Supply of Different type of Materials for 2X500 MW, DTPS, Anpara>, Vacuum Pump- Make Hhv Pumps, Model No- 01Sp-016-216 Sl No- 12-19-040, Displacement-17 Meter Cube / Hr, Weight-29Kk (W/O Oil), Oil:G68 Grade Or Equivalent, Capacity 01 Litre , Transformer Dry Type, Power:5Kva Three Phase, Frequency Range Of Operation:50Hz To 400Hz, Hv:280V,Lv:165V,Vector Group:Ynyn0, Hv Taps:265 ,250,235,220V, Impedance:4%, Insulation Class: B, Insulation Level (50Hz 1 Min):4Kv, Tem. Rise-70C, Losses- Fe-20W <(>&<), Make-Trans Power Industries , Support Insulator For Bus Duct Of Hvr Transformer #Type Porcelain, Total Length- 312Mm,#Bottom- Ci Metal Part Of Ø 60 Having 4 Holes Of M8 Tap On 46 Pcd And One Centre Hole Of M14 Tap, #Top- Ci Metal Part Of Ø 50 Having 4 Holes Of M8 Tap On 36 Pcd And One Re Hole Of M10 Tap. #Insulation Level 90 Kv Or More , High Voltage Hrc Fuse Link M/S Bussmann: #Model- 12Abcna3.15, 12 Kv, 3.15 Amps With# Recommended Fuse Clip , Rechargeable Battery For Metrel Make 5Kv Insulation Resistance Tester Model- Mi-2077, Capacity- 4500 Mah, Voltage- 1.2V, Type-Nimh, Type-C, Product Code- A1046.#One Set Consist Of 6 Batteries. , Powertech Make Smps#220Vdc/24Vdc 10A#Model Type 300Si#Sr No-Pspl/11-12/3414 , Model-8085 Reactive Transducer,3Phase 3 Wire Unbalanced,##Output : 4-12-20 Ma Dc Dual,##Input: 110V Ac; 0-1 A, Frequency: 50 Hz, Aux. Supply: 240V Ac, Accuracy Class:0.2%, Range: 190.52Var Lead-0-##190.52 Var Lag Ordering Code: 8085/228/172/251/352/17/A2/,Make : Southern Transducers , Model-8075 Active Transducer,3Phase 3 Wire Unbalanced, Output : 4-20 Ma Dc Dual,##Input: 110V Ac; 0-1 A Ac, Frequency: 50 Hz, Aux. Supply: 240V Ac, Accuracy Class:0.2%, Range: 0-600 Mw, Ct Ratio:20000/5A, Rated Current At 0.85Pf, 21Kv, 500Mw:16166A, Pt Ra : (21Kv/#3) / (110V/#3) Ordering Code: 8075/221/172/251/352/17/A2/0,Make : Southern Transducers , Model-8091 Power Factor Transducer,3 Phases, Output : 4-12-20 Ma Dc,##Input: 110V Ac; 0-1 A Ac, Frequency: 50 Hz, Aux. Supply: 240V Ac, Accuracy Class:0.02 Pf, Range: 0.5 Lead-1-0.5##Lag, Ordering Code: 8091/2/220/172/251/352/17/A1/0,Make : Southern Transducers , Model-8066 Ac Current Transducer, Output : 4-20 Ma Dc Single,##Input: 0-1 A Ac(Transducer To Be Calibrated To 12Ma For 1A Ac Input), Frequency: 50 Hz, Aux. Supply: 240V Ac, Accuracy Class:0.5, Ordering Code:##8066/220/251/352/17/A1/0,Make : Southern Transducers , Model-8061 Ac Voltage Transducer ,Output : 4-20 Ma Dc Single,##Input: 0-110V Ac(Transducer To Be Calibrated To 14.67Ma For 110 V Ac Input), Input Range: 0-137.5V Ac, Frequency: 50 Hz, Aux. Supply: 240V Ac, Accuracy Class:0.5%,##Ordering Code: 8061/220/172/ 7/A1/0,Make : Southern Transducers , Model-8020 Dc Voltage Transducer, Output : 4-20 Ma Dc Dual Isolated,##Input: 0-300V Dc, Aux. Supply: 240V Ac, Accuracy Class:0.5%,##Di-Electric Test Vol. 4 Kv Rms For 1 Min, Ordering Code:##8020/221/305/09/0/1/2,Make : Southern Transducers , Model-8020 Dc Voltage Transducer, Output : 4-20 Ma Dc Dual Isolated,##Input: 0-60Mv Dc, Aux. Supply: 240V Ac, Accuracy Class:0.5%,##Di-Electric Test Vol. 4 Kv Rms For 1 Min, Ordering Code:##8020/221/009/09/0/2,Make : Southern Transducers , Model-8020 Dc Voltage Transducer, Output : 4-20 Ma Dc Dual Isolated,##Input: 0-40V Dc, Aux. Supply: 240V Ac, Accuracy Class:0.5%,##Di-Electric Test Vol. 4 Kv Rms For 1 Min, Ordering Code:##8020/221/009/17/0/1/2,Make : Southern Transducers , Model-8020 Dc Voltage Transducer,##Output : Isolated 4-20 Ma Dc,Input: -15V-0-+15V Dc,##Aux. Supply: 240V Ac, Accuracy Class:0.5%, Di-Electric##Test Vol. 2 Kv Rms For 1 Min, Ordering Code:##8020/221/009/17/0/0 Sa0653942230,Make : Southern Transducers , Model-8020 Dc Voltage Transducer, ##Output : 4-20 Ma Dc Single,Input: 0-10V Dc, Aux. Supply: 240V Ac, Accuracyclass:0.2%,##Di-Electric Test Vol. 1.5 Kv Rms For 1 Min##Ordering Code: 8020/220/153/17/0/0,Make : Southern Transducers , Freq. Transducer #Make : Southern Transducers Hsn Code: 90303340#Type No. : 8071 # Frequency #Transducer#Output : 4-20Ma Dc Dual Isolated (R Max: 500#)#Pt Input Voltage : 110V Ac #Frequency Range : 45-55Hz.