Protection And Tripping Of Dg Set Against Temperature Of More Than 50 Degree Centigrade. D) Electronic / Mechanical Governor, Manual & Electric Start ,Batteries With Battry Charger, Engine Instruments Panel,Avm Pads All Controls For Operation Of Dg Set Are From Outside The Enclosure With Dg Control Panel Having Microprocessor Based Genset Monitoring Like Running Hour, Rpm, Low Lube Oil Tripping & Control System, Panel Mounted Mccb/Acb Of Suitable Rating, Ammeter, Voltmeter, Pf Meter, Frequency Meter, Kwh Meter,Digital Fuel Display Meter, Ind.Lamps Etc. Mounted Inside Enclosure , Visible And Accessible From Outside. The Enclosure Should Be Suitable For Following Capacity Dg Sets And Alternator. Noise Level Shall Be Less Than 75 Db At A Distance Of 1 Mtrs. Duly Certified By Authorised Agency Etc. Complete In All Respect Of Following Capacity : E) (I) Accoustic Glass Wool Wall Thickness Should Not Be Less Then 40Mm And Not Less Then 20Mm Pu Foam Upto Rating 100 Kva. (Ii).Accoustic Glass Wool Wall Thickness Should Not Be Less Then65mm And Not Less Then 50Mm Pu Foam Upto Rating 250 Kva. (Iii)Accoustic Glass Wool Wall Thickness Should Not Be Less Then 100Mm For Rating Above 250 Kva. F) First Filling Of The Fuel Tank Shall Be Done By Contractor And The Prevailing Fuel Cost At That Time Shall Be Reimbursed To The Contactor By Department. G) Servicing Contract Of Dg Set From Oems Authorised Service Dealer As Per Oem Guidelines During The Dlp Period Shall Be Done By Contractor Including All Consumables, Actual Charges Shall Be Reimbursed To The Contractor By End User Department. H) Manufacturer / Oem Must Have Its Authorized Service Dealer In Rajasthan. Which Can Provide Service Within 6 Hours Of Compalint Registration. I) Dg Set Will Be Offered For Inspection And Testing At Manufacturers Works In Presence Of Departmental Engineers. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "A" Attached With This Bsr . 20 Kva At 0.8 Pf 415V 50Hz 3-?
|