Preventive Maintenance Service, With Sanitization And Cleaning Of Split-Type Air Conditioning, Including Total Washing Of The Condenser, Retightening Of Electrical Contacts, Replacement Of Filters And Replacement At The Place Of Origin, Including Removal And Installation Expenses, With Preparation Of The Pmoc - Maintenance, Operation And Control Plan For Air Conditioners – With Emission Of Art (Technical Responsibility Note)., Corrective Maintenance Service On Split Type Air Conditioners., Installation Service For Split Model Air Conditioners Included All Materials Necessary For Perfect Installation Of The Device, Such As: Copper Piping, Pvc Piping , Insulation, Interconnection Cables, Channels, Screws, Bushings, Vinyl Tape, Fluid Supplement, Etc., Distance Maximum Condenser And Evaporator Installation Of 02 Meters., Rotary Compressor Replacement - For Air Conditioning From 9,000 To 32,000 Btus, Split Propeller Replacement - For Air Conditioning From 9,000 To 32,000 Btus, 11/08/2024, Evaporator Fan Motor Replacement - - For Air Conditioning From 9,000 To 32,000 Btu’S, Condenser Fan Motor Replacement - For Air Conditioning From 9,000 To 32,000 Btu’S, Coil Temperature Sensor Replacement - For Air Conditioning From 9,000 To 32,000 Btu’S, Ambient Temperature Sensor Replacement - For Air Conditioning 9,000 To 32,000 Btu’S, Replacing The Split Defrost Sensor - For Air Conditioning 9,000 To 32,000 Btu’S, Replacing The Split Contactor - For Air Conditioning 9,000 To 32,000 Btu’S, Replacing Electronic Boards - For Air Conditioning 9,000 A 32,000 Btus, Split Welding Service For Air Conditioners From 9,000 To 32,000 Btus, Replacement Original Split Remote Control – Original, Replacement Of 5/8 Flame-Resistant Sponge Tube, Shielded – 2M Size, Replacement Of 3/8 Anti-Flame Sponge Tube -Flame, Shielded – With Size 2M1, Capacitor Replacement Compressor Starter 480 Uf45 - For Air Conditioning From 9,000 To 32,000 Btus, Capacitor Replacement 32,000 Btu’S, Compressor Start Capacitor Replacement 480 Uf35 - For Air Conditioners From 9,000 To 32,000 Btu’S, Compressor Start Capacitor Replacement 280 Uf35 - For Air Conditioners From 12,000 To 32,000 Btu’S, Compressor Start Capacitor Replacement 380 Uf35 - For Air Conditioning From 9,000 To 32,000 Btus, Compressor Start Capacitor Replacement 480 Uf25 - For Air Conditioner From 9,000 To 32,000 Btus, Compressor Start Capacitor Replacement 280 Uf25 - For Air Conditioning From 9,000 To 32,000 Btu’S, Compressor Starting Capacitor Replacement 380 Uf25, Refrigerant Gas Recharge R410a – For Air Conditioning From 9,000 To 24,000 Btu’S, Refrigerant Gas Recharge R22 - For Air Conditioning From 9,000 To 32,000 Btu’S, Refrigerant Gas Recharge R32 - For Air Conditioning From 9,000 To 24,000 Btu’S
|