Benchtop Ph And Conductivity Meter. Must Have Backlit Lcd Graphic Display. The Informative Lcd Display Must Show Ph And Conductivity Results Simultaneously On The Main Screen, In Addition To Showing Electrode Status, Date, Time, Sample Identification, User Identification And Calibration Points. The Meter Must Have Keys For Access Functions Easily. It Must Have An Auto-Reading Function That Stabilizes The Reading On The Screen, Informing The User When The Reading Becomes Stable Through Alerts. It Must Have At Least 3 Ph Calibration Points, With Automatic Recognition Of Eua/Nist And Din Buffers And Calibration Editing To Correct Errors Without Complete Recalibration.Non-Volatile Memory That Stores Up To 2000 Data, With Time And Date.Must Have Usb Port For Software Update Which Should Be Provided Free Of Charge. Must Have Connection To Couple Stirrer With Control Directly On The Meter. Must Have Support For At Least 2 Simultaneous Electrodes In Addition To The Stirrer.Ac 110 - 220 V Power Supply.Level Of Protection Ip54, Or Higherminimum Warranty Of 3 Years.Technical Specifications:Ph - Measuring Range: 0 To 14 Or Higherresolution: 0, 1 / 0.01 Or Greaterrelative Accuracy: ±0.002Conductivity - Measuring Range: 0.001Micros To 3000Ms, Resolution: 0.001Micros Minimum; 4 Significant Figures At Minimum, Relative Accuracy: 0.5% Reading ± 1 Digit.Reference Temperatures: 5, 10, 15, 20, 25°C (Standard)Inputs - Ph Electrode: Bnc; Conductivity Probe/Probe With Temperature Or Atc Probe/Probe: 8-Pin Mini-Dinput - Usb, Rs232comes With: Bench Meter; Electrode Holder; Ph Ross Epoxy Rechargeable Ph/Atc Triode Electrode; Conductivity Cell Application Range: 1 Micros/Cm To 400 Ms/Cm;Sample Shaker, Benchtop Turbidimeter, With Nephelometry Measurement Method With Scattered Light Collected At A 90 Degree Angle From The Incident Light, Power Supply: 100 To 240 V, Color Touch Screen , Screen Size Greater Than 5 In. Optical Light Source: 860 Nm. The Equipment Must Allow Readings In The Units: Ntu And Fnu. Range: 0 To 1,000 Ntu. Repeatability: +/-1%. Accuracy: +/- 2% ; Tubidity Resolution: 0.001 Ntu. Interface: At Least One Usb-A For Communication. The Equipment Must Allow Calibration Of At Least 3 Points With Formazine Solutions. Included With The Equipment: User Manual In Portuguese, Set Of Stabilized Formazine Standards For Calibration, Bivolt Power Supply, Dust Protection Cover And 16 Spare 25 Mm Cuvettes With 30 Ml Capacity. 12 Month Warranty. Rbc Traceable Calibration Certificate., Online Free Chlorine And Ph Analyzer, Complete Monitoring System For Automatic And Continuous Measurement Of Free Chlorine By Dpd Method, Using Two Reagents, Buffer + Dpd, And Ph In Drinking Water. Free Chlorine: 0.00 ¿ 5.00 Ppm - Resolution: 0.01 Ppm. Adjustable Cycle Time: From 1 To 12 Min. Ph - Measuring Range: Ph 2 To 12. Resolution: 0.01. Temperature Measuring Range: -10 To +50 °C Or Higher, 1 °C. The Analyzer Must Have An Lcd Screen For Viewing, On The Same Screen, Time/Date Information, Temperature, Free Chlorine And Ph. It Must Have Editable Alarms For Minimum And Maximum Values Of Free Chlorine And Ph. It Must Enable Firmware Updates Without The Need Of Hardware Exchange, Must Have Non-Volatile Memory For Recording Records, Must Store At Least 1500 Lines Of Real Analysis Data
|