#Aux#Supply : 240V Ac; 50Hz#Accuracy : ±0.2% Of Span# Damping #Insulation Level : 3 Kv Ac; 50Hz For 1 Minute(Between O/P#S 2#Kv Ac)#Ordering Code : 8071/221/172/321/17/A2/0#Dimension : 75 X 70 X 113 (L X W X H) , Auxiliary Relay Re 301 4 C/O S/R Contacts With Led Indication Coil Voltage- 24 V Dc, Jyoti Make , Aux Relay Re 300, 4 C/O S/R Contacts With Led Indication ,#Coil Voltage- 220 V Dc, Jyoti Make# , Ut Transformer Cooling Fan, Model- 45063, Sweep-450Mm, Power-132W, Three Phase Motor, Flc-0.3A, Rpm-900, Air Flow- 4500 M3/Hr, Type Of Running-Form-A, Ip55, Make- Marathon Electric , Power Fuse 315A, Size 2 Type- Vsk315, Make- Bussmann , Power Fuse 250A, Size 1 Type- Vsf250,Make- Bussmann , Power Fuse 80A, Size 00 Type- Vsb80,Make- Bussmann , Fuse Ns Type 2A,Make- Bussmann , Fuse Ns Type 4A,Make- Bussmann , Fuse Ns Type 6 A,Make- Bussmann , Fuse Ns Type 10 A,Make- Bussmann , Fuse Ns Type 16 A,Make- Bussmann , Fuse Ns Type 20 A,Make- Bussmann , Fuse Ns Type 32A,Make- Bussmann , Fuse Ns Type 50A,Make- Bussmann , Siemens Make Fuse#3Nw Tia6 Gg 6Amps#440Vac 220Vdc , Siemens Make Fuse#3Nw Tia10 Gg 10Amps#440Vac 220Vdc , Siemens Make Fuse#3Nw Tia25 Gg 25Amps 440Vac 220Vdc , Siemens Make Circuit Breaker Miniature With Aux. Contact Block# Type 5Sx52 C25 220/440V Icu 10Ka Acc.To Is:13947-2#Aux Contact Block: 5Sx9100 Hs 6A/230Vac, 1A/220Vdc 1No+1Nc## , Siemens Make Air Break (Aux) Contactor Relay#(I)01 No. Type 3Th30 40-0B Aux Contact 4 No, Ie/Ac15, System Voltage 500Vac/600Vdc, Coil Voltage 220Vdc +10%, -15%,Iec 947, Is: 13947, With (Ii) 4Nos. Of Nc Add On Contact Block Type-Siemens 3Tx4001-2A Is:13947 Iec 60947 With#(Iii) 01 No. Surge Suprressor (Varistor) # Type- Siemens 3Tx7 402-3Jy1#Us 150-250 Vdc , Siemens Make Air Break (Aux) Contactor Relay#(I) 01 No. Type 3Th30 40-0A Aux Contact 4 No, Ie/Ac15, System Voltage 240Vac,10A, Coil Voltage 240Vac +10%, -15%,Iec 947, Is: 13947, With (Ii) 4Nos. Of Nc Add On Contact Block Type-Siemens 3Tx4001-2A Is:13947, C 60947# , Abb Make (I) 2 Pole Mcb With Auxiliary Contact Block.# Abb S282 Uc K3a, 440Vac/440Vdc,#Order Code-Gh S282 0164 R0317#(Ii) Aux Contact Block-#H-11(1No+1Nc) For Abb S282 Uc K3a, 440Vac / 440Vdc Mcb# , Abb Make (I) 3Pole Motor Protection Cb Having O/L, Short Circuit & Single Phase Protection , Rated Thermal Current 25A, Rated Operating Voltage 690 Vac , Rated Short Cuircuit Breaking Capacity 75Ka At 400V. Ms325-12.5, 690Vac, Ac3, Setting Range 9-12.5A ( I) Aux Contact Block- Hk-11(1No+1Nc) For Ms325-4Order Code-1Sam 101 901 R0001 , Abb Make (I) 3Pole Motor Protection Cb Having O/L, Short Circuit & Single Phase Protection , Rated Thermal Current 25A, Rated Operating Voltage 690 Vac Ms325-4 690Vac, Setting Range 2.5-4A Order Code-1Sam 150 000 R1008 (Ii) Aux Contact Block- Hk-11(1No+1N ) For Ms325-4 Order Code-1Sam 101 901 R0001 , Abb Make (I) 3Pole Motor Protection Cb Having O/L, Short Circuit & Single Phase Protection , Rated Thermal Current 25A, Rated Operating Voltage 690 Vac Ms325-1 690Vac, Setting Range 0.63-1A Order Code-1Sam 150 000 R1005 (Ii) Aux Contact Block- Hk-11(1No+1 C) For Ms325-1 Order Code-1Sam 101 901 R0001 , Fully Automatic Star Delta Starter For 20 Hp Motor With Grp Panal Box Size 750X500x250 Mm With Sfu, Pt (440/110 Volt), Thermal O/L, Power Contactor, Star-Delta Timer, On Off Push Button, And Indication Lamp Of On, Off, O/L, Water Level High And Low On Pan L Door, Make:M/S C&S / M/S Abb / M/S Hensal / M/S Pustron
|