Single Stretcher Trolley – Minimum Specifications: Stainless Steel, With Grilles On The Sides., Air Conditioning – Minimum Specifications: Split Type, Hot And Cold, 9,000 To 12,000 Btus., Horizontal Floor Autoclave (Small Size) – Minimum Specifications: Capacity 90 150 L, Load Rack, Rack Car, Osmosis Reverse, Sliding Door Type Printer, Up To 2 Doors, Deionizer – Minimum Specifications: Capacity For 50 Liters Per Hour, Barcode Reader – Minimum Specifications: That Is On The Production Line By The Manufacturer; Manual Gun Type With Bidirectional Light Beam, 650Nm Laser Light Source; Audible Reading Indicator; Reading Speed Of 100 Lines Per Second, Ability To Read Barcode Labels 16Cm Or More Wide; Code Decoding Capability: Upc/Ean, Upc/Ean With Complements, Ucc/Ean 128, Code 39, Code 39 Full Ascii, Code 39 Trioptic, Code 128, Code 128 Full Ascii, Codabar, Interleaved 2 Of 5, Discrete 2 Of 5, Code 93, Msi, Code 11 Have Minimal Interface Usb., 08/11/2024, Water Distiller – Minimum Specifications: Capacity Up To 5Liters / Per Hour, Laboratory Microscope – Minimum Specifications: Binocular Phase Contrast Biological Laboratory Microscope. Can Be Used In Clinical Pathology Or For Research Work. Observation Tube At Minimum 160 Mm Long With Binocular Head Tilted At 30° And 360 Degree Rotation, With Interpupillary Distance Adjustment And Diopter Adjustment For The Two Eyepieces; Reverse Quadruple Revolver; Flat Chromatic Phase Contrast Objectives 10X Ph, 40X Ph Retractable And 100X Ph E Immersion, Type O.G; 01 Pair Of Wide Field 10X Flat Eyepieces With 20 Mm Diameter, Allowing Configurable Magnifications Between 100X And 1000X (It Is Desirable To Have Optional Configuration Up To 1600X With 16X Eyepieces); Double Plate, Mechanical With Graduated Charriot With Control For X And Y Movements And Blade Fixation; Coaxial Adjustment Of Micrometric And Macrometric Focusing, With Independent Knob, With Pressure Control (Torque) Exerted On The Coarse Adjustment And Safety Lock To Limit The Height And Thus Avoid Damage To The Objective Blade, The Vertical Adjustment Distance Of The Focus Must Be Within Minimum 22 Mm, With A Minimum Fine Adjustment Division Of 0.002 Mm; Comes With Polarization, Centering Eyepiece, Phase Contrast Turret; Electric Koehler Illuminator With Spherical Collector; Green And Blue Filters; Lighting: Halogen Lamp Of At Least 6V/20W Or Led Of Equivalent Power, With Light Intensity Adjustment; Power Cable With Double Insulation; Instruction Manual And Cover To Cover The Microscope; Electrical Power Supply To Be Defined By The Requesting Entity., Laminar Flow Hood – Minimum Specifications: Unidirectional Flow Equipment For Handling Uncontaminated Materials. Built Externally In Steel Sheet Treated With Electrostatic Epoxy Coating And Stainless Steel Platform. Siroco Type Ventilation System. Absolute Hepa Type Filter, Pleated And Framed In Galvanized Steel With 99.99% Efficiency In Retaining Particles Up To 0.3 Microns, Synthetic Pleated Pre-Filter. Hepa Filter: Fea 919 Pleated. Digital Display, Hepa Absolute Filter Differential Pressure Indicator, Hour Meter That Indicates Running Minutes And Hours Of Cabin Operation And Other Parameters. Work Area Lighting With Fluorescent Lamp And Germicidal Lamp. Minimum Dimensions: 6
|